Experimental Study on the Fire Resistance of SC Composite Coloumn

SC 합성기둥의 내화성능에 대한 실험연구

  • 이승재 (고려대학교 대학원 건축공학과) ;
  • 강성덕 (고려대학교 대학원 건축공학과) ;
  • 오명호 (목포대학교 건축공학과) ;
  • 김명한 (대진대학교 건축공학과) ;
  • 김상대 (고려대학교 건축공학과)
  • Received : 2007.01.15
  • Accepted : 2007.07.10
  • Published : 2007.08.27

Abstract

The SC (steel-concrete) composite column was developed to take advantage of the relative economy of using concrete as opposed to steel in carrying large compressive forces. As the SC composite column is pre-fabricated, its use can minimize laborand can speed up the erection of a steel building. In this study, an experiment was conducted to analyze the influence of several parameters, such as the load ratio, the concrete ratio of an area, and its performance with or without fire protection, on the performance of the SC composite column. This paper proposes that the calculation of the strength reduction ratios of columns be done by increasing the temperature. Theoretical equations were used to evaluate the effectiveness of the fire resistance of the SC composite column, and the results of the test and analysis were compared. The fire resistance of the SC composite column was increased by decreasing its load ratio, but the concrete ratio of an area has minimal influence on the fire resistance of the SC composite column.

SC 합성기둥은 기존의 합성기둥들이 가지는 내력상승, 방청효과, 공사기간 단축이 가능하고, 충전상태의 육안확인도 용이하여 이와 관련된 연구가 활발히 진행되고 있지만 SC합성기둥의 내화성능에 관한 연구는 미흡한 실정이다. 이에 본 논문에서는 SC합성기둥의 내화성능평가를 위해 하중비, 콘크리트 면적비, 피복유무를 변수로 두어 실험을 수행하였다. 또한 온도증가에 따른 실험체의 강도감소를 단순 수치해석으로 산출하여 내화성능시간을 유추하였고, 실험결과와 비교분석 하였다. 이 실험을 통하여 하중비가 작을수록 내화성능은 향상되었다. 그러나 콘크리트 면적비는 SC합성기둥의 내화성능 향상에 큰 영향을 미치지 못하였다.

Keywords

References

  1. 한국산업규격, (1999) KS F 2257-1, 건축 구조 부재의 내화 시험 방법-일반요구사항
  2. 한국산업규격, (2006) KS F 2257-7, 건축 구조 부재의 내화 시험 방법-기둥의 성능 조건, 2006
  3. 한국산업규격, (2004) KS F 2257-4, 건축 구조 부재의 내화 시험 방법-수직 내력 구획 부재의 성능 조건
  4. 건설교통부 고시 제 2005 - 137호, (2005) 건축물의 피난 . 방화 구조 등의 기준에 관한 규칙 - 내화구조 인정내용
  5. 김흥렬, 이세현 (2002) 강구조의 내화특성 평가를 위한 강재 허용온도기준 및 구조형태의 개선방안 연구, 대한건축학회 논문집 구조계, 18권 3호, pp11-20
  6. 오명호, 김평석, 김명한, 김대중, 김상대 (2004) 비조밀 단면 을 사용한 SC 합성 기둥의 압축 내력에 관한 실험적 연구 대한건축학회 논문집(구조계) : 20권 10호
  7. 오명호, 김범래, 김명한, 김대중, 김상대 (2005) 비조밀단면을 가진 SC 합성 기둥의 휨-압축 내력에 관한 실험 연구, 한국강구조학회 논문집, 한국강구조학회, 제 17권, 4호, pp. 431-438
  8. 오명호, 김명한, 김대중, 김상대 (2005) 비조밀 단면을 가진 철골-콘크리트 합성기둥의 비선형 해석, 대한건축학회 학 술발표대회 논문집(구조계), 대한건축학회, 제 25권, 제 5 호, pp. 147-150
  9. 임윤희, 강성덕, 오명호, 김명한, 김상대, (2007) SC 합성기둥 의 내화성능에 대한 해석연구, 대한강구조학회 논문집(구조계) 심사중
  10. Techical Report SCI Publication 124, The Fire Resistance of Web-infilled Steel columns
  11. Y.C Wang (2000) A simple method for calculating the fire resistance of concrete - filled CHS columns Journal of Constructional Steel Research, Vol. 54, Issue 3, pp. 365-386 https://doi.org/10.1016/S0143-974X(99)00061-9
  12. Y.C Wang, Steel and Composite Structure ISBN 0-415--24436-6
  13. Lin-Hai Han, You-Fu Yang, Lei Xu (2003) An experimental study and calculation on the fire resistance of concrete-filled SHS and RHS columns Journal of Constructional Steel Research, Vol. 59, Issue 4, pp. 427-452 https://doi.org/10.1016/S0143-974X(02)00041-X
  14. Lin-Hai Han, Jing-si Huo (2003) Concrete-filled hollow structural steel columns after exposed to ISO-834 fire standard Journal of Structural Engineering, Vol. 129, No. 1, pp. 68-78
  15. Lin-Hai Han, Xiao-Ling Zhao, M.ASCE, You-Fu Yang, Jin-Bin Feng (2003) Experimental study and calculation of fire resistance of concrete-filled hollow steel columns. Journal of Structural Engineering, Vol. 129, No. 3, pp. 346-356 https://doi.org/10.1061/(ASCE)0733-9445(2003)129:3(346)
  16. Y.sakumoto, T.Okada, M.yoshida, Tasaka (1994) Fire resistance of concrete-filled, fire-resistance steel tube columns Journal of Materials in Civil Engineering, Vol. 6, No. 2, pp. 169-184 https://doi.org/10.1061/(ASCE)0899-1561(1994)6:2(169)
  17. Y .Sakumoto, T.Yamaguchi, T,Okada, M.Yoshida, S.Tasaka, H.Saito (1994) Fire resistance of fireresisstance steel columns Journal of Structural Engineering, Vol. 120, Issue 4, pp. 1103-1121 https://doi.org/10.1061/(ASCE)0733-9445(1994)120:4(1103)
  18. R.. Tremblay (2002) Behavior and strength of partially encased composite columns with built-up shapes, Journal of Structural Engineering, Vol. 128, No. 3, pp. 279-288 https://doi.org/10.1061/(ASCE)0733-9445(2002)128:3(279)
  19. T.T Lie and V.K.R.Kodur (1996) Fire resistance of steel columns filled with bar-reinforced concrete Journal of Structural Engineering, Vol. 122, Issue 1, pp. 30-36 https://doi.org/10.1061/(ASCE)0733-9445(1996)122:1(30)
  20. Kuo-Chen Yang, Hung-Hsin Lee, Olan Chan (2006) Performance of steel H columns loaded under uniform temperature Journal of Constructional Steel Research, Volume 62, Issue 3, pp. 262-270 https://doi.org/10.1016/j.jcsr.2005.07.001
  21. J.M Franssen, D.Talamona, J.Kruppa, L.G.Cajot, (1998) Stability of steel columns in case of fire-experimental Evaluation Journal of Structural Engineering, Vol. 124, No. 2, pp. 158-163 https://doi.org/10.1061/(ASCE)0733-9445(1998)124:2(158)
  22. ENV (1994) Eurocode 4 Design of composite steel and concrete structures Part 1.1: General rules and rules for building, ENV
  23. ISO 834-1 (1999) Fire resistance tests - Elements of building construction and materials
  24. Yunus A. Cengel (2003) Heat Transfer(A Practical Approach) 2nd Edition ISBNS 0-07-245893-3