• Title/Summary/Keyword: 내력평가

Search Result 518, Processing Time 0.021 seconds

Shear Resistance of BESTOBEAM Shear Connector According to the Length (BESTOBEAM 전단연결재의 길이에 따른 전단 내력 평가)

  • Ahn, Hyung Joon;Jung, In Yong;Kim, Young Ju;Hwang, Jae Sun
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.5
    • /
    • pp.483-491
    • /
    • 2015
  • Shear resistance of BESTOBEAM, which has angle as shear connector and was developed with purpose of easy construction, was tested. With the test results shear resistance design equation was proposed. Unlike angle connector of Eurocode 4, BESTO BEMA shear connector behaves like fixed-end beam. Therefor longer span of the shear connector the lower shear resistance it has. As a result, shear resistance of BESTOBEAM shear connector according to its length tends to decrease as its length gets longer. The authors proposed design equation of angle shear connector sased on the test results. The results from the test and the proposed equation match within 10% error range. Therefore the proposed equation can be used for designing shear connector of BESTOBEAM.

Behavior and Strength of Rib Stiffened SC Wall-slab Connection (리브 보강된 SC구조 벽-바닥 접합부의 거동 및 내력 평가)

  • Park, Joung Hak
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.4
    • /
    • pp.349-359
    • /
    • 2014
  • Until now, wall-slab plate of steel plate concrete has been constructed by joint. But, the shear plate has problems in the workability as well as structural integrity. This study investigates the behavior and strength of rib stiffened SC wall-slab connection. Seven prototype specimens of wall-slab connections were fabricated and tested. the structural safety of the specimens was confirmed through the monotonic loading test. Based on the experimental observations, this study propose the strength formula of the joint was proposed. To enhance the reliability of the proposed strength formula, analytical verification was performed through inelastic finite element analysis. Effect of parameters, such as, load point, friction coefficient, on the joint strength was examined. The proposed formula yields a conservative value for most cases.

Axial Strength of RC Columns Extracted from Existing Apartment Housings (기존 공동주택에서 채취한 철근콘크리트 기둥의 내력특성 평가 연구)

  • You, Young-Chan;Shin, Hyun-Seop;Choi, Ki-Sun;Lim, Byung-Ho;Kim, Keung-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.100-108
    • /
    • 2010
  • The axial strength of existing RC columns were experimentally investigated in this paper to understand the strength characteristics of existing structural members and to get a appropriate data in strengthening design of RC members in a remodelling construction. Ten RC columns were prepared by being cut and extracted directly from the demolition site of the apartment housings. Each column was tested under uniaxial loadings with different eccentricities in order to evaluate the axial strength of existing RC columns. From the test results, it was found that axial strength of all the specimens were at least 75% higher than those of the theoretical values required by current code. But member displacement ductility ratio were relatively low ranging from 2.12~5.86.

A Study on the Ultimate Load of Electric Transmission Tower Considering Member Strength and Joint Strength (부재 내력과 접합부 내력을 고려한 송전강관철탑의 극한하중 도출에 관한 연구)

  • Kim, Woo-Bum;Jeon, Bum-Jun;Suh, Yong-Pyo
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.5
    • /
    • pp.435-443
    • /
    • 2010
  • The current design practice of an electric transmission tower is based on the allowable stress design. Design strengths of the electric transmission tower's compression member are determined by buckling the strength of the member itself without considering joint strength. There is a possibility of a joint failure prior to the buckling of a member. Therefore, in this study, joint strength is calculated for various member forces, and the shape of joint and database of strength were established. These data was compared with the member strength obtained from previous research studies based on an equivalent nonlinear analysis technique. Finally, practical evaluation and design method to distinguish failure mode in an electric transmission tower member is proposed.

Behavior and Strength of Wall-Slab Connection in SC Structure (SC구조 벽-바닥 접합부의 내력 및 거동 특성)

  • Kim, Hyeong Gook;Kim, Woo Bum;Kim, Won Ki
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.347-354
    • /
    • 2008
  • Steel plate-concrete (SC) structure has recently been used in nuclear power structure because of its construction efficiency. In this study, experimental and analytical study to investigate the behavior of the SC structure's wall slab connection was carried out. Experiments were performed for typical SC and RC connections in order to examine the basic difference between each structure. Finite element analysis was performed and the result of the analysis was found to closely reflect the experimental result. By varying the thickness of the shear plate and friction coefficients and the distance of applied load from the wall, the influence of the parameters on the joint strength and failure modes were examined. Finally, it was confirmed that the joint strength formula proposed in th this research gives conservative results.

Shear Strength of Anchors under Load Applied Angle and a Group Anchors at an Edge (앵커간격 및 하중방향에 따른 앵커의 전단내력)

  • Kim, Sung-Yong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.3 no.3 s.10
    • /
    • pp.133-141
    • /
    • 2003
  • This study concerns the prediction of shear capacity, as governed by concrete breakout failure of the anchors under load applied angle and an group anchors at an edge and installed in uncracked, unreinforced concrete. For this purpose, the methods to evaluate the shear capacity of the anchors in concrete are summarized and the experimental data are compared with capacities by the two present methods: the method of ACI 349-90 and concrete capacity design (CCD) method.

Evaluation of Lateral Load Resistance Capacity of a High-rise Shear Wall Apartment Based on Elasto-plastic Analaysis (정적 탄소성 해석에 의한 고층 벽식 아파트의 수평내력 검토)

  • 전대한;강호근;조한욱;이정원
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.31-40
    • /
    • 1998
  • The purpose of this study is to investigate static elastoplastic behaviour and estimate ultimate resistance capacity of a high-rise apartment shear wall system subjected to a vertical distribution of lateral loading along the height. A typical 25-story two unit plan apartment is selected as a representive model. For the analysis, the pushover analysis is adopted to estimate initial elastic stiffness, post-yielding stiffness and story shear yield resistance level on each story of the structure through three-dimensional nonlinear analysis program-CANNY. In the result of elastoplastic analysis, it is observed that the yield strength of building structures is 1.6 times larger than required lateral design strength.

  • PDF

Evaluation of The Lateral Strength Performance of Rigid Wooden Portal Frame (강절형 목질 문형라멘프레임의 수평내력성능 평가)

  • Lee, In-Hwan;Song, Yo-Jin;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.535-543
    • /
    • 2017
  • For column-beam gussets of wooden structures, slit-processed members inserted with a steel plate are used in general. In this study, a rigid portal frame bonded with a joint was fabricated and a semi-rigid portal frame was fabricated by making a wooden gusset, a replacement for steel plate, of which a half was integrated into the column member and the other half was joined with the beam member by drift-pins. The lateral strength performance of the wooden portal frame was compared with that of the steel plate-inserted joint portal frame. The lateral strength performance was evaluated through a perfect elasto-plasticity model analysis, sectional stiffness change rate, and short-term permissible shear strength. As a result of the experiment, the maximum strength of the rigid portal frame was lower than that of the steel plate-inserted joint portal frame. The yield strength and ultimate strength were calculated as 0.58 and 0.48, respectively, but the measurements of initial stiffness and cumulative ductility improved by 1.35 and 1.1, respectively. As a result of the perfect elasto-plasticity model analysis of the semi-rigid portal frame, the maximum strength was lower than that of the rigid portal frame, but the toughness after failure was excellent. Thus, the ultimate strength was higher by 1.05~1.07. The steel plate-inserted portal frame showed rapid decrease in stiffness with the progress of repeated tests, but the stiffness of the portal frames with a wooden joint decreased slowly.

Cyclic Lond Testing for Strong Axis Joints Connected with SRC Column and RC Beams (SRC기둥-RC보 강축 접합부 상세의 구조성능 평가)

  • Moon, Jeong-Ho;Lee, Kang-Min;Lim, Jae-Hyung;Oh, Kyung-Hwan;Kim, Sung-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.401-409
    • /
    • 2007
  • The objective of this research is to provide better knowledge on the behavior of strong axis SRC column-RC beam joint, supported by experimental results, that can be broadly applicable to many structures. For this purpose, firstly literature reviews and field survey were made to classify the most commonly used for these types of joints. Then, experimental program was designed and performed including 6 SRC column-RC beam joint specimens designed with various joint details. Using the experimental results obtained from the quasi-static cyclic tests, structural performances of the joints such as hysteretic curves, maximum strength capacities, strength degradation beyond the maximum strength, ductilities, and energy dissipation capacities were investigated. Test results showed that specimens with wide beam shape (RCW-P, RCW-W, RCW-F) and T beam shape (RCT-W) showed better structural performances than the bracket type specimens (HBR-L, HBR-S). These specimens also revealed to have higher strength capacities than the nominal design strength. However, H beam bracket type specimens (HBR-L, HBR-S) need further study both analytically and experimentally to verify the reason for unexpected structural performances.

Required Strength Spectrum of Low-Rise Reinforced Concrete Shear Wall Buildings with Pilotis (필로티 구조를 가진 저층 철근콘크리트 전단벽식 건물의 요구내력 스펙트럼)

  • Lee, Kang-Seok;Oh, Jae-Keun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.5
    • /
    • pp.61-69
    • /
    • 2007
  • The main purpose of this study is to provide a basic information for the seismic capacity evaluation and the seismic design of low-rise reinforced concrete (RC) shear wall buildings, which are comprised of a pilotis in the first story. In this study, relationships between strengths and ductilities of each story of RC buildings with pilotis are investigated based on the nonlinear seismic response analysis. The characteristics of low-rise RC buildings with pilotis are assumed as the double degree of freedom structural systems. In order to simulate these systems, the pilotis is idealized as a degrading trilinear hysteretic model that fails in flexure and the upper story of shear wall system is idealized as a origin-oriented hysteretic model that fails in shear, respectively. Stiffness properties of both models are varied in terms of story shear coefficients and structures are subjected to various ground motion components. By analyzing these systems, interaction curves of required strengths for various levels of ductility factors are finally derived for practical purposes. The result indicates that the required strength levels derived can be used as a basic information for seismic evaluation and design criteria of low-rise reinforced concrete shear wall buildings having pilotis structure.