Cyclic Lond Testing for Strong Axis Joints Connected with SRC Column and RC Beams  

Moon, Jeong-Ho (Dept. of Architectural Engineering, Hannam University)
Lee, Kang-Min (Dept. of Architectural Engineering, Chungnam National University)
Lim, Jae-Hyung (Div. of Remodeling & Architectural Engineering, Woosong Technical College)
Oh, Kyung-Hwan (Samsung Corporation)
Kim, Sung-Ho (Gun Structural Engineering Co. Ltd.)
Publication Information
Journal of the Korea Concrete Institute / v.19, no.4, 2007 , pp. 401-409 More about this Journal
Abstract
The objective of this research is to provide better knowledge on the behavior of strong axis SRC column-RC beam joint, supported by experimental results, that can be broadly applicable to many structures. For this purpose, firstly literature reviews and field survey were made to classify the most commonly used for these types of joints. Then, experimental program was designed and performed including 6 SRC column-RC beam joint specimens designed with various joint details. Using the experimental results obtained from the quasi-static cyclic tests, structural performances of the joints such as hysteretic curves, maximum strength capacities, strength degradation beyond the maximum strength, ductilities, and energy dissipation capacities were investigated. Test results showed that specimens with wide beam shape (RCW-P, RCW-W, RCW-F) and T beam shape (RCT-W) showed better structural performances than the bracket type specimens (HBR-L, HBR-S). These specimens also revealed to have higher strength capacities than the nominal design strength. However, H beam bracket type specimens (HBR-L, HBR-S) need further study both analytically and experimentally to verify the reason for unexpected structural performances.
Keywords
top-down construction method; SRC column-RC beam connection; wing plate; H-beam bracket; field welding;
Citations & Related Records
연도 인용수 순위
  • Reference
1 대한건축학회,강구조한계상태설계기준 및 해설,대한건축학회,1997
2 Hawkins,N. and Ghosh,S. K.,'Proposed Revisions to 1997 NEHRP Recommended Provisions for Seismic Regulations for Precast Concrete Structures Part 2-Seismic Force Resisting Systems',PCI Journal,Vol.45,No.5,2000,pp.34-45
3 Park,R.,'Ductility Evaluation from Laboratory and Analytical Testing State of the Art Report',Proceedings of Ninth Word Coηecneret on Earthquake Engineering,Vol.VII, Tokyo-Kyoto,Japan,Aug. 1988,pp.605-616
4 한국콘크리트학회,'콘크리트 구조설계기준',한국콘크리트학회,2003
5 日本建築學會,鐵骨鐵節ユンワリ-ト造配筋指針 . 同解說,日本建築學會,1996
6 김종호,'역타공법(Top Down Method) 및 지하층 공사시 선설치 시공된 강재 기둥과 RC 보의 접합부 설계',한국강구조학회지,10권 2호,1998,pp.142-150
7 주영규,천성철,'지하 구조물의 철골철근콘크리트 기둥과 철근콘크리트 보 접합부의 구조 성능 평가',대한건축학회 논문집,19권 2호,2003,pp.17-24
8 ACI Committee 318,Building Code Requirements for Structural Concrete and Commentary,American Concrete Institute,2002
9 ACI Committee 352,Recommendations for Design of Beam Column Joints in Monolithic Reinforced Concrete Structures (352-R91),American Concrete Institute, 1991
10 ACI ITG/T1,Acceptance Criteria for Moment Frames Based on Structural Testing,American Concrete Institute,1995