Abstract
Steel plate-concrete (SC) structure has recently been used in nuclear power structure because of its construction efficiency. In this study, experimental and analytical study to investigate the behavior of the SC structure's wall slab connection was carried out. Experiments were performed for typical SC and RC connections in order to examine the basic difference between each structure. Finite element analysis was performed and the result of the analysis was found to closely reflect the experimental result. By varying the thickness of the shear plate and friction coefficients and the distance of applied load from the wall, the influence of the parameters on the joint strength and failure modes were examined. Finally, it was confirmed that the joint strength formula proposed in th this research gives conservative results.
SC 구조는 시공 및 제작성이 우수하여 최근 국내외 원자력 발전소 건설에 적용되고 있는 구조이다. SC 구조의 벽 -바닥 접합부가 갖는 전단력 전달기구를 확인하기 위하여 4개의 실험체에 대하여 실험을 수행하고, 접합부의 거동특성을 분석하였다. 이를 바탕으로 접합부의 전단내력 평가를 위한 해석적 연구를 수행하였다. 그 결과, 실험 결과와 해석결과 간의 근접성을 확인하였고, 접합부의 내력 및 파괴모드를 도출하였다. 그리고 전단플레이트의 두께와 벽면 마찰력의 변화가 접합부 전단내력에 미치는 영향을 파악한 결과, 제안한 접합부 내력식이 보수적인 값을 제시하고 있음을 확인하였다.