• Title/Summary/Keyword: 낙뢰시스템

Search Result 102, Processing Time 0.024 seconds

Development of a USN-Based Monitoring Scenario for Slope Failures (USN 기반의 사면붕괴 모니터링 시나리오 개발)

  • Kim, Kyoon-Tai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.11 no.6
    • /
    • pp.122-130
    • /
    • 2010
  • Seventy percent of Korea's national territory is covered with mountains, and the land is frequently exposed to typhoons and localized torrential downpours, particularly in July through September. For this reason, slope failure is one of the most frequent types of natural disasters in Korea. To prevent the damage caused by slope failure, the Korean government, academia and industry have strived together to develop and install a wired system for monitoring slope failures. However, conventional wired monitoring systems have been reported to have limitations, such as possible system errors caused by lightning, and the difficulties of restoration and management of the systems. To solve these problems, this research suggests a USN-based monitoring system for slope failures. First, the trend of slope measurement and USN technology was analyzed, and then the current status of damage caused by slope failures in Korea was reviewed. Next, a USN-based monitoring scenario for slope failures, incorporating both USN and slope monitoring technique, was developed. Finally, sensors were decided based on the developed scenario. It is expected that the results of this study will be utilized as fundamental data for the development of monitoring prototype systems for slope failures in the future. The development of the USN-based monitoring system for slope failures and its application in the field will also ultimately contribute to the prevention of slope failures and the minimization of related damage.

A Study on the lightning Discharge Positioning (뇌방전 위치표정에 관한 연구(I))

  • Kil, Gyung-Suk;Park, Dae-Won;Kim, Il-Kwon;Choi, Su-Yeon;Ahn, Chang-Hwan;Lee, Young-Kun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.40-45
    • /
    • 2007
  • Lightning warning system plays an important role in protecting human life and other facilities from lightning return strokes. This paper dealt with lightning positioning algorithms and circuits as a main function of lightning warning system, which monitor movements and activities of thunderclouds. Electric field component produced by lightning discharge is detected by the configuration of a whip antenna and a narrow-band resonance amplifier with center frequency of 300[kHz]. Measurement circuit of magnetic field waveform consists of a crossed-loop coil and an integral amplifier, and its frequency bandwidth is ranges from 5[kHz] to 1.2[MHz]. The polarity of lightning discharge is discriminated by electric field component. After-fixing the polarity, we can calculate the direction and distance of lightning discharge by the peak and the zero-cross time of magnetic field waveform.

Frequency-Dependent Resistivity and Relative Dielectric Constant of Soil on Water Content (수분함유량에 따른 토양의 저항률 및 비유전율의 주파수의존성)

  • Choi, Jong-Hyuk;Cha, Eung-Suk;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.98-104
    • /
    • 2010
  • In order to evaluate the performance of a grounding system against lightning or fault currents including high frequency components, the grounding impedance should be considered rather than the steady state ground resistance. To evaluate the ground impedance, the frequency dependence of resistivity and relative dielectric constant of the soil have to be analyzed. This paper deals with the frequency dependence of the resistivity and relative dielectric constant of three types of soil on water content. As a result, the resistivity of soil is getting lower with increasing of water content. It is nearly independent of the frequency in the range less than 1[MHz], and is decreased over the frequency range above 1[MHz]. On the other hand, the relative dielectric constant is rapidly decreased with the frequency in the range less than 1[MHz], but it is nearly independent on the frequency over the range of 1[MHz]. It was found from the experiments that the frequency-dependant resistivity and relative dielectric constant of soil should be considered when designing the grounding systems for protection from lightning or switching surges.

Effective Installation Methods of Down Conductors in Lightning Protection Systems (뇌보호시스템에서 인하도선의 효과적인 설치기법)

  • 이복희;엄주홍;이승칠;강성만
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.8-14
    • /
    • 2002
  • A modern lightning protection system is required to eliminate the risks such as electrical shocks and damages of structures, electrical and electronic equipments due to lightning. However, the conventional lightning protection systems play and important role in protecting persons and structures only. Thus an effective lightning protection system is indispensable today in computer, information and communication facilities and etc. The mafor objective of this paper is to develop the technology to protect electronics and computerized facilities against lightning-caused overvoltages. The study is oriented on the control of the potential rise of down conductors with the type and installation method of down conductors. As a result, to reduce side flashes and hazards caused by the potential rise of down conductor due to lightning current, the coaxial cable with a low characteristic impedance and high insulation level is suitable for a down conductor. In particular it is extremely effective to bond down conductors to the steel supporter, metal raceways and steel frame of structures.

Fabrication and Reliability Properties of Optical Fiber Sensor Cable for Detecting Intruders (침입자 감지용 광섬유 센서 케이블 제작 및 신뢰성 특성)

  • Kim, Jun-Hyong;Jung, Yoon-Seok;Sung, Tae-Kyung;An, Bo-Young;Park, In-Chul;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.208-208
    • /
    • 2009
  • 최근 광섬유 센서기술의 수요는 전 산업분야에 걸쳐 높아지고 있으며, 이에 비례하여 기업 간, 국가 간 경쟁이 첨예화되고 있다. 또한 소형화, 경량화, 고성능화 센서에 대한 요구도 높아지고 있어 종래의 각종 센서들의 형태와 개선을 위한 연구개발이 매우 활발하게 전개되고 있으므로 이를 대체할 수 있는 광섬유 센서의 수요가 급격히 늘어날 전망이다. 기존 침입자 감지 시스템은 태풍, 낙뢰, 폭설, 폭우 등의 기상변화나 지반 흔들림, 통행차량 진동 및 전자기 간섭 등에 영향을 받아 오작동, 오경보가 빈번히 발생된다. 이러한 문제의 해결책으로 광섬유 센서 케이블을 이용한 시스템이 대안으로 부각되고 있다. 현재 국내에서 군부대, 공항을 중심으로 펜스와 휴전선 철책에 힘입자 감지를 위하여 도입되고 있다. 광섬유 센서 케이블을 사용하는 광망경비시스템은 광섬유 센서 케이블을 그물망 형태(광망)로 만들어 경계 지역에 설치된다. 광망경비시스템의 원리는 광섬유에 광펄스를 입사시켜 순환시키는데 침입자가 광망을 절단하거나 외력을 가할 경우 발생되는 레일리 산란에 기인하는 후방산란과 접속점과 파단점에서 생기는 반사광을 OTDR(Optical Time Domain Reflectometer)로 검출하여 침입상황 및 침입위치를 탐지한다. 그러나 이러한 침입자 감지를 위한 광망경비시스템의 핵심부품인 광섬유 센서 케이블은 기존에 전량 해외수입에 의존하고 있는 실정이며, 지금까지 국내에서 생산하기 위한 제작 기술과 노하우가 초보단계에 머물러 있다. 이러한 광섬유 센서 케이블 제작에 있어서 중요한 부분이 패키징 기술이라 할 수 있다. 이는 광섬유 센서를 일반적인 피복 구조로 패키징하게 되면, 센서 고유의 특성이 패키징 과정과 운반과정, 포설과정에서 변하게 되고 센서로써의 신뢰성이 크게 저하된다. 본 연구에서는 힘입자 감지용 광섬유 센서 케이블의 설계와 제작을 위한 제조공법을 확립하고, 이를 이용해 제작된 광섬유 센서 케이블의 신뢰성 특성을 평가하였다. 설계 제작된 광섬유 센서 케이블의 구조는 멀티모드광섬유(MMF) 에 0.9 mm Tight buffer를 코팅하고, 광심선 주위에 아라미드 얀을 삽입시킨 후 고문자 수지를 적용하여 외부 피복 (jacket)을 하였다. 제작된 광섬유 센서 케이블의 외경 측정결과 기준치 ($2.95\;{\pm}\;0.03$ mm)를 모두 만족하였고, 850 nm 파장에서의 광 손실 측정 결과 4.0 dB/km 이하였다. 또한 주요 항목의 신뢰성 특성 시험결과, 인장강도는 8~10 kg의 인장력을 갖으며 온도순환시험 ($-30^{\circ}C\;{\sim}\;+75^{\circ}C$)에서의 광 손실은 0.6 dB 이하로 나타나 침입자 감지용 광섬유 센서 케이블로 적합함을 확인할 수 있었다.

  • PDF

Breakdown Characteristics of Soils Caused by Impulse Currents (임펄스전류에 의한 토양의 절연파괴특성)

  • Lee, Bok-Hee;Lee, Kang-Soo;Kim, Hoe-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.103-109
    • /
    • 2010
  • In this paper, breakdown characteristics of soil in a coaxial cylindrical electrode system stressed by impulse currents were experimentally investigated. The breakdown voltage and current waveforms for 4 types of soils were measured, and the threshold electric field intensity, the time-lag to breakdown and the voltage-current (V-I) curves were analyzed and discussed. As a result, the breakdown voltage and current waveforms are strongly dependent on the grain size of soil, and the voltage and current waveforms for gravel and sand differ from those for silt and loess. The threshold electric field intensity Ec is increased in the order of gravel, sand, loess and silt. The V-I curves for all test samples show a 'cross-closed loop' of ${\infty}$-shape. Also, the time-lag to breakdown for gravel and sand are longer than those for silt and loess. It is expected that the results presented in this paper will provide useful information on the design of improving transient performance of a grounding electrode system subjected to lightning current considering the soil ionization.

Reduction of the the Ground Surface Potential Gradients by Installing Auxiliary Grounding Grids (보조접지그리드의 시설에 의한 대지표면전위경도의 저감)

  • 이승칠;엄주홍;이복희;김효진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.121-129
    • /
    • 2002
  • The present paper describes a technique for installing an effective grounding grids, the major objective is forced on the experimental evaluation of the performance and characteristics with the arrangement and installation method for grounding grids consisting of the means to protect electric shock, electronics and computerized facilities against lightning, switching and ground fault surges. The study is oriented on two major areas: (1) the analysis of the ground surface potential gradient with the arrangement of grounding grids, (2) the control of the dangerous ground surface potential rise. The experiments wee carried out with the impulse currents as a function of the installation method or arrangement of grounding grids. An installation method of the inclined auxiliary grounding grid was proposed to overcome the drawbacks of equally spared grounding grids, i.e. an appropriate design concept far the installation of grounding grids was found out, It has been shown that the installation of the intwined auxiliary grounding grid can also result in a mere than 50% decrease in the maximum potential gradient on the ground surface and enhance the level of safety for persons and electronic equipments..

Vibrational Characteristics on the Cables in Cable Stayed Bridge (사장교 케이블의 진동거동 특성)

  • Sung, Ikhyun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.249-257
    • /
    • 2017
  • Recently, a cable disconnection accident occurred due to a lightning strike at the Seohae Bridge located in Dangjin-Pyeongtaek City. This is a natural occurrence, but it is a recall that it is very important to review the safety issues due to the disconnection of cable bridges. In other words, the role of cables in cable bridges has a profound effect on the safety of the structure, and it has become necessary to grasp the effect on the entire structural system. The cable bridge is an economic bridge that builds the main tower and supports the bottom plate by cable. The influence of the cable is the main member, which is a big influence on the safety of the whole bridge system. In the cable-stayed bridge, the cables exhibit nonlinear behavior because of the change in sag, due to the dead weight of the cable, which occurs with changing tension in the cable resulting from the movement of the end points of the cable as the bridge is loaded. Modal analysis is conducted using the deformed dead-load tangent stiffness matrix. A new concept was presented by using divided a cable into several elements in order to study the effect of the cable vibration (both in-plane and swinging) on the overall bridge dynamics. The result of this study demonstrates the importance of cable vibration on the overall bridge dynamics.

A Study on Certification of Electronic Engine Controls (항공기 엔진제어시스템 인증기술 개발)

  • Lee, Kang-Yi;Han, Sang-Ho;Jin, Young-Kwon;Lee, Sang-Joon;Kim, Kui-Soon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.1
    • /
    • pp.104-109
    • /
    • 2005
  • The aircraft gas turbine engines with the Electronic Engine Controls(EEC) had been developed to save fuel and enhance their performance in the early days, and had employed the health monitoring function in the Full Authority Digital Engine Controls(FADEC) to improve their reliability. This has led to an increasing demand for the certification technology of these controls. The design and certification issues of power supply, aircraft supplied data, failure modes, software verification/validation, and lightning requirements need to be addressed. This paper presents the design considerations and the certification techniques applied to the electronic engine controls. And it is believed that this paper will be basis to establish a requirement in Korean Airworthiness Standard.

Frequency-Dependant Grounding Impedances According to the Length of Grounding Electrode and the Joint Position of Ground Conductors (접지전극의 길이 및 접지도선의 접속위치에 따른 접지임피던스의 주파수의존성)

  • Choi, Jong-Hyuk;Choi, Young-Chul;Cho, Sung-Chul;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.37-43
    • /
    • 2010
  • When lightning surges with wide frequency spectrum and power converting devices are considered, it is desirable to evaluate grounding system performance by grounding impedances. This paper presents the measured results for frequency-dependent grounding impedance for the vertical grounding electrode and counterpoise on a scale of full size. Grounding impedances of vertical grounding electrodes and counterpoises give capacitive or inductive behaviors according to the length of grounding electrodes and soil resistivity. It is inefficient to extend the length of the grounding electrode in order to decrease the ground resistance, and when designing the grounding system, the consideration of the grounding impedance should be desirable. In order to reduce the grounding impedance of counterpoise, the grounding conductors are jointed at the center of counterpoises. It is effective to reduce the grounding impedance by connecting ground rods to counterpoises in parallel.