• 제목/요약/키워드: 기포식

검색결과 140건 처리시간 0.024초

액상 LPG 직접 분사식 기관 개발을 위한 인젝터 내 기포발생현상의 원인 규명에 관한 기초연구 (A Fundamental Study on the Investigation of Bubbling Phenomenon in the Injector for the Development the LPDi Engine)

  • 노기철;이종태
    • 한국자동차공학회논문집
    • /
    • 제14권6호
    • /
    • pp.1-8
    • /
    • 2006
  • One of the most important subjects to develop a LPDi engine is to suppress the bubble generated inside the liquid LPG direct injector. For the purpose of this, the analogy visualization injector to visualize the generation and behaviors of bubble is manufactured, and the bubbling phenomenon and behaviors of bubble are visualized and investigated according to the change of the temperature around an injector wall, fuel pressure and a needle configuration. As results, it was found that the bubble inside the injector is generated around an injector hole and after rising by buoyancy it disappears around the top of a nozzle. The number of bubbles generated is little changed regardless of the lapse of time but it remarkably increases as the temperature around the injector increases. Also, it was known that as the sac volume in LPDi injector decreases the generation of bubble is more active and the rising velocity of bubble generated is increased.

열펌프 시스템에서 원통형 흡수기 내 기포모드의 특성 (Characteristics of Bubble Mode in the Cylindrical Absorber for Heat Pump System)

  • 이기봉;전병희;이재철;박찬진;김성현
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2000년도 추계 학술발표회 논문집
    • /
    • pp.199-204
    • /
    • 2000
  • 산업과 과학발달에 의해 더욱 물질적으로 풍요로워진 인류에게 에너지와 환경문제는 새로운 당면문제로 부각되고 있다. 특히 1992년 몬트리올 협정에서는 CFC 및 HCFC의 사용을 각각 1997과 2002년부터 전면 금지시키기로 하였고, 1997년에는 2008-2012년까지 전세계 온실가스 배출량을 5.2% 줄이는 것을 골자로 하는 교토 선언이 합의되었다. 이러한 상황을 타개하기 위한 많은 연구 중 흡수식 열펌프는 환경친화적인 자연냉매를 사용하는 열구동 시스템으로 다시 주목을 받고 있다. 특히 흡수식 열펌프의 구성요소 중 흡수에 의하여 고온의 열을 얻을 수 있는 흡수기에 효율적인 열·물질전달 모드를 적용함으로써 제품의 소형화와 에너지 손실 감소를 이루고 있다. 이에 본 연구에서는 새로운 흡수기 모드로 연구되고 있는 기포타입모드를 원통형 흡수기에 적용해 보고, 그 특성을 고찰해 보고자 하였다. 흡수기로 유입되는 ammonia gas와 용액을 cocurrnet 및 countercurrent로 흘려주었고, 높이에 따른 농도, 온도 및 압력을 측정·비교해 보았다.(중략)

  • PDF

확산형 흡수식 냉동기용 기포펌프의 운전특성에 관한 연구 (Operating Characteristics of a Bubble Pump for Diffusion-Absorption Refrigerator)

  • 이현경;김선창;이재헌
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.878-887
    • /
    • 2001
  • Experimental investigation has been carried out to examine the operating characteristics of a bubble pump for diffusion absorption refrigerator. The effects of heat input and delivery height on generation rate of refrigerant vapor and circulation rate of solution have been investigated. as a result heat input and delivery height increase, circulation rate of solution increases. And the smaller the tube diameter, the larger the circulation rate of solution. Pumping ratio increases to a critical point and then decrease with the increase of heat input, and it increases with the increase in delivery height. In this paper, Marcus's analytical theory was also examined. It was found that the Marcus\`s analytical theory of a bubble pump was not appropriate for a bubble pump using ammonia aqueous solution as a working fluid.

  • PDF

확산형 흡수식 냉동시스템의 기포펌프 성능실험 (Experimental Performance Study of the Bubble Pump for the Diffusion Absorption Refrigerating System)

  • 이재효;정의갑;윤재호;정의갑
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.287-292
    • /
    • 2004
  • An experimental investigation was carried out to study the performance of a bubble pump for the diffusion absorption refrigerating system. Ammonia was used as the refrigerant and the helium was charged in order to balance the pressure between the low and high pressure side. As experimental variables, the concentration of ammonia charged into system, heat input, and the pressure of helium were selected. Experimental results show that the generation rate of ammonia vapor and the circulation rate of diluted ammonia solution were increased as the heat input increases, but the ratio of the solution to vapor flow rate was decreased. The generation rate of refrigerant vapor and the circulation rate of diluted ammonia solution increased as the system pressure decreased. Finally under the condition of 25 bars, the concentration of rich ammonia solution was not affected by the generation rate of ammonia vapor and the circulation of diluted ammonia solution.

석탄회를 활용한 경량기포 CLSM의 압축강도와 단위중량의 상관관계 (Correlation between Compressive Strength and Unit Weight of Lightweight Foamed Controlled Low Strength Material (CLSM) Using Coal Ash)

  • 이종휘;이혜진;천병식
    • 한국지반공학회논문집
    • /
    • 제29권1호
    • /
    • pp.39-47
    • /
    • 2013
  • 석탄회를 활용한 CLSM(Controlled Low Strength Material)의 적용성이 증가됨에 따라, 본 연구에서는 경량기포CLSM의 압축강도와 단위중량과의 관계에 초점을 맞추어, CLSM 재료에 관련된 기초연구를 수행하였다. 일축압축강도는 구조물에 적용시 재굴착이 가능한지를 판단할 수 있는 기준이 되고 있으며 시험결과를 통해 경제성 및 효율성, 굴착성 등을 판단할 수 있는 중요한 배합설계변수이다. 그러나 CLSM의 일축압축강도는 재령 28일 기준으로 적용성을 판단하기 때문에, 정량적인 일축압축강도값을 알기 위해서는 배합 후 일정시간이 지나야한다. 본 연구에서는 저강도 고유동화재(CLSM)에 기포를 혼입하여 경량화시킨 경량기포 CLSM에 중점을 두어 경량기포 CLSM의 압축강도와 단위중량(기포슬러리 단위중량, 겉보기 단위중량)과의 관계를 분석하였고, 슬러리를 28일까지 양생시키지 않고 단위중량만으로 28일의 압축강도를 쉽게 예측할 수 있는 관계식을 제안하였다.

골재종류 및 기포도입율 변화에 따른 경량기포 콘크리트의 기초적 특성 (Fundamental properties of Lightweight Foamed Concrete by Applying Different Types of Aggregates and Foam Conduction Ratio)

  • 황금광;김대건;문경식;정광복;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.132-133
    • /
    • 2014
  • In this study, high volume of industrial by-products including blast furnace slag, recycled aggregate powder and incineration ash have been utilized on the slurry of the foamed lightweight concrete. As to decrease the price of the lightweight foam concrete, mortar based slurry and concrete based slurry has been fixed. As the variation of the foam conduction ratio and aggregates, the foam ratio and compressive strength has been tested. Results showed that using recycled aggregates in the slurry showed better effect than using natural aggregates due to the alkali properties of the recycled aggregates could activate the potential hydraulic properties of the blast furnace slag. Consider about the low price of the recycled aggregates, it could be identified that using recycled aggregates in high volume blast furnace slag blended lightweight concrete showed better compressive strength than natural aggregates.

  • PDF

점성액체 기포탑에서 탑의 직경이 기포, wake 및 연속액상 체류량에 미치는 영향 (Effects of Column Diameter on the Holdups of Bubble, Wake and Continuous Liquid Phase in Bubble Columns with Viscous Liquid Medium)

  • 임대호;장지화;강용;전기원
    • Korean Chemical Engineering Research
    • /
    • 제49권5호
    • /
    • pp.582-587
    • /
    • 2011
  • 점성액체 기포탑에서 기포, wake 및 연속액상들의 체류량 특성을 고찰하였다. 기포탑의 직경(0.051, 0.076, 0.102 and 0.152 m ID), 기체 유속(0.02~0.16 m/s) 그리고 연속액상의 점도(0.001~0.050 $Pa{\cdot}s$)가 기포, wake 및 연속액상의 체류량에 미치는 영향을 검토하였다. 기포, wake 그리고 연속액상들은 이중 전기 저항탐침방법에 의하여 성공적으로 구별할 수 있었다. 압축된 여과공기와 물 또는 CMC 수용액을 각각 기체와 연속액상으로 사용하였다. 기포탑에서 기포와 wake 상들을 연속적으로 검침하기위해 자료수집장치(DT 2805 Lab Card)와 컴퓨터를 사용하였다. 탐침 써키트로부터 수집된 아날로그 자료는 디지털 자료로 변환되었으며, 이들 자료를 이용하여 기포탑에서 상승하는 단일기포 뿐만이 아니라 다중기포들의 후면에서 wake 상을 검침할 수 있었다. 기포와 wake 상의 체류량은 각각 기포탑의 직경과 연속액상의 점도가 증가함에 따라 감소하였으나 연속액상의 체류량은 증가하였다. 그러나, 기포와 wake의 체류량은 각각 기체 유속이 증가함에 따라 증가한 반면 연속액상의 체류량은 감소하였다. wake 상 체류량에 대한 기포 체류량의 비율은 기포탑의 직경 또는 기체의 유속이 증가함에 따라 감소한 반면 연속액상의 점도가 증가함에 점성액체 기포탑에서 기포, wake 그리고 연속액상의 체류량은 본 연구의 실험범위에서 다음과 같은 실험변수의 상관식으로 나타낼 수 있었다. ${\varepsilon}_B=0.043D^{-0.18}U_G^{0.56}{\mu}_L^{-0.13}$, ${\varepsilon}_W=0.003D^{-0.85}U_G^{0.46}{\mu}_L^{-0.10}$, ${\varepsilon}_C=1.179D^{0.09}U_G^{-0.13}{\mu}_L^{0.04}$.

영상처리기술을 이용한 영상수위계 개발 (Development of the Image Stage Gauge using the Image Process Technique)

  • 김원;김치영;김동구;이찬주
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.500-504
    • /
    • 2006
  • 하천 수위 측정을 위해서 우물통을 기본으로 하는 부자식, 초음파식, 기포식, 압력식, 레이다식 등 다양한 장비가 사용되고 있다. 이와 같은 장비는 모두 간접적인 방법으로 수위를 측정하기 때문에 기준값을 바탕으로 보정이 필요하며, 장비의 특성에 따라 여러 가지 장단점을 지니고 있다. 부자식의 경우 오래 전부터 사용되어 안정적으로 수위를 측정할 수 있는 것으로 평가되고는 있으나 우물통 막힘 등으로 인해 오측 혹은 결측이 발생하는 경우가 있다. 최근에 많이 사용되고 있는 센서식 장비의 경우에는 센서에 대한 정기적인 보정이 필요하며, 일부 장비의 경우 온도에 따라 측정값이 변화하는 단점이 있다. 수위 측정 방식은 접촉식과 비접촉식으로 나누어 볼 수 있다. 접촉식의 경우 물속에 센서가 위치하고 있기 때문에 홍수시 센서 유실 및 고장의 우려가 있으며, 잦은 고장의 원인이 되기도 한다. 비접촉 방식인 초음파나 레이다 수위계의 경우 온도에 따라 보정이 필요하거나 수면과의 거리에 커지면 오차가 커지는 경향을 지니고 있다. 또한 이와 같은 간접방식에 의한 수위측정 방법은 수위가 많이 변화하는 경우 실제 수위와 측정되는 수위가 일치하는지를 확인하는 것이 불가능한 단점도 있다. 본 연구에서는 최근에 많이 일반화되고 있는 영상처리기술을 이용하여 자동적으로 수위를 측정하는 장비인 영상수위계를 개발하였다. 또한 개발한 영상수위계를 하천 현장에 적용하여 정확성을 평가하고 그 특징을 분석하였다. 영상수위계는 카메라에 의해서 수위표를 촬영하여 직접 수위값으로 변환하는 원리를 사용하고 있어서 기존 수위측정 시설과는 달리 수위표를 직접 눈으로 확인할 수 있는 장점이 있다. 이로 인해 수위표를 육안으로 확인할 수 있기 때문에 측정된 수위를 검증할 수 있어 수위측정의 정확성을 한층 높일 수 있다. 그리고 수위표 영상과 더불어 수위표 주변의 전체 영상을 동시에 촬영하여 실시간으로 전송하기 때문에 홍수시 하천 상황에 대한 모니터링 목적으로 사용될 수 있다. 영상수위계는 우물통 등을 이용하는 기존 방법과 비교하여 구조물이 필요 없어 설치 비용이 저렴하고, 영상에 의한 하천 모니터링 기능을 자체적으로 가지고 있기 때문에 효율적이라고 할 수 있다.

  • PDF

영상수위계 실용화 (Practical Application of Image Stage Gauge)

  • 김원;김치영;이찬주;김동구
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2007년도 학술발표회 논문집
    • /
    • pp.560-564
    • /
    • 2007
  • 하천 수위 측정을 위해서 우물통을 기본으로 하는 부자식, 초음파식, 기포식, 압력식, 레이다식 등 다양한 장비가 사용되고 있다. 이와 같은 장비는 모두 간접적인 방법으로 수위를 측정하기 때문에 기준값을 바탕으로 보정이 필요하며, 장비의 특성에 따라 여러 가지 장단점을 지니고 있다. 부자식의 경우 오래 전부터 사용되어 안정적으로 수위를 측정할 수 있는 것으로 평가되고는 있으나 우물통 막힘 등으로 인해 오측 혹은 결측이 발생하는 경우가 있다. 최근에 많이 사용되고 있는 센서식 장비의 경우에는 센서에 대한 정기적인 보정이 필요하며, 일부 장비의 경우 온도에 따라 측정값이 변화하는 단점이 있다. 수위 측정 방식은 접촉식과 비접촉식으로 나누어 볼 수 있다. 접촉식의 경우 물속에 센서가 위치하고 있기 때문에 홍수시 센서 유실 및 고장의 우려가 있으며, 잦은 고장의 원인이 되기도 한다. 비접촉 방식인 초음파나 레이다 수위계의 경우 온도에 따라 보정이 필요하거나 수면과의 거리에 커지면 오차가 커지는 경향을 지니고 있다. 또한 이와 같은 간접방식에 의한 수위측정 방법은 수위가 많이 변화하는 경우 실제 수위와 측정되는 수위가 일치하는지를 확인하는 것이 불가능한 단점도 있다. 본 연구에서는 최근에 많이 일반화되고 있는 영상처리 기술을 이용하여 자동적으로 수위를 측정하는 장비인 영상수위계를 개발하였다. 영상수위계는 카메라(CCTV 포함)에 의해서 수위표를 촬영하여 직접 수위값으로 변환하는 원리를 사용하고 있어서 기존 수위측정 시설과는 달리 수위표를 직접 눈으로 확인할 수 있는 장점이 있다. 이로 인해 수위표를 육안으로 확인할 수 있기 때문에 측정된 수위를 검증할 수 있어 수위측정의 정확성을 한층 높일 수 있다. 그리고 수위표 영상과 더불어 수위표 주변의 전체 영상을 동시에 촬영하여 실시간으로 전송하기 때문에 홍수시 하천 상황에 대한 모니터링 목적으로 사용될 수 있다. 본 연구에서 개발한 영상수위계는 한강홍수통제소 관할의 전류, 청담대교 등 4개소 낙동강 홍수통제소 2개소, 지자체 등에 적용되었으며, 적용 결과 비교적 안정적이면서 정확하게 수위를 측정하는 것으로 나타났다. 한편 기존 CCD 카메라 이외에 CCTV를 이용한 영상수위계를 개발하여 영상의 화질 개선뿐 아니라 하천화상 감시 기능을 강화하였다.

  • PDF

고점성 낮은표면장력 매체 기포탑에서 열전달 (Heat Transfer in Bubble Columns with High Viscous and Low Surface Tension Media)

  • 김완태;임대호;강용
    • Korean Chemical Engineering Research
    • /
    • 제52권4호
    • /
    • pp.516-521
    • /
    • 2014
  • 고점성이며 낮은 표면장력 매체로 구성된 기포탑에서 축방향 국부 열전달 계수와 총괄 열전달 계수에 대해 고찰하였다. 기체공탑유속(0.02~0.10 m/s), 액체 점도($0.1{\sim}0.3Pa{\cdot}s$) 그리고 액체 표면장력($66.1{\sim}72.9{\times}10^{-3}N/m$)이 국부 및 총괄 열전달 계수에 미치는 영향을 검토하였다. 열전달 영역은 기포탑 내부 열원과 기포탑 간의 열전달계로 구성하였다. 즉, 기포탑의 중앙에 수직 열원을 설치하여 내부 열원으로 하였다. 열전달 계수는 주어진 운전조건에서 열원에 제공되는 열량과 내부 열원과 기포탑 간의 온도차를 연속적으로 측정하여 결정하였다. 국부 열전달 계수는 기체공탑유속이 증가함에 따라 증가하였으나 기체 분산판으로 부터의 축방향 거리가 증가함에 따라, 액체의 표면장력이 증가함에 따라 감소하였다. 총괄 열전달 계수는 기체공탑유속이 증가함에 따라 증가하였으나 액상의 점도와 표면장력이 증가함에 따라서는 감소하였다. 총괄 열전달 계수는 기체공탑유속, 액상의 점도와 표면장력의 함수로 상관계수 0.91의 상관식을 얻을 수 있었으며 넛셀 수, 레이놀즈 수, 플란틀 수 그리고 웨버 수의 함수로 상관계수 0.92의 상관식으로 나타낼 수 있었다. $$h=2502U^{0.236}_{G}{\mu}^{-0.250}_{L}{\sigma}^{-0.028}_L$$ $$Nu=325Re^{0.180}Pr^{-0.067}We^{0.028}$$.