• Title/Summary/Keyword: 기초 강성

Search Result 579, Processing Time 0.031 seconds

Dispersing Stress under Geogrid-Mattress Foundation (지오그리드 매트리스기호의 전파듣력에 관한 연구)

  • Ju, Jae-U;Jang, Yong-Chae;Park, Jong-Beom
    • Geotechnical Engineering
    • /
    • v.14 no.4
    • /
    • pp.117-128
    • /
    • 1998
  • Solid mattress foundation using geogrid has often been used on soft grounds to increase the bearing capacity, and its effect has received much recognition. Geogrid-mattress system is the method of construction which increases the bearing capacity and the effect of controlling settlement by dispersing load to wider foundation through its stiffness. But ifs mechanism has not been examined exactly yet. considered to be influential factors in the experiments. As a result of the experiments, the characteristic of dispersing stress under mattress foundations was understood and the way of calculating the bearing capacity in designing the mattress foundations was suggested.

  • PDF

Safety Factor of Rigid Sewer Pipe by Different Types of Foundation and Backfill (기초형식 및 뒤채움재 종류별 강성관용 하수관거의 안전율)

  • Lee, Kwan-Ho;Kim, Seong-Kyum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.606-612
    • /
    • 2019
  • The main causes of subsidence and sinkholes in the lower part of urban roads are sewage line foundation and inadequate compaction of backfill material. This leads to many problems, such as the breakage of joints in sewer pipes, poor connection, pipe breakage, and cracks. To solve this problem, the support factor related to the sewer foundation and the safety factor according to the excavation depth were evaluated. For the foundation of rigidity tolerance, crushed stone foundation, and abandoned concrete foundation, a recently newly developed site assembly-type lightweight plastic foundation were used. Backfill materials were applied on site (sandy soil and clayey soil) and fluid backfill was recycled onsite. To evaluate the depth of excavation and the safety factor of each sewer pipe foundation, the design load considering the load factor and the support factor was evaluated. The support coefficients were 0.377 for a crushed stone foundation, 0.243 and 0.220 for an abandoned concrete foundation ($180^{\circ}$ and $120^{\circ}$), and 0.231 for a lightweight plastic foundation and fluid backfill. Overall, the safety factor was low when using the crushed stone foundation, and the safety rate was the highest when the foreclosed concrete foundation ($180^{\circ}$) was used. In addition, when the combination of lightweight plastic and fluid backfill materials was used, the safety factor was higher than that of abandoned concrete foundation ($120^{\circ}$), which means that the newly developed lightweight plastic foundation can be used as another alternative base of a steel pipe.

너비감소 HDS집합체의 탄성강성도 해석

  • 송기남
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05c
    • /
    • pp.27-32
    • /
    • 1996
  • 공학보 이론과 strain energy에 기초한 Castiliano의 제2정리를 이용하여 두께감소 holddown spring(HDS) 집합체의 탄성강성도를 해석적으로 구할 수 있는 방법을 제시하였고 아울러 보의 굽힘 모우멘트. 전단력, 축력등에의한 모든 strain energy를 고려하여 탄성강성도 식을 유도하였다. KOFA형 HDS과 동일한 칫수 설계 공간을 갖도록 고안된 너비감소 HDS에 대해서 유도한 식으로부터 탄성강성도를 계산하고 분석하였다. 너비감소 HDS의 탄성강성도는 KOFA HDS의 탄성강성도 보다 약32-33%이상 높았으며 전단력과 축력이 탄성강성도에 미치는 영향은 약 0.15-0.21%정도였다.

  • PDF

Stiffener Elements of Eccentrically Stiffened Plate/Shell (판 및 셸의 편심 보강 유한 요소)

  • 김용우;박건순;민옥기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.3
    • /
    • pp.771-788
    • /
    • 1991
  • 본 연구에서는 편심된 강성 강화 부재가 붙어 있는 얇은 판 또는 얇은 셸에 대해 유한 요소 해석을 할 때, 편심된 강성 강화 부재를 개별된 요소로서 정확히 묘사 할 수 있도록, 일반적인 보 이론을 기초로 하여 2개의 절점을 갖고, 각 절점당 6자유 도를 갖는 3차원 편심 보 요소(offset beam element)에 대하여 수식화하여 변위와 응 력을 계산한다.

A Study on Settlement according to Height and Ground stiffness on the MSEW on the IPM Bridge (토압분리형 교량의 보강토옹벽의 높이와 기초지반 강성에 따른 침하량 검토)

  • Park, Min-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.399-409
    • /
    • 2018
  • The mechanically stabilized earth wall (MSEW) of the IPM bridge is an important structure that constitutes the bridge, and supports the horizontal earth pressure and approach slab. Therefore, it is necessary to carefully analyze the settlement of MSEW of the IPM bridge. This study examined the settlement according to the height and ground stiffness on the MSEW on the IPM Bridge. According to the design guideline, the IPM Bridge (2016) was designed to have a height of 4.0 ~ 10.0m and the elastic settlement was calculated. The base area and the grounding pressure of the MSE wall increased linearly with the height, and the elastic settlement also increased linearly. In addition, the stiffness of the foundations satisfying the allowable settlement of the approach slab is a N value of 35 or more. The settlement of finite element analysis was estimated to be smaller than the elastic settlement, and the stiffness of the foundation ground satisfied the allowable settlement of the approach slab above N value of 20. Because the elastic settlement of the MSEW of the IPM Bridge was overestimated, it will be necessary to examine it carefully by finite element analysis.

Dynamic Analysis of 3-D Rigid Foundations by Boundary Elements (강성기초의 3차원 동적 경계요소해석)

  • Lee, Chan Woo;Kim, Moon Kyum;Hwang, Hak Joo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.5
    • /
    • pp.53-65
    • /
    • 1993
  • In this work the dynamic response of 3-D arbitrarily shaped rigid massless foundation is numerically obtained using boundary element under non-relaxed boundary condition. The problem is formulated in time domain by the boundary element method. The fundamental solutions used in this work are the Stokes solutions of the three dimensional elastodynamics. This method has advantages over frequency domain techniques in that it provides in a natural and direct way the time history of the response and forms the basis for elct:ension to nonlinear problems. This work is verified and can be used for practical purpose.

  • PDF

Pile-cap Connection Behavior Dependent on the Connecting Method between PHC pile and Footing (PHC말뚝과 확대기초 연결방법에 따른 접합부 거동)

  • Bang, Jin-Wook;Oh, Sang-Jin;Lee, Seung-Soo;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.25-32
    • /
    • 2016
  • The pile-cap connection part which transfers foundation loads through pile body is critical element regarding flexural and shear force because the change of area, stress, and stiffness occurs in the this region suddenly. The purpose of this study is to investigate the structural behavior of pile-cap connection dependent on fabrication methods using conventional PHC pile and composite PHC pile. A series of test under cyclic lateral load was performed and the connection behavior was discussed. From the test results, it was found that the initial rotational stiffness of pile-cap connection was affected by the length of pile-head inserted in footing and the location of longitudinal reinforcing bars. The types of pile and location of longitudinal reinforcing bars governed the behavior of pile-cap connection regarding load-carrying capacity, ductility, and energy dissipation.

Analysis on the Seismic Load Reduction Effect of a Ground by Considering Pile Strength (말뚝 강성을 고려한 지반의 지진하중 저감 효과에 관한 해석 연구)

  • Kim, Sang-Yeon;Park, Jong-Bae;Park, Yong-Boo;Kim, Dong-Soo;Lee, Sei-Hyun
    • Land and Housing Review
    • /
    • v.3 no.4
    • /
    • pp.451-456
    • /
    • 2012
  • In this study, a numerical analysis to evaluate the reduction of seismic load due to pile group was performed and compared the peak ground acceleration(PGA) measured at free-field and foundation. The special attention was given to the amplification of seismic acceleration on the foundation due to the pile effects. The analysis considering pile effects was carried out for 4, 8 and 12 piles with same condition by PLAXIS 2D Dynamics. Based on the analysis results, it is found that the overall reduction in seismic load due to foundation and reduction rates are similar irrespective of pile numbers. This study gives a possibility for effective design of piled foundation by reducing seismic load about 20~25%.

Design of Mat Foundation by Simplified Flexible Method Using Regression Analysis (회귀분석을 이용한 단순화된 연성법에 의한 전면기초의 설계)

  • Moon, Kyoungtae;Park, Sangyeol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.1
    • /
    • pp.153-164
    • /
    • 2015
  • The methods of design of mat foundation may be classified as the rigid method and the flexible method according to the assumptions used. In the rigid method, the mat is assumed to be infinitely rigid and the contact pressure is assumed planar distribution. However, the contact pressure is not planar but curved surface because the real mat is not rigid. Therefore, it is not precise to analyze the mat foundation using the rigid method, and so there is no choice but to accept an error. On the other hand, in the flexible method, the mat is considered as the plate on the elastic foundation. This elastic plate theory is for the infinite plate acting a concentrated load on the elastic foundation. However, the functions for the moment, shear, and the deflection by the flexible method are very complex, there are many difficulties for the designer to use them. Also, it is impossible to use the design aid figures as a substitute of the complex functions, because they do not cover the values at the critical sections for the moment and shear. Therefore, in this research, the simplified functions for the moment, shear, and the deflection are proposed by regression analysis for an designer to use easily the flexible method. The simplified functions are very accurate and very ease to use.

Resistance Increasing Factor of Connected-pile Foundation for Transmission Tower in Clay (점토지반에 근입된 송전철탑 연결형 말뚝기초의 저항력증가계수)

  • Kyung, Doo-Hyun;Lee, Jun-Hwan;Paik, Kyu-Ho;Kim, Dae-Hong
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.8
    • /
    • pp.31-41
    • /
    • 2012
  • Pile foundation for transmission tower constructed in weak ground can cause the damage of the tower due to the different settlement between the foundations. In Japan and USA, connected-pile foundations whose 4 foundations are connected each other by beams were used for transmission tower (TEPCO 1988, IEEE 2001). Resistance increasing factors for connected-pile foundation signify increasing amount of resistance due to the effect of connected-pile material. In this study, we performed model lateral load tests of connected-pile foundations for transmission tower and found the resistance increasing factors for connected-pile foundation. The tests were performed in silty clay, and the resistance increasing factors were founded in various conditions that lateral load directions and height, the stiffness of beams in the connected-pile foundations were changed. The resistance increasing factors from our research were presented as a function of normal lateral loading height and normal stiffness of the connected-pile material. The resistances which were estimated from the resistance increasing factors were similar to measured values.