• Title/Summary/Keyword: 기성

Search Result 1,549, Processing Time 0.036 seconds

Simple Fabrication of Micromixer Based on Non-Equilibrium Electrokinetics in Micro/Nano Hybrid Fluidic System (단순공정으로 제작된 마이크로/나노 하이브리드 채널의 불균형 동전기성을 이용한 미세혼합기 연구)

  • Yu, Samuel;Kim, Sun-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.385-390
    • /
    • 2011
  • In this study, we developed a micromixer based on the non-equilibrium electrokinetics at the junction of a microchannel and nanochannel. Two fluid streams were mixed by an electro-osmotic flow and a vortex flow created as a result of the non-equilibrium electrokinetics at the junction of the microchannel and nanochannel. Initially, the microchannel was fabricated using Polydimethylsiloxane (PDMS) by the general soft lithography process and the nanochannel was created at a specific position on the microchannel by applying a high voltage. To evaluate the mixing performance of the micromixer, fluorescent distribution was analyzed by using the fluorescent dye, Rhodamine B. About 90% mixing was achieved with this novel micromixer, and this micromixer can be used in microsystems for biochemical sample analysis.

New Construction Accident Index Based on Number of Accident and Progress Payments (건설기성과 재해자수에 기반한 건설재해지표 산정방식)

  • Yi, Kyoo-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.3
    • /
    • pp.293-303
    • /
    • 2022
  • In construction work, it can be difficult to know the exact number of full-time workers, so the accident rate is calculated using the approximate number of full-time workers. In addition, as the accident rate calculation is performed based on the assumption that the number of accidents is proportional to the approximate number of workers, the reliability of the calculation result may be questionable. This study proposed a new indicator for accident level based on the progress payment and the number of injuries. The accident-progress ratio, which can be calculated by simply dividing the number of injuries by progress payment, can replace the existing accident rate index or be used as an auxiliary indicator of the accident level. The correlation coefficient between the number of injuries and the progress payment was higher than that between the number of injuries and the number of construction workers. In addition, over the past 10 years, the accident rate has been increasing, whereas the accident-progress ratio has showed a decreasing tendency. This might leave room for different interpretations of the annual variation in the accident level in the construction industry.

A MORPHOMETRIC STUDY OF THE MAXILLARY PRIMARY FIRST MOLARS USING THREE-DIMENSIONAL SCANNER (3차원 스캐너를 이용한 상악 제1유구치 치관의 크기와 형태에 관한 연구)

  • Lee, Jong-Beom;Kim, Chong-Chul;Hahn, Se-Hyun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.643-652
    • /
    • 2006
  • The purpose of this study was to elucidate the size and morphologic characteristics of maxillary primary first molars in Korean children using three-dimensional laser scanner and compare three-dimensional image with preformed stainless steel crown. Scanned three-dimensional images of dental cast taken from 132 children(male 62, female 70) by three-dimensional laser scanner(Breuckmann opto-Top HE100, INUS, Korea) were used. Mesiodistal diameter, buccolingual diameter, occlusogingival height and crown shape of each image were calculated by Rapidform 2004 program(INUS, Korea). The values were statistically compared by independent samples t-test with 95% of significant level. The results were as follows : 1. No significant difference in crown size was found between left and right maxillay primary first molar(p>0.05). 2, Significant difference in mesiodistal diameter, buccolingual diameter, buccal occlusogingival height was found between male and female (p<0.05), and crown size of male was bigger than that of female. 3. Average image of maxillay primary first molar was shaped three-dimensionally and measured. In comparison with 3M stainless steel crown, this image was similar with No.4 or No.5 SS crown in male, No.4 in female. In comparison with ILSUNG SS crown, this image was similar with No.5 in male, No.4 in female. 4 Mesiolingual line angle area, distolingual line angle area and buccogingival ridge were more obvious in average image than 3M stainless steel crown. ILSUNG SS crown was more square and had longer mesiodistal diameter than average 3D image.

  • PDF

Comparison of Crown Shape and Amount of Tooth Reduction for Primary Anterior Prefabricated Crowns (유전치 기성 크라운의 형태 및 치질 삭제량 비교)

  • Kim, Soyoung;Lim, Youjin;Lee, Sangho;Lee, Nanyoung;Jih, Myeongkwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.1
    • /
    • pp.64-75
    • /
    • 2019
  • The purpose of this study was to obtain instructions for size selection of prefabricated crown and tooth reduction by 3-dimensional analysis of the size and shape of the maxillary primary central and lateral incisors and prefabricated crowns (celluloid strip, resin veneered stainless steel, and zirconia crowns). The maxillary primary central and lateral incisors of 300 Korean children was scanned with three types of prefabricated crown to create standard three-dimensional tooth models and prefabricated crowns. The shapes of the prefabricated crowns and natural teeth were compared according to four parameters (mesio-distal width, height, labio-palatal width, and labial surface curvature coefficient) and calculated the amount of tooth reduction required for each prefabricated crown. The size 2 resin veneered stainless steel crown, size 1 zirconia crown, and size 2 celluloid strip crown were most similar in shape to the primary central incisor. The size 3 rein veneered stainless steel crown, size 2 zirconia crown, and size 3 celluloid strip crown were most similar to the primary lateral incisor. The amount of tooth reduction was similar in both maxillary primary central and lateral incisors. The incisal reduction was greatest for the zirconia crown. At the proximal surface, the zirconia and celluloid strip crowns required a similar amount of tooth reduction, but more than the resin veneered stainless steel crown. The labial surface reduction was greatest for the zirconia crown. The degree of lingual surface reduction was not significant among the three prefabricated crowns. Among the assessment parameters, mesio-distal crown width was the most important for choosing a prefabricated crown closest to the actual size of the natural crown.

Effects of Culture Environments on Alkaline Protease Biosynthesis in Streptomyces sp. (Streptomyces속 세균에서 호염기성 단백질 분해효소 생합성에 미치는 배양환경의 영향)

  • 노용택;김종웅;이계준
    • Korean Journal of Microbiology
    • /
    • v.28 no.2
    • /
    • pp.162-168
    • /
    • 1990
  • The aims of the present study were to evaluate the effects of culture conditions on the biosynthesis of extra-cellular alkaline protease in Streptomyces sp. The formation of aerial mycelia and spores were compared with the protease production in order to know the relations between the alkaline protease and the cell differentiation. As results, it was found that substrate concentration was very critical to regulate the formation of the protease, aerial mycelia, and spores, which were resulted from the changes of culture pH to acid. When the culture pH was adjusted with phosphate buffer from pH 6 to pH 9, the alkaline protease production was increased as the culture pH increased whereas aerial mycelia and spore formation were reversely related to the culture pH. Therefore, it was thought that the culture pH was an important factor to regulate the alkaline protease synthesis.

  • PDF

Moving Distance Measurement System using a Accelerometer Sensor (가속도 센서를 이용한 이동거리 측정 시스템)

  • Park, Seung-Hun;Lee, Jung-Hoon;Kim, Sung-Woo;Lim, Jae-Hwan;Ryu, Jee-Youl
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.6
    • /
    • pp.1300-1305
    • /
    • 2012
  • In this research, we propose a momentum measurement system using the accelerometer sensor, MCU, and Bluetooth to measure the exact momentum. The proposed system can figure out information for the real time travel distance. We performed various experiments, and analyzed the results using the proposed momentum measurement system. In the simulation experiments, we compared the reliability and accuracy for the existing momentum measurement systems from the analyzed results. The proposed system showed travel distance error of less than 8% as compared to the existing system with the error of approximately 13%. We expect that the proposed system apply to the commercial products.

Solution of the SAAF Neutron Transport Equation with the Diffusion Synthetic Acceleration (확산 가속법을 이용한 SAAF 중성자 수송 방정식의 해법)

  • Noh, Tae-Wan;Kim, Sung-Jin
    • Journal of Energy Engineering
    • /
    • v.17 no.4
    • /
    • pp.233-240
    • /
    • 2008
  • Conventionally, the second-order self-adjoint neutron transport equations have been studied using the even parity and the odd parity equations. Recently, however, the SAAF(self-adjoint angular flux) form of neutron transport equation has been introduced as a new option for the second-order self-adjoint equations. In this paper we validated the SAAF equation mathematically and clarified how it relates with the existing even and odd parity equations. We also developed a second-order SAAF differencing formula including DSA(diffusion synthetic acceleration) from the first-order difference equations. Numerical result is attached to show that the proposed methods increases accuracy with effective computational effort.

Micro-CT Evaluation of Stainless Steel Crowns on Extracted Primary Molars (Micro-CT를 이용한 발거된 유구치의 기성금속관 평가)

  • Jung, Boram;Shin, Jonghyun;Jeong, Taesung;Kim, Jiyeon;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.1
    • /
    • pp.53-61
    • /
    • 2015
  • This study was conducted for the purpose of evaluating the stainless steel crowns on extracted primary molars and thus identifying frequent errors and defects. Visual assessment and micro-computed tomography (micro-CT) image analysis were performed on 97 primary molars for evaluation of the state of marginal adaptation, cement loss, secondary caries, ledge formation, attritive perforation and marginal polishing defect. The results were as follows: In the examination of object teeth by evaluation criteria, cement loss was found most frequently (98%), followed by secondary caries (42.3%), marginal polishing defect (41.2%), ledge formation (29.9%) and attritive perforation (17.5%), in this order. The cement loss at the margins showed a significant relationship with marginal gap and secondary caries: the larger the marginal gap is, the more frequent is the cement loss (p < 0.05). The average marginal gap was $0.31{\pm}0.26mm$ and showed the highest value in the maxillary 2nd primary molars. The location of the crown margin above the cementoenamel junction was found most frequently and it was found that the higher the crown margin is located, the less the marginal gap becomes (p < 0.05). In conclusion, it is thought very desirable to pay closer attention to crown margins and shapes for stainless steel crown restoration in order to minimize the marginal gaps and consequent cement loss.

THE STAINLESS STEEL CROWN RESTORATION OF CARIOUS PRIMARY MOLARS WITH HALL TECHNIQUE : A CASE REPORT (Hall technique을 이용한 우식 유구치의 기성 금속관 수복 : 증례보고)

  • Yu, Seong-Goo;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.2
    • /
    • pp.199-205
    • /
    • 2012
  • Although the stainless steel crowns have been recognized as the most effective and durable form of restoration for primary molars, they have been regarded by many dentists as having definite demerits such as invasive nature of procedural complexity and behavioral aspects of children. As an alternative to conventional technique of stainless steel crown restoration, the Hall technique was first introduced in 1988, which is characterized by just pushing the pre-contoured, cement filled crown form onto the abutment molar with no local anesthesia, no caries removal, no tooth preparation. According to several reports, this can slow, arrest, or even reverse the progress of caries. In addition, its atraumatic feature gives less discomfort and stress to children than conventional one, which is thought excellent especially in younger children. Also, It has been reported to be effective and acceptable to dentist, child patients and their parents. In this case study, three children with age of 4 years 5 months, 4 years 10 months, 6 years 4 months were treated with stainless steel crowns using Hall technique on first primary molar respectively. The teeth were free from pulpal, periapical pathology. After follow up of about 3 to 6 months period, the results showed clinically successful outcomes without any marked complication in pulp, tooth or soft tissue till now. But, it should be kept in mind that this technique is not proper to every child, every carious molar, or every dentist. Thorough distinction of indicated cases and continuous follow-up check is highly required. Conclusively, Hall technique might be an effective and realistic minimally invasive alternative for the carious primary molars especially in younger or disabled children, despite potential doubts on its efficacy and some definite limitations.

$^{13}C$ NMR Analysis for the Characterization of Heme Electronic/Molecular Structure in Horse Myoglobin Cyanide (Myoglobin 시안 단백질에 포함된 Heme에 대한 전자 및 분자구조 규명을 위한 $^{13}C$ NMR분석)

  • Lee, Kang-Bong;Kweon, Jee-Hye;Lee, Ho-Jin;Kim, Young-Man;Choi, Young-Sang
    • Analytical Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.73-78
    • /
    • 1998
  • The reverse detection heteronuclear multiple quantum coherence, HMQC study of metcyano complex of horse myoglobin(MbCN) has provided the complete assignment of hyperfine shifted resonances of heme carbons attached with proton(s). The application of HMQC experiment to the paramagnetic low-spin MbCN gives clear $^1H$ and $^{13}C$ coherences for the paramagnetic amino acid residues as well as heme side chains, and can be extended to the low-spin paramagnetic hemoprotein derivative for the assignment of natural abundance $^{13}C$ resonances. This assignment strategy can avoid possible ambiguities that may result from the sole utilization of $^1H$ nuclear Overhauser effect for the assignment of heme $^1H$ signals resonating in the diamagnetic region. The resulting 2,4-vinyl ${\alpha}$-carbons and 7-propionate ${\beta}$-carbon follow anomalous anti-Curie behavior, and are indicative of incoplanarity with heme plane. Magnetic/electronic asymmetry of heme induced by proximal histidine(His) makes spread that the hyperfine shifted heme carbon resonances over the range of 250 ppm at $25^{\circ}C$. These heme carbon resonances would be the much more sensitive probe than those of proton resonances in analyzing the nature of heme electronic structure of myoglobin.

  • PDF