DOI QR코드

DOI QR Code

Micro-CT Evaluation of Stainless Steel Crowns on Extracted Primary Molars

Micro-CT를 이용한 발거된 유구치의 기성금속관 평가

  • Jung, Boram (Department of Pediatric Dentistry, College of Dentistry, Pusan National University) ;
  • Shin, Jonghyun (Department of Pediatric Dentistry, College of Dentistry, Pusan National University) ;
  • Jeong, Taesung (Department of Pediatric Dentistry, College of Dentistry, Pusan National University) ;
  • Kim, Jiyeon (Department of Pediatric Dentistry, College of Dentistry, Pusan National University) ;
  • Kim, Shin (Department of Pediatric Dentistry, College of Dentistry, Pusan National University)
  • 정보람 (부산대학교 치의학전문대학원 소아치과학교실) ;
  • 신종현 (부산대학교 치의학전문대학원 소아치과학교실) ;
  • 정태성 (부산대학교 치의학전문대학원 소아치과학교실) ;
  • 김지연 (부산대학교 치의학전문대학원 소아치과학교실) ;
  • 김신 (부산대학교 치의학전문대학원 소아치과학교실)
  • Received : 2014.11.11
  • Accepted : 2015.01.13
  • Published : 2015.02.28

Abstract

This study was conducted for the purpose of evaluating the stainless steel crowns on extracted primary molars and thus identifying frequent errors and defects. Visual assessment and micro-computed tomography (micro-CT) image analysis were performed on 97 primary molars for evaluation of the state of marginal adaptation, cement loss, secondary caries, ledge formation, attritive perforation and marginal polishing defect. The results were as follows: In the examination of object teeth by evaluation criteria, cement loss was found most frequently (98%), followed by secondary caries (42.3%), marginal polishing defect (41.2%), ledge formation (29.9%) and attritive perforation (17.5%), in this order. The cement loss at the margins showed a significant relationship with marginal gap and secondary caries: the larger the marginal gap is, the more frequent is the cement loss (p < 0.05). The average marginal gap was $0.31{\pm}0.26mm$ and showed the highest value in the maxillary 2nd primary molars. The location of the crown margin above the cementoenamel junction was found most frequently and it was found that the higher the crown margin is located, the less the marginal gap becomes (p < 0.05). In conclusion, it is thought very desirable to pay closer attention to crown margins and shapes for stainless steel crown restoration in order to minimize the marginal gaps and consequent cement loss.

소아치과 임상에서 기성금속관 수복은 매우 높은 활용성과 사용빈도에도 불구하고 완벽하고 정밀한 수복이 쉽지 않은 항목으로 판단된다. 불량한 변연 적합, 변연부 치태 침착, 인접 영구치의 맹출 장애, 접착제 소실 및 이차 우식, 부적절한 지대치 삭제, 교합면 천공 등이 임상적으로 흔히 관찰되는 문제점들이다. 본 연구는 기성금속관이 장착된 상태로 발치된 유구치를 대상으로 수복 상태를 평가해 봄으로써, 빈번한 결함과 착오들을 찾아낼 목적으로 시도되었다. 부산대학교 치과병원 소아치과에서 발치된 기성금속관 수복 유구치 97개를 대상으로 육안적 평가와 micro-computed tomography(micro-CT) 영상을 분석하였다. 변연 적합도, 접착제 소실, 이차우식, 교모성 천공, 변연부 연마 결함, 선반(ledge) 형성 등의 항목으로 수복상태를 평가하여, 다음과 같은 결과를 얻었다. 조사항목들을 대상치아 기준으로 보았을 때, 접착제 소실이 가장 빈번하였으며(98%), 뒤를 이어 이차우식(42.3%), 변연부 연마 결함(41.2%), 선반(ledge) 형성(29.9%), 교모성 천공(17.5%)의 순으로 나타났다. 변연 간격이 클수록 접착제 소실이 증가하는 경향을 보였고, 접착재 소실은 변연 간격 및 이차 우식과 유의한 상관성을 보였다. 평균 변연간격은 $0.31{\pm}0.26mm$ 였으며, 상악 제2 유구치에서 가장 크게 나타났다. 변연이 백악법랑경계 상방에 위치하는 경우가 가장 많았고, 변연이 치관 상방에 위치할수록 변연 간격은 작게 나타났다(p < 0.05).

Keywords

References

  1. Seale NS : The use of stainless steel crowns. Pediatr Dent, 24:501-505, 2002.
  2. Randall RC : Preformed metal crowns for primary and permanent molar teeth: review of the literature. Pediatr Dent, 24:489-500, 2002.
  3. Rector JA, Mitchell RJ, Spedding RH : The influence of tooth preparation and crown manipulation on the mechnical retention of stainless steel crowns. ASDC J Dent Child, 52:422-427, 1985.
  4. Spedding RH : Two principles for improving the adaptation of stainless steel crowns to primary molars. Dent Clin North Am, 28:157-175, 1984.
  5. Henderson HZ : Evaluation of the preformed stainless steel crown. ASDC J Dent Child, 40:353-358, 1973.
  6. Myers DR : A clinical study of the response of the gingival tissue surrounding stainless steel crowns. ASDC J Dent Child, 42:281-284, 1975.
  7. Croll TP, Epstein DW, Castaldi CR : Marginal adaptation of stainless steel crowns. Pediatr Dent, 25:249-252, 2003.
  8. Memarpour M, Mesbahi M, Rahimi M, et al. : Microleakage of adhesive and nonadhesive luting cements for stainless steel crowns. Pediatr Dent, 33:501-504, 2011.
  9. Shiflett K, White SN : Microleakage of cements for stainless steel crowns. Pediatr Dent, 19:262-266, 1997.
  10. Yilmaz Y, Kara NB, Sahin H, et al. : Wear and repair of stainless steel crowns. Eur J Paediatr Dent, 12:25-30, 2011.
  11. Pinkham JR, Casamassimo PS, Fields HW, et al. : Pediatric Dentistry: Infancy Through Adolescence, 4th ed. ELSEVIER SAUNDERS, 2005.
  12. Salama FS : A study of the stainless steel crown errors: a suggestion for the modification of crown margins extension. Cairo Dental Journal, 12:153-161, 1996.
  13. Yu SG, Jeong TS, Kim S : The stainless steel crown restoration of carious primary molars with Hall technique : A Case Report. J Korean Acad Pediatr Dent, 39:199-205, 2012. https://doi.org/10.5933/JKAPD.2012.39.2.199
  14. Adair SM, Byrd RL : Evaluation of practitionerdeveloped criteria for assessing the quality of stainless steel crown restorations. J Pedod, 7:291-299, 1983.
  15. Sharaf AA, Farsi NM : A clinical and radiographic evaluation of stainless steel crowns for primary molars. J Dent, 32:27-33, 2004.
  16. Larson TD : The clinical significance of marginal fit. Northwest Dent, 91:22-29, 2012.
  17. Sorensen JA : A standardized method for determination of crown margin fidelity. J Prosthet Dent, 64:18-24, 1990. https://doi.org/10.1016/0022-3913(90)90147-5
  18. Borba M, Cesar PF, Della Bona A, et al. : Adaptation of all-ceramic fixed partial dentures. Dent Mater, 27:1119-1126, 2011. https://doi.org/10.1016/j.dental.2011.08.004
  19. Mitchell CA, Pintado MR, Douglas WH. : Nondestructive, in vitro quantification of crown margins. J Prosthet Dent, 85:575-584, 2001. https://doi.org/10.1067/mpr.2001.114268
  20. Pelekanos S, Koumanou M, Eliades G, et al. : Micro-CT evaluation of the marginal fit of different In-Ceram alumina copings. Eur J Esthet Dent, 4:278-292, 2009.
  21. Woo JH, Jang CH, Kim CC, et al. : Marginal adaptation of stainless steel in posterior primary tooth. J Korean Acad Pediatr Dent, 34:27-35, 2007.
  22. Croll TP : Permanent molar stainless steel crown restoration. Quintessence Int, 18:313-312, 1987.
  23. Croll TP : Preformed posterior stainless steel crowns: An update. Compend Contin Educ Dent, 20:89-92, 1999.
  24. Croll TP, Castaldi CR : The preformed stainless steel crown for restoration of permanent posterior teeth in special cases. J Am Dent Assoc, 97:644-649, 1978. https://doi.org/10.14219/jada.archive.1978.0368
  25. Shiflett K, White SN : Microleakage of cements for stainless steel crowns. Pediatr Dent, 19:262-266, 1997.
  26. Piwowarczyk A, Lauer HC, Sorensen JA : Microleakage of various cementing agents for full cast crowns. Dent Mater, 21:445-453, 2004.
  27. White SN, Yu Z, Sangsurasak S, et al. : In vivo microleakage of luting cements for cast crowns. J Prosthet Dent, 71:333-338, 1994. https://doi.org/10.1016/0022-3913(94)90090-6
  28. Berg JH, Pettey DE, Hutchins MO : Microleakage of three luting agents used with stainless steel crowns. Pediatr Dent, 10:195-198, 1988.
  29. Seraj B, Shahrabi M, Javad Kharazifard M, et al. : Microleakage of stainless steel crowns placed on intact and extensively destroyed primary first molars: an in vitro study. Pediatr Dent, 33:525-528, 2011.
  30. Dean JA, Avery DR, McDonald RE : Dentistry for the Child and Adolescent, 9th ed. Mosby, 2011.
  31. Kindelan SA, Day P, Fayle SA, et al. : UK National Clinical Guidelines in Paediatric Dentistry: stainless steel preformed crowns for primary molars. Int J Paediatr Dent, 18:20-28, 2008. https://doi.org/10.1111/j.1365-263X.2008.00935.x
  32. Wiland L : The accurate contouring of preformed crowns. J Prosthet Dent, 29:221-224, 1973. https://doi.org/10.1016/0022-3913(73)90117-0
  33. Han EO, Lee JH, Jeong TS, et al. : A morphometric study of the preformed stainless steel crowns of some brands. J Korean Acad Pediatr Dent, 39:145-152, 2012. https://doi.org/10.5933/JKAPD.2012.39.2.145
  34. Holmes JR, Bayne SC, Sulik WD, et al. : Considerations in measurement of marginal fit. J Prosthet Dent, 62:405-408, 1989. https://doi.org/10.1016/0022-3913(89)90170-4
  35. Lee SK, Kim CC : A study on marginal adaptation of ready-made stainless steel crown to the primary molar. J Korean Acad Pediatr Dent, 23:389-400, 1996.