• 제목/요약/키워드: 그린 리모델링

검색결과 56건 처리시간 0.028초

LEAP 모형을 이용한 건축물의 온실가스 감축 시나리오 분석 - 서울세관건물 그린리모델링 시범사업을 중심으로 - (Analysis of GHG Reduction Scenarios on Building using the LEAP Model - Seoul Main Customs Building Demonstration Project -)

  • 윤영중;김민욱;한준;전의찬
    • 한국기후변화학회지
    • /
    • 제7권3호
    • /
    • pp.341-349
    • /
    • 2016
  • This study is intended to set a greenhouse gas emission scenario based on green remodeling pilot project (Annex building of Seoul Customs Office) using LEAP model, a long-term energy plan analysis model, to calculate the energy saving and greenhouse gas emission till year 2035 as well as to analyze the effect of electric power saving cost. Total 4 scenarios were made, Baseline scenario, assuming the past trend is to be maintained in the future, green remodeling scenario, reflecting actual green remodeling project of Seoul Customs Office, behavior improvement and renewable energy supply, and Total scenario. According to the analysis result, the energy demand in 2035 of Baseline scenario was 6.1% decreased from base year 2013, that of green remodeling scenario was 17.5%, that of behavior improvement and renewable energy supply scenario was 21.1% and that of total scenario was 27.3%. The greenhouse emission of base year 2013 was $878.2tCO_2eq$, and it was expected $826.3tCO_2eq$, approx. 5.9% reduced, in 2035 by Baseline scenario. the cumulative greenhouse gas emission saving of the analyzing period were $-26.5tCO_2eq$ by green remodeling scenario, $2.8k\;tCO_2eq$ by behavior improvement and renewable energy supply scenario, and $2.0k\;tCO_2eq$ by total scenario. In addition the effect of electricity saving cost through energy saving has been estimated, and it was approx. 634 million won by green remodeling scenario and appro. 726 million won by behavior improvement and renewable energy supply scenario. So it is analyzed that of behavior improvement and renewable energy supply scenario would be approx. 12.7% higher than that of green remodeling scenario.

그린리모델링 효과평가를 위한 표준공동주택 정밀에너지해석모델 보정과 검증 (Calibration and Verification of Detailed Prototypical Apartment Building Energy Models for Estimation of Green Remodeling Feasibility)

  • 서동현
    • 토지주택연구
    • /
    • 제15권2호
    • /
    • pp.9-17
    • /
    • 2024
  • 표준건물 에너지모델은 정책, 연구 및 기술개발 등에 다양한 활용성이 있다. 상세 에너지해석용 표준공동주택모델이 서동현 외(2014)에 의해 제안되었으나, 모델의 에너지소비량 예측에 성능 검증용 신뢰성 있는 측정데이터가 없어 충분한 검증이 이루어지지 못하였다. 그러나, 최근 에너지경제연구원(KEEI)에서 매년 발표하는 가구에너지패널조사(HEPS) 데이터를 분석하여 공동주택 벤치마크데이터를 발표한 연구에 힘입어 검증이 가능하게 되었다. 이 연구는 이 검증용 데이터를 이용하여 표준공동주택 에너지모델을 중부지역, 2000년 이전 모델을 기준으로 보정하고, 보정된 모델을 이용하여 지역과 준공년도가 그룹에도 유효한 성능을 보여주는지 검증하였다. 검중에는 중부, 남부 각 5개씩의 대표도시 표준기상데이터가 이용되었고, 18개의 그룹에서 대부분 MBE, cv(RMSE) 기준을 만족하는 결과를 도출하였다.

탄소중립을 위한 주거단지에서의 에너지 전환 동향 (Energy Transition Trend in Residential Complexes for Carbon Neutrality)

  • 이태구;한영해
    • 한국농촌건축학회논문집
    • /
    • 제26권2호
    • /
    • pp.1-8
    • /
    • 2024
  • Carbon neutrality refers to a state in which there is no global increase in CO2 emissions due to human activities. In Korea, for carbon neutrality, green remodeling of existing buildings and customized support tasks for zero energy in new buildings are presented. Germany is showing fundamental changes in energy supply, such as applying renewable energy and higher energy efficiency from nuclear and fossil fuels, which were the existing energy sources. In this study, how Germany establishes policies for carbon neutrality at each state level and the cases applied to increase the energy efficiency of the actually applied residential complexes are analyzed based on this. As a result of the case complex analysis, it was found that the construction direction was being promoted as a zero-energy complex or a carbon-neutral complex by gradually reducing the energy demand in buildings and supplying additional energy with new and renewable energy in the low-energy building distribution in the 1990s. In Germany's ecological complex, energy standards have been strengthened from low-energy architecture to plus-energy architecture over time, and annual heating energy consumption standards and heat transmittance rates for each structure have been achieved at a higher level. The results of this analysis will serve as basic data and derivation of applicable items when planning residential complex development and remodeling of existing buildings for the domestic carbon-neutral goal in the future.

Green Frame의 골조공사 공기 분석 연구 - 공동주택을 중심으로 - (Analysis of Structural Work Scheduling of Green Frame - Focusing on Apartment buildings -)

  • 이성호;김신은;김광희;주진규;김선국
    • 한국건축시공학회지
    • /
    • 제11권3호
    • /
    • pp.301-309
    • /
    • 2011
  • 현재 국내 주택의 근간을 이루는 내력벽식 공동주택은 구조적 한계로 인해 단수명화되고 있다. 이로 인해 발생하는 재건축은 막대한 자원 및 에너지 소비와 건설폐기물로 인한 환경오염을 유발하고 있다. 정부는 이러한 문제 해결의 방안으로 리모델링이 가능한 라멘구조를 유도하는 인센티브 제도를 시행하고 있다. 따라서 새로운 개념을 적용한 라멘구조의 공동주택을 위하여 개발된 복합PC구조인 Green Frame은 내력벽식 및 기존 라멘조식 공동주택이 리모 델링이 어렵다는 단점을 개선할 수 있을 뿐만 아니라 공사기간 단축이 가능할 것이다. 그러므로 본 연구에서는 Green Frame의 특성과 절대공기를 분석하고, 구조별 공동주택의 골조공사 공기와 비교 분석하여 차이점을 규명하였다. 그 결과 Green Frame을 공동주택에 적용할 경우 공기단축이 가능한 것으로 나타났다. 따라서 건설공사에서 공기는 매우 중요한 요소로 향후 성공적인 공동주택의 사업을 위해서 중요한 핵심기술로서의 역할을 할 수 있을 것으로 사료된다.

저탄소 및 장수명 공동주택 구현을 위한 Green Frame(GF)의 타당성 분석 (A Feasibility Study of Green Frame(GF) for the Implementation of Low-carbon Emissions & Long-life Housing)

  • 홍원기;김선국;김형근;윤태호;윤대영;김승일
    • 한국건축시공학회지
    • /
    • 제10권1호
    • /
    • pp.57-63
    • /
    • 2010
  • 현재 우리나라 공동주택의 근간을 이루는 벽식 공동주택은 가변성의 부족, 보수 및 리모델링의 어려움으로 인하여 단수명화되고 있다. 이로 인하여 발생되는 재건축에 의한 경제적 손실 및 환경 문제는 점차 누적되어가고 있으며 이러한 문제는 앞으로 국가적 차원의 난제가 될 것으로 예상된다. 또한 국내 대표 주거공간으로 자리매김하고 있는 공동주택은 앞으로 다양한 사용자의 요구 및 생활양식의 변화를 수용할 수 있어야 한다. 따라서 평면 가변성에 제약이 있는 벽식 공동주택은 앞으로 지양되어야 하며 가변성이 확보된 새로운 형태의 신개념 공동주택의 개발이 필요한 실정이다. 본 연구의 대상이 되는 GF 공동주택은 기존 벽식 공동주택의 단점을 개선하여 공사비 절감과 공사기간 단축을 가능하게 할 것으로 예측되며, 가변성이 확보된 장수명 구조물로서 국가적으로 추진하고 있는 자원 및 에너지 절감 정책에 부응할 것으로 기대된다. 뿐만 아니라 현 정부가 추진하고 있는 저탄소 녹색성장에 발맞추어 국내 건설 산업의 지속가능한 질적 성장을 가능케 하고 기후변화 문제 해결을 위한 CO2 절감 원천기술로 자리매김할 것이다.

노후고등학교의 미래학교 공간구성 정책방향에 관한 연구 - 고교학점제 적용을 위한 공간 재배치 판단을 중심으로 - (A Study on the Policy Direction of Space Composition of the Future School in Old High School - Focused on The Judgment of Space Relocation for the Application of the High School Credit System -)

  • 이재림
    • 교육녹색환경연구
    • /
    • 제21권3호
    • /
    • pp.1-13
    • /
    • 2022
  • 본 연구는 기존 노후 고등학교에 대해 학점제 운영이 가능한 미래학교로서의 공간 혁신을 위해 기존 학교의 공간 구성 및 구조적 문제점을 파악하고 미래 다양한 교수학습이 가능한 학점제 운영 학교로서의 중·장기 배치계획을 수립할 수 있도록 사례 조사를 통해 증.개축 또는 리모델링 판단 준거 도출을 목적으로 실시하였으며, 연구 결과는 다음과 같다. 첫째, 기존 노후 고등학교의 문제점은 대부분 일자형 표준설계도형 단위 건물 중심, 여러 동으로 분산 배치되어 건물 간 연계성이 매우 부족한 것으로 나타났다. 또한, 각 건물의 평면 구성 형식은 교실과 복도 개념의 공간 구성으로 휴식 시간대 학생 교류와 휴식 기능이 이루어질 수 없는 구조로 판단된다. 둘째, 미래학교 공간 혁신을 위한 학점제 운영 고등학교 공간 구성 방향으로는 교과교실제를 전제로 학생 이동에 따른 동선 단축 및 교과 영역 확대 등을 고려할 때 집합형 배치를 반영하여 배치 계획을 수립하여야 한다. 또한 이동 수업에 따른 소통과 교류가 가능한 중심 지역에 휴식과 교류가 가능한 광장형 공간을 제공하는 것이 바람직하다. 더불어 학생 중심 공간인 광장과 연계된 도서관이나 스마트학습실 등 체험 활동이 가능한 다양하고 융통성 있는 공간을 배치한다. 셋째, 노후고등학교 재배치 판단 평가 기준으로는 향후 학급 수를 기준으로 스페이스프로그램을 작성하고 학교 토지 활용에 대한 법적 분석 및 지역 특성을 고려한 토지 이용 효율성 분석을 실시한다. 또한 기존 건물의 각 동별 구조적 특성 및 기존 건물의 노후도를 분석하여 건물 동별 내구연수를 파악하고 교육적 기능성과 함께 개축 또는 리모델링 판단을 위한 기준으로 활용한다. 이와 같은 분석 자료를 토대로 학교시설 복합화 등 학교 공간 전체에 대한 중 장기·토지이용계획 및 공간 배치 계획을 수립한다.