• Title/Summary/Keyword: 국제법위원회

Search Result 128, Processing Time 0.027 seconds

Terms Standardization between the Rules of Diagnosis Radiation Equipment Safety Management and Atomic Energy Law : Problems and Suggestions (진단용 방사선발생장치의 안전관리에 관한 규칙과 원자력법의 용어통일 개선 방향)

  • Kim, Hwa-Gon;Kang, Se-Sik;Kim, Chang-Soo;Park, Cheol-Seo
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.39-46
    • /
    • 2006
  • The rules and terms are described different meaning, in this results the research is accomplished for preventing practical workers from confusion. Atomic law are kept up modification and development in our situation by the ICRP's recommendation, on the other hand, the rules of diagnosis radiation equipment safety managements are modified partial, then resulted in confusion. The study was comparison between the rules of diagnosis radiation equipment safety management and atomic energy law, and the modification items obtained were as follows. 1. With each other different the terms and units are used. With the exception of special terms for affairs usage, it is needless to say that common term uniformity is standardized. The standardization of rules and guidance have not need to confusion radiological practical workers. 2. The following is omitted. 1) The radiation protection against tile patient and the hospital visitor. 2) Radiation dose limit of the woman patient who is in the process of becoming pregnant. 3) Radiation dose limit of the person who is not regarded as madical madical exposure. 4) The control of the exposure of pregnant of women at work.

  • PDF

Recommended Methods for Surface Counting to Determine Sites of Red Cell Destruction - A Report by the Panel on Diagnostic Applications of Radioisotopes in Haematology of the International Committee for Standardization in Hematology

  • The Korea Society of Nuclear Medicine The Korea Society of Nuclear Medicine
    • The Korean Journal of Nuclear Medicine
    • /
    • v.8 no.1_2
    • /
    • pp.57-62
    • /
    • 1974
  • 이 논문(論文)은 1973년(年) ICSH주최로 열린 panel에서 적혈구파괴(赤血球破壞) 장소(場所)를 결정(決定)하기 위한 생체(生體) 체표계측법(醫表計測法)의 표준화(標準化)에 관(關)한 토론(討論) 결과(結果)를 초록(抄錄)한 것이다. 체표계측(體表計測)은 체외(體外)에서 계측기(計測器)를 이용(利用)하여 각(各) 장기(臟器)에서의 방사표지물질(放射標識物質)의 분포(分布) 및 시간경과(時間經過)에 따른 변화(變化)를 측정(測定)하는 것으로서 $^{51}Cr$를 사용(使用)하여 적혈구수명(赤血球壽命)을 측정(測定)할 때 간(肝), 비(脾), 심장(心臟)의 방사능(放射能)을 계측(計測)한다. 이 방법(方法)은 각(各) 장기(臟器)에서의 적혈구파괴(赤血球破壞)의 정도(程度)를 예측할 수 있다. 특(特)히 용혈성(溶血性) 빈혈환자(貧血患者)에서 비장적출(脾臟摘出) 여부를 결정(決定)하는데 도움이 된다. 이 panel에서는 주(主)로 오차(誤差)의 원인(原因)이 되는 여러가지 요인(要因)에 대(對)하여 토론(討論)하였으며 일반적으로 다음과 같은 것에 의견(意見)의 일치(一致)를 보았다. 즉(卽) 비장(脾臟)의 위치(位置)는 $^{99m}Tc$로 비주사(脾走査)를 실시하여 결정(決定)하는것이 좋고, $^{51}Cr$은 체중(體重) 1kg당 $1.5{\mu}Ci$를 사용하여, 계측기(計測器)는 NaI crystal(직경이 5cm이상, 두께가 3.75cm이상)의 scintillation doctor를 사용하고, 계측(計測)은 $^{51}Cr$로 표지(標識)된 적혈구(赤血球) 주입후(注入後) 15분(分) 이후(以後)에 하고 다음날 계측(計測)한 후(後) 2주(週) 동안에 적어도 6번 계측(計測)한다. Data 처리는 excess count법(法)과 비(脾)와 간(肝)의 비(比)로서하는 것이 좋다.定値)에 차이(差異)가 있어 그 결과(結果)의 해석(解釋) 및 비교(比較) 검토(檢討)에 적지않은 난점(難點)이 생겨 표준화(標準化)된 공통적(共通的)인 방법(方法)의 사용(使用)이 중요(重要)하다는 사실(事實)이 인식(認識)되게 되었다. 1966년(年) 호주(濠洲)의 Sydney에서 개최(開催)되었든 제11차(第11次) 국제혈액학회(國際血學會)때 열린 제4차(第4次) International Committee for Standardization in Haematology(ICSH)에서 Diagnostic Applications of Radioisotopes in Haematology에 관(關)한 expert panel을 갖을것을 의결(議決)하여 다음과 같은 12명(名)의 위원(委員)이 결정(決定)되었으며 위원회(委員會)의 의장(議長)에 Dr. Szur, 총무(總務)에 Dr. Glass가 각각(各各) 선임(選任)되었다. 그간(間) 1967년(年) 영경(英京) London에서 첫 회합(會合)이 있은후(後) New York, Vienna(IAEA후원(後援)) Brthesda(NIH후원(後援))에서 전문위원회(專門委員會)를 갖고 적혈구수명측정법(赤血球壽命測定法)에 관(關)한 의견(意見)의 일치(一致)를 보았다. ICSH와 국제혈액학회(國際血學會)에서는 이번에 결정(決定)된 적혈구수명측정법(赤血球壽命測定法)을 널리 소개(紹介)하며, 측정법(測定法)과 얻어진 결과(結果)의 해석(解釋)에 표준화(標準化)를 기(期)할 목적(目的)으로 이에 연관성(聯關性)있는 전문지(專門誌)에 게재(揭載)할 것을 요청(要請) 받었기에 이에 전문(全文)을 소개(紹介)하는 바이다. 이들은 방사성(放射性) chromium 법(法)의 모든 세부적(細部的)인 면(面)을 표준화(標準化)하고 있으며 그간(間) 가장 논란(論難)의 대상(對象)이 되었던, $^{51}Cr$-표지방법(標識方法)에 있어서의 세가지 변법(變法),

  • PDF

Payment Refusal against Discrepancy in Transport Document under L/C Transaction (신용장거래에서 운송서류 불일치에 대한 지급거절)

  • Lee, Jung-Sun
    • Korea Trade Review
    • /
    • v.42 no.2
    • /
    • pp.205-225
    • /
    • 2017
  • The study attempts to verify the case related to the notice of payment refusal by issuing bank regarding discrepancy in transport document under L/C(Letter of Credit) transaction. Considering the high portion of trade between Korea and China, Korean companies and banks in L/C transaction should be careful about many unpredictable situations. The case of this study is that Chinese seller(beneficiary) initiated a civil suit against Industrial Bank of Korea to Chinese court and Chinese courts in the first and second trials judged that the notice of payment refusal by Industrial bank of Korea doesn't satisfy Article 16, (c) (ii) (iii) in UCP 600. However, Industrial Bank of Korea implements the judgement even though the judgement is highly biased to Chinese seller. Considering the judgement by Chinese courts, the study suggests some countermeasures to Korean companies and banks which opened L/C. First, the issuing bank should describe the contents of discrepancy specifically based on Article 16, (c) in UCP 600. Second, it is necessary to insert a clause regarding governing law in the L/C contract like sales contract. Third, considering the biased judgement by Chinese court and difficulty in execution of foreign judgement in China, it is recommended to using arbitration as a method of dispute resolution such as ICLOCA and DOCDEX Rules which are international system operated by international instruments because it has legal effects to parties in L/C contracts if the issuing bank inserts arbitration clause in L/C.

  • PDF

Development of Analytical Method for Colistin in Fish and Shrimp using Liquid Chromatography Mass Spectrometry (LC-MS/MS를 이용한 수산물 중 콜리스틴 분석법 개발)

  • Shin, Dasom;Kang, Hui-Seung;Lee, Soo-Bin;Cho, Yoon-Jae;Cheon, So-Young;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.5
    • /
    • pp.319-326
    • /
    • 2016
  • Colistin is a last resort antimicrobial agent against multi-drug resistant Gram-negative bacteria. This study was conducted to develop an analytical method to determine colistin in fish and shrimp. The analytes were confirmed and quantified via liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the positive ion mode using multiple reaction monitoring (MRM). The sample was extracted with acidified 5% methanol (containing 0.5% formic acid). Then, solid phase extraction (SPE) was used for cleanup. Matrix-matched calibration curves were linear over the calibration ranges (0.05-1.2 mg/kg) for all the analytes into blank sample with $r^2$ > 0.99. All the values fulfilled the criteria requested by the Codex guidelines. Average recoveries ranged from 85.9% to 107.9%. The repeatability of measurements, expressed as the coefficient of variation (CV, %), was less than 15%. The limit of detection (LOD) was 0.02 mg/kg, and the limit of quantitation (LOQ) was 0.05 mg/kg. This improved method showed higher accuracy and acceptable sensitivity to meet the CAC guideline requirements and is applicable for the analysis of residual colistin (A+B) in fish and shrimp.

Proposal on the Creation of a New Space Organization for the Moon and Celestial Bodies' Exploitation (달과 천체 개발을 위한 새로운 우주기구의 창설에 관한 제안)

  • Kim, Doo-Hwan
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.29 no.1
    • /
    • pp.161-198
    • /
    • 2014
  • The idea of creating an International Space Exploitation Agency (tentative title: hereinafter referred to ISEA) is only my academic and theoretical opinion. It is necessary for us to establish ISEA as an international organization for the efficient and rapid exploitation of natural resources in the moon and other celestial bodies. The creation of ISEA as a new international organization is based on the Article 11, 5 and Article 18 of the 1979 Moon Agreement. In order to create it as a preliminary procedure, it needs to make the Draft for the Convention on the Establishment an ISEA among the space-faring countries. The main contents of this paper is composed of (1) introduction, (2) joint exploitation of the natural resources (Heliumn-3, etc.) in the moon and ISEA, (3) activities for the exploitation of moon and other celestial bodies by the space-faring powers, (4) legal problems and Solution for the exploitation and mining rights of the natural resources in the moon, mars and celestial bodies, (5) procedure of creating an ISEA, (6) the principal points that need to be included in the draft for the ISEA convention, (7) conclusion. The creation of an ISEA would lead to a strengthening of the cooperation among the States deemed essential by the global community towards joint undertakings in space and would act as a catalyst for the efforts on the exploitation of the natural resources moon, mars, Venus, Mercury and other celestial bodies and allow resources, technology, manpower and finances to be centrally managed in an independent fashion to the benefit of the space-faring countries. It is desirable and necessary for us to create ISEA in order to promote cooperation in the field of space policy, law, science technology and industry etc. among the space-faring countries. The creation of the ISEA will be promoted the international cooperation among the space-faring countries in exploration and exploitations of the natural resources in the moon, Mars, Venus, Mercury and other celestial bodies. Finally, it should be noted that the political drive will be necessary not only to set up the organization ISEA, but also study a subsequent measures. It is also necessary for us to create the ISEA in order to develop the space industry, to strengthen friendly relations and to promote research cooperation among the space-faring countries based on the new ideology and creative ideas. If the heads (president or prime minister) of the space super-powers including the UNCOPUOS will be agreed to establish ISEA at a summit conference, 1 believe that it is possible to establish an ISEA in the near future.

Improvement of an Simultaneous Determination for Clenbuterol and Ractopamine in Livestock Products using LC-MS/MS (LC-MS/MS를 이용한 축산물 중 clenbuterol과 ractopamine의 동시 분석법 개선)

  • Cho, Yoon-Jae;Chae, Young-Sik;Kim, Jae-Young;Kim, Hyung-Soo;Kang, Ilhyun;Do, Jung-Ah;Oh, Jae-Ho;Kwon, Kisung;Chang, Moon-Ik
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.25-33
    • /
    • 2013
  • Clenbuterol and ractopamine, which are ${\beta}$-agonists, have been misused as a growth promoting agent in meat producing animals. Clenbuterol was banned for veterinary drug in Korea because of its problems regarding safety. Due to their adverse effects, such as cardiovascular and central nervous diseases on human health proper control and monitoring should be conducted. The existing analytical method of clenbuterol and ractopamine in the Food code was improved through our present study. The bovine muscle samples were subjected to enzymatic hydrolysis, extracted with ethyl acetate and defatted by hexane-methanol partitioning. A molecular imprinted polymer (MIP) solid phase extraction cartridge was used for clean-up and LC-MS/MS was operated in positive multiple reaction monitoring (MRM). Clenbuterol-$d_9$ and ractopamine-$d_3$ were used as an internal standard. The renewed method was validated according to the CODEX guideline. The limits of quantitation for clenbuterol and ractopamine were 0.2 and 0.5 ${\mu}g/kg$, respectively. The mean recoveries ranged in 104.2-113.5% for clenbuterol and in 107.6-118.1% for ractopamine. The improved method was able to save both time and expenses.

The New International Guidelines for Cardiopulmonary Resuscitation (심폐소생술의 최신지침 소개)

  • 우건화
    • Journal of Chest Surgery
    • /
    • v.36 no.6
    • /
    • pp.451-455
    • /
    • 2003
  • In August 2000, the American Heart Association and the European Resuscitation Council published the conclusions of tile International Guidelines 2000 Conference on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care which contains both the new recommendations and an in-depth review. The most important changes in the recommendations according to the authors are discontinuation of the pulse-check for lay people, 500 ml instead of 800∼1,200 ml tidal volume during bag-valve-mask ventilation (FiO2 > 0.4) of a patient with an unprotected airway, unifying correct endotracheal intubation size as 8.0 mm, vasopressin (40 units) and epinephrine (1 mg) as comparable drugs to treat patients with ventricular fibrillation, early prehospital survey and intravenous lysis for patients who have suffered coronary artery syndrome and stroke.

Analysis of the Effects of Traffic Signal Operation Methods (대전시 신호운영체계 개편에 따른 효과분석)

  • Lee, Jung-Beom;Lee, Beom-Kyu
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.4
    • /
    • pp.60-67
    • /
    • 2010
  • Delay reduction of vehicles at the intersection is highly dependent on the signal operation method. Most previous traffic operations have focused on minimizing delay by adjust traffic offset. However, these methods have limitation in solving traffic problem if the volume reaches or exceeds the capacity. In this paper, it was analyzed that the effectiveness of various signal operation methods such as left-turn prohibition, and using protected mixed with permitted left turn using the traffic data from Daejeon city. In case of the left-turn prohibition of a intersection, the control delay reduced from 54.2 seconds to 22.7 seconds and especially, the delay of the southbound was drastically reduced. In addition, the delay was highly reduced from 27.0 seconds to 12.1 seconds when the operation system was changed to use protected mixed with permitted left turn.

Guidelines of IRPA/ICNIRP for Non-ionizing Radiation (비이온화방사선에 대한 IRPA/ICNIRP의 제반지침)

  • Lee, Soo-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.3
    • /
    • pp.143-154
    • /
    • 1995
  • In recent years, the development of new technologies using static magnetic fields has increased the possibility of human exposure to these fields and raised some concern as to their possible health effects. In several countries, governmental or other competent authorities have issued exposure limits that are mainly intended for specific uses, i.e., magnetic resonance imaging (MRI) and particle accelerators for high-energy Physics. Since applications of magnetic fields in industry and medicine are likely to grow in the future, thus increasing the possibility of occupational and general public exposure, and since the number of people with ferromagnetic implants and implanted electronic devices that can be affected by the fields is growing, there is a need for international guidelines. In the present papers, guidelines on limits of exposure to static magnetic fields are selected and discussed in order to review the guidelines of the International Non-ionizing Radiation Committee of the International Radiation Protection Association (IRPA/INIRC) for non-ionizing radiation(NIR)

  • PDF

Assessment of Thyroid Dose Evaluation Method by Monitoring of I-131 Concentration in Air (공기중 I-131 농도 감시에 의한 갑상선 피폭 평가법의 적용성)

  • Lee, Jong-Il;Seo, Kyung-Won
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.1
    • /
    • pp.69-80
    • /
    • 1994
  • The TCMI(Three-Compartment Model for iodine) computer code has been developed, which is based on the three-compartment model and the respiratory model recommended in ICRP publication 54. This code is able to evaluate the thyroid burden, dose equivalent, committed dose equivalent and urinary excretion rate as time-dependent functions from the input data: working time and the radioiodine concentration in air. Using the TCMI code, the time-dependent thyroid burdens, the thyroid doses and the urinary excretion rates were calculated for three specific exposure patterns : acute, chronic and periodic. Applicability as an internal dose evaluation method has been assessed by comparing the results with some operational experiences. Simple equations and tables are provided to be used in the evaluation of the thyroid burden and the resulting doses for given I-131 concentration in air and the working time.

  • PDF