• Title/Summary/Keyword: 구조진동제어

Search Result 711, Processing Time 0.037 seconds

Anti-Fouling System for Oscillating Water Column in Buoy (진동 수주형 브이의 Anti Fouling system)

  • Oh, Jin-Seok;Jo, Kwan-Jun
    • Journal of Navigation and Port Research
    • /
    • v.34 no.6
    • /
    • pp.441-445
    • /
    • 2010
  • The ouput power of wave energy system in buoy is determined according to the inner diameter of oscillating water column and flow resistance. The increase of adhered shellfish inside the water column leads to decrease the inner diameter of wave energy converter. Influx loss of seawater reduces the efficiency of output power in the wave generation system. In this paper, the test result of AFS characteristic is described for preventing the deposition with shellfish and etc. The current of anode is controlled by buck converter, and the control algorithm developed for AFS in buoy. The experimental results is shown excellent preventing capapbility of AFS in buoy.

A Vibration Control of Multi-layer Structure by LQ Type $H_{\infty}$ Control Theory (LQ 형 $H_{\infty}$ 제어기법에 의한 다층 구조물의 진동제어)

  • Yang, J.H.;Jeong, H.J.;Kim, C.H.;Byun, J.H.;Sim, S.H.
    • Journal of Power System Engineering
    • /
    • v.2 no.2
    • /
    • pp.41-46
    • /
    • 1998
  • This paper presents the vibration control for the two degree-of-freedom which is a reduced model of multi-layer structure. This reduced model is designed for the first and second order resonance in the low frequency domain where the disturbance such as the earth quake has the large energy. And a designed controller using the LQ type $H_{\infty}$ control theory shows the good performance for the impulse disturbance through the experimental results and the simulation results respectively.

  • PDF

A Design of Robust Vibration Control System for a Four-story Shear Structure (4층 층상 구조물에 대한 강인한 진동 제어 시스템 설계)

  • Yang, J.H.;Jeong, H.H.;Jeong, H.J.
    • Journal of Power System Engineering
    • /
    • v.7 no.1
    • /
    • pp.60-67
    • /
    • 2003
  • This paper introduces basic study how to restrain the vibration of a four story shear structure. We have modeled a four story shear structure mathematically and have identified each parameters by experiment. We have gotten a reduced nominal model through modal analyzing method and the $H_{\infty}$ control theory is used in the control system design to get the robust controller. It's shown that the desirable performances is confirmed through the mathematical simulation. And a designed controller applying the $H_{\infty}$ control theory shows the good performance for the impulse disturbance through the simulation results. That is, the robustness of this control system is confirmed for the ability of disturbance rejection and modeling error.

  • PDF

The Vibration Control of a Opened Box Structure By a Neuro-Controller (신경망 제어기를 이용한 열린 박스 구조물의 진동 제어)

  • 신윤덕;장승익;기창두
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.983-987
    • /
    • 2003
  • Vibration causes noise and makes structure unstable. Especially, due to the effort of lightening, deformation of flexible structure is increased in its shape. Just a little disturbance causes vibration and low damping ratio causes residual vibration lasts long time. In this paper, by using a neuro-controller, which is one of the algorithm of adaptive control. we performed adaptive control of flexible cantilever plate and opened box structure with piezoelectric materials. The proposed adaptive vibration control algorithm, a neuro-controller, is proved in its effectiveness by applying to a opened box structure. The neuro-controller was implemented with DSP, and the real-time adaptive vibration control experiment results confirm that neuro-controller is reliable.

  • PDF

FFT and AR Coefficient Analysis of Vibration Signal in Mold Transformer (몰드변압기 진동신호의 FFT 및 시계열 계수 분석)

  • 정용기;정종욱;김재철;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.136-145
    • /
    • 1998
  • This paper describes the FFT and coefficient analysis of vibration signals for preventive diagnosis of a mold transformer at normal and abnormal state. Varying applied voltage, loading current and temperature as control variables for he experiment, measurement variables such as magnitude of vibration signals, frequency spectrum and time series coefficient were analyzed. The vibration signals by variation of control variables were measured by acceleration sensor adhered on the surface of winding and core, and measurement variables were calculated using dat acquisition system. After analyzing the normal state, the structural distortion was also simulated. The vibration signals at abnormal state were measured by the same control variables variation as the normal state. As a result, vibration signals between normal and abnormal state could be distinguished by comparison of the perpendicular and horizontal vibration signal.

  • PDF

Application of Seismic Isolation and Vibration Control in Korea (우리나라의 면진 및 진동제어)

  • Lee, Dong-Guen;Kim, Tae-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.67-77
    • /
    • 2006
  • Seismic activity of Korea is not so high as that of Japan or California and most of the structures were designed without considering the influence of earthquakes until the first seismic design code was enforced in 1988. Therefore, it was very hard to find seismically isolated structures in Korea until 1980's. Korean engineers assumed that the seismic isolation or vibration control would be useful only in a high seismicity region while such technologies can be quite useful in a low seismicity region for the efficient reduction of earthquake damages. Recently, Korean engineers began to have interest in the seismic isolation or vibration control and applied it to some important structures such as LNG storage tanks, many bridges and several buildings. However, design codes are not defining such useful advanced technologies for the design of building structures and several projects employing seismic isolation or vibration control in the design of structures had difficulties in obtaining construction permit from the local government. Therefore, it is an urgent requirement to introduce these advanced technologies in the seismic design code.

Modal Analysis of Treadmill Machine (트레드밀 기구의 진동해석)

  • Lee Jong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.539-544
    • /
    • 2006
  • This study is to apply a modal analysis for a frame and roller of a treadmaill machine. A finite element model was developed to compute natural frequencies of a frame and a roller. This analysis were performed under several different conditions such as weight, boundary, and maxium stress/strain conditions.

  • PDF

Modal Analysis of Treadmil Frame (트레드밀 프레임의 진동해석)

  • Lee, Jong-Sun;Lee, Jin-Sung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.05a
    • /
    • pp.174-176
    • /
    • 2006
  • 본 논문에서는 모터와 롤러에 의해 발생된 진동이 프레임에 전달되고 또한 롤러가 회전하면서 프레임에 진동을 전달하여 공진을 일으킬수 있으므로 프레임과 롤러의 고유진동수를 해석함으로서 진동발생 요인인 모터의 회전 주파수를 제어하고 진동에 대한 구조적 안전성을 평가하였다.

  • PDF

Modal Analysis of Automotive Body Model using Mode Synthesis Method (모드합성법을 사용한 차체모델의 모달해석)

  • 장경진;지태한;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.34-39
    • /
    • 1995
  • 최근 승용차의 급격한 수요증가와 더불어 차량의 승차감 개선에 많은 관심이 집중되면서, 저진동 저소음 차량에 대한 연구가 활발히 이루어지고 있다. 이러한 연구의 일부로서, 수치해석법 및 진동실험에 의하여 복잡한 전체 구조물을 해석할 경우, 계산기의 기억용량, 계산시간, 비용이 많이 들게 되고, 한번 해석을 행한 구조물을 부분적으로 변경할지라도 전체의 계산을 다시 수행해야만 한다. 그래서, 복잡한 전체 구조물을 몇 개의 부분구조물로 나누어, 분계의 특성에 맞게 각기 수치해석법이나 모달실험을 적용한 후, 다시 합성하는 방법이 제시되었는데, 이것이 부분구조합성법이다. 이 방법을 사용하면, 유한요소 모델링이 쉬운 분계와 실험이 쉬운 분계를 서로 구분하여 각기 해석한 후 합성함으로써, 각 분계의 특성에 맞는 효율적인 해석을 수행할 수가 있다. 지금까지의 연구를 살펴보면, 유한요소해석에 의한 모드합성법에서는 Hurty가 구속모드법을 제안한 이래, 불구속모드법, 주종계법 등 많은 연구가 있었으나, 실험모달해석을 병행할 경우에는 결합부에서의 회전자유도의 처리문제, 특성 행렬의 동정문제, 많은 절점으로부터 데이타를 얻어야 하는 등의 어려움이 있었다. 이러한 문제를 개선시켜서 Hermanski등은 회전자유도가 보간된 모드합성법(interpolated mode synthesis, IMS)을 연구하여, 적은 실험데이타만을 사용하면서 단순지지 보에 적용함으로써 타당성을 입증하였다. 한편, 차체는 복잡한 부분구조물들로 이루어져 있으므로, 본 연구에서는 유한요소모델링의 용이함, 실험의 간편성, 계산의 효율성등을 추구하며, 실험과 유한요소해석을 병행한 부분구조합성법을 차량의 BIW(body in white)에 적용하는 방법을 연구하게 되었다. 그 기본연구로서 실험과 유한요소해석을 병행하여 회전자유도를 보간하는 방법을 먼저 단순한 판구조물에 적용을 하고, 나아가 실제 BIW를 축소하여 자체 제작한 모형차에 적용시켜 보았다.물은 분계 A(16개의 사각요소)와 분계 B(8개의 사각요소)로 이루어져 있으며 두개의 스프링으로 결합되어 있다. 설계변수는 강성에 국한하였으며 결합부의 결합형태는 탄성결합과 강결합으로 하였다. 감도해석과 축소임피던스 합성법에 의해 구해진 고유진동수와 FRF를 상용 유한 요소 해석 패키지인 MSC/NASTRAN을 통하여 검증하여 이 연구의 타당성을 검토하였다.인풋기어에서의 회전수 변동을 측정하고, 이 실험 데이타를 기초로 하여 엔진 토크 및 변속기에서의 드래그 토크를 계산하여 엔진-변속기 인풋기어의 반한정계 2자유도 진동모델과 비틀림 특성을 가진 클러치 디스크의 프리댐퍼 영역에 대해 시뮬레이션을 수행하여 클러치 비틀림 기구의 설계인자인 비틀림 강성, 히스테리시스 토크에 따른 비틀림 진동 저감 효과를 연구하고자 한다.성을 확인하였다. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field and the maximum relaxivity value. Th

  • PDF

Study of Integrated Optimal Design of Smart Top-Story Isolation and Building Structures in Regions of Low-to-Moderate Seismicity (중약진지역 구조물과 스마트 최상층 면진시스템의 통합최적설계에 대한 연구)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.13-20
    • /
    • 2013
  • In order to reduce seismic responses of a structure, additional dampers and vibration control devices are generally considered. Usually, control performance of additional devices are investigated for optimal design without variation of characteristics of a structure. In this study, multi-objective integrated optimization of structure-smart control device is conducted and possibility of reduction of structural resources of a building structure with smart top-story isolation system has been investigated. To this end, 20-story example building structure was selected and an MR damper and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes generated based on design spectrum of low-to-moderate seismicity regions are used for structural analyses. Based on numerical simulation results, it has been shown that a smart top-story isolation system can effectively reduce both structural responses and isolation story drifts of the building structure in low-to-moderate seismicity regions. The integrated optimal design method proposed in this study can provide various optimal designs that presents good control performance by appropriately reducing the amount of structural material and damping device.