1 |
Park, K. S. and Koh, H. M., "Preference based optimum design of an integrated structural control system using genetic algorithms", Advances in Engineering Software, Vol. 35, No. 2, 2004, pp.85-94.
DOI
ScienceOn
|
2 |
Park, K. S., Koh, H. M. and Hahm, D. G., "Integrated optimum design of visco-elastically damped structural systems", Engineering Structures, Vol. 26, 2004, pp.581-591.
DOI
ScienceOn
|
3 |
Park, K. S., Koh, H. M. and Ok, S. Y., "Integrated optimal design of hybrid structural control system using multi-stage goal programming technique", Journal of the Earthquake Engineering Society of Korea, Vol. 7, No. 5, 2003, pp.93-102 (in Korean).
과학기술학회마을
DOI
ScienceOn
|
4 |
Sues, R. H., Mau, S. T. and Wen, Y. K., "System identifcation of degrading hysteretic restoring forces", Journal of Engineering Mechanics, ASCE, Vol. 114, No. 5, 1988, pp.833-846.
DOI
ScienceOn
|
5 |
Warburton, G. B., "Optimum absorber parameters for various combinations of response and excitation parameters", Earthquake Engrg. and Struct. Dyn., Vol. 10, 1982, pp.381-401.
DOI
|
6 |
Bani-Hani, K. A. and Sheban, M. A., "Semi-active neuro-control for base-isolation system using magnetorheological (MR) dampers", Earthquake Engng Struct. Dyn., Vol. 35, 2006, pp.1119-1144.
DOI
ScienceOn
|
7 |
Chun, Y. S. and Hur, M. W., "Seismic isolation effects according to set up the isolation period in the medium and low-rise frame building", Journal of the Korean Institute for Structural Maintenance Inspection, Vol. 14, No. 6, 2010, pp.93-99 (in Korean).
|
8 |
Deb, K., Pratap, A., Agrawal, S. and Meyarivan, T., "A fast and elitist multiobjective genetic algorithm: NSGA-II", Evolutionary Computation, IEEE Transactions, Vol. 6, No. 2, 2002, pp.182-197.
DOI
ScienceOn
|
9 |
Jun, D. H., "Seismic response of R/C structures subjected to simulated ground motions compatible with design spectrum", Structural Design of Tall and Special Buildings, Vol. 22, No. 1, 2013, pp.74-91.
DOI
ScienceOn
|
10 |
Kang, J. W., Kim, T. H. and Kim, H. S., "Performance evaluation of vibration control of a smart top-story isolation system", Journal of the Korean Association for Spacial Structures, Vol. 10, No. 3, 2010, pp.49-56 (in Korean).
과학기술학회마을
|
11 |
Ok, S. Y., Park, K. S., Song, J. H. and Koh, H. M., "Multi-objective integrated optimal design of hybrid structure-damper system satisfying target reliability", Journal of the Earthquake Engineering Society of Korea, Vol. 12, No. 2, 2008, pp.9-22 (in Korean).
과학기술학회마을
DOI
ScienceOn
|
12 |
Kim, H. S. and Kang, J. W., "Investigation of adaptability of smart top-story isolation system to structures in regions of low-to-moderate seismicity", Journal of the Korean Association for Spacial Structures, Vol. 12, No. 4, 2012, pp.71-80 (in Korean).
과학기술학회마을
DOI
ScienceOn
|
13 |
Koo, J. H., Setareh, M. and Murray, T. M., "In search of suitable control methods for semi-active tuned vibration absorbers", Journal of Vibration and Control, Vol. 10, 2004, pp.163-174.
DOI