• Title/Summary/Keyword: 구조보강

Search Result 2,829, Processing Time 0.025 seconds

A Study on Watertightness Improvement of Hybrid Method Using Polyvinyl Acetate(PVAc) (폴리비닐아세테이트(PVAc)를 이용한 복합공법의 수밀성능 향상에 관한 연구)

  • Ryou, Jae Suk;Song, Il Hyun;Lee, Yong Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.18-24
    • /
    • 2012
  • In this study, hybrid method using polyvinyl acetate (PVAc) which has a strong adhesion and flexibility in which acrylic copolymer chemical-reaction reacts with cement, and is eco-friendly, is to improve the watertightness. The hybrid method is applied applied primarily waterproof stuff comprising silicate system and secondary mortar mixed with PVAc on the concrete surface. And then, in order to evaluate the performance, the properties of bond strength and amount of water absorption were measured. Based on the above experiments, mock-up specimens for field application were fabricated, and then the properties were evaluated as laboratory experiments. As the results, specimens cast from hybrid method using PVAc showed the best results on watertightness and bond strength. And also, with respect to experiment of mock-up specimens, the properties were in agreement with laboratory results. Especially, it could know that PVAc has strengthening effect from the results of the compressive strength. Due to outstanding results of carbonation depth and resistance to chloride ion penetration, it may be applied in weak areas such as underground and marine structures.

Experimental Study on Engineering Performance Evaluation and Field Performance of Environmentally Friendly Functional Concrete (친환경 기능성 콘크리트의 공학적 성능평가 및 현장적용성능에 관한 실험적 연구)

  • Lee, Byung-Jae;Park, Seong-Bum;Kim, Yun-Yong;Jang, Young-Il
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.2
    • /
    • pp.165-172
    • /
    • 2012
  • In this study, the physical, mechanical, structural, and environmental performances based on field measured data were evaluated to check the suitability of concrete for ecological preservation and cultivation of a hydrophilic environment. More specifically, the study is focused on developing an environmentally friendly functional concrete with river ecology restoration and natural river early formation capabilities. The mechanical performance evaluation results showed that the increase in mix rate of the PVA (Poly Vinyl Alcohol) reinforcement fibers and silica fume caused an increase in the strength. The optimal mix rate was found to be 0.05 volume % PVA fiber and approximately 10% silica fume. The frost resistance evaluation showed that superior performance was gained when 0.05 volume % PVA fiber and 15% silica fume was mixed simultaneously. In the structural performance evaluation, the bending strength was improved by 47.7% compared to plain concrete when mixed with 0.05 volume % PVA fiber. The flexural toughness also saw significant improvement. The environmental monitoring of field performance showed that grasses germinated most rapidly, but the growth of red poppies, a plant that germinates in the spring, was most active with passing of time. Coverage measurements in all of the monitoring locations found favorable coverage of over 95% after 12 weeks. The study results showed that the environmentally friendly functional concrete had outstanding environmental performance.

A Study on Stability Evaluation of the Nail-Anchor Mixed Support System

  • Kim, Hong-Taek;Cho, Yong-Kwon;Yoo, Han-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.3
    • /
    • pp.41-70
    • /
    • 1999
  • The benefits of utilizing internal reinforced members, such as soil nails and ground anchors, in maintaining stable excavations and slopes have been known among geotechnical engineers to be very effective. Occasionally, however, both soil nails and ground anchors are simultaneously used in one excavation site. In the present study, a method of limit equilibrium stability analysis of the excavation zone reinforced with the vertically or horizontally mixed nail-anchor system is proposed to evaluate the global safety factor with respect to a sliding failure. The postulated failure wedges are determined based on the results of the $FLAC^{2D}\; 및\; FLAC^{3D}$ program analyses. This study also deals with a determination of the required thickness of the shotcrete facing. An excessive facing thickness may be required due to both the stress concentration and the relative displacement at the interface zone between the soil nailing system and the ground anchor system. A simple finite element method of analysis is presented to estimate the corresponding relative displacement at the interface zone between two different support systems. As an efficient resolution to reduce the facing thickness, the modified bearing plate system is also proposed. Finally with various analysis related to the effects of design parameters, the predicted displacements are compared with the results of the $FLAC^{2D}$ program analyses.

  • PDF

A study on Monitoring the Inner Structure of Dam Body Using High Resolution Seismic Reflection Method (고분해능 탄성파 반사법을 이용한 댐체 내부구조 모니터링 연구)

  • Kim, Jung-Yul;Kim, Hyoung-Soo;Oh, Seok-Hoon;Kim, Yoo-Sung
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.1
    • /
    • pp.1-6
    • /
    • 2005
  • Defects of dam body which can be induced in seepage or leakage procedure can directly affect dam safety. Therefore, a proper inspection method should be carried out in the first place to find out their positions and sizes. After that, some reinforcement works such as grouting and the corresponding assessment could be taken in a proper way. The dam(center core type earth dam) issued in this study has been in need for intensive diagnosis and reinforcement work, because a lot of slumps similar to cracks, seepage and some boggy area have been observed on the downstream slope. High resolution seismic reflection method was performed on the crest profile twice before and after grouting work(Aug. 2001 and Nov. 2004) aimed at the dam inspection and the assessment of grouting efficiency as well. To enhance the data resolution, P-beam energy radiation technique which can reduce the surface waves and hence to reinforce the reflection events was used. Strong reflection events were recognized in the stack section before grouting work, It seems that the events would be caused by e.g. horizontal cracks with a considerable aperture. Meanwhile such strong reflection events were not observed in the section after grouting. That is, the grouting work was dear able to reinforce the defects of dam body. Hence, the section showed an well arranged picture of dam inner structure. In this sense, seismic reflection method will be a desirable technique for dam inspection and for monitoring dam inner structure as well.

  • PDF

Half-metallicity and Magnetism of Co2ZrSi/ZnTe(001) Interface: A First-principles Study (Co2ZrSi/ZnTe(001)계면의 자성과 반쪽금속성에 대한 제일원리 연구)

  • Jin, Y.J.;Lee, J.I.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.4
    • /
    • pp.147-151
    • /
    • 2007
  • We have investigated the half-metallicity and magnetism for the Heusler ferromagnet $Co_2$ZrSi interfaced with semiconductor ZnTe along the (001) plane by using the full-potential linearized augmented plane wave (FLAPW) method. We considered low types of possible interfaces: ZrSi/Zn, ZrSi/Te, Co/Zn, and Co/Te, respectively. From the calculated density of states, it was found that the half-metallicity was lost at all the interfaces, however for the Co/Te system the value of minority spin density of states was close to zero at the Fermi level. These facts are due to the interface states, appeared in the minority spin gap in bulk $Co_2$ZrSi, caused by the changes of the coordination and symmetry and the hybridizations between the interface atoms. At the Co/Te interface, the magnetic moments of Co atoms are 0.68 and $0.78{\mu}_B$ for the "bridge" and "antibridge" sites, respectively, which are much reduced with respect to that ($1.15{\mu}_B$) of the bulk $Co_2$ZrSi. In the case of Co/Zn, Co atoms at the "bridge" and "antibridge" sites have magnetic moments of 1.16 and $0.93{\mu}_B$, respectively, which are almost same or slightly decreased compared to that of the bulk $Co_2$ZrSi. On the other hand, for the ZrSi/Zn and ZrSi/Te systems, the magnetic moments of Co atoms at the sub-interface layers are in the range of $1.13{\sim}1.30\;{\mu}_B$, which are almost same or slightly increased than that of the bulk $Co_2$ZrSi.

A Study on the Analysis of Current Situation of Safety Inspections cost in Apartment houses (공동주택 안전점검대가 현황분석에 관한 연구)

  • Go, Seong-Seok;Song, Do-Heom;Yun, Yeong-Chae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.2
    • /
    • pp.62-70
    • /
    • 2014
  • An apartment house, a private facility, is a house built for many persons to live independently in a building. An apartment house is a building where life damage can happen most in case of a safety accident due to insufficient inspections. However, formal inspections are being realized due to awareness shortage of managing bodies about safety inspection and low-price order-receiving of diagnosing enterprises via the lowest bidding method. This is because it is judged that remarkable costs are inputted in repairs and reinforcement such as maintenance of a structure and that there is a large possibility of human damage in case of a safety accident in a structure. So, this paper aims to derive the points to improve in the current criterion to execute an efficient detailed inspection. As its method, the design price and execution price situation of 66 buildings inspected in detail for recent 3 years for the class 2 facilities in Gwangju Metropolitan City and Jeonranam-do are examined and analyzed. The state2 object buildings to inspect are selected through this. And this paper aims to present the points to improve through the analysis of current problems by evaluating the detailed inspection report and the detailed inspection execution price calculation criterion for the selected 10 apartment houses.

Study on the Testing Method for Setting Time of Set Accelerating Agent Using Shotcrete by Gilmour Needles (길모어침에 의한 숏크리트용 급결제의 품질시험방법에 대한 고찰)

  • Kim, Chun Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.195-200
    • /
    • 2011
  • KS F 2782 (for shotcrete accelerators) standard cross-section of tunnel construction or repair is a reinforcement used in the field of shotcrete accelerators as a criterion in assessing shotcrete performance. Thus, KS F 2782 by standard accelerator will determine the nature of the product of concrete accelerators that will be used to record variations in the product roles, through determination of the quality of the experimental method to identify only the quality of the many variables that exist. This evaluation standard has so far distinguished accelerator products in indoor experiments that do not meet quality standards but were mostly for an on-site accelerator mixed with the shotcrete after being quite satisfied with the level of quality in a certain number of products. This observation is derived from the results of an indoor experiment considered to verify whether the site is suitable for indoor experiments, and whether its actual location in the city is relevant to the accelerator quality, to find a way to test if it fits. This study centers on the material conditions of the shotcrete accelerator and a variety of experimental results, and used the Gilmore needle to compare the compressive strength and KS F 2782 specification of the accelerator as a means to ensure product quality conformity analysis and for further research experiments. In conclusion, a portion of KS F 2782 standard that fixes the problems that can be resolved from the ground up as a whole is not a review for the domestic reality. As an indoor experiment to ensure uniformity in the field when applied in a sufficient correlation, complement must be in place.

The Property Evaluation of the Marine Concrete Structure Constructed in the Period of Japanese Occupancy (YoungDo Bridge) (일제시대 건설된 해양 콘크리트구조물의 물성 평가(영도대교))

  • Park, Dong-Cheon;Ahn, Jae-Cheol
    • Journal of Navigation and Port Research
    • /
    • v.37 no.2
    • /
    • pp.165-171
    • /
    • 2013
  • YoungDo bridge is the first suspension bridge in Busan which experienced several times repair and reinforcement after completion in 1934. The bridge is under demolition for extension and restoration work since 2011. The purpose of this research is to establish data base about modern concrete. The mix design of the concrete is like that cement : fine aggregate : coarse aggregate = 1 : 2 : 4 or 1 : 3 : 6 by the parts. The compressive strength is in the ranges from 50 to 55 MPa and the elastic modulus is in the ranges from 25 to 35 GPa. From the fact that the deviation is less than 10 %, considerably high quality control was conducted in those days. The carbonation depth is 5.92 cm at the bridge post and 14.3 cm at the machine room. That is why ocean environment keeps the high humidity. The diffusion coefficient of chloride ion through the pores in concrete is 1.052e-12 $m^2/s$ from the regression analysis using the experiment data. The water cement ration is estimated at approximately 35 % in case if the concrete using ordinary Portland cement.

Development of Bond Strength Model for FRP Plates Using Back-Propagation Algorithm (역전파 학습 알고리즘을 이용한 콘크리트와 부착된 FRP 판의 부착강도 모델 개발)

  • Park, Do-Kyong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.2
    • /
    • pp.133-144
    • /
    • 2006
  • In order to catch out such Bond Strength, the preceding researchers had ever examined the Bond Strength of FRP Plate through their experimentations by setting up of various fluent. However, since the experiment for research on such Bond Strength takes much of expenditure for equipment structure and time-consuming, also difficult to carry out, it is conducting limitedly. This Study purposes to develop the most suitable Artificial Neural Network Model by application of various Neural Network Model and Algorithm to the adhering experiment data of the preceding researchers. Output Layer of Artificial Neural Network Model, and Input Layer of Bond Strength were performed the learning by selection as the variable of the thickness, width, adhered length, the modulus of elasticity, tensile strength, and the compressive strength of concrete, tensile strength, width, respectively. The developed Artificial Neural Network Model has applied Back-Propagation, and its error was learnt to be converged within the range of 0.001. Besides, the process for generalization has dissolved the problem of Over-Fitting in the way of more generalized method by introduction of Bayesian Technique. The verification on the developed Model was executed by comparison with the resulted value of Bond Strength made by the other preceding researchers which was never been utilized to the learning as yet.

Study on Determination of Proper Pillar Width in Road Tunnel Design Stage (도로터널에서 적정한 필라폭 산정에 관한 연구)

  • Yang, Tae-Seon;Kim, Jae-Kyoung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.187-194
    • /
    • 2010
  • As the design of the pillar width (PW) of the parallel tunnels in downtown area, in which are located in plains zone with deep alluvium compared with mountain tunnels, is directly related with pre-compensation payment and costs of the underground area, it has to be planned as to keep minimum distance while securing the stability of the parallel tunnels. Although PW of downtown road tunnel in Korea is standardized as 1.5D(D: diameter of the tunnels), PW sometimes has to be reduced within 1.5D to adjust the tunnel lines to the city plan in the cases of the inlet and outlet of the tunnels. In this paper, the design and the analyses of optimum PW of the NATM type road tunnel in the downtown area are introduced. The relationship among the tunnel line planning and underground compensation fee, and ground characteristics are evaluated. In the determination of PW distance, the numerical analyses of underground road tunnels were performed, including the use of the strength decrease method and strength/stress ratio method. In the cases of inlet and outlet part of the tunnels where the stability of the pillars is poor due to contiguous construction of the parallel tunnels, the reinforcement methods are recommended for securing the stability. Numerical verification was performed for the reinforcement proposed.