• Title/Summary/Keyword: 구면

Search Result 473, Processing Time 0.024 seconds

Estimating Geometric Transformation of Planar Pattern in Spherical Panoramic Image (구면 파노라마 영상에서의 평면 패턴의 기하 변환 추정)

  • Kim, Bosung;Park, Jong-Seung
    • Journal of KIISE
    • /
    • v.42 no.10
    • /
    • pp.1185-1194
    • /
    • 2015
  • A spherical panoramic image does not conform to the pin-hole camera model, and, hence, it is not possible to utilize previous techniques consisting of plane-to-plane transformation. In this paper, we propose a new method to estimate the planar geometric transformation between the planar image and a spherical panoramic image. Our proposed method estimates the transformation parameters for latitude, longitude, rotation and scaling factors when the matching pairs between a spherical panoramic image and a planar image are given. A planar image is projected into a spherical panoramic image through two steps of nonlinear coordinate transformations, which makes it difficult to compute the geometric transformation. The advantage of using our method is that we can uncover each of the implicit factors as well as the overall transformation. The experiment results show that our proposed method can achieve estimation errors of around 1% and is not affected by deformation factors, such as the latitude and rotation.

A Study of a Correction Effect of Astigmatism using Spherical RGP Lens (근시성 난시안에서 구면 RGP 콘택트렌즈의 난시교정 효과)

  • Ju, Seok-Hui;Park, Hae-Jung;Shin, Chul-Gun;Shim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.85-89
    • /
    • 2003
  • A tear lens formed by between back surface of spherical rigid gas permeable(RGP) contact lens and front surface of cornea shows an excellent correction effect of astigmatism. To study an effects of tear lens power using spherical RGP lens and therefore to utilize them in clinical procedures, we analyze a change of the total astigmatism, the cornea astigmatism, and the residual astigmatism, we derive the following conclusion. 1. Almost all refractive astigmatism below than 2.00D present fully corrected. Thereby resulting good visual acuity. Refractive astigmatism higher than 2.50D show under-corrected and apparent decrease of visual acuity if it is higher than 3.00D. 2. Amount of corneal astigmatism below than 2.50D show acceptable under-corrected while higher than 3.000 present unacceptable visual acuity. 3. An estimated residual astigmatism is not revealed as it is : but it is reduced when it incorporate to refractive astigmatism.

  • PDF

Spherical Slepian Harmonic Expression of the Crustal Magnetic Vector and Its Gradient Components (구면 스레피안 함수로 표현된 지각 자기이상값과 구배 성분)

  • Kim, Hyung Rae
    • Economic and Environmental Geology
    • /
    • v.49 no.4
    • /
    • pp.269-280
    • /
    • 2016
  • I presented three vector crustal magnetic anomaly components and six gradients by using spherical Slepian functions over the cap area of $20^{\circ}$ of radius centered on the South Pole. The Swarm mission, launched by European Space Agency(ESA) in November of 2013, was planned to put three satellites into the low-Earth orbits, two in parallel in East-West direction and one in cross-over of the higher altitude. This orbit configuration will make the gradient measurements possible in North-South direction, vertical direction, as well as E-W direction. The gravity satellites, such as GRACE and GOCE, have already implemented their gradient measurements for recovering the accurate gravity of the Earth and its temporal variation due to mass changes on the subsurface. However, the magnetic gradients have little been applied since Swarm launched. A localized magnetic modeling method is useful in taking an account for a region where data availability was limited or of interest was special. In particular, computation to get the localized solutions is much more efficient and it has an advantage of presenting high frequency anomaly features with numbers of solutions fewer than the global ones. Besides, these localized basis functions that were done by a linear transformation of the spherical harmonic functions, are orthogonal so that they can be used for power spectrum analysis by transforming the global spherical harmonic coefficients. I anticipate in scientific and technical progress in the localized modeling with the gradient measurements from Swarm and here will do discussion on the results of the localized solution to represent the three vector and six gradient anomalies over the Antarctic area from the synthetic data derived from a global solution of the spherical harmonics for the crustal magnetic anomalies of Swarm measurements.

Spherical and Aspherical RGP Lens Fitting to Epithelium and Endothelium of Rabbit's Cornea -Scanning Electron Microscopy (구면과 비구면 RGP 렌즈 장기 착용시 각막 상피, 내피에 미치는 영향-주사전자현미경적 관찰)

  • Kim, In-Suk;Ryu, Gun-Chang;Chae, Soo-Chul;Jeon, Chang-Jin
    • Applied Microscopy
    • /
    • v.36 no.3
    • /
    • pp.227-234
    • /
    • 2006
  • To investigate the comparative effect of spherical and aspherical RGP lens were worn during 3 weeks on rabbit's cornea. Four white rabbits were worn right eyes with spherical lens and 4 white rabbits were worn right eyes with aspherical RGP lens. Left eyes were served as control. The rabbits were sacrificed at 3 weeks after fitting and observed morphological changes by scanning electron microscopy and also investigate proliferation rate of the corneal epithelium with RGP wearing. After spherical RGP lens wearing, the epithet layer damaged compared to aspherical lens. The superficial cell layer strip off seriously, cell size significantly changed abnormal. Both spherical and aspherical RGP lens fitting group showed so many bacteria and back surface of lens was found like a fern shape. The aspherical RGP lens original material type was some formal than spherical lens. We thought that these pattern was significantly altered with spherical lens by prohibited transmitter oxygen from atmosphere therefore the epithelium shape was changed. This suggested wearing the aspherical lens might be less physiologic than shperical lens fitting.

Change of Spherical Aberration with Aspheric Soft Contact Lens Wear (비구면 소프트콘택트렌즈 착용에 의한 눈의 구면수차 변화)

  • Kim, Jeong Mee;Mun, Mi-Young;Kim, Young Chul;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.365-372
    • /
    • 2012
  • Purpose: To investigate ocular higher order aberrations (HOA) and spherical aberration changes caused by an aspheric soft contact lens designed to reduce spherical aberration (SA) of the eye. Methods: Fifty subjects who have successfully experienced soft contact lenses were refitted with aspheric design (Soflens Daily Disposable: SDD, Bausch+Lomb) soft contact lens. Ocular higher order aberrations (HOA) and stand alone SA were measured and analyzed for a 4-mm pupil size using Wave-Scan Wavefront$^{TM}$ aberrometer (VISX, Santa Clara, CA, USA). High and low contrast log MAR visual acuity and contrast sensitivity function (CSF) were also measured under photopic and mesopic conditions (OPTEC 6500 Vision Tester$^{(R)}$). All measurements were conducted monocularly with an undilated pupil. Results: The RMS mean values for total HOA with SDD contact lenses were significantly lower than those at with unaided eyes (p<0.001) and a reduction for SA in the SDD was close to the baseline SA (zero ${\mu}m$) (p<0.001). For the SDD lens, there was a statistically significant correlation between the changes in the total HOA and the contact lens power (r=0.237, p=0.018) as well as between the changes in SA and the lens power (r=0.324, p=0.001). High contrast visual acuity (HCVA) and low contrast visual acuity (LCVA) with SDD lenses were $-0.063{\pm}0.062$ and $0.119{\pm}0.060$, respectively under photopic and $-0.003{\pm}0.063$ and $0.198{\pm}0.067$, respectively under mesopic condition. Contrast Sensitivity Function (CSF) with SDD lenses under both photopic and mesopic conditions was $3.095{\pm}0.068$ and $3.087{\pm}0.074$, respectively. Conclusions: The SDD contact lens designed to control SA reduced the total ocular HOA and SA of the eye, resulting in compensating for positive SA of the eyes. Thus, the optical benefits of the lens with SA control would be adopted for improving the quality of vision.

Changes in Spherical Aberration and Coma Aberration after Wearing Aspheric Soft Contact Lens in Young Myopes (젊은 성인 근시안에서 비구면 소프트 콘택트렌즈 착용 후 구면수차와 코마수차의 변화)

  • Lim, Dong-Kyu;Kwon, Hyeok;Lee, Koon-Ja
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.469-482
    • /
    • 2018
  • Purpose : We investigated the change of spherical and comma aberrations after wearing aspheric soft contact lens (ASCL) in young myopes. Methods : Fifty young myopes ($23.15{\pm}1.70years$, spherical equivalent: $-2.90{\pm}1.75D$) were recruited and refractive errors were corrected using ASCL (Biotrue, Bausch+Lomb, USA). High order aberrations were measured in the 4 mm pupil size using the wavefront analyze and pupil sizes were measured with a pupillometer at the modes of scotopic condition (light off) at 3.5 m in the 100 lx illuminance condition. Results : Spherical aberrations and coma aberration of the 20s myopes were $0.026{\pm}0.031{\mu}m$ and $0.078{\pm}0.039{\mu}m$ respectively, and $0.019{\pm}0.026{\mu}m$ and $0.082{\pm}0.038{\mu}m$ after ASCL wear that spherical aberration was decreased and coma aberration was increased. However, spherical aberration was decreased in the 68% of the subject have positive spherical aberration, and increased in the 11% of the subject have negative spherical aberration. Coma aberration was increased in the 53% of the subject, did not change in the 19% of the subjects, and decreased in the 28% of the subject. Spherical aberration was not different with the refractive errors in low and moderate myopies, however, coma aberrations was higher in the higher myopes. Conclusion : In a scotopic condition without accommodation stimuli, spherical aberration is decreased after wearing ASCL, however in the subject have negative spherical aberration spherical aberration could be increased, and which is thought to be the influence of contact lens design and pupil size.

4 반사경 ANASTIGMAT 의 ZOOMING 에 관한 연구

  • 나승유;이상수
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1988.06a
    • /
    • pp.59-67
    • /
    • 1988
  • 연속적으로 aplanat 조건을 만족하는 4 반사경의 zooming에서 aplanat 4구면 반사광학계가 갖는 astigmatism을 줄이기 위하여 4구면 중 하나의 반사경에 원추곡면을 사용함으로써 줌 궤적상의 한점에서 anatsigmat 조건을 만족하도록 하였다. 이방법에 의한 astigmatism 의 보정효과는 제 1 면에 ellipsoid를 사용하였을 때 가장 우수하였다.

  • PDF

A Relationship between Corneal Eccentricity and Stable Centration of RGP Lens on Cornea (각막 이심률과 RGP 렌즈의 중심안정위치와의 상관관계)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.373-380
    • /
    • 2012
  • Purpose: The present study was performed to investigate a relationship between the stable centrations of spherical RGP lens and aspherical RGP lens on cornea and corneal eccentricity. Methods: Two RGP lenses with different designs were fitted in alignment, steep or flat on total 84 eyes having corneal eccentricity of 0.28~0.78. The stable centration of lenses on cornea was analyzed by taking photographs with a high-speed digital camera. Results: The stable centrations of spherical and aspherical RGP lenses in horizontal direction were decentrated to temporal side. More centration to median side was shown when corneal eccentricity was larger. The difference between the stable centrations of spherical and aspheric RGP lenses according to corneal eccentricity was bigger when the fitting state was flatter. The difference in the stable centrations of aspherical RGP lens was smaller than that of spherical RGP lens regardless of fitting status. The stable centrations of spherical and aspherical RGP lenses in vertical direction were located below corneal apex regardless of fitting status however, there was no significant difference analyzed by the variation of corneal eccentricity. However, there were many cases that RGP lenses were in upper eyelid with increasing corneal eccentricity. Conclusions: The consideration of corneal eccentricity is required for RGP lens fitting and manufacturing aspherical RGP lens since the stable centration of spherical RGP lens as well as aspherical RPG lens' centration was changed depending on corneal eccentricity.

3D Model Retrieval based on Spherical Coordinate System (구면좌표계 기반에서 3차원 모델 검색)

  • Song, Ju-Whan;Choi, Seong-Hee
    • 전자공학회논문지 IE
    • /
    • v.46 no.1
    • /
    • pp.37-43
    • /
    • 2009
  • In this paper, we propose a new algorithm for 3D model retrieval based on spherical coordinate system. We obtains sample points in a polygons on 3D model. We convert a point in cartesian coordinates(x, y, z) to it in spherical coordinate. 3D shape features are achieved by adopting distribution of zenith of sample point in spherical coordinate. We used Osada's method for obtaining sample points on 3D model and the PCA method for the pose standardization 3D model. Princeton university's benchmark data was used for this research. Experimental results numerically show the precision improvement of proposed algorithm 12.6% in comparison with Vranic's depth buffer-based feature vector algorithm.

Study of an Aspherical Lens Design Method for Removing the Spherical Aberration of a Human Eye (눈의 구면수차 제거를 위한 비구면 렌즈 설계 기법 연구)

  • Kim, Ji Sung;Kim, Dong Min;Jin, Jong Hyun;Kim, Young Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.6
    • /
    • pp.299-305
    • /
    • 2015
  • Using Snell's Law without approximation, we analyzed focal points for parallel rays incident upon the cornea of a human eye. To calculate a ray's incident angle versus incident height for focusing on the same point, we used the ray reverse tracing method. We derived the theoretical conditions for an aspherical lens to remove the spherical aberration caused by a human eye. In this research, we held the rear surface of the lens to be spherical, for simple calculation, and calculated the lens curvature of the front surface to design an aspherical surface.