• Title/Summary/Keyword: 구동 장치

Search Result 1,730, Processing Time 0.031 seconds

Comparison of Pulsatile and Non-Pulsatile Extracorporeal Circulation on the Pattern of Coronary Artery Blood Flow (체외순환에서 박동 혈류와 비박동 혈류가 관상동맥 혈류양상에 미치는 영향에 대한 비교)

  • Son Ho Sung;Fang Yong Hu;Hwang Znuke;Min Byoung Ju;Cho Jong Ho;Park Sung Min;Lee Sung Ho;Kim Kwang Taik;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.101-109
    • /
    • 2005
  • Background: In sudden cardiac arrest, the effective maintenance of coronary artery blood flow is of paramount importance for myocardial preservation as well as cardiac recovery and patient survival. The purpose of this study was to directly compare the effects of pulsatile and non-pulsatile circulation to coronary artery flow and myocardial preservation in cardiac arrest condition. Material and Method: A cardiopulmonary bypass circuit was constructed in a ventricular fibrillation model using fourteen Yorkshire swine weighing $25\~35$ kg each. The animals were randomly assigned to group I (n=7, non-pulsatile centrifugal pump) or group II (n=7, pulsatile T-PLS pump). Extra-corporeal circulation was maintained for two hours at a pump flow of 2 L/min. The left anterior descending coronary artery flow was measured with an ultrasonic coronary artery flow measurement system at baseline (before bypass) and at every 20 minutes after bypass. Serologic parameters were collected simultaneously at baseline, 1 hour, and 2 hours after bypass in the coronary sinus venous blood. The Mann-Whitney U test of STATISTICA 6.0 was used to determine intergroup significances using a p value of < 0.05. Result: The resistance index of the coronary artery was lower in group II and the difference was significant at 40 min, 80 min, 100 min and 120 min (p < 0.05). The mean velocity of the coronary artery was higher in group II throughout the study, and the difference was significant from 20 min after starting the pump (p < 0.05). The coronary artery blood flow was higher in group II throughout the study, and the difference was significant from 40 min to 120 min (p < 0.05) except at 80 min. Serologic parameters showed no differences between the groups at 1 hour and 2 hours after bypass in the coronary sinus blood. Conclusion: In cardiac arrest condition, pulsatile extracorporeal circulation provides more blood flow, higher flow velocity and less resistance to coronary artery than non-pulsatile circulation.

A Design of Fire-Command Synchronous Satellite Pyrotechnic Circuit (점화 명령에 동조된 인공위성 파이로테크닉 회로 설계)

  • Koo, Ja Chun;Ra, Sung Woong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.81-92
    • /
    • 2013
  • The satellite includes many release mechanisms such as solar array deployment, antenna deployment, cover to protect contamination in scientific equipment, pyro value of the propulsion subsytem, and bypass device in Li-Ion cell module. A drive the initiators is a critical to the successful mission because the initiators of release mechanism driving by the pyrotechnic circuit is operated in single short. The pyrotechnic circuit has to provide switching network for safety. A typical switching network has defect consisting of high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit is required some form of power conditioning to reduce the peak power demanded from the bus if the initiators are to be fired from the main bus. This paper design a pyrotechnic circuit synchronized to the fire-command to activate the fire switch to overcome use high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit provides a current limited widow pulse for fire current synchronized to the fire-command to insure that fire switch will only carry the current but never switch it. The current limited widow pulse for fire current can be possible to use low current rating and light mass switch in switching network. The current limit function in the pyrotechnic circuit reduces supply voltage to initiator and provides the effect of power conditioning function to reduce peak bus power. The pyrotechnic circuit to apply satellite development on geostationary orbit is verified the function by test in development model.

Design of the self-oscillation UV flash lamp power supply and the characteristic of its operation using self-resonance of the transformer (트랜스포머의 자가 공진(Self-Resonance)특성을 이용한 자가 발진(Self-Oscillation) UV(Ultra Violet) 발생 플래시램프 전원장치설계 및 그 동작 특성)

  • Kim, Shin-Hyo;Cho, Dae-Kweon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.48-55
    • /
    • 2014
  • These Xenon flashlamp power supply for Ultra Violet has converter with high voltage conversion ratio. General model is composed of transformer with high voltage conversion ratio and voltage doubler rectifier circuit. Purpose of power supply leads dielectric breakdown of Xenon flashlamp and passes current rapidly. When passing current, it has to limit current to avoid over-heat, damage of electrode and acceleration of gas oxidation which are cause of performance degradation of lamps. Generally, inductors and resistors, which are called as "Ballast," are used to limit currents. Generally, Transformer has high turn ratio to make high voltages. But we can get high voltages using the transformer with low turn ratio which is driven with self resonance. Also, an advantage of self resonance is to make a circuit simply through impedance of transformer in resonance frequency which filters output voltage. As using an unique impedance of transformer, the circuit does not need other impedance elements like the ballast. So the power supply assures high efficiency of the arc discharge.

The Developed Study for SMPS to Protect the Noise and Inrush Current at LED Lighting Source (LED 광원에서 잡음 및 돌입전류 방지를 위한 스위칭모드 전원공급 장치 (SMPS) 개발 연구)

  • Chung, Chansoo;Hong, Gyujang;We, Sungbok;Yu, Geonsu;Kim, Mijin
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.577-582
    • /
    • 2016
  • This Study focused on the development of SMPS (Switching Mode Power Supply) to supply the constant votage and current nevertheless LED fluorescent Light generated the electric noise (with Harmonics) and Inrush current at instant time of turn-on and off. Recently, according to the Green policy in government, the LED fluorescent Lighter showed the rapidly increasing tend as indoor and outdoor Lighter. But, because of costs, LED fluorescent Light not considered and neglected the following items; power factor, efficiency, Harmonics and Inrush current. So, we are developed the SMPS about 3 key issues as follows: 1st, power factor and efficiency is 85%. 2nd, the switching noisy by harmonic is minimized. 3rd, the Inrush current at turn on and off time is reduced the minimum 0.3 A after $100{\mu}sec$ on turnon time. The proposed SMPS adjusted by LNK 409 driver (included the high frequency modulation function). Although, the developed SMPS maintained the about 85% of power factor and efficiency. but, the SMPS must be generated low heat by the variation of minute load current at switching timing. To improve the above weak point, the developed SMPS have the feedback monitoring circuit between input side and output side to maintain the power factor and efficiency. Also, we are studied the time-constant of control circuit to output the constant voltage and current nevertheless the load disturbance of LED lighting. The LED fluorescent Light of 46W is checked the above items.

Wireless Energy and Data Transmission Using Inductive Coupling (유도결합방식에 의한 무선 에너지 및 데이터 전송)

  • Lee, Joon-Ha
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.42-48
    • /
    • 2008
  • Bio-implantable devices such as heart pacers, gastric pacers and drug-delivery systems require power for carrying out their intended functions. These devices are usually powered through a battery implanted with the system or are wired to an external power source. This paper describes an inductive power transmission link, which was developed for an implantable stimulator for direct stimulation of denervated muscles. The carrier frequency is around 1MHz, the transmitter coil has a diameter of 46mm, and the implant coil is 46mm. Data transmission to the implant with amplitude shift keying (ASK) and back to the transmitter with passive telemetry can be added without major design changes. We chose the range of coil spacing (2 to 30mm) to care for lateral misalignment, as it occurs in practical use. If the transmitter coil has a well defined and reliable position in respect to the implant, a smaller working range might be sufficient. Under these conditions the link can be operated in fixed frequency mode, and reaches even higher efficiencies of up to 37%. The link transmits a current of 50 mA over a distance range of 2-15 mm with an efficiency of more than 20% in tracking frequency. The efficiency of the link was optimized with different approaches. A class E transmitter was used to minimize losses of the power stage. The geometry and material of the transmitter coil was optimized for maximum coupling. Phase lock techniques were used to achieve frequency tracking, keeping the transmitter optimally tuned at different coupling conditions caused by coil distance variations.

  • PDF

Issues and Debugging Methodology for Porting TinyOS on a Small Network Embedded System (소형 네트워크 임베디드 시스템에 TinyOS 이식 과정에서의 이슈 및 디버깅 기법)

  • Kim, Dae-Nam;Kim, Kyo-Sun
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.45 no.6
    • /
    • pp.94-105
    • /
    • 2008
  • Numerous platforms have been developed for ZigBee-based network embedded systems. Also, operating systems like TinyOS have been installed to facilitate efficient implementation of wireless sensor network applications which collect data, and/or execute commands. First of all, porting an operating system on a new platform may need invention of a substitute for a required but unsupported hardware component. This paper presents a multiplexed virtual system timer for a platform without a counter comparator which we have contrived to emulate by using an extra counter. Such porting also injects unexpected faults which cause a variety of painful failures. Unfortunately, TinyOS requires to handle a lot of asynchronous hardware interrupts which are hard to trace during debugging. Besides, simulators are not available for a new platform since the models of hardware on the platform are not usually developed, yet. We propose novel instrumentation techniques which can be used to effectively trace the bugs in such lack of debugging environment. These techniques are used to identify and fix a great deal of nasty issues in porting TinyOS 2.0 on MG2400 and MG2455 platforms made by RadioPulse Inc.

Experimental Investigation on Torsional Analysis and Fracture of Tripod Shaft for High-speed Train (고속열차용 트리포드 축의 비틀림 해석 및 파단에 대한 실험적 연구)

  • Lee, Joo Hong;Kim, Do Sik;Nam, Tae Yeon;Lee, Tae Young;Cho, Hae Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.11
    • /
    • pp.979-986
    • /
    • 2016
  • The tripod shafts of constant-velocity joint are used in both the trains KTX and KTX-sanchon. It is an important component that connects the motor reduction unit and the axle reduction unit in a power bogie. The tripod shaft not only transmits drive and brake torque in the rotational direction, but also slides in the axial direction. If the drive system is loaded with an excessive torque, the fuse part of the shaft will be fractured firstly to protect the other important components. In this study, a rig was developed for conducting torsion tests on the tripod shaft, which is a type of mechanical fuse. The tripod shafts were subjected to torsional fracture test and torsional fatigue test on the rig. The weak zone of the tripod shaft was identified, and its fatigue life was predicted using finite element analysis (FEA). After analyzing the FEA results, design solutions were proposed to improve the strength and fatigue life of the tripod shaft. Furthermore, the deterioration trend and time for failure of the tripod shaft were verified using the hysteresis loops which had been changed with the advancement of the torsional fatigue test.

A Brake Pad Wear Compensation Method and Performance Evaluation for ElectroMechanical Brake (전기기계식 제동장치의 제동패드 마모보상방법 및 성능평가)

  • Baek, Seung-Koo;Oh, Hyuck-Keun;Park, Choon-Soo;Kim, Seog-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.581-588
    • /
    • 2020
  • This study examined a brake pad wear compensation method for an Electro-Mechanical Brake (EMB) using the braking test device. A three-phase Interior Permanent Magnet Synchronous Motor (IPMSM) was applied to drive the actuator of an EMB. Current control, speed control, and position control were used to control the clamping force of the EMB. The wear compensation method was performed using a software algorithm that updates the motor model equation by comparing the motor output torque current with a reference current. In addition, a simple first-order motor model equation was applied to estimate the output clamping force. The operation time to the maximum clamping force increased within 0.1 seconds compared to the brake pad in its initial condition. The experiment verified that the reference operating time was within 0.5 seconds, and the maximum value of the clamping force was satisfied under the wear condition. The wear compensation method based on the software algorithm in this paper can be performed in the pre-departure test of rolling stock.

Development of Processing Program for Audio-vision System Based on Auditory Input (청각을 이용한 시각 재현장치의 분석프로그램 개발)

  • Heo, Se-Jin;Bang, Sung-Sik;Seo, Jee-Hye;Choi, Hyun-Woo;Kim, Tae-Ho;Lee, Na-Hee;Lee, Yu-Jin;Park, Ji-Won;Lee, Hui-Joong;Won, Chul-Ho;Lee, Jong-Min
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.1
    • /
    • pp.58-65
    • /
    • 2010
  • The final goal of our research is developing not a simple collision a1ann equipment for the blinded walkers, but the apparatus (Audio- Vision System) which can simulate vision based on auditory information so that the blinds can figure the three dimensional space in front of them. On the way to the final goal, in this study, simulation software was developed and verified. Thirty normal volunteers were included in the subject group and the average age Was 25.8 years old. After being accustomed to the system by evaluating 10 blinded virtual spaces, the volunteers performed test using another set of 10 blinded virtual spaces. The results of test were scored by shape, center, margin, and gradient surface of objects in virtual space. The score of each checking point ranged from 1 to 5, and the full score was converted to 100. As results of this study, the total score ranged from 77 to 97 with the average of 88.7. In this study, a simulation software was developed and verified to have acceptable success rale. By combining to visual sensors, the vision-reconstruction system based on auditory signal (Audio-vision System) may be developed.

Non-Marker Based Mobile Augmented Reality Technology Using Image Recognition (이미지 인식을 이용한 비마커 기반 모바일 증강현실 기법 연구)

  • Jo, Hui-Joon;Kim, Dae-Won
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.4
    • /
    • pp.258-266
    • /
    • 2011
  • AR(Augmented Reality) technology is now easily shown around us with respect to its applicable areas' being spreaded into various shapes since the usage is simply generalized and many-sided. Currently existing camera vision based AR used marker based methods rather than using real world's informations. For the marker based AR technology, there are limitations on applicable areas and its environmental properties that a user could immerse into the usage of application program. In this paper, we proposed a novel AR method which users could recognize objects from the real world's data and the related 3-dimensional contents are also displayed. Those are done using image processing skills and a smart mobile embedded camera for terminal based AR implementations without any markers. Object recognition is done from the comparison of pre-registered and referenced images. In this process, we tried to minimize the amount of computations of similarity measurements for improving working speed by considering features of smart mobile devices. Additionally, the proposed method is designed to perform reciprocal interactions through touch events using smart mobile devices after the 3-dimensional contents are displayed on the screen. Since then, a user is able to acquire object related informations through a web browser with respect to the user's choice. With the system described in this paper, we analyzed and compared a degree of object recognition, working speed, recognition error for functional differences to the existing AR technologies. The experimental results are presented and verified in smart mobile environments to be considered as an alternate and appropriate AR technology.