• Title/Summary/Keyword: 교합력 측정장치

Search Result 14, Processing Time 0.031 seconds

Changes in occlusal force and occlusal contact area after orthodontic treatment (교정 치료 후 교합력, 교합면적의 변화)

  • Choi, Yoon-Jeong;Chung, Choo-Ryung J.;Kim, Kyung-Ho
    • The korean journal of orthodontics
    • /
    • v.40 no.3
    • /
    • pp.176-183
    • /
    • 2010
  • Objective: This study was performed to evaluate functional changes of occlusion after orthodontic treatment by measuring the occlusal force (OcFr) and occlusal contact area (OcAr), and to compare OcFr and OcAr change according to premolar extractions. Methods: Data were obtained from 74 patients who had finished orthodontic treatment using fixed appliance aged between 18 and 40 years. Subjects were divided into groups who had four premolars extractions or non-extraction (Male extraction-16, Male nonextraction-18, Female extraction-19, Female nonextraction-21). All subjects were asked to bite pressure-sensitive sheets into maximum intercuspation with maximum bite force, and OcFr and OcAr were evaluated by measuring the sheet with a CCD camera. Records were taken right after debonding, 1 week, 1 month, 3 months, 6 months and 1 year after debonding. Results: OcFr and OcAr increased gradually in all groups during the 1 year retention period (p < 0.05). Male groups showed higher OcFr and OcAr than female groups throughout the retention periods (p < 0.05). There were no statistically significant differences of OcFr and OcAr between extraction and non-extraction groups in both males and females (p > 0.05). Conclusions: Occlusion was improved functionally throughout the 1 year retention, and premolar extraction did not induce a decline in the functional aspect of occlusion.

Factors that affect the bite force measurement (교합력 측정에 영향을 주는 요인)

  • Im, Ji-Ho;Lee, Wonsup;Kim, Myung-Joo;Lim, Young-Jun;Kwon, Ho-Beom
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • Mastication is the process to help digestion by chewing or grinding food. Masticatory system consists of maxilla, mandible, temporomandibular joints, ligaments, dentitions, and musculatures. Assessing the bite force can be one of the methods to estimate the masticatory system. Bite force is influenced by facial morphology, age, sex, periodontal status, temporomandibular joint disorder and dental condition, and so forth. In general, higher maximum bite force is seen in those who have a square-shaped face and in male rather than female. In addition, bite force tends to be increased by age 20, maintained constantly until age 40 - 50, and then decreased. Periodontal disease is known as a causative factor for decreased bite force while temporomandibular disorder (TMD) remains controversial as to whether it affects the force. The status of teeth is considered as an important factor to determine the maximum bite force.

Relationship between maximum bite force and facial skeletal pattern (최대 교합력과 안면 골격 형태에 관한 연구)

  • Choi, Won-Cheul;Kim, Tae-Woo
    • The korean journal of orthodontics
    • /
    • v.33 no.6 s.101
    • /
    • pp.437-451
    • /
    • 2003
  • The purpose of this study was to measure maximum bite force and to investigate its relationship with anteroposterior, vertical, and transverse facial skeletal measurements. From among the dental students at the College of Dentistry, forty subjects (26 male and 14 female) were selected. With two sets of strain gauge, maximum bite force at the right and left first molars and anterior teeth was measured in the morning and afternoon. After taking lateral and posteroanterior cephalograms, fifty and nineteen variables were evaluated, respectively Paired t-tests and an independent t-test were done and correlation coefficients were obtained. 1. The maximum bite force at the first molars was $68.0\pm13.9kg$. in males and $55.6\pm10.5kg$ in females (p<0.05) while the force at the anterior teeth was $8.4\pm4.9kg\;and\;1.1\pm3.4kg$ respectively (p<0.05). 2. Some tendency for a greater value of maximum bite force at the preferred side was observed but not statistically significant (p>0.05). 3. Significant difference was observed between the strong bite force group and the weak bite force group in some cephalometric and other measurements (p<0.05). N-S-Ar, S-Ar-Go, FH-Hl, IMPA and MMO showed a significant difference in posterior maximum bite force (P). N-S-Ar and FH-H1 also showed a significant difference in anterior maximum bite force (A). 4. Several cephalometric variables showed some correlation with maximum bite force (p<0.05). N-S-Ar, S-Ar-Go, UGA, FH-H6, FH-H1, body weight and MMO were significantly correlated with posterior maximum bite force (P). Go-Me, P-1 and IMPA were significantly correlated with anterior maximum bite force (A).

Nocturnal Bruxism and Botulinum Toxin Effect on the Subjects with Masseteric Hypertrophy (야간 이갈이와 교근비대 환자의 보툴리눔 독소 주사 효과)

  • Sohn, Seung-Mahn;Chung, Gi-Chung;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.337-346
    • /
    • 2007
  • This study aimed to evaluate a relation of bruxism with clinical effects of botulinum toxin type A(BTX-A) injection. 5 bruxers and 5 nonbruxers with bilateral masseter hypertrophy were participated in this study. After injecting 25 unit of BTX-A(Allergen Inc, $Botox^{(R)}$) into each masseter muscle, the thickness of masseter(Mm) and anterior temporalis(Ta) muscles was measured by ultrasonography and the maximum bite force was evaluated during a 9-month period. Self-estimation on the recovery of occlusal force during mastication was done as well. Regardless of presence of bruxsim, all subjects showed significantly reduced Ms thickness(p<0.001) and maximum bite force at $1^{st}$ molars(p=0.027) with their peak at 3 months after injection, which then started to return. No significant difference was observed in Ta thickness and the bite force at the central incisors. While self-estimated occlusal force was the least at 2 weeks after injection and then rapidly returned to the baseline level with full recovery at the time of 6 to 9 months after injection, the maximum bite force measured by bite force recorder did not recover the original value, particularly in the nonbruxer group. It is assumed that nocturnal bruxism can influence recovery of atrophic masseter and decreased occlusal force due to BTX-A injection. These findings suggest a need of occlusal appliance to control bruxism or clenching habit for longer clinical effect of BTX-A injection.

Effect of Mouthguard on Tooth Distortion During Clenching (이악물기 시 발생되는 치아변형에 대한 구강보호장치의 역할)

  • Lee, Yun;Choi, Dae-Gyun;Kwon, Kung-Rock;Lee, Richard Sung-Bok;Noh, Kwan-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.405-417
    • /
    • 2010
  • Previous studies have already shown that mouthguard is effective in protecting jaw bone, teeth and oral tissue against sports trauma. However, other than severe trauma, repetitive force, such as disorders like clenching, cause teeth or oral tissue damage. These kinds of disorders usually present pathologic attrition in the posterior teeth, resorption in alveolar bone, loss of teeth and destruction of occlusion. Wearing a mouthguard is believed to be effective in preventing these disorders. But its effect is not examined thoroughly enough. The purpose of this study is to identify whether mouthguard is effective in reducing strain caused by clenching. Mandibular first molars in the normal occlusal relationship without any history of dental treatment were chosen. Biaxial type strain gauge was placed on the buccal surface of the tooth. Having maximum occlusal force, measured by load cell, as a standard, clenching intensity were divided into three stages; moment of slightly tooth contact, medium bite force (50% of maximum bite force), maximum bite force. Strain occurring in dentition in each stage with and without mouthguard was measured. Changes in strain (on dentition) between each stage and difference in strain, between with or without mouthguard were recorded by PCD-300 analyzer and PCD-30 soft ware. The data was statistically analyzed by Wilcoxon signed rank test. The following results were drawn; Without mouthguard, strain given on dentition increased as the clenching force increased. With mouthguard, strain given on dentition also increased as the clenching force increased. With mouthguard, strain decreased, in all cases of clenching force stages. Data on the moment of slightly tooth contact stage, had no statistical significance. However, with mouthguard, 50-90% of decrease in strain could be obtained in maximum occlusal force, compared to the group without mouthguard. Mouthguard decreased the strain on the dentition, caused by clenching. Therefore, mouthguard seems to be effective in preventing damage on dentition, by acting against clenching, which occurs both consciously and unconsciously during sports activities.

Comparison of Implant Torque Controllers using Detorque Value (풀림토크를 이용한 임플란트 토크조절기의 비교)

  • Huh, Yoon-Hyuk;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.419-432
    • /
    • 2010
  • Various torque generating devices have been developed and employed to apply a proper torque. These devices are usually calibrated by the manufacturer to apply appropriate torque levels for their specific implants and attachments. The purpose of this investigation was to determine and compare the accuracy of the torque controllers. In this study, 4 types of torque controllers were used; torque limiting device(TLD), torque indicating device(TID) and contra angle torque driver(CA), electronic torque controller(ETC). Digital torque gauge was employed to measure the de-torque value. Thirty cycles of tightening and loosening were repeated with each torque controller. All implant torque controllers have shown slight errors and deviations. The contra angle torque driver exhibited the most accurate data. In the limitation of this study, it would be recommended that the implant torque controllers should be checked whether uniformed and precise torque can be generated and a measuring error should be corrected.

Development and Reliability of Intraoral Appliance for Diagnosis and Control of Bruxism (이갈이 진단 및 조절용 구내장치의 개발과 신뢰도 조사)

  • Kim, Seung-Won;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.69-77
    • /
    • 2005
  • The purposes of this study were to develop and introduce a novel intraoral appliance for bruxism composed of power switch and biofeedback device and further to examine inter- and intra-reliability of the appliance prior to clinical tests. The newly-developed appliance consisted of detection sensors, a central processing unit (CPU), a reactor and a storage unit and a displayer. Compact-sized, waterproof switches were selected as bruxism detection sensor and any sensor activation by clenching or grinding event was processed at the CPU and transmitted, by radio wave, to the reactor and storage unit and triggered auditory or vibratory signal, subsequently producing biofeedback to the patient with bruxism. The data on bruxing event in the storage unit can be displayed on the computer, making it possible analyzing frequency, duration and nature of bruxism. Cast models were obtained from ten volunteers with normal occlusion to evaluate reliability of the appliances. For inter-operator reliability on the intraoral appliances, each operator of the two fabricated the appliance for the same subject and compared the minimal contact forces provoking auditory biofeedback reaction in vertical, lateral and central directions. Intra-operator reliability was also investigated on the appliances made by a single operator at two separate times with an interval of two days. Conclusively, the newly-developed appliance is compact and safe to use in oral circumstance and easy to make. Furthermore, it had to be proven reliability excellent enough to apply in clinical settings. Thus, it is assumed that this appliance with the processor and the storage of data and auditory or vibratory biofeedback function is available and useful to analyze and control bruxism.

Analysis of Occlusal Contacts Using Add-picture Method (Add-picture 방법을 이용한 교합접촉점 분석)

  • Park, Ko-Woon;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.45-58
    • /
    • 2013
  • The purpose of this study was to analyze the area of occlusal contact points using visual method. One subject was selected who had Angle Class I, normal dentition, without dental caries, periodontal disease and temporomandibular disorders. Forty times PVS impressions were taken and 10 pairs casts were fabricated using dental super hard stone. After mounting the casts with customized loading apparatus, 78.9kg/f force was loaded as a maximum biting force. In T-Scan method, occlusal contact points measurement was repeated twice. Then, using Photoshop program (Adobe photoshop CS3, Adobe. San Jose, USA), the pixels which indicated occlusal contact points by color was recognized, and the distribution of recognized pixels were calculated to area. In Add picture method, polyether bite material applied to the occlusal surface of the casts. Then, the image of the translucent areas was recorded and classified $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area by the amount of transmitted light. To acquire occlusal surface, the numbers of pixels from the photograph of the contact area indicated cast converted to $mm^2$. The mean occlusal contact area by two methods was statistically analyzed (paired t-test). Part of the red and pink area in T-Scan image were almost equivalent to the $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area in Add picture image. The distribution of occlusal contact points were similar, but the average area of occlusal contact points was wider in T-scan image (P<.05). Pink and red area in T-scan image was wider than $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$ area in Add picture image (P<.05), but similar to $0{\sim}60{\mu}m$area in Add picture image (P>.05). Occlusal contact points in T-scan image did not indicate real occlusal contact points. Occlusal contact areas in T-scan method were enlarged results comparing with those in Add picture method.

A three-dimensional finite element analysis of obturator prosthesis for edentulous maxilla (무치악 구개결손 환자를 위한 폐쇄장치의 삼차원 유한요소 분석)

  • Song, Woo-Seok;Kim, Myung-Joo;Lim, Young-Jun;Kwon, Ho-Beom
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.222-228
    • /
    • 2011
  • Purpose: The purposes of this study were to evaluate the stress distributions and the displacements of obturator for edentulous maxillectomy patients and to compare them with those of complete denture using three-dimensional finite element analysis. Materials and methods: Based on the CT image of edentulous patient, three-dimensional finite element model of edentulous maxillae was constructed. Three-dimensional finite element model of edentulous maxillae with palatal defect was also fabricated. On each model, complete denture and obturator prosthesis were created. Vertical static force of 200 N was applied on the left maxillary premolar and molar region. The von Mises stress values and the displacements of models were analyzed using three-dimensional finite element analysis. Results: Maximum von Mises stress values were recorded in the cortical bones of both models. The von Mises stress value in the complete denture model was 2.73 MPa and 2.69 MPa in the obturator model. High von Mises stress values were also observed on the tissue surface of prosthesis. The maximum value of the displacement in the obturator was higher than that of complete denture. Conclusion: The obturator showed a worse result in terms of stress distribution and displacement than complete denture. In the prosthodontic rehabilitation of edentulous maxillectomy patient accurate impression procedure based on patients'anatomy and application of prosthodontic principle should be considered.

THE CHANCE OF TOOTH NOBILITY FOLLOWING ORTHODONTIC TOOTH MOVEMENT : A SHORT-TERM STUDY (교정적 치아이동 후 치아동요도 변화에 관한 연구)

  • Hwang, Hyeon-Shik;Kim, Jae-Hyuk;Choi, Joon-Kyu;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.3 s.68
    • /
    • pp.379-389
    • /
    • 1998
  • The purpose of the present study was to evaluate the change of tooth mobility following orthodontic tooth movement. Six orthodontic patients which had been treated with edgewise appliance were used. Tooth mobility was measured with Periostest at the time of the removal of orthodontic appliance and 1, 2, 3, 4, 6, 8, 10, 12, 16, 20, 24 weeks after appliance removal. Following results were obtained: 1. Tooth mobility upon the removal of orthodontic appliance showed individual variation while incisor showed greater mobility than the other teeth. 2. Tooth mobility showed continued decrease pattern until 24 weeks after appliance removal. 3. While maxillary incisors showed continued decrease pattern during the study period, the other teeth showed steep decline pattern during the first 12 weeks and gentle slope during the second 12 weeks. 4. The tooth mobility of the maxillary second premolar showed the most typical change in terms of the consistency of the decline. 5. There were no significant differences of tooth mobility between heavy- and light-contacted anterior teeth during experimental period. The results of the present study suggested that periodontal reorganization is not completed even in 24 weeks following orthodontic tooth movement.

  • PDF