• Title/Summary/Keyword: 교정측정능력

Search Result 59, Processing Time 0.025 seconds

Effect of Overcorrection (-)Lens on Stereo-acuity and Angle of Deviation in Intermittent Exotropia (간헐외사시에서 과교정 (-)렌즈가 입체시 및 사시각에 미치는 영향)

  • Kim, Young Cheong;Park, Sang Woo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.305-311
    • /
    • 2013
  • Purpose: This study was conducted to evaluate the effect of prescription of overcorrection (-) lens, which is the one of the non-surgical treatments, on stereo-acuity and angle of deviation in intermittent exotropia. Methods: Twenty four children with intermittent exotropia were enrolled from October 2011 to December 2011. The angle of deviation(${\Delta}$), stereo-acuity (arcsec), monocular and binocular visual acuity (BVA, LogMAR), control of exodeviation and fusional ability using Worth 4 dot test were evaluated at near (33 cm) and far (6 m), under the overcorrecting (-)lens of -1.00, -.00, and -.00 D. Results: As a baseline finding, the angle of exodeviation was $20.9{\pm}9.7$ at near and $23.0{\pm}7.5$ at far. The angle of exodeviation at near decreased to $18.5{\pm}10.0$ (p<0.01), $15.8{\pm}9.0$ (p<0.01), $14.0{\pm}9.1$ (p<0.01) compared with baseline angle of exodeviation at near, as increasing diopters of (-) lens from -.00 D, -2.00 D and -.00 D, respectively. The angle of exodeviation at far also decreased to $21.4{\pm}5.2$ (p=0.01), $19.6{\pm}6.3$ (p<0.01) compared with baseline, as increasing minus lens from -2.00 D and -3.00 D, respectively. However, BVA, control of exodeviation, fusional ability and stereo-acuity showed no significant decrease despite of increasing diopters of (-)lens. Conclusions: The prescription of overcorrection (-)lens is an effective therapeutic method in intermittent exotropia which can reduce the near and far angle of exodeviation, and binocular visual acuity and stereo-acuity maintained without significant decrease despite of application of overcorrection (-)lens.

Relationship of Oral Health Status and Oral Health Care to the Quality of Life in Patients of Dental Hospitals and Clinics (치과내원 환자들의 구강건강상태와 구강건강관리 행태에 따른 삶의 질)

  • Yoon, Hyun-Seo
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.594-602
    • /
    • 2015
  • The purpose of this study was to examine the relationship of oral health status and oral health care to life. The subjects in this study were the patients who visited dental hospitals and clinics in several regions for seven months from March 2013. They got dental checkups, and a survey was conducted. The patients who received general treatment scored highest in Oral Health Impact Profile-14. Among the subfactors, the patients who received general treatment scored higher in functional limitation (8.27), physical pain (7.24), physical restrictions (7.90), social restrictions (7.79), physical limitations (8.14) and social difficulties (8.24). The patients who received orthodontic treatment scored higher in handicap (8.78). All the differences were statistically significant. As for gender gaps, the men scored higher in every factor. By age group, the older patients led a worse quality of life. By occupation, the homemakers mostly led a worse quality of life, and the patients who had no systemic diseases lived a better quality of life. All the differences were significant. Concerning self-rated health status and self-rated oral health state, the patients who found themselves to be in better health and in better oral health led a better quality of life. The differences were significant. Regarding oral health care, the patients who didn't get regular dental checkups and who could visit a dental clinic whenever they had a pain lived a better quality of life. The differences were significant. In terms of oral health status, a higher quality of life was found among the patients who had sound teeth, whose teeth received no sealant treatment, whose teeth received no filling therapy, who had no missing tooth, whose teeth received no prosthetic treatment and who had no dental implants teeth.

Analysis of Output Constancy Checks Using Process Control Techniques in Linear Accelerators (선형가속기의 출력 특성에 대한 공정능력과 공정가능성을 이용한 통계적 분석)

  • Oh, Se An;Yea, Ji Woon;Kim, Sang Won;Lee, Rena;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.185-192
    • /
    • 2014
  • The purpose of this study is to evaluate the results for the quality assurance through a statistical analysis on the output characteristics of linear accelerators belonging to Yeungnam University Medical Center by using the Shewhart-type chart, Exponentially weighted moving average chart (EWMA) chart, and process capability indices $C_p$ and $C_{pk}$. To achieve this, we used the output values measured using respective treatment devices (21EX, 21EX-S, and Novalis Tx) by medical physicists every month from September, 2012 to April, 2014. The output characteristics of treatment devices followed the IAEA TRS-398 guidelines, and the measurements included photon beams of 6 MV, 10 MV, and 15 MV and electron beams of 4 MeV, 6 MeV, 9 MeV, 12 MeV, 16MeV, and 20 MeV. The statistical analysis was done for the output characteristics measured, and was corrected every month. The width of control limit of weighting factors and measurement values were calculated as ${\lambda}=0.10$ and L=2.703, respectively; and the process capability indices $C_p$ and $C_{pk}$ were greater than or equal to 1 for all energies of the linear accelerators (21EX, 21EX-S, and Novalis Tx). Measured values of output doses with drastic and minor changes were found through the Shewhart-type chart and EWMA chart, respectively. The process capability indices $C_p$ and $C_{pk}$ of the treatment devices in our institution were, respectively, 2.384 and 2.136 for 21EX, 1.917 and 1.682 for 21EX-S, and 2.895 and 2.473 for Novalis Tx, proving that Novalis Tx has the most stable and accurate output characteristics.

The Influence of the Variation of Conic Coefficient of the Front Surface on RMS Spot Diameter (전면의 conic 계수 변화가 착락원 크기에 미치는 영향)

  • Park, Seong-Jong;Ju, Seok-Hee;Sim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.77-83
    • /
    • 2003
  • To investigate the influence of the variation of conic coefficient of the front surface on the RMS SD(Root Mean Square Spot Diameter) in a back focal plane, we use programs which are Cove V and LOSA 2.0. We consider a spectacle lens with back vertex power of -4.00D, diameter of 70 mm, the front surface powers which are 2.00D, 4.00D, 6.00D, and 8.00D, and the indices which are $n_d$=1.498, 1.523, 1.586, and 1.660, respectively. The RMS SD in the back focal plane and the thickness of an aspherical tens having the optimized conic constant are smaller than those of a spherical lens. The RMS SD in the back focal plane decreases as the front surface power decreases. From these results, we determine the optimized conic constant to improve the optical image quality and decrease RMS SD in the back focal plane.

  • PDF

A Empirical Study about the Impact of the Calibration and Measurement Capability(CMC) on Korean Trade (교정 및 측정능력(CMC)이 한국의 무역에 미치는 영향에 관한 실증분석)

  • Park, Jookeun;Han, Seong;Park, Jongseon
    • Journal of Technology Innovation
    • /
    • v.25 no.2
    • /
    • pp.127-152
    • /
    • 2017
  • With the advent of the WTO system in 1995, non-tariff barriers including technical barriers to trade(TBT) has become one of the important issues in world trade order. The purpose of this study is to analyse an impact of the calibration and measurement capabilities(CMC), the degree of equivalence of national measurement standards which is maintained by NMIs to provide governments with a technical foundation for wider agreements related to international trade. The results of the analysis using the gravity model with the proxy of the CMC shows that the CMC has a positive impact on Korean trade. Particularly, it was estimated that the CMC registered by high-income economies has more impact on Korean trade than those by low income economies. This implies that the countries highly dependent upon foreign trade like Korea need to have much more interest in the investment into measurement standards and science which is generally considered to be a public goods.

Effect of Fluoride Recharging on Fluoride Release and Surface Properties of Orthodontic Bracket Adhesives (불소 적용 후 교정용 브라켓 접착제 종류에 따른 불소 재흡수성과 표면 변화에 관한 연구)

  • Byeon, Seon Mi
    • Journal of dental hygiene science
    • /
    • v.18 no.4
    • /
    • pp.218-226
    • /
    • 2018
  • The aim of this study was to compare fluoride release and surface changes according to different orthodontic bracket adhesives the application of fluoride products. We used non-fluoridated composite resin Transbond fluoridated composite resins Blugloo and LightBond, resin-modified glass ionomer Rely $X^{TM}$ Luting 2, and conventional glass ionomer Fuji $I^{(R)}$. Fluoride release of five orthodontic bracket adhesives and fluoride release ability after application of three fluoride products (1.23% acidulated phosphate fluoride gel, Tooth Mousse $Plus^{(R)}$, Fluor Protector, and a toothbrush with sodium fluoride-containing toothpaste) were measured using a fluoride electrode that was connected to an ion analyzer. After 4 weeks of fluoride application, the surface roughness and surface morphology were examined using a surface roughness tester and field emission scanning electron microscopy. The amounts of fluoride release were observed not only on application of Tooth Mousse $Plus^{(R)}$ and Fluor Protector on resin-modified glass ionomer Rely $X^{TM}$ Luting 2 and Fuji $I^{(R)}$, but also during tooth brushing using fluoride-containing toothpaste. After application of Tooth Mousse $Plus^{(R)}$, except Transbond XT, the surface roughness increased, and all orthodontic adhesives showed a partial drop of micro-particle filler. On application of 1.23% acidulated phosphate fluoride gel on all orthodontic bracket adhesives, their surface roughness increased. To bond the orthodontic bracket, resin-modified glass ionomer Rely $X^{TM}$ Luting 2 and Fuji $I^{(R)}$ adhesives are highly recommended if the amount of fluoride release is considered to confer a preventative effect on dental caries, and among the fluoride products, Tooth Mousse $Plus^{(R)}$ and Fluor Protector are better than 1.23% acidulated phosphate fluoride gel, and these are expected to prevent dental caries even during tooth brushing with fluoride-containing toothpaste.

A Study on the Development of a Lightning Warning System by the Measurement of Electric Field at the Ground (대지전장측정에 의한 뇌경보시스템 개발에 관한 연구)

  • Kil, Gyung-Suk;Lee, Sung-Keun;Song, Jae-Yong;Kim, Jum-Sik;Kwon, Jang-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.250-258
    • /
    • 2001
  • In this study, a lightning warning system (LWS) which can predict a lightning return stroke is developed, and the LWS is based on the measurement of electric field intensity at the ground level. The LWS consist of a rotation-type field mill as an electric field sensor, an impedance changer, a two-stage amplifier, and a microprocessor unit. From the calibration experiment, the frequency bandwidth and the maximum resolution of the LWS are $DC{\sim}200\;[Hz]$ and 73 [V/m], respectively. Also, the LWS can measure the electric field strength caused by a thunderstorm up to 18.7 [kV/m] at the ground. To ensure the sensing ability of the developed LWS in an actual situation, computer simulation using thundercloud models was carried out, and the result showed that the LWS can monitor the movement of thunderclouds within 6 [km] from the observation site.

  • PDF

Development of Video Image-Guided Setup (VIGS) System for Tomotherapy: Preliminary Study (단층치료용 비디오 영상기반 셋업 장치의 개발: 예비연구)

  • Kim, Jin Sung;Ju, Sang Gyu;Hong, Chae Seon;Jeong, Jaewon;Son, Kihong;Shin, Jung Suk;Shin, Eunheak;Ahn, Sung Hwan;Han, Youngyih;Choi, Doo Ho
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.85-91
    • /
    • 2013
  • At present, megavoltage computed tomography (MVCT) is the only method used to correct the position of tomotherapy patients. MVCT produces extra radiation, in addition to the radiation used for treatment, and repositioning also takes up much of the total treatment time. To address these issues, we suggest the use of a video image-guided setup (VIGS) system for correcting the position of tomotherapy patients. We developed an in-house program to correct the exact position of patients using two orthogonal images obtained from two video cameras installed at $90^{\circ}$ and fastened inside the tomotherapy gantry. The system is programmed to make automatic registration possible with the use of edge detection of the user-defined region of interest (ROI). A head-and-neck patient is then simulated using a humanoid phantom. After taking the computed tomography (CT) image, tomotherapy planning is performed. To mimic a clinical treatment course, we used an immobilization device to position the phantom on the tomotherapy couch and, using MVCT, corrected its position to match the one captured when the treatment was planned. Video images of the corrected position were used as reference images for the VIGS system. First, the position was repeatedly corrected 10 times using MVCT, and based on the saved reference video image, the patient position was then corrected 10 times using the VIGS method. Thereafter, the results of the two correction methods were compared. The results demonstrated that patient positioning using a video-imaging method ($41.7{\pm}11.2$ seconds) significantly reduces the overall time of the MVCT method ($420{\pm}6$ seconds) (p<0.05). However, there was no meaningful difference in accuracy between the two methods (x=0.11 mm, y=0.27 mm, z=0.58 mm, p>0.05). Because VIGS provides a more accurate result and reduces the required time, compared with the MVCT method, it is expected to manage the overall tomotherapy treatment process more efficiently.

Implementation of the Posture Stability Monitoring System using Balance Ability Method (균형능력 측정 기법을 이용한 자세안정도 모니터링 시스템 구현)

  • Cha, Sang-Hoon;Choi, Su-Bin;Park, Eun-Ji;Park, Jun-mo;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.537-538
    • /
    • 2016
  • Recently, modern people a lot of frequency of work and seat life by academic is increased, addictive spine for the wrong attitude and the wrong habits are many pelvic disease occurrence. Therefore, in order to induce continuous correct posture to prevent this, the system that can be induced to determine the posture information based on the seating information is requested. In this paper, when the development and inappropriate attitude of the device that is capable of tracking measurement in order to evaluate the attitude stability is detected, let your users know, to correct their attitude through the real-time monitoring It was implemented of categorize to help application.

  • PDF

Effects of Kinesio Taping on Craniovertebral Angle and Balance Ability in Subject with Forward Head Posture

  • Jeon, Yong-Jin;Kim, Gyoung-Mo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.8
    • /
    • pp.145-150
    • /
    • 2020
  • Forward head posture is one of the most recognized types of poor head and neck alignment. Poor head and neck alignment posture is a major contributor to compromised balance and neck pain, due to abnormal joint position sense and proprioception. Kinesio taping is an intervention method used clinically for the management of pain. Kinesio taping may produce its effects through pain reduction, stimulation of blood circulation, induction of muscle relaxation which provides correction of joint position, and providing stability to the muscles and joints without limiting the range of motion. Many studies have proved that kinesio taping has positive effects on the reduction of pain and improves alignment, on the other hand, some studies have not found. Kinesio taping may provide immediate pain relief and improved alignment following the application, but there is insufficient evidence to support sustained relief beyond that time and they recommended future studies to examine the benefits of kinesio taping as this would have a greater value in clinical practice. Therefore, this study is to investigate the effects of kinesio taping on the alignment of head posture and dynamic balance ability in people with forward head posture.