• Title/Summary/Keyword: 관절 간격

Search Result 104, Processing Time 0.027 seconds

Fabrication of complete dentures made with monolithic discs through CAD/CAM using facial scan data and individual tray duplicating temporary denture: a case report (안면스캔 데이터와 임시의치를 복제한 개인 트레이를 활용하여 CAD/CAM을 통한 monolithic disc로 제작한 총의치 수복: 증례 보고)

  • Ju Hyun Kim;Soo-Yeon Shin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.3
    • /
    • pp.158-167
    • /
    • 2023
  • As digital technology has advanced in the field of dentistry, the use of computer-aided design/computer-aided manufacturing (CAD/CAM) has brought changes to the stages of dental treatment. The use of CAD/CAM technology in dental restoration offers clinical efficiency and convenience by reducing production time and appointment intervals, while also simplifying the fabrication process to reduce errors. In this case, digital replication and printing of temporary teeth were used to aid a patient with complex medical histories and physical disabilities. The final impression obtained with silicone impression material included information on the vertical dimension, centric relation, and the angle and length of the anterior teeth, which shortened the production time and appointment intervals and increased patient satisfaction. The final restoration was fabricated using milling and monolithic disc techniques, demonstrating appropriate stability, retention, and support, resulting in functional and aesthetic satisfaction.

Arthroscopic Treatment of Post-traumatic Stiff Shoulder by Rotator Interval Bridging Scar Adhesion - Case Report - (회전근 개 간격의 가교 반흔 유착에 의한 외상성 견관절 강직증의 관절경적 치료 - 증례 보고 -)

  • Kim Young-Mo;Rhee Kwang-Jin;Kim Kyung-Cheon;Byun Byung-Nam
    • Clinics in Shoulder and Elbow
    • /
    • v.7 no.1
    • /
    • pp.41-45
    • /
    • 2004
  • In adhesive capsulitis of the shoulder of no response to nonoperative treatment, an arthroscopic capsular release and manipulation improves range of motion and pain relief. We performed an arthroscopic examination in the stiff shoulder, of which she had no response to nonoperative treatment, after the conservative treatment of a clavicular shaft fracture by motorcycle-driver traffic accident. We found the intra-articular 'rotator interval bridging scar adhesion' between subscapularis tendon and antero-superior glenoid fossa under the rotator interval which was no adhesion and contracture itself. We performed the scar adhesion removal and synovectomy, maintaining the rotator interval. We recommended nonsteroidal anti-inflammatory drug for postoperative pain relief and continuous active and passive range of motion (ROM) exercise to gain motions. Preoperatively, active and passive range of motion were 70° for forward elevation, 60° for abduction and especially 0° for external rotation. After postoperative 2 months, active ROM were 150° for forward elevation, 130° for abduction and 80° for external rotation. After postoperative 6 months, passive and active ROM were full. UCLA score improved from preoperative 9 points to postoperative 29 points.

Effects on Exercise Training in person with Incomplete Hemisection cord injury after Discharge (불완전 척수손상자의 퇴원 후 운동훈련의 효과 사례보고)

  • Park, Mi-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.12 no.4
    • /
    • pp.25-31
    • /
    • 2005
  • 이 사례연구는 2002년 10월 15일 칼에 의한 좌상으로 경추 3-4번의 불완전 척수손상을 입은 25세의 남자 환자가 최초 병원에서 2002년 12월 한달 간의 치료를 마친 후, 2003년 1월 3일부터 4월 28일까지 태릉에 위치한 N 재활센터에서 주 5회 2시간의 자세조절 훈련, 심폐지구력 훈련, 웨이트 훈련, 스포츠(축구, 소프트 볼), 여가활동(등산)의 프로그램을 적용하여 척추손상 환자의 사회적응을 돕기위한 재활 프로그램의 다양화를 꾀하기 위한 기초 선행 작업으로 시작되었다. 신체능력을 평가하기 위한 측정도구는 관절가동범위(Range of Motion), 수동근력검사(Muscle Manual Test), 경직(Spasticity), 신체체력(Physical Fitness), 발란스(Balance: one leg stand), 상대적인 등속성 하지근력(Isokinetic Muscle Strength) 그리고 신체조성(Body Composition)로 하였다. 재활기간을 통해 처음 시작 일자에서 45일 간격으로 3차례의 측정을(1월 3일부터 4월 28일까지 실시하였다) 실시하였다. 최초 환자의 상태는 부분적으로 일상생활의 도움을 받아야 하는 상태로 동작을 시작하려 할 때 경직이 발생되어 옷을 입고 벗기, 신발 신고 벗기, 운전, 식사, 보행과 계단보행, 경사보행에서 보조자의 도움이 필요했으며, 작은 물건 잡기와 글씨쓰기, 타이핑 작업은 불가능 한 상태였다. 또한 스포츠 활동과 여가활동 역시 불가능 한 상태였다. 3달 15일간의 기간 동안 환자는 복학을 준비하기 위해 적극적으로 치료에 임했으며, 결과는 다음과 같았다. 신체조성은 재활 훈련을 통해 체중, 체지방율(%), 복부지방율(WHR)의 많은 감소를 가져왔다. 경직을 측정하는 Ashworth Scale은 정상에 가깝게 감소하였다. 관절가동범위는 고관절, 무릎, 발목에서 모두 증가하였다. 수동근력검사(0-9)는 많은 향상을 가져왔다. 신체체력능력 항목에서 근지구력의 윗몸일으키기와 팔굽히기, 악근력, 유연성으로 앉아 체간 숙이기, 민첩성으로 사이드 스텝, 순발력의 서전트는 모두 크게 향상되었다. 환자의 일상능력에서도 옷을 입고 벗기, 신발 신고 벗기, 운전, 식사, 보행과 계단보행, 경사보행에서 보조자의 도움이 필요없었으며, 타이핑 작업은 5손가락을 모두 사용하지는 않았지만, 1분에 80타로 큰 향상을 가져왔다. 또한 축구와 소프트볼, 등산을 달에 1회 정도 실시하여 약간의 도움만으로 가능하게 되었다.

  • PDF

Marginal and Internal Fit of Copings Made by CAD/CAM using Different Scanning Methods (서로 다른 스캔 방식을 이용하여 CAD/CAM에 의해 제작된 코핑의 변연 및 내면의 적합성)

  • Cho, Young Beom;Chae, Heon Chung;Kim, Hee Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.366-376
    • /
    • 2013
  • The purpose of this study is to evaluate the marginal and internal fit of coping made by CAD/CAM using different scanning methods. Zirconia coping was made by each CAD/CAM system followed by intra-oral scanning, model optical scanning and model contact scanning. It was embedded into Epoxy Resin and was cut by buccal to lingual. AMD (Absolute marginal discrepancy), MG (Marginal gap), GA (Gap of axial), GL (Gap of line angle) and GO (Gap of occlusal) of each sample were measured. The result is as followed; 1. The mean value of AMD in Group 1, Group 2, Group 3 are $141.21{\pm}42.94{\mu}m$, $140.63{\pm}31.64{\mu}m$, $109.37{\pm}28.42{\mu}m$. The averages of MG in Group 1, Group 2, Group 3 are $82.52{\pm}43.99{\mu}m$, $90.28{\pm}27.93{\mu}m$, $66.55{\pm}28.77{\mu}m$. Statistically there is no difference in AMD and MG among the three Groups (Anova, P>0.05). 2. GA of Group 2 revealed statistically difference compared with Group 1 and Group 3 (Anova, P<0.05). 3. GL and GO of Group 1 showed statistically significant differences compared with Group 2 and Group 3 (Mann-whitney test (P<0.05). Zirconia copings made by 3 ways of scanning methods have no difference with conventional ceramics in AMD and MG which are known as the most important factors.

Ultrasonographic Assessment of the Ulnar Collateral Ligament in High School Male Weight Lifters (고교 남자 역도 선수의 척측 측부인대 초음파 검사)

  • Jang, Il-Woong;Kim, Se-Sik;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.3 no.2
    • /
    • pp.47-53
    • /
    • 2010
  • Purpose: We evaluated the efficacy of ultrasonographic examination of the medial collateral ligament injury in elbow joints in the high school male weight lifting athletes. Materials and Methods: The study group (group I) included 15 male weight lifting athletes (average age: 16.8) and the control group (group II) was demographically matched 9 male with no symptoms on their elbow. Both elbow joint was evaluated through physical examination, plain radiograph, valgus stress view and ultrasonography. Results: On plain radiograph, there was no significant differences (3.6 mm, 2.7 mm; p>0.05) for the medial articular distances between both groups. The valgus stress view revealed the significant increase in group I (right, avr. 5.86 mm and 3.52 mm, p<0.01, left, avr. 5.33 mm and 3.64 mm, p<0.01). On ultrasonography, medial joint space was increased in group I (right, avr. 4.66 mm and 3.29 mm, p<0.01, left elbow 4.28 mm and 3.38 mm, p<0.01). The lateral shifting of proximal ulna also increased in group I (right, avr. 0.73 mm and 1.43 mm, p<0.01, left, avr. 0.96 mm and 1.53 mm, p<0.05). The angular deformity were more prevalent in group I. Conclusion: The medial joint space widening and angular deformity was prevalent in male weight lifting athletes. the ultrasonographic examination was useful in evaluating the degree and incidence of the medial collateral ligament injuries.

  • PDF

Initial Changes of Implant Stability from Installation during Early Bone Healing (임플란트 식립 후 초기 안정성의 변화)

  • Park, Chan-Jin;Kim, Dae-Gon;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.272-279
    • /
    • 2013
  • The concept of implant stability was basically originated from the relative condition of bone-implant interface and has some meanings for evaluation of that interface. In addtion, it has been used for the investigation of initial bone healing process after fixture installation because a degree of micromotion around interface can affect unfavorable clinical results. The purpose of this study is to investigate the mode of initial bone healing from fixture installation through prospective trial. Thirty fixtures were consecutively installed in mandibles of 26 patients with single tooth loss area and then healing abutment were secured for one-stage surgery meothod. Resonance frequency analysis was performed with one week interval during 12 weeks and periapical radiographs were taken at each month. Although marginal bone level change was not shown through observation period (P>0.05), statistical difference of implant stability was shown through 4 and 6 week (P<0.05) and was not shown after 6 week (P>0.05) according to the bone quality. Initial bone healing process is a successive process of bone resorption and favorable bone healing result might be postulated at 4 week interval after installation through RFA.

Concept and application of implant connection systems: Part II. Placement and restoration of external connection implant and tissue level implant (임플란트 연결부의 개념과 적용: Part 2. 안착형 외부 및 내부 연결형 임플란트의 식립과 보철)

  • Ko, Kyung-Ho;Kang, Hyeon-Goo;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.222-231
    • /
    • 2020
  • To use the external connection implant (EXT) appropriately, the inter-implant distance should be carefully considered during placement, and the bones raised above the implants should be trimmed during the second surgery. The hex abutment is more useful than the non-hex abutment. EXT is particularly useful when the inter-arch space is limited. The tissue level (TL, internal butt connection) implant has a biomechanical advantage of coronal wall thickness and a biological advantage of an inherent transmucosal smooth surface. During TL implant restoration, an abutment can be selected using the abutment and fixture margins with considerations for the inter-arch space. Since no single type of implant can satisfy all the cases, it is necessary to select the appropriate type, considering the occlusal force and the bone condition.

Effects of Cooling on Repeated Muscle Contractions and Tendon Structures in Human (냉각이 반복된 근수축과 사람의 건 구조에 미치는 영향)

  • Chae, Su-Dong;Jung, Myeong-Soo;Horii, Akira
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.6
    • /
    • pp.1-11
    • /
    • 2006
  • Purpose: This study compared the effects of non-cold and cold conditions on the viscoelastic properties of tendon structures in vivo. Methods: Seven male subjects perfomed plantar flesion exercise with maximal isokinetic voluntary contraction, which consisted of muscle contraction for 6 see and relaxation for 60 secs, 10 times for 1 set, Totally 10 sets were repeated. Before and after each task, the elongation of the tendon and aponeurosis of the medial gastrocnemius muscle (MG) was directly measured by ultrasonography. (The relationship between the estimated tendon force and tendon elongation.) Tendon cross-sectional area and ankle joint moment arm were obtained from magnetic resonance imaging (MRI). The tendon force was calculated from the joint moments and the tendon moment arm and stress was obtained by dividing force by cross-sectional areas (CSA). The strain was measured from the displacements normalized to tendon length. Results: After cooling, the tendon force was larger in cold than non-cold. The value of the tendon stiffness of MVC were significantly higher under the cold condition than under the non-cold condition. The maximal strain and stress of $7.4{\pm}0.7%$ and $36.4{\pm}1.8$ MPa in non-cold and $7.8{\pm}8.5%,\;31.8{\pm}1.1$ MPa in cold (P<0.05). Conclusion: This study shows for the first time that the muscle endurance in cooling increases the stiffness and Young's modulus of human tendons. The improvement in muscle endurance with cooling was directly related to muscle and tendon.

  • PDF

DEVELOPMENT OF THREE-DIMENSIONAL DYNAMIC ANALYSIS MODEL HIGH SPEED TRAIN-BRIDGE INTERACTION (철도 차량 - 교량 상호작용에 의한 3차원 동적 해석 모델 개발)

  • Dinh, Van Nguyen;Kim, Ki Du;Shim, Jae Soo;Choi, Eun Soo;Songsak, Suthasupradit
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.1
    • /
    • pp.151-163
    • /
    • 2008
  • A formulation of three-dimensional model of articulated train-b ridge dynamic interaction has been made for the Korean eXpress Train (KTX). Semi-periodic profiles of rail irregularities consisting of elevation, alignment, cross and gauge irregularities have also been proposed using FRA maximum tolerable rail deviations. The effects of rail joints and sleeper step were also included. The resulting system matrices of train and bridge are very spare, and thus, are stored in one-dimensional arrays, yielding a time-efficient solution. A numerical algorithm for computing bridge-train response including an iterative scheme is also formulated. A program simulating train-bridge interaction and solving this problem using the new algorithm is implemented as new modules for the f inite element analysis software named XFINAS. Computed results using the new program are then checked by that of the validated 2-D bridge-train interaction model. This new 3D analysis provides more detailed train responses such as swaying, bouncing, rolling, pitching and yawing accelerations, which are useful inevaluating passenger riding comfort. Train operation safety and derailment could also be directly investigated by relative wheel displacements computed from this program.

Effects of Participating in Tele-rehabilitation Service on Health Promotion and Quality of Life for Individuals with disability (원격재활서비스 참여가 지역사회 장애인의 건강증진 및 삶의 질에 미치는 영향)

  • Cha, Yerin;Jung, Bong-Keun;Lee, Seong A
    • 재활복지
    • /
    • v.22 no.3
    • /
    • pp.169-188
    • /
    • 2018
  • The aims of this study was to investigate the effect of the Tele-rehabilitation service on health promotion and quality of life for individuals with disability. The subjects were 3 men who agreed with participating in service and were assessed of health promotion level with physical/psychological scales and quality of life. The service consists of 20 sessions for 13 weeks. The results are as follows: First, all participants improved psychosocial health promotion (subjective health level) factor. Second, physical health promotion (upper limb function, strength, range of motion) maintained and improved, but there was little change. Third, the quality of life was higher than before. In addition, qualitative research showed that participants experienced a positive change in subjective health status, emotional stability, benefit, and self efficacy, and they were satisfied with the service. Based on the results, it was shown that participation helps improve the health and quality of life of the individuals with disability in the community. This study can be used it as a basic data for establishing a Tele-rehabilitation service for individuals with disability in local community.