• Title/Summary/Keyword: 공기분배시스템

Search Result 25, Processing Time 0.021 seconds

Design Review of Launch Complex Thermostatting System (발사대 온도 제어 시스템 설계 분석)

  • Choi, Sang-Ho;Ok, Ho-Nam;Kim, Seong-Lyong;Kim, Young-Hoon;Kim, In-Sun
    • Aerospace Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.57-67
    • /
    • 2012
  • In this study, design of LCTS(Launch Complex Thermostatting System), which is one of ground support equipments for KSLV-I, is analyzed based on CDP(Critical Design Package) provided by Russia. The thermo-hydraulic design of air preparation compartment and hydraulic design of air heating & distribution compartment performed. Also numerical simulation of air heating & distribution compartment was conducted and compared with actual measurement data. Finally, insulation design of system was analyzed. Designing method of LCTS will be helpful in developing or modifying LCTS for new launch vehicle.

Evaluation of Cooling Energy Saving through Applying Aisle Partition System on a Data Center Server Room (파티션 시스템 적용을 통한 기존 데이터센터 서버실의 냉방 에너지 절감 성능평가)

  • Park, Jong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.726-733
    • /
    • 2016
  • In this study, a computer simulation of the three types of air distribution systems, open type system, aisle partition system and aisle containment system, to evaluate the applicability of the aisle partition system on a data center server room. The variables of the simulation were the height and location of the partition fixed on the top server rack. The energy efficiency of the air distribution systems were confirmed to be excellent in the order of the aisle containment system, aisle partition system, and open type system. In the cold aisle partition system, the height of the partition that can be effective in saving cooling energy by obstructing sufficient air recirculation was found to be more than 0.9m. In the hot aisle partition system, the height of the partition was found to be more than 0.8m.

Numerical Analysis of Thermal Environment Control in High-Density Data Center (고밀도 데이터센터의 열환경제어를 위한 수치해석)

  • Kwon, Oh-Kyung;Kim, Hyeon-Joong;Cha, Dong-An
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.821-828
    • /
    • 2012
  • Increasing heat generation in CPUs can hamper effective recirculation and by-pass because of the large temperature difference between the exhaust and the intake air through a server room. This increases the overall temperature inside a data center and decreases the efficiency of the data center's cooling system. The purpose of the data center's cooling system is to separate the intake and exhaust air by controlling the computer room air-conditioner(CRAC). In this study, ICEPAK is used to conduct a numerical analysis of a data center's cooling system. The temperature distribution and the entire room are analyzed for different volumetric flow rates. The optimized volumetric flow rate is found for each CPU power. The heat removal and temperature distribution for CPU powers of 100, 120, and 140 W are found to be the best for a volumetric flow rate of $0.15m^3/s$. The numerical analysis is verified through RTI indicators, and the results appear to be the most reliable when the RTI value is 81.

A Method for Improving Air Distribution Performance at the Residence Ventilation System (주거 환기 시스템의 공기 분배 성능 개선 방안)

  • Park, Eun-Jun;Kim, Yong-Bong;Na, Hee-Hyoung;Lee, Sang-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.589-593
    • /
    • 2007
  • In the mechanical ventilation system, it is a fundamental condition to distribute the air equally to the each room. In this study, distribution performance of the air distributor which generally connected to a circular duct was investigated by simulation and experiment. In the first CFD analysis, maximum air flow rate deviation was an 63% in the air distributor model. After numbers of model modification and simulation, maximum flow rate deviation was reduced to 19% in the final simulation model. An air distributor which used in the experiment was produced by using data obtained from the final analysis. When experimental result was compared with analysis result, there was a deviation difference as much as 9%.

  • PDF

Computational Study on Design of the AIG for the Enhancement of Ammonia Injection in the SCR System (SCR 시스템 내 암모니아 분사 균일도 개선을 위한 AIG 설계에 관한 해석적 연구)

  • Seo, Moon-Hyeok;Chang, Hyuksang
    • Clean Technology
    • /
    • v.18 no.4
    • /
    • pp.410-418
    • /
    • 2012
  • The performance of the ammonia injection gun (AIG) used for maximizing the utilization of reducing agent in the selective catalytic reduction (SCR) system is decided by several parameters such as the pattern of flow distribution, geometry of the air distribution manifold (ADM) and the array and geometry of nozzles. In the study, the uniformity of jet flows from the nozzles in AIG was analyzed statistically by using the computational fluid dynamics (CFD) method to evaluate the role of design parameters on the performance of the SCR system. The uniformity of jet flows from the nozzles is being deteriorated with increasing the supplying flow rate to the AIG. Distribution rates to each branch pipe become lower with decreasing distance to the header, and flow rates from nozzle are also reduced with decreasing distance to the header. The uniformity of jet flows from nozzles becomes stable significantly when the ratio of summative area of nozzles to each sectional area of the branch pipe is below 0.5.

A Study on Air-distribution method for the Thermal Environmental Control in the Data Center (데이터센터의 합리적인 환경제어를 위한 공기분배 시스템에 대한 연구)

  • Cho, Jin-Kyun;Cha, Ji-Hyoung;Hong, Min-Ho;Yeon, Chang-Kun
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.487-492
    • /
    • 2008
  • The cooling of data centers has emerged as a significant challenge as the density of IT server increases. Server installations, along with the shrinking physical size of servers and storage systems, has resulted in high power density and high heat density. The introduction of high density enclosures into a data center creates the potential for "hot spots" within the room that the cooling system may not be able to address, since traditional designs assume relatively uniform cooling patterns within a data center. The cooling system for data center consists of a CRAC or CRAH unit and the associated air distribution system. It is the configuration of the distribution system that primarily distinguishes the different types of data center cooling systems, this is the main subject of this paper.

  • PDF

Development of Microprocessor-based Automatic Storage Controller and Temperature Auto-measurement System for Horticultural Crops (마이크로프로쎄서를 이용한 과채류 자동 저장 제어장치의 제작과 온도 자동계측 관리 시스템)

  • Park, Je-Kyun;Chun, Jae-Kun;Lee, Seung-Koo;Kim, Kong-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.845-849
    • /
    • 1988
  • A laboratory scale storage facility consisting of a cold room, sample jars and a ventilation device was designed and built. Storaging sample jars (1.7 l) for fruit were fabricated with transparent acryl and provided with a constant air flow. For the supplying of air to sample jars, the air distributing system was built with solenoid valves, an air precooling coil and a pressure equalizing tank. To provide the programmable storaging environment of the facility a microprocessor-based controller was designed and installed. The controller was built with the 8 bit microprocessor (Z-80), EPROM, RAM, programmable peripheral interface(8255 PPI), and A/D converter. Softwares for the auto-temperature measurement and control of the storage system were developed and systemized in ROM. The automated storage system was applied to citrus storage, and the temperature of the storage facilities was successfully acquisited to the computer and controlled.

  • PDF

A Study on the Liquid-level Sensors Using Splitting Ratio of Fiber-optic Directional Couplers (광섬유형 방향성 결합기의 광 분배비를 이용한 수위 센서 연구)

  • Sohn, Kyung-Rak;Key, Kwang-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.846-851
    • /
    • 2010
  • A liquid-air interface sensing system using the flat end surfaces of a fused-silica fiber coupler has been demonstrated. The principle is based on the additional optical loss caused by changing the refractive index of the external material at the boundary of the end face made of a fiber. The immersion characteristics of this system with respect to the different splitting ratios of the couplers were investigated to determine the sensitivity when it responses to water and air. These experimental data are very useful for selecting the coupling ratio of a coupler in order to develop a multiple sensing probe system. In the proposed sensor structure, it can be emphasize that the sensing probe can be appropriately arrayed on the basis of splitting ratio of the coupler. As a result, it is expected that the proposed liquid-air interface sensors can also be applied to monitor flooding that occurs in multiple areas at the same time.

Performance Evaluation of Multidrop Chamber Ventilation System in Apartment (공동주택내 다분기챔버형 환기시스템 적용을 통한 풍량분배 개선효과에 관한 연구)

  • Kim, Sung-Soo;Son, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.10
    • /
    • pp.545-552
    • /
    • 2009
  • It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. And TAB process is applied to control the designed air volume with adjusting volume dampers and/or supply diffusers after fully installing the ventilation system. This process has been resulted increasing the initial cost for the residential ventilation system because of man-hour and accessories such as volume control damper or diffuser. However it is difficult to adjust the air volume adequately in small air duct branches in residential ventilation system. The purpose of this study is to figure out the performance of Multidrop chamber coupling system for the residential ventilation system.

Experiments on the Characteristic of Storage Tank in In-Water Harvest-Type Ice Storage System (수중 하베스트형 빙축열시스템의 축열조 특성 실험)

  • 최인수;김재돌;윤정인
    • Journal of Energy Engineering
    • /
    • v.9 no.4
    • /
    • pp.366-371
    • /
    • 2000
  • 본 연구는 동적형 빙축열시스템에 있어서 증발판이 축열조 상부에 설치되어 생성된 얼음을 주기적으로 분리, 이탈시켜 하부에 설치된 축열조에 저장하는 기존의 하베스트형 빙축열시스템과는 반대로 축열조 내에 증발판을 설치하여 수중에서 얼음을 생성시키고 분리시켜 부럭에 의해 얼음을 띄워 저장하는 새로운 방식의 수중 하베스트형 빙축열시스템 개발에 관한 연구이다. 본 방식은 축열조 내에 증발판이 설치되어 제빙과 탈빙이 이루어짐으로서 기존 시스템에 설치되는 순환펌프나 순환수 분배기 및 배관 등의 설비가 불필요하고, 또한 조내 물과 증발판이 직접접촉에 의해 열교환이 이루어지므로 기존 공기 중에서의 열교환 방식보다 전열효율이 우수한 장점을 가지고 있다. 따라서 본 연구에서는 상기의 수중 빙제조 방식에있어 빙 제조시와 방냉시 축열조의 열특성을 실험적으로 밝혀 시스템 최적화 및 성능 향상에 대한 기초 자료를 제공하고자 하였다.

  • PDF