Browse > Article

Performance Evaluation of Multidrop Chamber Ventilation System in Apartment  

Kim, Sung-Soo (Department of Architecture, Hanyang University)
Son, Jang-Yeul (Department of Architecture, Hanyang University)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.21, no.10, 2009 , pp. 545-552 More about this Journal
Abstract
It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. And TAB process is applied to control the designed air volume with adjusting volume dampers and/or supply diffusers after fully installing the ventilation system. This process has been resulted increasing the initial cost for the residential ventilation system because of man-hour and accessories such as volume control damper or diffuser. However it is difficult to adjust the air volume adequately in small air duct branches in residential ventilation system. The purpose of this study is to figure out the performance of Multidrop chamber coupling system for the residential ventilation system.
Keywords
Apartment; Multidrop chamber; Air distribution; Ventilation rate; Pressure loss;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Lee, D. W., Park, Y. W. and Park, M. S., 1998, Balancing air flow at terminal in CAV duct system with DPM method, SAREK, Vol. 10, No. 1, pp. 66-78
2 Yee, J. J., Choi, S. Y., Kim, S. K., Kim, K. H., Lee, Y. W. and Kim, H. Y., 2007, A Study on Application of Distributor for Duct Design at House Ventilation System, SAREK, Vol. 19, pp. 770-775
3 Park, Y. W., Park, M. S. and Lee, D. W., 1995, A Numerical Study for Balancing CAV Duct System, Proceeding of Architectural Institute of Korea, Vol. 15, No. 2, pp. 333-336
4 Song, J. W., Kang, I. K., Kim, S. S., Won, C. H. and Kim, G. O., 2004, Measurements of Flow Resistance in AD to Develope Heat Recovery Ventilator for Highrise Apartment Complex, SAREK 2008 Summer Annual Conference, pp. 362-367
5 Yoon, D. W. and Yang, S. B., 2009 An, Evaluation on the Performance of Air Distributor with Split Guide Vaneand EVA Flexible Duct in Residential Ventilation System, Journal of Architectural Institute of Korea, Vol. 25, No. 7, pp. 350-312
6 Yang, S. B., Yoon, D. W., Hong, S. M., Kim, J. H., Lee, J. Y. and Lee, S. C., 2008, An Evaluation on the Performance of Air Distributor with Split Guide Vane and its Proper Installation in Residential Ventilation System, Proceeding of the KIAEBS 2008 Autumn Annual Conference
7 Kim, S. S., Son, J. Y., Kim, T. J., Kim, H. J. and Pack, J. S., 2008, Performance Evaluation of Multidrop Chamber Ventilation System in Apartment, Proceeding of the KAIEBS 2008 Autumn Annual Conference, pp. 149-153
8 Choi, J. H., Ju, S. Y. and Yee, J. J., 2007, A Study on Application of Distributor for Duct Design at House Ventilation System, Proceeding of SAREK, pp. 1037-1043
9 Go, S. H., Lee, H. J. and Park, J. C., 2004, An Experimental study of Ventilation Effectiveness according to Duct Layouts in Apartment Units, SAREK 2008 Winter Annual Conference, pp. 156-159