• Title/Summary/Keyword: 공급장치

Search Result 1,859, Processing Time 0.034 seconds

Isolation Control High Speed Transfer Switch for Upgrade Reliability of Uninterruptible Power Supply (USP의 신뢰성 향상을 위한 독립제어 고속절환장치)

  • Jung, Hyun-Chul;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.278-286
    • /
    • 2008
  • This paper investigates the fault generation type and the cause of output interruptionsin bulky with $30^{\sim}500[KVA]$ double conversion UPS, and proposes the fault detection method to improve the reliability of power supply used in the critical load in industry. Identifies its existing way of detecting a quality of inverter output it to bypass when exceeds its expectation. Under a UPS managing system, when an inner (Power device, Controller, CPU) fault occurs it disrupts the power supply and these occurrences has been verified by the results of experiments and application results. To overcome these problems, the proposed method constructs independently a fault-detection, a bypass-control device and a triple power supply apart from the conventional UPS operation. Also the detection point is changed to the preceding of a circuit breaker, a reference of fault detection is modified to avoid any clash and the breaking equipment is attached to intercept a spread of accident. As a result of applications of these developed systems to 242 UPS which was installed purposefully to the communication power supply, the service errors has not occurred in the UPS for two years since 2006.

법령과 고시-도시가스사업법시행규칙 개정

  • Korea Mechanical Construction Contractors Association
    • 월간 기계설비
    • /
    • no.1 s.198
    • /
    • pp.49-64
    • /
    • 2007
  • 도시가스사업법 시행규칙이 일부 개정되어 지난 해 12월 4일 공포되었다. 도시가스 배관 중 수요자에게 공급하기 위한 저압의 인입관(引入管) 공사 및 단순연결 공사 등 짧은 구간의 배관공사는 상주시공감리에서 제외하여 신속한 가스공급이 이루어지도록 하는 한편, 상주시공감리는 전공정(全公定)시공감리로, 일반시공감리는 일부공정시공감리로 용어를 정비하여 그 의미를 명확히 하고, 가스사용자의 토지 안에 공급관의 가스차단장치를 설치할 수 있도록 하되, 그 가스차단장치의 설치 및 유지관리 비용은 공급자의 부담으로 하는 등 현행 제도의 운영상 나타난 일부 미비점을 개선·보완하려는 것이다.

  • PDF

A study on the variable power supplies of 100W class for spine health management device (척추 건강관리기용 100W급 가변형 전원장치에 관한 연구)

  • Shin, Duck-Shick;Lee, Sang-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.203-204
    • /
    • 2015
  • 본 논문은 척추 건강관리기의 구동을 위한 가변형 전원 공급장치에 관한 논문이다. 본 시스템은 의료용 및 척추 마사지를 위한 장비로서 인체에 접촉하는 경우가 많고 높은 안전성을 요구하기 때문에 안정적인 전원 공급이 필요한 시스템이다. 본 시스템을 구동하기 위해서 100W의 전원이 필요하여 비교적 간단하고 절연타입의 Forward Type의 토폴로지를 적용하여 시스템에서 요구하는 전원을 공급하도록 회로를 설계 하였으며, 이를 시스템에 적용하여 성능을 검증하였다.

  • PDF

저궤도 위성 전원선 확인 시험

  • Yun, Yeong-Su;Won, Yeong-Jin;Kim, Jin-Hui
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.185.2-185.2
    • /
    • 2012
  • 저궤도 위성 비행모델 기능시험은 위성체 내부 전장품들 간의 접속 확인과 조립 및 연결상태를 확인하는 시험을 우선적으로 수행한다. 위성체의 전원선 확인 시험은 전기 전자적 조립 시험에서 가장 처음으로 수행하는 시험이다. 전력조절분배장치로부터 전장품 각각의 하드웨어로 공급되는 50볼트 주전원 또는 28볼트 부전원이 정상적으로 공급하게 되는지를 검증한다. 위성체 하니스가 설치된 후, 각각의 하드웨어에 공급되는 전원의 극성 및 연속성 시험을 수행한다. 전력조절분배장치는 태양전지판으로부터 얻어진 전력이 레귤레이터에 의해 정류된 전압을 받아 릴레이나 FET를 통하여 모든 전장품에 전원을 공급하는 주요 장비이다. 전력조절분배장치 내부나 외부 하니스 오류로부터 생길 수 있는 잘못 리드된 전원으로부터 전장품을 보호하기 위하여 하니스를 하드웨어에 연결하기 전에 우선적으로 전원선 확인 시험을 수행한다. 위성체 전원선 확인 시험은 위성체와 기능시험장비를 연결하여 시리얼 명령어를 통해 전력조절분배장치 내부의 FET 동작을 조절하며, FET 동작 상태 및 전장품에 접속되는 입력 단에서의 전압 및 전원 특성 등을 점검한다. 위성체의 주전원 50볼트 라인의 연결도 확인과 부전원 28볼트 라인의 연결도 확인 및 전력제어 유닛 내부 FET의 기능 확인을 수행하며 또한, 전력제어부 외부에 공급하는 28볼트 펄스와 15볼트 펄스를 측정 검증하는 시험을 수행한다.

  • PDF

Design and Analysis of Test Facility for the Experiment of Transpiration Cooling in Hot-flow Condition (고온유동 조건의 분출냉각 실험을 위한 시험장치의 설계 및 해석)

  • Lee, Jungmin;Na, Jaejeong;Kang, Kyoungtaik;Kwon, Minchan;Hwang, Kiyoung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.2
    • /
    • pp.46-56
    • /
    • 2013
  • The test facility with hot-air supply system is required to develop transpiration cooling materials and experimentally evaluate its performance. In the study, the facility consists of an arc-plasma generator, plenum chamber suppling cold air, and test section was designed and an internal flow analysis was executed. From CFD results, it was confirmed that the designed plenum chamber thermally safeties and ideally mixes with plasma gas and cold air in the chamber. In addition, validity of design for supplying homogeneous flow to the test section was confirmed by this analysis.

Ozone Generating Power Supply with High Power Factor (고역률 오존발생기 전원공급장치 연구)

  • An, Hyunsung;Shin, Changhoon;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.169-170
    • /
    • 2014
  • 본 논문에서는 높은 역률을 가지는 PFC(Power Factor Correction) 컨버터와 높은 고주파 전압을 발생시키는 단상 하프브리지 인버터를 채용한 오존발생기를 소개한다. PFC 컨버터를 채용하여 기존의 오존발생기용 전원장치에 비해 입력 역률, 전원공급체계와 보호 장치를 개선하였으며, 3kW급의 프로토타입을 구현하고 시뮬레이션 및 실험을 통하여 전원장치의 안정성 및 입력에 대한 높은 역률(0.99이상)을 확인하였다.

  • PDF

Current Control of 12-pulse Dual Converter for High Current Coil Power Supply (대전류 코일 전원 공급장치를 위한 12펄스 듀얼 컨버터의 전류제어)

  • 송승호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.332-338
    • /
    • 2002
  • High current coil power supply for superconductivity coil of tokamak requires fast dynamics performance of di/dt and smooth change over of current direction. To meet the specification high performance DSP-based controller Is designed for 12-pulse thyristor dual converter with interphase transformer(IPT). Not only the total current of Y and $\Delta$ converter units but also the difference for those should be regulated fast and accurately. Proportional and integral controller is designed for current difference control and the controller output is compensated to $\Delta$ converter. The source voltage phase angle detection and gate pulse generation algorithm are implemented in software for higher reliability of current control. The current error Is reduced by selection of appropriate initial gating angle during the transient of change over of current direction between thyristor converters.

A Study on the Contactless Power Supply System for Stokcer System (Stocker 시스템에 적용한 비접촉 전원장치에 관한 연구)

  • Hwang, Gye-Ho;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.148-156
    • /
    • 2007
  • This paper explains stocker system that is operated in the long distance and linear area. The power system of stocker system uses Contactless Power Supply(CPS) to reduce problems of particle generation. The circuit configuration of CPS is simplified than the conventional ones, and the prototype is designed for commercial product. To transfer output data(information) from crane(secondary vehicle system) of the CPS to Primary system optical modem and TMS320F243(DSP, TI) are used between primary and secondary. power system are used, and the output voltage is controlled by operating frequency modulation. This paper is applied to stocker system controlled as one to one communication between the moving part(secondary system) and fixed part(primary system) of crane using optical modem. The study makes one to multi communication between fixed part and moving part for the purpose of multi crane operation of stocker system and must be done in the future.

Development of Xenon Feed System for a Hall-Effect Thruster to Space-propulsion Applications (우주추진용 홀방식의 전기추력기를 위한 제논연료공급장치 개발)

  • Kim, Youn-Ho;Kang, Seong-Min;Jung, Yun-Hwang;Seon, Jong-Ho;Wee, Jung-Hyun;Yoon, Ho-Sung;Choe, Won-Ho;Lee, Jong-Sub;Seo, Mi-Hui
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.1
    • /
    • pp.84-89
    • /
    • 2011
  • A Xenon Feed System (XFS) has been developed for hall-effect thruster to small satellite space-propulsion system applications. The XFS delivers low pressure gas to the Anode and Cathode of thruster head unit from a xenon storage tank. Accurate throttling of the propellant mass flow rate is independently required for each channel of the thruster head unit. The mass flow rate to each channel is controlled using the accumulator tank pressure regulation through a micron orifice and isolation valve. This paper discusses the Xenon Feed System design including the component selections, performance estimation and functional test.

Development of Bioreactors for Enrichment of Chemolithotrophic Methanogen and Methane Production (독립영양형 메탄생산세균의 농화 및 메탄생산 반응기의 개발)

  • Na, Byung-Kwan;Hwang, Tae-Sik;Lee, Sung-Hun;Ju, Dong-Hun;Sang, Byung-In;Park, Doo-Hyun
    • Microbiology and Biotechnology Letters
    • /
    • v.35 no.1
    • /
    • pp.52-57
    • /
    • 2007
  • A gas-circulating bioreactor was used for enrichment of autotrophic methanogens. Mixture of hydrogen and carbon dioxide (5:1) was used as a sole energy and carbon source. Anaerobic digestive sludge isolated from wastewater treatment system was inoculated into the gas-circulating bioreactor. The enrichment of two chemolithotrophic methanogens, Methanobacterium curvum and Methanobacterium oryzae was accomplished in the gas-circulating bioreactor. The enriched bacteria were cultivated in a bioreactor equipped with hollow-fiber hydrogen-supplying system (hollow-fiber bioreactor), and a hybrid-type bioreactor equipped with hollow-fiber hydrogen-supplying system and electrochemical redox control system. The methane productivity was maximally 30% (V/V) in the hollow-fiber bioreactors and 50% (V/V) in the hybrid-type bioreactor.