• Title/Summary/Keyword: 골주사

Search Result 178, Processing Time 0.025 seconds

The Efficacy of Intra-Articular Hyaluronic Acid Injections in Ankle Osteoarthritis (족관절 골관절염에서의 관절 내 Hyaluronic Acid 주사의 유용성)

  • Park, Chul Hyun;Park, Jeong Jin;Seok, Hyun Gyu;Woo, In Ha
    • Journal of Korean Foot and Ankle Society
    • /
    • v.26 no.2
    • /
    • pp.71-77
    • /
    • 2022
  • Purpose: This study sought to investigate the appropriate indications for intra-articular injection of hyaluronic acid in ankle osteoarthritis, its efficacy at each stage of osteoarthritis and to compare the efficacy related differences at each stage. Materials and Methods: A retrospective study was conducted from January 2016 to September 2019 on 43 patients (50 cases) diagnosed with ankle arthritis and given intra-articular injection of hyaluronic acid. Patients were classified according to the modified Takakura ankle osteoarthritis stages. Stage 2 comprised 24 cases; stage 3A, 15 cases; stage 3B, 8 cases; and stage 4, 3 cases. The clinical evaluation was carried out using the visual analogue scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS) score, and the Foot and Ankle Outcome Score (FAOS). The patients' satisfaction with the injection was evaluated at 1 year after injection. A radiographic evaluation was performed to gauge the progression of osteoarthritis before and after the injection. Results: The VAS, AOFAS score, and FAOS at 3 months and 1 year after injection showed statistically significant improvements compared to those before the injection. There was a significant difference in the VAS for each stage over time; however, this was not the case with the AOFAS score and the FAOS. A significant improvement of the VAS after injection was seen only in stage 3A when compared with the other stages. The overall satisfaction rate with the injection was 90%. There were no ankle osteoarthritic stage changes in the serial follow-up radiograph. Conclusion: Intra-articular injection of hyaluronic acid resulted in a significant clinical improvement up to 1 year after the injection. Therefore, the intra-articular injection of hyaluronic acid could be a treatment option for ankle osteoarthritis.

Biological Activities of Calcium Polyphosphate (Calcium polyphosphate의 생물학적 활성도에 관한 연구)

  • Seol, Yang-Jo;Lee, Jae-Il;Lee, Yong-Moo;Lim, Yoon-Tak;Kim, Seok-Young;Ku, Young;Rhyu, In-Chul;Hahm, Byung-Do;Han, Soo-Boo;Choi, Sang-Mook;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.213-231
    • /
    • 2000
  • 이 연구의 목적은 다공성의 CPP 내부에 쥐의 장골의 골수에서 유래된 세포를 접종하고 3차 원적으로 배양하여 CPP가 골 형성을 위한 조직공학의 지지체로 적용가능한가를 연구하는 것과 Calcium PolyPhosphate(CPP)의 돌연변이 유발성을 검사하는 것이다. 무수 ($Ca(H_2PO_4)$)를 condensation하여 무결정의 ($Ca(PO_3)$)를 얻고 이를 용융하고 냉각시킨 후 분쇄하여 Calcium polyphosphate(CPP) powder를 얻었다. 다공성의 CPP는 5% $SiO_2$를 첨가하여 sponge 형태로 $450-550{\mu}m$ 소공의 크기를 가지는 것과(CPP-45ppi) $200-300{\mu}m$의 소공의 크기를 가지는 것(CCP-60ppi) 2가지로 제작하였다. 각각의 CPP matrices는 $5mm{\times}5mm{\times}1mm$의 블록 형태로 만들었다. 체중 100g 내외의 백서에서 장골(femur, tibia)을 채취하여 백서의 장골 골수 세포를 분리하여 배양한 후 24well에 CPP block을 넣고 CPP block 당 $10^5$개의 배양한 세포를 접종하였다. 배양 1, 7, 14, 및 21 일째에 각 well에서 trypsin EDTA를 이용하여 2회 반복하여 cell을 분리하였고, 원심분리한 후 hemacytometer로 측정하였다. 또, 45ppi와 60ppi, 그 리 고 Tissue Culture Polystyrene(control group)에 접종, 배양된 세포들의 염기성 인산분해효소활성도를 배양 7, 14, 및 21 일째에 각각 측정하였다. 각 기간별로 배양된 세포-CPP 혼합체내에서 세포의 부착 및 증식과 형성된 조직의 3차원적 형태를 관찰하기 위하여 주사전자현미경하에서의 관찰하였다. CPP의 돌연변이 유발성 검사 (mutagenicity test)를 위해 hypoxanthine-guanine phosphoribosyl transferase(HPRT) assay를 하였다. NIH3T3 cell line과 CHO-K1 cell line으로 각각 $1000{\mu}g/m{\ell}$, $100{\mu}g/m{\ell}$, $10{\mu}g/m{\ell}$ 그리고 $1{\mu}g/m{\ell}$의 CPP 농도에서 측정하였다. 통계적 분석을 위해서 모든 측정은 각군당 4개체 이상 시험하였고, 각 측정값은 평균값${\pm}$표준편차로 나타내었다. 각 군간의 통계적 유의성 검정을 위해서 Analysis of variance(ANOVA)를 이용하였고 Tukey의 방법으로 사후분석을 실시하였다. 제작된 CPP matrices 소공들이 서로간에 연결이 잘 되어있는 형태였다. 두 가지로 제조된 CPP(45ppi와 60ppi) 모두에서 세포의 부착이 잘 일어났고, 부착된 세포의 분열도 잘 일어났다. 2 가지의 CPP 모두에서 7, 14, 21일째의 세포 수는 1일째에 비해 유의성 있게 증가하였다(P<0.01). 3차원적 구조인 Calcium PolyPhosphate에서 배양한 세포는 24well dish(tissue culture polystyrene)에서 평면적으로 배양한 대조군의 세포에서 보다 염기성 인산분해효소 (Alkaline Phosphatase)를 유의성 있게 높게 나타냈다. 주사전자현미경에서 세포-CPP 혼합체를 관찰한 결과, CPP block에 세포들이 잘부착되어 있었고, 시간이 지남에 따라 세포가 여러 층을 형성하면서 뭉치는 현상을 보였다. 또, HPRT assay 결과 , Calcium PolyPhosphate는 돌연변이 유발성을 보이지 않았다. 이상의 결과로 볼 때 CPP에는 세포부착이 잘 일어나고, 지지체 상에서 세포의 분열도 활발하게 일어나므로 골조직을 위한 조직공학의 우수한 지지체가 될 수 있을 것으로 사료된다.

  • PDF

Verification of Radiation Therapy Planning Dose Based on Electron Density Correction of CT Number: XiO Experiments (컴퓨터영상의 전자밀도보정에 근거한 치료선량확인: XiO 실험)

  • Choi Tae-Jin;Kim Jin-Hee;Kim Ok-Bae
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.105-113
    • /
    • 2006
  • This study peformed to confirm the corrected dose In different electron density materials using the superposition/FFT convolution method in radiotherapy Planning system. The experiments of the $K_2HPO_4$ diluted solution for bone substitute, Cork for lung and n-Glucose for soft tissue are very close to effective atomic number of tissue materials. The image data acquisited from the 110 KVp and 130 KVp CT scanner (Siemes, Singo emotions). The electron density was derived from the CT number (H) and adapted to planning system (Xio, CMS) for heterogeneity correction. The heterogeneity tissue phantom used for measurement dose comparison to that of delivered computer planning system. In the results, this investigations showed the CT number is highly affected in photoelectric effect in high Z materials. The electron density in a given energy spectrum showed the relation of first order as a function of H in soft tissue and bone materials, respectively. In our experiments, the ratio of electron density as a function of H was obtained the 0.001026H+1.00 in soft tissue and 0.000304H+1.07 for bone at 130 KVp spectrum and showed 0.000274H+1.10 for bone tissue in low 110 KVp. This experiments of electron density calibrations from CT number used to decide depth and length of photon transportation. The Computed superposition and FFT convolution dose showed very close to measurements within 1.0% discrepancy in homogeneous phantom for 6 and 15 MV X rays, but it showed -5.0% large discrepancy in FFT convolution for bone tissue correction of 6 MV X rays. In this experiments, the evaluated doses showed acceptable discrepancy within -1.2% of average for lung and -2.9% for bone equivalent materials with superposition method in 6 MV X rays. However the FFT convolution method showed more a large discrepancy than superposition in the low electron density medium in 6 and 15 MV X rays. As the CT number depends on energy spectrum of X rays, it should be confirm gradient of function of CT number-electron density regularly.

  • PDF

Effect of Implant Types and Bone Resorption on the Fatigue Life and Fracture Characteristics of Dental Implants (임플란트 형태와 골흡수가 임플란트 피로 수명 및 파절 특성에 미치는 효과에 관한 연구)

  • Won, Ho-Yeon;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.121-143
    • /
    • 2010
  • To investigate the effect of implant types and bone resorption on the fracture characteristics. 4 types of Osstem$^{(R)}$Implant were chosen and classified into external parallel, internal parallel, external taper, internal taper groups. Finite elements analysis was conducted with ANSYS Multi Physics software. Fatigue fracture test was performed by connecting the mold to the dynamic load fatigue testing machine with maximum load of 600N and minimum load of 60N. The entire fatigue test was performed with frequency of 14Hz and fractured specimens were observed with Hitachi S-3000 H scanning electron microscope. The results were as follows: 1. In the fatigue test of 2 mm exposed implants group, Tapered type and external connected type had higher fatigue life. 2. In the fatigue test of 4 mm exposed implants group, Parallel type and external connected types had higher fatigue life. 3. The fracture patterns of all 4 mm exposed implant system appeared transversely near the dead space of the fixture. With a exposing level of 2 mm, all internally connected implant systems were fractured transversely at the platform of fixture facing the abutment. but externally connected ones were fractured at the fillet of abutment body and hexa of fixture or near the dead space of the fixture. 4. Many fatigue striations were observed near the crack initiation and propagation sites. The cleavage with facet or dimple fractures appeared at the final fracture sites. 5. Effective stress of buccal site with compressive stress is higher than that of lingual site with tensile stress, and effective stress acting on the fixture is higher than that of the abutment screw. Also, maximum effective stress acting on the parallel type fixtures is higher. It is careful to use the internal type implant system in posterior area.

Fatigue fracture of different dental implant system under cyclic loading (반복하중에 따른 수종 임플란트의 피로파절에 관한 연구)

  • Park, Won-Ju;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.424-434
    • /
    • 2009
  • Statement of problem: Problems such as loosening and fractures of retained screws and fracture of implant fixture have been frequently reported in implant prosthesis. Purpose: Implant has weak mechanical properties against lateral loading compared to vertical occlusal loading, and therefore, stress analysis of implant fixture depending on its material and geometric features is needed. Material and methods: Total 28 of external hexed implants were divided into 7 of 4 groups; Group A (3i, FULL $OSSEOTITE^{(R)}$Implant), Group B (Nobelbiocare, $Br{\aa}nemark$ $System^{(R)}$Mk III Groovy RP), Group C (Neobiotec, $SinusQuick^{TM}$ EB), Group D (Osstem, US-II). The type III gold alloy prostheses were fabricated using adequate UCLA gold abutments. Fixture, abutment screw, and abutment were connected and cross-sectioned vertically. Hardness test was conducted using MXT-$\alpha$. For fatigue fracture test, with MTS 810, the specimens were loaded to the extent of 60-600 N until fracture occurred. The fracture pattern of abutment screw and fixture was observed under scanning electron microscope. A comparative study of stress distribution and fracture area of abutment screw and fixture was carried out through finite element analysis Results: 1. In Vicker's hardness test of abutment screw, the highest value was measured in group A and lowest value was measured in group D. 2. In all implant groups, implant fixture fractures occurred mainly at the 3-4th fixture thread valley where tensile stress was concentrated. When the fatigue life was compared, significant difference was found between the group A, B, C and D (P<.05). 3. The fracture patterns of group B and group D showed complex failure type, a fracture behavior including transverse and longitudinal failure patterns in both fixture and abutment screw. In Group A and C, however, the transverse failure of fixture was only observed. 4. The finite element analysis infers that a fatigue crack started at the fixture surface. Conclusion: The maximum tensile stress was found in the implant fixture at the level of cortical bone. The fatigue fracture occurred when the dead space of implant fixture coincides with jig surface where the maximum tensile stress was generated. To increase implant durability, prevention of surrounding bone resorption is important. However, if the bone resorption progresses to the level of dead space, the frequency of implant fracture would increase. Thus, proper management is needed.

Analysis of Bone Marrow Micrometastasis Using RT-PCR in Patients with Small Cell Lung Carcinoma (소세포 폐암에서 역전사 중합효소 연쇄반응(RT-PCR)을 이용한 골수 미세전이(naicronaetastasis)의 분석)

  • Kim, Tae-You;Park, Jong-Kook;Ryoo, Baek-Ryeol;Im, Yung-Hyuck;Kang, Yoon-Koo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.6
    • /
    • pp.797-806
    • /
    • 1999
  • Background: About 20% of small cell lung cancer(SCLC) patients have bone marrow(EM) metastasis at the time of diagnosis and the remaining patients are also considered with micrometastasis. In an attempt to detect EM micrometastasis, we used cytokeratin(CK)-20 as a molecular marker, which is specific for epithelial cells. Method: A sensitive RT-PCR assay was used to compare CK-20 expression both in SCLC cell line H209 and normal leukocyte and to evaluate EM aspirates of 28 SCLC patients. Result: H209 cell line showed CK-20 expression but normal leukocyte did not, suggesting CK-20 expression is lung tissue-specific. Of 28 patients(11 limited disease, 17 extensive disease), only 2(1/11, 1/17) samples tested revealed positive signal for CK-20. Two patients with CK-20 expression had EM metastasis or multiple bone involvement during follow-up. Conclusion: Although circulating tumor cells were detected in EM of small portion of patients with bone metastasis, CK-20 doesn't seem to be a reliable marker for the detection of micrometastasis in SCLC. This study emphasizes that identification of more specific marker for micrometastsis is mandatory prior to clinical application.

  • PDF

$^{99m}Tc-MDP$ Bone Scan Findings in Various Clinical Stages of Malignancies (악성종양의 임상적 병기에 따른 $^{99m}Tc-MDP$ 골주사의 비교관찰)

  • Yoon, Hwi-Joong;Lee, Myung-Chul;Cho, Bo-Yeon;Kim, Noe-Kyeong;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.15 no.2
    • /
    • pp.1-9
    • /
    • 1981
  • Bone scans with $^{99m}Tc-MDP$ (methylene diphosphonate) were obtained and analysed in 574 patients with biopsy-proven malignancy, who visited Seoul National University Hospital from April, 1979 to June, 1931. Clinical staging was done in all patients without bone scan information and compared with bone scan to determine the predictive value of bone scanning. 1. Primary site of the maligancies were lung in 152, breast in 97, stomach in 43, colon in 15, esophagus in 9, liver and pancreas in 11, kidney in 14, bladder in 27, prostate in 22, thyroid in 20, skin in 11, bone in 9, head and neck in 36, ovary and uterus in 17, hematopoietic and lymphoretic ular system in 33, nervous system in 10, and others in 9 cases. Primary site was not defined in 39 cases. 2. Bone scans were positive in 186 cases (32.4%), which, included 48 cases (31.6%) of lung cancer, 27 cases (27.8%) of breast cancer, 12 cases(28%) of stomach cancer, 6 cases(40%) of colon cancer, 6 cases(43%) of kidney tumor, 4 cases(15%) of bladder cancer, 14 cases(64%) of prostate cancer, 3 cases(15%) of thyroid cancer and 66 other cases. 3. Bone scans were suspicious in 64 cases (11.2%) which included 29 cases (19.1%) of lung cancer, 10 cases (10.3%) of breast cancer, 4 cases (9.3%) of stomach cancer, one case (7%) of colon cancer, 3 cases(11%) of bladder cancer, 2 cases(10%) of thyroid cancer and 15 other cases. 4. Out of 121 cases with early stage of malignancy (which included 20 cases of lung cancer in stage I, II, 38 cases of breast cancer, 13 cases of stomach cancer, 8 cases of kidney tumor, 14 cases of thyroid cancer in stage $I{\sim}III$, and 6 cases of colon cancer, 14 cases of bladder cancer, 8 cases of prostate cancer in stage $A{\sim}C$, bone scans were positive in 5 cases (4.1%) which included 3 cases of lung cancer one case of breast cancer and one case of prostate cancer, and considered as further advanced stage. Out of 121 cases with early stage of malgnancy, bone scans were suspicious in 21 cases (17.4%) which inlcuded 9 cases of lung cancer, 4 cases of breast cancer, 2 cases of stomach cancer, one case of colon cancer, 3 cases of bladder cancer, and 2 cases of thyroid cancer. From these results, we concluded bone scan was useful in detecting bone metastasis in patients of early stage of malignancy, determining prognosis and establishing therapentic plan.

  • PDF

Arthroscopic Excision of Accessory Bone in the Ankle Joint (족관절 부골의 관절경을 이용한 절제술)

  • Choi, Chong-Hyuk;Chung, Jae-Bong;Choi, Woo-Jin;Kim, Hyoung-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.201-205
    • /
    • 2005
  • Purpose: The purpose of this study is to evaluate the result of arthroscopic excision of painful Os subtibiale and Os subfibulare. Materials and Methods: Sixteen patients who had accessory bone in the ankle joint were treated by arthroscopy. Os subtibiale was four cases and os subfibulare twelve. The average follow-up period was 9 months$(range:6{\sim}42months)$. All patients were evaluated clinically with physical examination and radiologically with simple X-ray and for further evaluation, eight with bone scan, three with computed tomography and twelve with magnetic resonance image. We estimated the result of resection with Ogilvie-Harris's criteria. Results: All parameters of subjective and functional evaluation were improved with statistical significance(p<0.05). At final evaluation, eight patients still complained of mild pain and among them, three patients for synovitis, three for tendinitis on MRI and two for incomplete resection. Conclusion: The arthroscopic resection is a very effective method for painful os subtibiale and subfibulare using small incisions and for treatment of associated lesion. The preoperative radiological evaluation is essential and magnetic resornance image is useful for detecting of associated lesion.

  • PDF

A Study of Bone Uptake According to Renal Function in the Whole Body Bone Scan (전신 뼈 검사에서 신장 기능에 따른 뼈 섭취율에 대한 고찰)

  • Cho, Yong-In;Jang, Dong-Gun;Park, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.299-304
    • /
    • 2013
  • Whole body bone scan has been used to confirm bone metastasis and follow-up study with radio isotope. However, if the factors related to $^{99m}Tc$ uptake and waiting time for study are inappropriate, it would be image of low quality. The purpose of present study was to investigate correlation between the evaluation index of renal function and uptake of radiopharmaceuticals. The population for this retrospective study consisted of 387 patients who underwent whole body bone scan between June 2012 and December 2012. As a result of quantitative and qualitative analysis, we were able to confirm that GFR of less than normal range and creatinine levels in blood of more than average are more likely to be under the mean uptake rate. As a result of analysis on the indicator affecting soft-tissue and bone uptake, the correlation of all elements was somewhat low. Also there are no statistically significances due to the other parameters we did not deal with. Therefore, further research on additional factors is needed for exact study and improvement of the image quality.

Development of Eggs, Larvae and Juveniles of Loach, Misgurnus mizolepis $G\ddot{U}NTHER$ (미꾸라지의 난발생과 자치어)

  • KIM Yong Uk;KIM Dong Soo;PARK Yang Sung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.1
    • /
    • pp.16-23
    • /
    • 1987
  • The cyprinid loach, Misgurnus mizolepis $G\ddot{u}nther$, a freshwater teleost, is a member of the family Cobitidae and is known to distribute in Korea and China. This fish is considered to be an excellent food fish in Korea. This report is a description of the gross morphology of the embryos and larvae up to the development of juvenile period of life. The eggs were obtained by injecting gonadotropin and fertilized by wet method in the laboratory on July 10 in 1986. The inseminated eggs were rinsed with tap water and incubated at $25^{\circ}C$. Live, freshly laid eggs were separative, demersal, adhesive, light yellow and average 1.1mm in diameter. The hatching took place in about yellow and average 1.1mm in diameter. The hatching took place in about 24 hours after fertilization. The newly hatched larvae were average 2.7 mm in total length possessing yolk sac and 35-36 myotomes. Ten hours after hatching, the prelarvae attained 3.5 mm in total length. The first heart pulse and melanophores at the side of the body were observed at this stage. Yolk sac was completely reserved at four days after hatching. The larvae that was cultured 24 days after hatching, 15.4-16.4 mm in total length, entered the juvenile period of life. All the un rays were already peresent; D. III 6, A. III, 5, P.10, V. 4-5, C.14.

  • PDF