• Title/Summary/Keyword: 고주파신호

Search Result 457, Processing Time 0.025 seconds

On-Chip Design-for-Testability Circuit for RF System-On-Chip Applications (고주파 시스템 온 칩 응용을 위한 온 칩 검사 대응 설계 회로)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.3
    • /
    • pp.632-638
    • /
    • 2011
  • This paper presents on-chip Design-for-Testability (DFT) circuit for radio frequency System-on-Chip (SoC) applications. The proposed circuit measures functional specifications of RF integrated circuits such as input impedance, gain, noise figure, input voltage standing wave ratio (VSWRin) and output signal-to-noise ratio (SNRout) without any expensive external equipment. The RF DFT scheme is based on developed theoretical expressions that produce the actual RF device specifications by output DC voltages from the DFT chip. The proposed DFT showed deviation of less than 2% as compared to expensive external equipment measurement. It is expected that this circuit can save marginally failing chips in the production testing as well as in the RF system; hence, saving tremendous amount of revenue for unnecessary device replacements.

Programmable Compensation Circuit for GHz Band Devices (GHz 대역 소자를 위한 프로그램 가능 보상 회로)

  • Ryu, Jee-Youl;Noh, Seok-Ho;Kim, Sung-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.673-675
    • /
    • 2011
  • 본 논문은 GHz 대역 소자 응용을 위한 프로그램 가능 보상 회로를 제안한다. 이러한 회로는 5.2GHz대에서 동작하는 고주파 회로의 칩 제작과정에서 예기치 않게 발생한 미세한 PVT (공정, 전압, 온도) 변동을 검출하여 미세 변동된 회로 성능 변수들을 자동으로 보상한다. 자동으로 보상 가능한 고주파 회로 성능 변수들은 중요한 요소인 입력 임피던스, 전압이득과 잡음지수를 포함한다. 이러한 회로는 미세 변동을 자동으로 보상할 수 있도록 고주파 신호를 직류 신호로 변환하는 DFT (Design-for-Testability) 회로를 포함한다.

  • PDF

The Slop Compensation Algorithm of Speech Spectrum by QMF (Quadrature Mirror Filter) (QMF Filter에 의한 음성스펙트럼의 기울기 보상 알고리즘)

  • Min, So-Yeon;Bae, Myung-Jin
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.05a
    • /
    • pp.364-367
    • /
    • 2006
  • 음성신호를 관찰하였을 때 성문특성으로 인해서 고주파 쪽 특성이 약화되는 경향이 있다. 약화된 고주파 특성을 보상하기 위하여 프리 엠퍼시스 필터를 통해 보상하고 있다. 프리 엠퍼시스 필터를 간단한 수식으로 표현하면 y(n)=s(n)-As(n-1)와 같이 차분 방정식으로 나타낼 수 있다. 여기서 A값은 보통 0.9에서 1사이의 값을 사용한다. 본 논문에서는 QMF 필터를 이용하여 입력신호를 고주파와 저주파의 2개의 대역으로 분할하여 각 밴드에 프리 엠퍼시스 필터를 적용하여 약화되어진 특성을 정확히 보상하는 방법을 제안한다.

  • PDF

원격탐사위성의 탑재체자료전송장치를 위한 시험검증장비의 개발

  • Lee, Sang-Taek;Jin, Yeong-Bae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.228.2-228.2
    • /
    • 2012
  • 본 논문에서는 탑재체자료전송장치의 시험검증을 위한 장비 개발에 관하여 소개 한다. 원격탐사위성에 탑재되는 고성능원격측정센서는 대용량 데이터를 생성하며 탑재체자료전송장치를 통하여 고주파통신에 의해 지상으로 전송된다. 따라서 탑재체자료전송장치의 검증은 전체 인공위성 개발에 있어서 매우 중요하다. 시험검증장비는 송신되는 수신자료를 수신하여 여러 장비로 분배해주는 고주파신호분배모듈, 계측기 및 복조기 등 다양한 장비로 구성된다. 시험검증장비는 고성능 고주파신호 부품, 다양한 전자장비와 이를 통합, 제어 운영하는 다양한 복잡한 소프트웨어가 필요하여 개발이 어렵다. 본 논문에서는 초기 제작 시험검증장비와 최종 제작 시험검증장비 사이의 차이와 성능, 기능의 향상을 위한 설계변경 등을 통하여 이에 대한 어려움을 극복한 과정과 설계 근거와 장비 선택 등 제반사항에 대하여 기술하여 이후 관련 유사장비의 개발에 있어 도움이 되고자 한다.

  • PDF

Initial Pole-position Identification Algorithm of Linear Motor by High-frequency Signal Injection (고주파 신호 주입을 통한 선형 전동기의 초기 자극 위치 추정 알고리즘)

  • Hwang, Chae-Eun;Lee, Younggi;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.107-108
    • /
    • 2016
  • 본 논문에서는 위치 센서 없이 영구자석 선형 전동기의 초기 자극 위치를 추정하는 알고리즘을 제안하였다. 이 알고리즘은 선형 전동기의 고주파 특성을 이용하여 초기 자극 위치를 추정한다. 정지 좌표계 상에서 고주파 전압을 주입하였을 때 유도되는 전류 데이터를 추출하여 분석한 결과, 전류 파형과 기준 신호와의 위상 차이가 자극의 위치에 따라 180도의 주기를 가지고 달라짐을 확인하였다. 이러한 위상 차이와 자극의 위치 사이의 관계를 이용하여 초기 위치를 추정할 수 있다. 제안하는 방법은 이동자의 움직임을 필요로 하지 않으므로 선형 전동기의 수직 방향 움직임을 필요로 하는 분야에서 위 센서 없는 제어에 효과적으로 사용될 수 있다. 실험을 통해 알고리즘의 타당성 및 효과를 검증하였다.

  • PDF

High Frequency Signal Analysis of Oxidizer Pump for 7-tonf Turbopump (7톤급 터보펌프 산화제펌프의 고주파 신호 분석)

  • Bae, Joon-Hwan;Choi, Chang-Ho;Choi, Jong-Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.6
    • /
    • pp.61-68
    • /
    • 2020
  • 7-tonf turbopump real-propellant tests in Naro Space Center were conducted and high-frequency signals from an accelerometer and pressure sensors installed on the casing and the inlet/outlet pipeline of LOX pump were analyzed to estimate the structural and hydrodynamic stabilities. Waterfalls, frequency spectrums and RMS(Root Mean Square) values of the measured signals were calculated and characteristic instability frequencies by the rotating cavitation and the rear floating ring seal(F.R.S) were investigated. Static pressures of the inlet/outlet pipeline and an acceleration of the pump casing are strongly affected on pressure fluctuation induced by the rear floating ring seal in the leakage path. Despite the acceleration RMS value seems totally small, the rotating-speed-related synchronous frequency affecting the shaft instability is distinctly observed in the frequency contour.

Experimental Model of Frequency-Variant Transmission Line Parameter for High-Speed Signal Propagation Characterization (고속 신호의 전파 특성화를 위한 주파수 종속 전송선 파라미터의 실험적 모델)

  • Kim, Hyewon;Eo, Yungseon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.4
    • /
    • pp.73-80
    • /
    • 2013
  • In this paper, an experimental circuit model for an accurate high-frequency characterization of transmission line is proposed. Inherent resonance effects during measurements make it difficult to determine characteristic impedance and propagation constant at the resonance frequencies corresponding to the line length. Thus, resonance-effect-free transmission line parameter determination technique based on the physical insight and theory is proposed. Then, by using the parameters high-frequency circuit model is proposed for high-speed signal propagation characterization. The proposed frequency-variant transmission line model is verified with measurement and it can be usefully exploited in high-speed signal propagation characterization.

High Frequency Signal Analysis of LOx Pump for Liquid Rocket Engine under Cavitating Condition (캐비테이션 환경에서의 액체로켓엔진용 산화제펌프의 고주파 신호 분석)

  • Kim, Dae-Jin;Kang, Byung Yun;Choi, Chang-Ho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1093-1098
    • /
    • 2017
  • High frequency signals are analyzed which are measured at the inlet / outlet pipeline and pump casing during cavitation tests of the LOx pump for the liquid rocket engine. RMS values of data are shown according to the cavitation number. RMS values of the synchronous frequency, its harmonic frequencies and frequencies of cavitation instabilities are also calculated. The pressure pulsations of the inlet and outlet pipeline are affected by cavitation instabilities. 3x component is predominant in the outlet pulsation sensor since 3x component generated at the inducer is amplified at the impeller. The cavitation instability is also found at the accelerometer signal of the casing.

  • PDF

Power stabilization of a slab CO2 laser by using the Opto-Hertzian effect (Opto-Hertzian 효과를 이용한 고주파 여기식 슬랩 CO2 레이저의 출력 안정화)

  • 최종운;우삼용;김규식;이영우
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.4
    • /
    • pp.337-342
    • /
    • 2004
  • Laser optical power stabilization of a radio frequency excited $CO_2$ slab laser using the opto-Hertzian effect generated from the laser itself is achieved on the peak of the Doppler broadened gain curve. The opto-Hertzian signal was generated by a modulation of the optical flux circulating inside the laser cavity from a variation in the cavity length caused by the vibrations of the PZT. The opto-Hertzian signal is directly coupled from a RE discharge chamber via a loop antenna into a detector and applied to a lock-in stabilizer as an reference signal. The power stability of an RF excited slab laser is estimated to be better then 0.2%.

Signal transient simulation of multi-coupledm frequency-variant transmission lines (주파수 종속 다중 전송선의 신호 천이 특성)

  • Cho, Young-Il;Eo, Yung-Seon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.12 s.354
    • /
    • pp.89-101
    • /
    • 2006
  • Frequency-variant transmission line parameters are determined. Then the signal transient characterizations of frequency-dependent multi-coupled lines are investigated. With the proposed method, an accurate signal integrity degradation such as signal ringing (overshoot, undershoot) and crosstalk noises relevant to the switching patterns of signals, rising / falling time(tr, tf) and line lengths is investigated. It is shown that there may be approximately 26% discrepancy of signal transients and 260% difference of crosstalk noises between the constant RLC model and frequency-variant RLC model in on-chip global interconnects while those of package lines are 11% and 70%, respectively.