• 제목/요약/키워드: 고조파 해석

검색결과 255건 처리시간 0.034초

고조파 전류원에 의한 콘덴서 임피던스 특성 해석 (Analysis of Impedance Performance for Condenser by Harmonic Current Source)

  • 김종겸;박영진
    • 조명전기설비학회논문지
    • /
    • 제25권4호
    • /
    • pp.57-64
    • /
    • 2011
  • Most of the user has been used linear load and non-linear load. The former is usually inductive load which is needed power factor compensation, the latter is power conversion system device. Actually two kinds of load is used together in the customer application. Generally capacitor is used for power-factor compensation of inductive load and reduction harmonics of non linear load with reactor. Non-linear load generates harmonic current for its energy conversion process. If harmonic current pass along the low impedance side of distribution system, the magnification of voltage and current is appeared by the series and parallel resonance. As a result, condenser has received a bitter electrical stress by the harmonic component. In this paper, we analyzed that how resonance is changed by the 5-th harmonic current pattern and proposed an alternative plan for non-magnification.

전압 및 주파수 변동에 따른 콘덴서 열 분포 해석 (Analysis of Condenser Thermal Distribution by the Variance of Voltage & Frequency)

  • 김종겸;박영진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.33-36
    • /
    • 2009
  • 콘덴서는 유도성 부하의 늦은 역률 보상으로도 사용되며, 비선형 부하에서 발생하는 고조파를 저감하기 위해 리액터에 직렬로 연결하여 사용되기도 한다. 콘덴서는 전압이 증가할 경우 전류도 함께 증가하고, 주파수가 증가할 경우 콘덴서에 흐르는 전류가 증가하기 때문에 전류의 증가는 바로 열의 증가로 콘덴서 절연에 스트레스로 작용하여 고장의 원인을 제공할 수 있다. 본 연구에서는 콘덴서에 인가되는 전압의 크기와 주파수를 변화시킬 경우 콘덴서에서 발생하는 열을 열화상 카메라로 측정하여 외부 및 내부에서의 온도분포를 분석하였다. 측정결과 전압과 주파수가 증가할 경우 콘덴서에서 열이 매우 높게 분포함을 확인할 수 있었다.

  • PDF

PMLSM의 디텐트력 저감을 위한 보조코어의 설계 (The Design of Auxiliary-core for Reducing Detent Force)

  • 장우성;김지현;안호진;장기봉;김규탁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.883_884
    • /
    • 2009
  • PMLSM에서는 전기자 권선부의 슬롯-치 구조로 인한 디텐트력과 단부효과에 의한 디텐트력, 영구자석의 고조파 성분 자속에 의한 디텐트력이 발생한다. 따라서, 본 연구에서는 자기저항의 불연속으로 인한 디텐트력을 제거시키기 위하여 전기자 권선과는 독립된 자기회로를 가지는 보조코어의 설치를 제안하였다. 보조코어의 최적 설계는 유한요소 해석과 실험계획법을 이용하였으며 이론치와 실험치를 비교함으로서 본 연구의 타당성을 입증하였다.

  • PDF

자가용 전기설비의 비상용 예비발전설비 사고사례 분석 (The Analysis of Accidents on an auxiliary power system in case of a blackout)

  • 최명일;배석명;유재근;전정채;임용배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2170_2171
    • /
    • 2009
  • 비상용 예비전원설비는 정전이 되었을 경우 건축물의 기능 유지나 영업을 위해 최소한의 방재와 비상전력을 확보하기 위한 설비이다. 그러나 최근 부하운전시험으로 발전기 가동시 부하단의 콘덴서, 고조파, UPS와 같은 SCR 부하의 영향으로 발전기 전원측에서 이상전압이 발생하여 과전압이 부하에 공급되어 기기가 소손되는 사고가 빈번히 발생하고 있다. 본 논문에서는 국내의 국내 예비발전설비의 운용 현황과 발전기 보호시설 유무에 대한 실태조사를 하였고, 최근 10년간 발전기 관련 사고 사례를 조사하여 사고의 원인을 분석하였다. 또한 발전기의 부하운전시 발전전원측의 전원품질을 측정하여 향후 사고해석 SW를 이용하여 시뮬레이션 및 사고재연 실증시험을 통해 보다 정확한 사고원인 및 사고발생 대책을 제시하는데 자료로 이용 될 것이다.

  • PDF

고조파 필터용 커패시터와 리액터의 특성 해석 (Characteristics Analysis of Capacitor and Reactor for Harmonic Filter)

  • 김종겸;박영진;이은웅
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.1-8
    • /
    • 2009
  • Recently, application of non-linear load is gradually increased. Non-linear load produces harmonic components of current during the energy conversion transition. Passive filter is used for reducing of harmonics in the user power systems. This filter, which is composed of capacitor and reactor, frequently get out of order by electrical stress. There are voltage and current increase when capacitor and reactor are applied in the user's filter systems. If increased voltage and current is above stipulated values, they have severely an influences on the life of capacitor and reactor. This paper describes that the voltage and current of capacitor used for filter is within the limits of allowable values, but reactor is beyond the limits and reveals spike voltage. Therefore this phenomenon brings about premature fault of reactor and capacitor.

고조파, 와전류 및 열 해석을 통한 BLDCM, IPMSM의 특성비교 (A characteristic comparison of BLDCM, IPMSM by harmonics, eddy current and thermal analysis)

  • 진창성;배재남;김기찬;손락원;김솔;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.25-27
    • /
    • 2007
  • Brushless DC Motor (BLDCM) is DC motor and Interior PM Synchronous Motor (IPMSM) is AC motor. Besides their way of control is different. But it is similar that both motors rotate synchronous velocity and use the permanent magnet. So, it is an objective to grasp a tendency of motor design and efficiency of motor through a characteristic comparison of BLDCM and IPMSM with the same power, rotation velocity, torque and input voltage.

  • PDF

공간 고조파를 고려한 L.I.M.의 특성해석에 관한 연구 (A study on the characteristics analysis of L.I.M. considering space harmonics)

  • 임달호;김규탁;김윤현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.325-328
    • /
    • 1988
  • Until now to analysis of LIM first winding current distribution is assumed to be finite sinusoidal current. But this method have demerits to learn the difference of LIM's characteristics which is produced by difference of winding method. So in this paper amodel of which period is the length core and air gap mmf of this winding current developed to fourier series, then mmf which contain air gap mmf is obtained this mmf is transformed to current sheet and the analysis result which are obtained by using sinusoidal first current and proposed method are compared.

  • PDF

고조파를 고려한 극변환(2/4극) 콘덴서 구동형 단상유도전동기 특성해석 (Characteristic Analysis of Capacitor-Run Single-Phase Pole Change Induction Motor Considering Harmonics)

  • 남혁;홍정표;정승규;정태욱;백승면
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.907-909
    • /
    • 2001
  • This paper proposes the analysis method for the pole change motor that is a capacitor-run single-phase induction motor. As the Magneto motive force(MMF) at 2-role becomes severe distortion, it is necessary to consider the harmonics for the characteristic analysis of the motor. Therefore, the performance of motor is analyzed by equivalent circuit considering the harmonic components. The validity of the proposed analysis method for the pole change motor is verified through simulations and experimental results.

  • PDF

역률개선과 고조파 저감을 위한 전류공진 승압형 AC-DC 컨버터의 특성 해석 (Analysis of Characteristics for Current Resonant type Boost AC-DC Converter for PFC and Reducing Harmonics)

  • 라병훈;송대현;서기영;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.341-344
    • /
    • 2001
  • In this paper, the characteristics of the proposed converter are show by simulation. As a result, the power factor is improved and the results show the usefulness of the proposed circuit. To improve the hard switching at turn-off of the basic circuit, the circuit using a current resonant switch is proposed. In the proposed circuit, THD of the input current is reduced to 1.8 of the basic circuit. The mechanism of the THD reduction is clarified. That is because the on period becomes shorter at the peak of the source voltage. Using the simulation, the characteristics of the output voltage, current flowing the switch, and THD of the input current are investigated by changing the resonant circuit parameters. Criteria for choosing resonant parameters of smaller THD are obtained.

  • PDF

전철 급전계통의 고조파 실측 및 해석결과 비교검증 (Harmonics Analysis in eletric railroad feed system)

  • 최흥관;윤재영;이종우;오광해
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.149-151
    • /
    • 2000
  • This paper compares the measurement values of harmonics to the analysis results in railroads testing system. Therefore, in this paper, new program to calculate THD(Total Harmonic Distortion) and measuring system of harmonics are developed. The harmonic measurement point is PCC(Point of Common Coupling), the primary side(154kV) of scott transformer, and the analysis is performed based on real KEPCO system data. As a result of this study, it is possible to present basic data and informations about harmonic problems which can be occurred in the future commercial railroad systems.

  • PDF