• Title/Summary/Keyword: 고로슬래그

Search Result 926, Processing Time 0.034 seconds

Thermal Characteristics of Concrete Fabricated with Blast Furnace Slag Subjected to Thermal Cycling Condition (고로슬래그 혼입 콘크리트의 고온 조건에서의 열역학 성능)

  • Yang, In-Hwan;Park, Ji-Hun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.414-420
    • /
    • 2017
  • The thermal characteristics of concrete fabricated with blast furnace slag were investigated in this paper. Test parameters included water-binder ratio and the content of furnace slag. Experimental program were performed to measure mechanical properties including compressive strength and split tensile strength under high-temperature thermal cycling, and to measure thermal properties including thermal conductivity and specific heat. Test results showed that the residual compressive strength of mixtures with blast furnace slag was greater than that of mixture without blast furnace slag. In addition, thermal conductivity of mixtures with blast furnace slag was greater than that of mixtures without blast furnace slag. It indicates that blast furnace slag was favorable for charging and discharging in thermal energy storage system. Test results of this study would be used to design concrete module system of thermal energy storage.

A Study on the Strength Property of Recycled Fine Aggregate (Wet Type) Mortar with Blast Furnace Slag (고로슬래그를 사용한 습식 순환 잔골재 모르타르의 강도 특성에 관한 연구)

  • Shim, Jong-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.153-160
    • /
    • 2010
  • This study aims to obtain technical data for improvement of utilization of Blast Furnace Slag(BFS), recycled aggregate in the future by complementing fundamental problems of BFS such as manifestation of initial strength and excessive alkali quantity as well as weakness of recycled fine aggregate through manufacturing of recycled fine aggregate mortar using BFS. The recycled aggregate includes the cement paste hardened as the surface and the type of the aggregate, which contains plenty of calcium hydroxide($Ca(OH)_2$) as well as the unhydrated cement. Accordingly, the objectives of this study are to inspect the manufacturing the recycled fine aggregate mortar used with blast furnace slag, to consider the effects of the recycled aggregate on the strength development of ground granulated blast furnace slag, and then to acquire the technical data to take into consideration the further usages of the recycled aggregate and blast furnace slag. In eluted ions from recycled aggregate, it showed that there were natrium($Na^+$) and kalium($K^+$), expected to be flown out of unhydrated cement, as well as calcium hydroxide($Ca(OH)_2$). Application of this water to mix cement mortar with ground granulated blast furnace slag was observed to expedite hydration as calcium hydroxide($Ca(OH)_2$) and unhydrated cement component were expressed to give stimuli effects on ground granulated blast furnace slag. The results of the experiment show that the recycled aggregate mixed with blast furnace slag has comparatively higher hydration activity in 7 day than the mortar not mixed with one in 3 day mortar does, causing the calcium hydroxide in the recycled fine aggregate to work on as a stimulus to the hydration of ground granulated blast furnace slag.

Strength Properties of SBR-Modified Concretes Using Ground Granulated Blast-Furnace Slag (고로슬래그 미분말을 이용한 SBR혼입 폴리머 시멘트 콘크리트의 강도특성)

  • ;;Yoshihiko Ohama
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.3
    • /
    • pp.315-320
    • /
    • 2002
  • The effects of slag content and polymer-binder ratio on the strength properties of the polymer-modified concretes using ground granulated blast-furnace slag and a styrene-butadiene rubber (SBR) latex are examined. As a result, the compressive, tensile and flexural strengths of the SBR-modified concretes using slag increase with increasing polymer-binder ratio and slag content, and maximized at a slag content of 40 %. In particular, the SBR-modified concretes with a slag content of 40 % provide approximately two times higher tensile and flexural strengths than unmodified concretes. Such high strength development is attributed to the high tensile strength of SBR polymer and the improved bond between cement hydrates and aggregates because of the addition of SBR latex.

Evaulation of Adiabatic Temperature Rise for Concrete with Blast-Furnace Slag replacement (고로슬래그 미분말 치환율에 따른 콘크리트의 단열온도상승 평가)

  • Kim, Joo Hyung;Lee, Do Heun;Jung, Sang Hwa
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.18-24
    • /
    • 2013
  • Recently, the interest is increasing about the eco-friendly concrete. Accordingly, the blast furnace slag(BFS), a by-product of industry is known for improving the durability through compaction in concrete and is expanding the use. The research about BFS in concrete be accomplished frequently. In this study, we should know the hydration characteristic of BFS concrete the through the adiabatic temperature rise test due to the replacement of a variety of BFS. In addition, we produced the regression analysis factors through the test result and analyzied the effect for the replacement of BFS. According to test results, the compressive strength showed a slight degradation or equal and the the adiabatic temperature rise figure and rising factors are went down for rising replacment of BFS. In the future, the study about the adiabatic temperature rise equation for the various replacement of BFS and binder is considered necessary.

  • PDF

Effect of Addition of Ground Granulated Blast-furnace Slag on Strength Properties of Autoclaved Polymer-Modified Concrete (오토클레이브 양생 폴리머 시멘트 콘크리트의 강도성상에 미치는 고로슬래그 미분말 혼입의 영향)

  • 주명기
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.608-614
    • /
    • 2002
  • The effects of slag content and polymer-binder ratio on the strength properties of autoclaved SBR-modified concretes using ground granulated blast-furnace slag(slag) and a styrene-butadiene rubber (SBR) latex are examined. As a result, the compressive and tensile strengths of the autoclaved SBR-modified concretes using slag increase with increasing slag content, and reach a maximum at a slag content 40%, and increase with increasing polymer-binder ratio. In particular, the autoclaved SBR-modified concretes with a slag content of 40% provide about three times higher tensile strength than unmodified concretes. Such high strength development is attributed to the high tensile strength of SBR polymer and the improved bond between cement hydrates and aggregates because of the addition of SBR latex.

The Microstructure and Durable Properties of the Composites with the Ground Granulated Blast Furnace Slag (고로슬래그 미분말을 사용한 몰탈의 미세구조와 내구특성)

  • Kim, Won-Ki;Soh, Jung-Sub;Kim, Dong-In;Kim, Hoon-Sang;Kim, Hong-Joo
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2004.05a
    • /
    • pp.143-148
    • /
    • 2004
  • 고로슬래그 미분말과 플라이 애쉬와 같은 재료들이 콘크리트의 내구성과 장기강도 증진을 목적으로 혼합재로서 사용되고 있다. 본 연구에서는 고로슬래그 사용 몰탈의 내구성 증진 특성을 활용하기 위하여 고로슬래그 미분말에 알칼리 자극제를 첨가한 알칼리 활성화 슬래그계 무기결합재 사용 몰탈의 내구성과 물리적 특성을 평가하였다. 실험결과, 몰탈의 초기 압축강도 발현에 알칼리 자극제가 큰 영향을 미치는 것을 확인하였다. 또한 알칼리 자극제가 첨가된 몰탈의 화학적 저항성을 평가하기 위하여 공시체를 재령 28 일 후, 5% 황산($H_2SO_4$) 용액에 침지하여 압축강도 및 질량 변화를 관찰하였다. 그 결과, 보통포틀랜드 시멘트로 제조한 몰탈의 경우, 황산용액 침지 후 압축강도가 54% 감소하였다. 반면 고로슬래그 미분말을 첨가한 몰탈의 경우, 약 10% 강도가 감소하였다. 질량변화의 경우, 보통포틀랜드 시멘트로 제조한 공시체는 17%, 고로슬래그 미분말을 첨가한 몰탈은 3%의 질량변화를 보였다. 이 결과로서 고로슬래그 미분말을 첨가한 몰탈의 경우, 화학적 저항성과 물리적 특성이 우수한 것을 확인하였다.

  • PDF

Strength and Durability of Polymer-Modified Mortars Using Ground Granulated Blast-Furnace Slag (고로슬래그 미분말을 혼입한 폴리머 시멘트 모르타르의 강도 및 내구성)

  • 주명기;김남길;연규석
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.2
    • /
    • pp.164-170
    • /
    • 2002
  • Effect of the polymer-binder ratio and slag content on the properties of combined wet/dry-cured polymer-modified mortars using granulated blast-furnace slag are examined. Results shows that the flexural and compressive strengths of polymer-modified mortar using the slag tend to increase with increasing slag content, and reaches a maximum at a slag content of 40 %, and is inclined to increase with increasing polymer-binder ratio. Water absorption, carbonation depth and chloride ion penetration depth tend to decrease with increasing polymer-binder ratio and slag content. Accordingly, the incorporation of slag into polymer-modified mortars at a slag content of 40% is recommended for a combined wet/dry curing regardless of the types of polymer.

Structural Capacity of Water Channel Fabricated of Blast Furnace Slag Concrete (고로슬래그를 혼입한 콘크리트 수로관의 구조 성능)

  • Yoo, Sung-Won;Yang, In-Hwan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.446-453
    • /
    • 2016
  • Structural capacity of water channel fabricated of concrete including blast furnace slag were investigated in this paper. An experimental study was consisted of materials test and structural test of concrete water channel. The mechanical properties of concrete including blast furnace slag were investigated. Ordinary Portland cement (OPC) was used as basic binder and the effect of the replacement of blast furnace slag for OPC was investigated. Experiments were performed to measure mechanical properties including compressive strength, elastic modulus and modulus of rupture. Test results show that the compressive strengths and modulus of ruptures of mixtures containing blast furnace slag were equivalent to those of OPC concrete. In addition, the structural capacity of concrete water channel with up to the replacement ratio of blast furnace slag of 45% was greater than the required strength in KS specification.

Strength and Shrinkage of Geopolymer Mortar with Mineral Admixtures (혼화재료에 따른 지오폴리머의 강도 및 건조수축)

  • Yang, Joo-Kyoung;Kim, Hyo-Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.45-53
    • /
    • 2019
  • Slump flow, compressive strength, flexural strength and drying shrinkage were measured to evaluate workability and mechanical performance of geopolymer. Experimental parameters include the addition of gypsum, blending ratio of blast furnace slag and fly ash and addition of shrinkage reducing agent. Geopolymer using blast furnace slag mixed with gypsum showed larger slump flow than blast furnace slag without gypsum. The slump flow when blending ratio of blast furnace slag and fly ash is 5:5 tended to be larger than the slump flow when blending ratio is 8:2. Geopolymer using blast furnace slag without gypsum showed higher compressive strength and flexural strength than blast furnace slag mixed with gypsum. Compressive strength and flexural strength tended to be higher when blending ratio of blast furnace slag and fly ash was 8:2 than when blending ratio was 5:5. Drying shrinkage decreased with increasing fly ash and blast furnace slag without gypsum, and it was found that shrinkage reducing agent is effective to reduce drying shrinkage of geopolymer.

Strength and Durability Properties of Concretes Using Ground Granulated Blast-Furnace Slag According to Steam Curing Types (고로(高爐)슬래그 미분말(微分末)을 사용한 콘크리트의 증기양생(蒸氣養生)에 따른 강도(强度) 및 내구특성(耐久特性))

  • Hong, Chang-Woo;Jang, Ho-Sung;Jeong, Won-Kyong
    • Resources Recycling
    • /
    • v.15 no.4 s.72
    • /
    • pp.52-59
    • /
    • 2006
  • The purpose of this study was to evaluate the effects of ground granulated blast-furnace slag on strength development and durability of ordinary portland cement concrete (OPC) with steam curing types. Main experimental variables were slag contents(0%, 10%, 30%, 50%, 70%) and curing types (standard, accelerated curing). It were performed to check the basic properties of concretes that compressive strength, rapid chloride ion permeability and chemical resistance. From the result, we have found that increasing the amount of blast-furnace slag produced concrete with increased compressive strength and permeability resistance. Rapid freezing-thawing test showed that they were good enough to protect the concrete structures and to carry out cyclic freezing and thawing. The freeze-thaw resistance of blast-furnace slag produced concretes maintained above 90% of relative dynamic modulus after 300 freezing-thawing cycles. Increasing the amount of blast-furnace slag produced concretes with increased chemical resistance.