Investigation of the Regression Analysis Method for a Quantitative Evaluation of Implant Crestal Bone Stresses (회귀분석법에 의한 임플란트 경부골 응력의 정량적 분석에 대한 연구)

  • Kim, Woo-Shik;Jo, Kwang-Hun;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.299-310
    • /
    • 2008
  • In this study, the regression analysis method was tested for the estimation of peak stress at stress concentration area in the cervical bone. Submerge type EZ plus implant (Megagen. Daegu, Korea), 4.1 mm in cervical diameter and 9.6 mm in endosseous length, were axisymmetrically modelled together with surrounding alveolar bone of which the width was 10 mm. Vertical force of 100 N was applied to a head of crown above 8.5 mm from the outer surface of the cortical bone. Four different mesh models were composed of differently sized elements in vicinity of sharp corners, and they include 6 stress monitoring points that are located in the same geometrical points regardless of the differences in the meshes. Primary consideration was given to the stresses in the cortical bone surrounding the implant neck. The results showed that virtually all the stresses were concentrated in the cortical bone regardless of mesh designs. The peak stresses were successfully calculated by a regression analysis in a stable manner, as far as the mesh is designed to represent the acute gradient of stresses near the sharp corner.

Finite element analysis of peri-implant bone stress influenced by cervical module configuration of endosseous implant (임플란트 경부형상이 주위골 응력에 미치는 영향에 관한 유한요소법적 분석)

  • Chung, Jae-Min;Jo, Kwang-Heon;Lee, Cheong-Hee;Yu, Won-Jae;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.394-405
    • /
    • 2009
  • Statement of problem: Crestal bone loss, a common problem associated with dental implant, has been attributed to excessive bone stresses. Design of implant's transgingival (TG) part may affect the crestal bone stresses. Purpose: To investigate if concavely designed geometry at a dental implant's TG part reduces peri-implant bone stresses. Material and methods: A total of five differently configured TG parts were compared. Base model was the ITI one piece implant (Straumann, Waldenburg, Switzerland) characterized by straight TG part. Other 4 experimental models, i.e. Model-1 to Model-4, were designed to have concave TG part. Finite element analyses were carried out using an axisymmetric assumption. A vertical load of 50 N or an oblique load of 50 N acting at $30^{\circ}$ with the implant's long axis was applied. For a systematic stress comparison, a total of 19 reference points were defined on nodal points around the implant. The peak crestal bone stress acting at the intersection of implant and crestal bone was estimated using regression analysis from the stress results obtained at 5 reference points defined along the mid plane of the crestal bone. Results: Base Model with straight configuration at the transgingival part created highest stresses on the crestal bone. Stress level was reduced when concavity was imposed. The greater the concavity and the closer the concavity to the crestal bone level, the less the crestal stresses. Conclusion: The transgingival part of dental implant affect the crestal bone stress. And that concavely designed one may be used to reduce bone stress.

Cervical design effect of dental implant on stress distribution in crestal cortical bone studied by finite element analysis (유한요소법을 이용한 임플란트 경부 디자인이 골응력에 미치는 영향 분석)

  • Kim, Kyung-Tak;Jo, Kwang-Heon;Lee, Cheong-Hee;Yu, Won-Jae;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.385-393
    • /
    • 2009
  • Statement of problem: High stress concentration on the crestal cortical bone has been regraded as a major etiologic factor jeopardizing long term stability of endosseous implants. Purpose: To investigate if the design characteristics of crestal module, i.e. internal type, external type, and submerged type, affect stress distribution on the crestal cortical bone. Material and methods: A cylindrical shaped implant, 4.3 mm in diameter and 10 mm in length, with 3 different crestal modules, i.e. internal type, external type, and submerged type, were analysed. An axisymmetric scheme was used for finite elment formulation. A vertical load of 50 N and an oblique load of 50N acting at $45^{\circ}$ with the implant's long axis was applied. The peak crestal bone stress acting at the intersection of implant and crestal bone was compared. Results: Under vertical load, the crestal bone stress was high in the order of internal, external, and submerged types. Under the oblique loading condition, it was in the order of internal, submerged, and external types. Conclusion: Crestal module design was found to affect the level of the crestal bone stresses although the actual amount was not significant.

3-D FEA of three different single tooth abutments : Cement-retained Vs Screw-retained (3종의 단일치아 수복용 지대주의 삼차원 유한요소법적연구 : 시멘트 유지헝 대 나사 유지형)

  • Lee, Jung-Min;Kim, Yung-Soo;Kim, Chang-Whe;Kim, Yong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.269-288
    • /
    • 1999
  • 현재 골 유착성 임플랜트는 안전하고 유용한 보철 수복 분야의 하나로 자리잡아 가고있다. 과거 완전 무치악 환자에게 있어서 저작 기능의 회복이란 면에 중점을 두었던 경향에서 현재 골유착 임플랜트의 높은 성공률에 의해 부문 무치악, 단일치 수복에 까지 다양하게 사용되고 있다. 특히 심미성과 인접치의 손상을 가하지 않는다는 면에서 단일치 수복에서 골유착 임플랜트 치료에 관심이 모아지고 있다. 단일치 수복에 있어서 심미성이 중요한 문제로 대두되면서 이런 수복에 사용될 수 있는 다양한 계통의 임플랜트들이 개발되어 사용되고 있다. 이중 가장 기본적인 Branemark 계통의 CeraOne 지대주, 최근에 개발된 전부도재 지대주인 CerAdapt 전부주조 지대주인 UCLA 계통등은 높은 성공률을 보이며 많이 사용되고 있다. 임상가들에 의해 나사유지형 보철물이 착탈성이란 관점에서 선호되고 있다. 시멘트유지형 보철물에서는 나사공이 없는 온전한 교합면을 유지한다는 면과 교합력을 받는 면적에 있어서 더 넓은 면을 가진다는 점등 더 많은 장점을 가진다고 주장하는 사람도 있다. 임상가들의 기호에 의해 선택되어지는 나사 유지형과 시멘트 유지형에 있어서 교합력이 야기하는 하중하에서 각각의 응력 분포를 분석할 필요성이 요구되었다. 이 연구는 단일치 수복에 사용되는 CeraOne, CerAdapt UCLA 계통에서 각각의 나사 유지형과 시멘트유지형에서의 응력분포를 삼차원 유한요소법으로 분석하고 상부 구조물에 가해지는 수직하중, 수평 하중, 경사 하중에 의해 야기되는 응력을 비교 분석한 것이다. 본 연구의 연구 결과는 다음과 같다. 1. CeraOne, CerAdapt, UCLA 지대주 모두 시멘트유지형보다 나사유지형에서 응력집중이 컸다. 2. CeraOne 시멘트유지형인 1번 모델에서 응력분산이 유리하였고, UCLA 나사 유지형인 6번 모델에서 가장 불리하였다. 3. 모든 모델에서 고정체 경부에서 가장 큰 응력 집중이 있었고 이것은 UCLA 지대주에서 가장 컸다. 4. 상부 구조물에서 주된 응력의 집중은 교합면에서 일어났다. 5. 골은 상부 피질골, 즉 고정체경부와 만나는 부위에서 가장 큰 응력의 집중이 일어났으며 수평, 경사 하중시 응력집중 양상은 힘을 가한 쪽의 반대쪽 고정체 경부에 응력이 집중되는 양상을 보였다. 6. 전체 모델과 골, 고정체 모두에서 수평 하중과 경사 하중시 보다는 수직 하중시 더 적은 응력값을 보였다.

  • PDF

Analysis on Femoral Neck Fractures Using Morphological Variations (파라메트릭 형상모델을 이용한 근위 대퇴골의 경부 골절 영향 해석)

  • Lee, Ho-Sang;Park, Byoung-Keon;Chae, Je-Wook;Kim, Jay-Jung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.459-465
    • /
    • 2011
  • It has been reported that the femoral morphology has a major correlation to femoral neck fractures(FNF). Previous studies to analyze these correlations have relied on mechanical testing and finite element methods. However, these methods have not been widely applied to various femur samples and models. It is because of the availability of the samples from both patients and cadavers, and also of the geometric limitations in changing the shape of the models. In this study we analyzed femoral neck fractures using a parameterized femoral model that could provide flexibility in changing the geometry of the model for the wide applications of FNF analysis. With the parameterization a variety of models could be generated by changing four major dimensions: femoral head diameter(FHD), femoral neck diameter(FND), femoral neck length(FNL), and neck-shaft angle(NSA). We have performed FEA on the models to compute the stress distributions and reaction forces, and compare them with the data previously generated from mechanical testing. The analysis results indicate that the FND is significantly related with the FNF and the FHD is not significantly related with the FNF.

Effects of Coronal Thread Pitch in Scalloped Implant with 2 Different Connections on Loading Stress using 3 Dimensional Finite Element Analysis (연결부 형태가 다른 두 가지 scallop 임플란트에서 경부 나사선 피치가 응력 분포에 미치는 영향 : 삼차원적유한요소분석)

  • Choi, Kyung-Soo;Park, Seong-Hun;Lee, Jae-Hoon;Huh, Jung-Bo;Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.111-118
    • /
    • 2013
  • Purpose of present study is to investigate the effects of thread pitch in coronal portion in scalloped implant with 2 different connections on loading stress using 3 dimensional finite element analysis. Scalloped implant with 4 different thread pitches (0.4mm, 0.5mm, 0.6, and 0.7mm) in the coronal part was modeled with 2 different implant-abutment connections. Platform matching connection had the same implant and abutment diameter so that they were in flush contact at the periphery while platform mismatching connection had smaller abutment diameter than implant so that their connection was made away from periphery of implant-bone interface. Occlusal loading of 100N force was applied vertically and 30 degree obliquely to all 8 models and the maximum von Mises bone stress was identified. Loading stress as highly concentrated in cortical bone. Platform mismatching scalloped implant with small thread pitch (0.4mm) model had consistently lowest maximum von Mises bone stress in vertical and oblique loads. Platform matching model had lowest maximum von Mises bone stress with 0.6mm thread pitch in vertical load and with 0.4mm thread pitch in oblique load. Platform mismatching connection had important roles in reducing maximum von Mises bone stress. Scalloped implant with smaller coronal thread pitch showed trend of reducing maximum von Mises bone stress under load.

A three-dimensional finite element analysis of osseointegrated implant on stress distribution in different abutment designs and fixture diameters (각종 지대주 및 고정체 종류에 따른 골유착성 임플랜트의 응력 분포에 관한 삼차원 유한요소분석적 연구)

  • Kwon, Ho-Beom;Kim, Chang-Whe;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.699-721
    • /
    • 1996
  • 브로네마르크가 골유착성 임플랜트를 소개한 이래로, 현재 골유착성 임플랜트에 의한 치료는 안전하고 안정적인 방법으로 여겨지고 있다. 골유착성 임플랜트를 이용한 초기의 치료는 무치악 환자의 저작기능 회복에 중점을 두어 왔다. 그러나 현재는 환자와 시대의 요구에 따라서 심미성이 주요한 관심사가 되었다. 그래서 표준 지대주보다 더 심미적인 지대주 시스템들이 개발되었다. 다양한 직경의 임플랜트 고정체에 관한 임상가들의 요구에 의해 직경 이 큰 고정체가 생산되기 시작했으며, 5mm의 직경을 갖는 고정체가 그 예이다. 골유착성 임플랜트를 사용하여 보철치료를 할 때, 골과 고정체의 계면은 보철물과 지대주에 가해지는 교합력을 인접골에 전달하게 되며, 이것은 계면에 생물학적인 반응을 야기할 수 있다. 임플랜트의 형태는 골흡수와 같은 바람직하지 않은 반응을 일으키지 않도록 고안되어야 하며, 임플랜트 자체가 교합력을 견딜 수 있어야 한다. 그러므로 골유착성 임플랜트 시스템을 임상에 사용하려고 할 때 이것의 생역학적 분석은 반드시 필요하다. 본 연구에서는 삼차원 유한요소분석적 방법을 사용하여 3.75mm직경을 갖는 고정체에 표준 지대주, 이세티콘 지대주, 마이러스콘 지대주를 연결한 모델과 5mm 직경을 갖는 고정체에 표준 지대주를 연결한 모델에 각각 수직하중, 경사하중, 수평하중을 가했을 때의 응력분포를 비교하였다. 본 연구의 결과는 다음과 같다. 1. 모든 모델에서 금나사의 경부, 금원주, 지대주에 응력의 집중이 일어났다. 2. 임플랜트 고정체에서는 고정체 상방 2/3, 그리고 지대주와 접촉하는 고정체 상면에서 응력의 집중이 관찰되었다. 3. 골에서는 상부 피질골에 응력의 집중이 관찰되었으며, 해면골에서는 두드러진 응력의 집중을 보인 부위는 없었으나 고정체의 근단부 주위 해면골에서의 응력값이 비교적 높았다. 4. 5mm 직경의 고정체를 사용하지 않은 모델 중에서, 표준 지대주를 사용한 경우가 가장 응력분산에 유리하였으며 마이러스콘 지대주를 사용한 경우가 가장 불리하였다. 5. 3가지 하중 조건하에서 수평하중과 경사하중의 경우가 수직하중의 경우보다 더 높은 응력값이 관찰되었다. 6. 응력값은 골에서보다 임플랜트 내부에서 훨씬 높았다.

  • PDF

Influence of crestal module design on marginal bone stress around dental implant (임플란트 경부 디자인이 변연골 응력에 미치는 영향)

  • Lim, Jung-Yoel;Cho, Jin-Hyun;Jo, Kwang-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.224-231
    • /
    • 2010
  • Purpose: This study was to investigate how the crestal module design could affect the level of marginal bone stress around dental implant. Materials and methods: A submerged implant of 4.1 mm in diameter and 10 mm in length was selected as baseline model (Dentis Co., Daegu,Korea).A total of 5 experimental implants of different crestal modules were designed (Type I model : with microthread at the cervical 3 mm, Type II model : the same thread pattern as Type I but with a trans-gingival module, Type III model: the same thread pattern as the control model but with a trans-gingival module, Type IV model: one piece system with concave transgingival part, Type V model: equipped with beveled platform). Stress analysis was conducted with the use of axisy mmetric finite element modeling scheme. A force of 100 N was applied at 30 degrees from the implant axis. Results: Stress analysis has shown no stress concentration around the marginal bone for the control model. As compared to the control model, the stress levels of 0.2 mm areas away from the recorded implant were slightly lower in Type I and Type IV models, but higher in Type II, Type III and Type V models. As compared to 15.09 MPa around for the control model, the stress levels were 14.78 MPa, 18.39 MPa, 21.11 MPa, 14.63 MPa, 17.88 MPa in the cases of Type I, II, III, IV and V models. Conclusion: From these results, the conclusion was drawn that the microthread and the concavity with either crestal or trans-gingival modules maybe used in standard size dental implants to reduce marginal bone stress.

A Three-dimensional Photoelastic Analysis of Stress Distributions Around Osseointegrated Implants and Abutment Teeth According to Bridge Connecting Type (골유착성(骨癒着性) 임플란트와 치아간(齒牙間)의 보철물(補綴物) 연결(連結) 형태(形態)에 따른 주위(周圍) 골조직(骨組織)의 응력분산(應力分散)에 관한 3차원적(次元的) 광탄성(光彈成) 분석(分析))

  • Lee, Moo-Geon;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.120-147
    • /
    • 1994
  • This study was performed for the purpose of evaluating the stress distribution around threaded type implants, cylindrical type implants and teeth connected with rigid or non-rigid connector. The stress distribution around the surrounding bone was analyzed by three-dimensional photoelastic method. Twelve mandibular photoelastic epoxy resin models and a circular polariscope were used to record the isochromatic fringes. After the stress distribution around the implant and tooth was observed, the results were as follows ; 1. In threaded type implants, stress concentrated patterns were observed at the neck either vertical or 25 degree lateral force. 2. The stress concentrated patterns were observed at the tooth apical portion and neck portions of the implant and tooth when a threaded implant was connected with the tooth by either a rigid or non-rigid connector. More force was generated at the tooth neck portion by a rigid connector and more force at the implant neck portion by a non-rigid connector. 3. The stress concentrated patterns were observed at the apical portion of the implant and tooth when a cylindrical type ,implant was connected with the tooth either by a rigid or non-rigid connector. More force was generated at the tooth apical portion by a rigid connector and more force at the neck portion of the tooth and implant by a non-rigid connector. 4. The stress around the tooth was more equally distributed in a threaded type implant than in a cylindrical implant when the tooth was connected with either a rigid or non-rigid connector. 5. The stress around a threaded type implant was progressively more equally distributed in the following order : 1) when used a single implant, 2) a non-rigid connection with the implant and tooth, 3) a rigid connection with the implant and tooth, 4) a rigid connection with two implant fixtures.

  • PDF

Influence of microthread design on marginal cortical bone strain developement: A finite element analysis (임플란트 경부 미세나사 디자인이 치밀골의 스트레인에 미치는 영향)

  • Chun, Seung-Geun;Cho, Jin-Hyun;Jo, Kwang-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.215-223
    • /
    • 2010
  • Purpose: The present study was aimed to evaluate the level of cortical bone strain during the placement of an implant. The primary concern was to investigate if the extent of overloading area near the marginal bone could be affected by microthread fabricated at the cervical 1/3 of an implant. Materials and methods: Three dimensional finite element analysis was used to simulate the insertion of 3 implants. Control model was $4.1{\times}10$ mm implant (Submerged model, Dentis Co,, Daegu, Korea) equipped with a main thread only. Type I was with main thread and microthread, and Type II had similar thread pattern but was of tapered body. A PC-based finite element software (DEFORM 3D ver 5, SFTC, Columbus, OH, USA) was used to calculate a total of 3,600 steps of analysis, which simulated the whole insertion. Results: Results showed that the strain field in the marginal bone within 1 mm of the implant wall was higher than 4,000 micro-strain in the control model. The size of bone overloading was 1-1.5 mm in Type I, and greater than 2 mm in Type II implants. Conclusion: These results indicate that the marginal bone may be at the risk of resorption on receiving the implant for all 3 implant models studied. Yet, the risk was greater for Type I and Type II implants, which had microthread at the cervical 1/3.