• Title/Summary/Keyword: 결함 트리거

Search Result 73, Processing Time 0.026 seconds

Development of A High-Speed Digital Maximum Selector Circuit With Internal Trigger-Signal Generator (내부 트리거 발생회로를 이용한 고속의 디지털 Maximum Selector 회로의 설계)

  • Yoon, Myung-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.2
    • /
    • pp.55-60
    • /
    • 2011
  • Most of neural network chips use an analog-type maximum selector circuit (MS). As the increase of integration level, the analog MS has difficulties in achieving sufficient resolution. Contrary, the digital-type MS is easy to get high resolution but slower than its analog counterparts. A new high-speed digital MS circuit called MSIT (Maximum Selector with Internal Trigger-signal) is presented in this paper. The MSIT has been designed to achieves both the high reliability by using trigger-signals and high speed by removing the unnecessary waiting times. The response time of MSIT is 3.4ns for 32 data with 10-bit resolution in the simulation with 1.2V, $0.13{\mu}m$-process model parameters, which is much faster than its analog counterparts. It shows that digital MS circuits like MSIT can achieve higher speed as well as higher resolution than analog MS circuits.

A Study on the Electrical Characteristic of SCR-based Dual-Directional ESD Protection Circuit According to Change of Design Parameters (SCR 기반 양방향성 ESD보호회로의 설계 변수 변화에 따른 전기적 특성의 관한 연구)

  • Kim, Hyun-Young;Lee, Chung-Kwang;Nam, Jong-Ho;Kwak, Jae-Chang;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.265-270
    • /
    • 2015
  • In this paper, we proposed a dual-directional SCR (silicon-controlled rectifier) based ESD (electrostatic discharge) protection circuit. In comparison with conventional SCR, this ESD protection circuit can provide an effective protection against ESD pulses in the two opposite directions, so the ESD protection circuit can be discharged in two opposite direction. The proposed circuit has a higher holding voltage characteristic than conventional SCR. These characteristic enable to have latch-up immunity under normal operating conditions as well as superior full chip ESD protection. it was analyzed to figure out electrical characteristics in term of individual design parameters. They are investigated by using the Synopsys TCAD simulator. In the simulation results, it has trigger voltage of 6.5V and holding voltage increased with different design parameters. The holding voltage of the proposed circuit changes from 2.1V to 6.3V and the proposed circuit has symmetrical I-V characteristic for positive and negative ESD pulse.

Analysis of SCR, MVSCR, LVTSCR With I-V Characteristic and Turn-On-Time (SCR, MVSCR, LVTSCR의 Turn-on time 및 전기적 특성에 관한 연구)

  • Lee, Joo-Young
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.295-298
    • /
    • 2016
  • In this paper, we analysed the properties of the conventional ESD protection devices such as SCR, MVSCR, LVTSCR. The electrical characteristics and the turn-on time properties are simulated by Synopsys T-CAD simulator. As the results, the devices have the holding voltages between 2V and 3V, and the trigger voltage of about 20V with SCR, of about 12V with MVSCR, of about 9V with LVTSCR. The results of the simulation for the turn-on time properties are 2.8ns of SCR, 2.2ns of MVSCR, 2.0ns of LVTSCR. Thus, we prove that LVTSCR has the shortest turn-on time. However, the second breakdown currents(It2) of the devices are 7.7A of SCR, 5.5A of MVSCR, 4A of LVTSCR. This different properties have to be adapted by the operation voltages for I/O Clamps.

-On Acupoints & Trigger Points- Muscle fatigue evaluation using the Micro-electromagnetic stimulation (-경혈 및 트리거 포인트에서- 미약 자기장을 이용한 근피로 회복 평가)

  • Kim, Soo-Byung;Lee, Na-Ra;Shim, Tae-Kyu;Lee, Seung-Wook;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.5
    • /
    • pp.1231-1239
    • /
    • 2010
  • The aim of this study was developing the non-invasive focused magnetic stimulation system(NI_FMSS) that can stimulates acupoints which are small parts and knotted muscular tissues. To evaluate pain treatment effect of the NI_FMSS, we caused muscle fatigue to 25 subjects in biceps of the arm. Then, we stimulated acupoints(trigger points) HT2 using low frequency stimulator(10 subjects) and NI_FMSS(10 subjects). The other 5 subjects had not been stimulated. We analyzed muscle fatigue recovery with median frequency, RMS and median power in frequency domain for 5 days. We checked the magnetic stimulation effect on acupoint by evaluation of muscle fatigue recovery. Therefore, we identified that the NI_FMSS was more efficient system to relieve muscle pain than electric-stimulation system.

AP-Initiated Flow Redirection Mechanism for AP Load Balancing in WLAN Environments (무선랜 환경에서 AP 로드 밸런싱을 위한 AP-개시 플로우 리다이렉션 메커니즘)

  • Kim, Mi-Hui;Chae, Ki-Joon
    • Journal of Internet Computing and Services
    • /
    • v.10 no.2
    • /
    • pp.65-73
    • /
    • 2009
  • IEEE802.11 Wireless LAN(WLAN) is being widely used in public space such as airport, and increases the networking boundary in campus and enterprise, and it has lastly attracted considerable attention for mesh network and converged network with other 3G mobile communication networks. In WLAN, load balancing among Access Points(AP) is an important issue for efficient resource management or supporting the Quality of Service(QoS) of traffic, but most researches focused on the AP selection in network entry or roaming of Stations(STA). In this paper, we propose an AP-Initiated Flow Redirection(FR) for AP load balancing by monitoring AP's availability in the true sense. When the AP's resource becomes almost saturated, that is used more than a specific threshold, the AP queries the roaming possible neighbor APs about their availability and calculates the distribution of traffic load with statistical methods such as entropy or chi-square. Finally, the AP decides flows and new APs for redirection and performs it. Our simulation results show that our FR mechanism increases the performance in the various views.

  • PDF

Design of Low-Power High-Performance Analog Circuits for UHF Band RFID Tags (UHF대역 RFID 태그를 위한 저전력 고성능 아날로그 회로 설계)

  • Shim, Hyun-Chul;Cha, Chung-Hyeon;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.130-136
    • /
    • 2008
  • This paper describes a low-power high-performance analog front-end block for $UHF(860{\sim}960MHz)$ band RFID tag chips. It satisfies ISO/IEC 18000-6 type C(EPCgolbal class1. generation2.) and includes a memory block for test. For reducing power consumption, it operates with a internally generated power supply of 1V. An ASK demodulator using a current-mode schmitt trigger is proposed and designed. The proposed demodulator has an error rate as low as 0.014%. It is designed using a 0.18um CMOS technology. The simulation results show that the designed circuit can operate properly with an input as low as $0.2V_{peak}$ and consumes $2.63{\mu}A$. The chip size is $0.12mm^2$

A Study on the Strategy of Securing the Archival Budget through Qualitative Research Method (기록전문직의 기록관리 사업예산 확보 전략 연구)

  • Suh, Hwayul;Yim, Jinhee
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.22 no.3
    • /
    • pp.55-81
    • /
    • 2022
  • The purpose of this study is to explore a budget-securing strategy to enable archival professionals in public institutions to continuously secure the budget for records management projects. This study is an analysis of the results of in-depth interviews with 14 archival professionals who have worked for public institutions and secured budgets for records management projects. As a result of the analysis, 4 upper categories and 10 categories are extracted as factors influencing budget securement. The top four categories are the job environment of archival professionals, umbrella organization and organizational culture, business and budget characteristics, and system and social environment. As the budget-securing strategy for archival professionals, a total of 3 categories and 13 strategic codes are derived. The three categories are utilizing individual-centered competencies, establishing organization-centered relationships, and finding external environment-centered triggers. This study emphasized the perspective of archival professionals and suggested implications such as the role of archival professionals and the direction of improvement in securing budgets.

Design of the Capacitor Discharge Ignition System (용량방전점화장치의 설계)

  • 박송배;김영길
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.13 no.2
    • /
    • pp.5-13
    • /
    • 1976
  • An analytical and experimental design procedure is described for the Capacitor Discharge Ignition (CDI) System with a view to fuel saving ann reduction of gas exhaustion and maintenance need. Specifically, the input and output voltage and current of a given ignition coil were calculated by using a simplified circuit model for the discharging system. The results were compared with the experimental results, from which ratings of the charging capacitor, the SCR and the diodes and the required output valtage of the DC.DC converter were determined so as to satisfy the optimum ignition conditions. Protection circuits for excessive dv/dt and di/dt for the SCR were also analyzed and the results were compared with the observed results, which facilitate selection of the SCR and design of the protection circuit and the trigger circuit. Also, design of the DC.DC converter was simplified based on the analysis and experimental results of the behavior of the converter, An experimental, yet practical CDI system was built, which showed satisfactory performance in the laboratory and field tests. The results were also reported.

  • PDF

Experimental and Numerical Studies on Composite Tubes for the Energy Absorber of High-speed Train (복합재 튜브를 이용한 고속 열차의 에너지 흡수장치에 대한 실험 및 수치해석 연구)

  • Nguyen, Cao-Son;Jang, Hong-Kyu;Shin, Jae-Hwan;Son, Yu-Na;Kim, Chun-Gon
    • Composites Research
    • /
    • v.24 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • This paper presents an experimental and numerical study on composite tubes for the energy absorber of the high-speed train. The purpose of the experimental study is to find out which lay-up is the best lay-up for the energy absorber. Four lay-ups were tested using quasi static method: $[0/45/90/-45]_4$, $[0]_{16}$, $[0/90]_8$, $[0/30/-30]_5$. Two triggering methods were used to create initial damage and guarantee the progressive collapse mode: bevel edge and notch edge. As a result, $[0/45/90/-45]_4$ lay-up was find out the best lay-up among the laminates being tested. In the numerical study, a parametric analysis was done to find out the most proper way to simulate the quasi static test of a composite tube using LS-DYNA program. A single composite tube was modeled to be crashed by a moving wall. Comparison between simulation and experiment was done. Reasonable agreement between experiment and analysis was obtained. Dealing with parameter TFAIL and the mass scaling factor, this parametric study shows the ability and the limitation of LS-DYNA in modeling the quasi static test for the composite tube.

Development of the PC Based Color Fish Finder (퍼스널 컴퓨터를 이용한 칼라 어군탐지기의 개발에 관한 연구)

  • 신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.3
    • /
    • pp.247-255
    • /
    • 1995
  • This paper describes a personal computer(PC) based color fish finder to improve some problem of the commercial one. The commercial fish finder has no function of the echo data logging and replaying. The authors developed two types of the PC based color fish finder. One is a master type composed of a PC, a digital input-output board, and analog to digital converting (A/D) board and an ultrasonic transceiver unit, the other is a slave type composed of a PC and an A/D board. To test the performances of the master type experiments were carried out in air and in a water tank. It is found that the designed master type fish finder displays very well an eight-colored echogram by one dot resolution to the left side of the PC monitor. Also, the depth of echo signal was corresponds very well to the range from the transducer to a target. The sampling interval of echo signal is about 0.1m and the time of A/D conversion is 30 $\mu$sec. On the other hand, to test the performances of the slave type a raw data of echo signals from a data logger was supplied directly or via RF transceivers to the slave type one. From this experiment, it is confirmed the slave type is useful to replay the echo signal from the data logger or a telesounder.

  • PDF