• Title/Summary/Keyword: 건의

Search Result 8,953, Processing Time 0.042 seconds

Epidemiological Characterization of Influenza Virus Isolated from Acute Respiratory Illness in Busan, 2004-2005 (최근 2년간 부산지역에서 급성호흡기 환자로부터 분리한 인플루엔자바이러스의 유행 양상)

  • Cho, Kyung-Soon;Park, Sun-Mee;Kim, Seang-Joon;Jung, Myung-Ju;Lee, Joo-Yeon;Kang, Chun
    • Korean Journal of Microbiology
    • /
    • v.43 no.3
    • /
    • pp.173-178
    • /
    • 2007
  • The occurrence of acute respiratory infections caused by the influenza virus are particularly high during the winter season in Busan, Korea. In 2004 and 2005, a study of the rate of occurrences of the influenza virus was conducted. The results reveal that in 2004, of the 1,869 people with an acute respiratory infection that 154 (8.2%) people were infected by the influenza virus. In 2005, of the 1,579 people infected with an acute respiratory infection that 19 people (1.2%) were infected with the influenza virus. The study shows a decrease in the numbers of an influenza virus infection from 2004 to 2005. Data was collected by inspecting throat swabs and nasal discharge from those with an acute respiratory infection. Further inspection of the throat swab and nasal discharge from the infected individuals during 2004 and 2005 study show the occurrence of the different types of influenza virus in the population: 6 cases (3.5%) of influenza type A/H1N1, 129 cases (74.5%) of A/H3N2, and 38 cases (22.0%) of type B. The study conducted in 2004 and 2005 reveal that children between the ages of two and five were more likely to be infected than any other age group. In the study, about 62.2% of the infected individuals were between two and five years old. The detection rates between males and females are similar. However, it is notable that females are slightly more likely to develop an acute respiratory infection caused by the influence virus compared to their male counterparts.

A Study on Safety of Ready-to-eat Compound Foods with a By-products of Meat as the Base (식육부산물을 주재료로한 복합즉석조리식품의 안전성 연구)

  • Song, Sung-Min;Lee, Gil-Bong;Kim, Myeong-Hee;Jeung, Ji-Yeol;Hwang, Won-Mu;Yun, Ga-Ri;Kim, Sun-Hoi;Go, Jong-Myeung;Kim, Yong-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.2
    • /
    • pp.82-87
    • /
    • 2007
  • This research was performed to investigate chemical and microbiological hazards of Ready-to-eat(RTE) compound foods which uses the by-product of meat. For this experiment, 51 samples of RTE compound foods in by-product of meat distributed in Incheon from January to December 2006 were tested. The contents of heavy metals in the main ingredient of RTE compound foods were in the range of $0.073{\sim}0.112ppm$ for lead (Pb), $0.006{\sim}0.013ppm$ for cadmium (Cd) and $0.746{\sim}0.978ppb$ for mercury (Hg). The concentrations of residual ABS(alkyl benzene sulfate) in the small intestine which is a main ingredient of Gopchang-casserole were $$0.8ppm{\sim}57.6ppm$ (Ave. 10.3ppm). Staphylococcus aureus was isolated from 11 samples (21.6%) among 51 main ingredients of RTE compound foods. The isolation rates of Salmonella spp. and Clostridium perfringens were 2.0% (1/51) and 5.9% (2/51), respectively. By types of main ingredient, the small intestine was showed the highest isolation rate as 35.3% (12/34), ham and the sausage which are main ingredients of the Budae-pot stew were 25% (2/8) and other meat products were 20% (1/5). Food poisoning bacteria was not found in the blood of pig which is a main ingredient of the Sunji-pot stew. 28.4% (27/95) of sauce included in each RTE compound foods were coliform bacteria positive. Pesticide residues were found in four of 45 vegetables which are the additional ingredient of RTE compound foods. The concentrations of pesticide were chlorothalonil 2.8 ppm, EPN 10.3 ppm, chlorpyrifos 0.4ppm and indoxacarb 0.7ppm. In 33 bean sprout samples, captan and carbendazim were not detected.

Analysis and Safety Assessment of Antioxidants Migrated from Polyethylene and Polypropylene Food Packaging Materials into Food Simulants (폴리에틸렌 및 폴리프로필렌 기구·용기·포장 유래 산화방지제 분석 및 안전성평가)

  • Choi, Heeju;Choi, Jae Chun;Bae, In-Ae;Park, Se-Jong;Kim, MeeKyung
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.424-433
    • /
    • 2017
  • Antioxidants are used in the manufacturing of commercial food packages made of polyolefin plastic such as polyethylene and polypropylene for the purpose to delay the oxidation reaction of the polymer due to oxygen or traces of ozone in the atmosphere. Additives in plastics may be migrated from the packaging materials into foods, thereby presenting a potential health risk to the consumer. Therefore, it is necessary to determine migration level of antioxidants from food packaging materials to foodstuffs in order to take proactive management. In this study, we have developed a method for the analysis of 10 antioxidants, which are butylated hydroxyanisole (BHA), butylated hydroxytoluene (BHT), Cyanox 2246, 425 and 1790, Irgafos 168, and Irganox 1010, 1330, 3114 and 1076, migrated from the food packaging materials into four food simulants for aqueous, acidic, alcoholic and fatty foods. The antioxidants were determined by reversed-phase high-performance liquid chromatograph-ultraviolet detector with 276 nm after solid-phase extraction with a hydrophilic-lipophilic balance (HLB) cartridge or dilution with isopropanol. The analytical method showed a good linearity of coefficient ($R^2{\geq}0.99$), limits of detection (0.11~0.41 mg/L), and limits of quantification (0.34~1.24 mg/L). The recoveries of antioxidants spiked to four food simulants ranged from 71.3% to 109.4%. The migrated antioxidants in this study were within the safety levels that resulted from the safety assessment by the estimated daily intake to the tolerable daily intake.

Radiotherapy Incidents Analysis Based on ROSIS: Tendency and Frequency (ROSIS 자료 기반 방사선 사고 사례 분석 : 경향과 빈도)

  • Koo, Jihye;Yoon, MyongGeun;Chung, Won Kuu;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.298-303
    • /
    • 2014
  • In this study, we examine the trends and types of incidents frequently occur during radiation therapy by using the data from the radiation oncology safety information system (ROSIS), according to discovery method explores the development direction of future research accident cause factor control method. This study was carried out analysis of incident data in ROSIS nearly 1163 cases in last 11 years from 2003 to 2013. We categorized into treatment methods, found the time, discoverer of occupations and finding ways to analyze the data. Then, we calculate the percentage and the classification for each item. About 1163 cases of incident cases including the near miss cases, external radiation therapy, brachytherapy and other were 97%, 2% and 1%. In the case was improperly planned dose delivery was 44% (497 cases) which 429 cases (86%) was found before 3 fractions and 13 cases were found after 11 fractions. The investigation was found to be distributed in various a found times. Approximately 42% of found time was during treatment and 29% of patients were found the problem during inspection chart. Occupation to discover the most radiation accidents was the radiation therapist (53%) who works in treatment room. Among 1163 incidence cases, 24% cases were found the accident before the treatment, therefore most of accident were found after of during the treatment (70%, 813 cases). This trend is acquired through ROSIS analysis, is expected to be not significantly different in the case of Korea, so it is necessary more diverse and systematic research for the prevention and early detection by using the ROSIS data.

Analysis and Uncertainty Estimation of Zearalenone in Cereal-Based Products by LC-MS/MS (LC-MS/MS를 이용한 곡류가공품의 제랄레논 분석과 측정불확도 추정)

  • Choi, Eun Jung;Kang, Sung Tae;Jung, So Young;Shin, Jae Min;Jang, Min Su;Lee, Sang Me;Kim, Jung Hun;Chae, Young Zoo
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.6
    • /
    • pp.658-665
    • /
    • 2012
  • A survey of zearalenone contamination was conducted on cereal-based products by using an immunoaffinity column with LC-MS/MS. The calibration curve showed good lineality, with correlation coefficients ($R^2$) of 0.999 in the concentration range from 1 to 250 ng/mL. The limits of detection and quantification were approximately $0.3{\mu}g/kg$ and $1.0{\mu}g/kg$, respectively. The recoveries in the barley tea, Misutgaru and snack ranged from 73.6-107.8%. Zearalenone was detected in 10 samples (11.2% incidence). The highest zearalenone contamination level was $29.7{\mu}g/kg$ in the Misutgaru. This survey was conducted with uncertainty of measurement. The expanded uncertainty for zearalenone was estimated to be $44.9{\pm}5.0{\mu}g/kg$ (k=2, 95% confidence level) and $128.7{\pm}7.9{\mu}g/kg$ (k=2, 95% confidence level) for barley tea, $30.7{\pm}5.8{\mu}g/kg$ (k=2, 95% confidence level) and $173.7{\pm}14.9{\mu}g/kg$ (k=2.26, 95% confidence level) for Misutgaru, and $37.2{\pm}7.4{\mu}g/kg$ (k=2.31, 95% confidence level) and $151.0{\pm}10.4{\mu}g/kg$ (k=2, 95% confidence level) snack at the level of $41.7{\mu}g/kg$ and $166.7{\mu}g/kg$, respectively.

Evaluation of IH-1000 for Automated ABO-Rh Typing and Irregular Antibody Screening (ABO 및 RhD 혈액형 검사와 비예기항체 선별검사를 위한 자동화장비 IH-1000의 평가)

  • Park, Youngchun;Lim, Jinsook;Ko, Younghuyn;Kwon, Kyechul;Koo, Sunhoe;Kim, Jimyung
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.127-135
    • /
    • 2012
  • Background: Despite modern advances in laboratory automated medicine, work-process in the blood bank is still handled manually. Several automated immunohematological instruments have been developed and are available in the market. The IH-1000 (Bio-Rad Laboratories, Hercules, CA, USA), a fully automated instrument for immunohematology, was recently introduced. In this study, we evaluated the performance of the IH-1000 for ABO/Rh typing and irregular antibody screening. Methods: In October 2011, a total of 373 blood samples for ABO/Rh typing and 303 cases for unexpected antibody screening were collected. The IH-1000 was compared to the manual tube and slide methods for ABO/Rh typing and to the microcolumn agglutination method (DiaMed-ID system) for antibody screening. Results: For ABO/Rh typing, concordance rate was 100%. For unexpected antibody screening, positive results for both column agglutination and IH-1000 were observed in 10 cases (four cases of anti-E and c, three of anti-E, one of anti-D, one of anti-M, and one of anti-Xg) and negative results for both were observed in 289 cases. The concordance rate between IH-1000 and column agglutination was 98.7%. Sensitivity and specificity were 90.9% and 99.3%, respectively. Conclusion: The automated IH-1000 showed good correlation with the manual tube and slide methods and the microcolumn agglutination method for ABO-RhD typing and irregular antibody screening. The IH-1000 can be used for routine pre-transfusion testing in the blood bank.

Method Development for Determination of Chlorogenic Acid and Arbutin Contents in Fruits by UHPLC-MS/MS (UHPLC-MS/MS를 이용한 과일류 중 클로로젠산 및 알부틴 동시분석법 개발)

  • Choi, Young-Ju;Jeon, Jong-Sup;Kim, Woon-Ho;Jung, You-Jung;Ryu, Ji-Eun;Choi, Jong-Chul;Chae, Kyung-Suk;Lee, Jin-Hee;Do, Young-Sook;Park, Young-Bae;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.5
    • /
    • pp.413-420
    • /
    • 2019
  • In this study, a sample preparation method and a simultaneous determination method by ultra-high performance liquid chromatography coupled with tandem mass spectrometry for 9 isomers of chlorogenic acid and arbutin in fruits were developed. The samples were extracted using 90% methanol (pH 3.0), with the solutions being shaken and then sonicated for 10 min each. After centrifugation at 4,000 rpm for 10 min, the extraction was concentrated under a vacuum at $40^{\circ}C$ using a vacuum evaporator. The residue was dissolved in 5 mL of 5% methanol and filtered through a $0.45{\mu}m$ membrane before UHPLC-MS/MS analysis. The separations were performed on a C18 column with gradient elution of water (containing 0.1% formic acid) and methanol (containing 0.1% formic acid). The specificity, linearity, limit of detection, limit of quantification, accuracy, and precision of the proposed methods were also evaluated.

Monitoring and Risk Assessment of Pesticide Residues in School Foodservice Agricultural Products in Gwangju Metropolitan Area (광주광역시 학교급식 농산물의 잔류농약 모니터링 및 위해평가)

  • Kim, Jinhee;Lee, Davin;Lee, Mingyou;Ryu, Keunyoung;Kim, Taesun;Gang, Gyungri;Seo, Kyewon;Kim, Jung-Beom
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.283-289
    • /
    • 2019
  • This study was performed to monitor the residual pesticides in agricultural products used in school foodservice in the Gwangju metropolitan area. Risk assessment was also carried out based on the amount of agricultural products consumed. A total of 320 agricultural products supplied to schools in Gwangju were analyzed from 2015 to 2017. The pre-treatment and residual pesticide analysis of these products was conducted in accordance with the second method for multi-residue analysis of pesticides in the Korean food code. The hazard index was calculated by dividing the estimated daily intake (EDI) of pesticides by the acceptable daily intake (ADI). The linearity correlation coefficient for the calibration curve was 0.9923 to 1.0000, LOD 0.004 to 0.019 mg/kg, LOQ 0.012 to 0.057 mg/kg, and recovery was 79.1 to 100.2%. Residual pesticides were detected in 18 (5.6%) of 320 agricultural products used for school foodservice, and one sample of sweet potato stem (0.3%) exceeded the maximum residual limit (MRL). The detection frequency for chili peppers and bell peppers was higher than that for other agricultural products. The frequently-detected pesticides were boscalid and acetamiprid. These results showed that residual pesticide management is needed for chili pepper, bell pepper and sweet potato stem among agricultural products supplied to schools. The hazard index of bifenthrin in sweet potato stem showed the highest (64.18%), and the other pesticides were 0.03-8.23%. These results indicated that agricultural products supplied to schools in Gwangju were safe for consumption. To minimize the intake of residual pesticides, it is necessary to not only thoroughly wash agricultural products but to also ensure the expanded supply of products that are pesticide-free.

Simultaneous Multicomponent Analysis of Preservatives in Cosmetics by Gas Chromatography (GC를 이용한 화장품 살균·보존제의 다성분 동시분석법)

  • Cho, Sang Hun;Jung, Hong Rae;Kim, Young Sug;Kim, Yang Hee;Park, Eun Mi;Shin, Sang Woon;Eum, Kyoung Suk;Hong, Se Ra;Kang, Hyo Jeong;Yoon, Mi Hye
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.1
    • /
    • pp.69-75
    • /
    • 2019
  • Preservatives of cosmetics is managed by positive list in Korea. Positive list requires a proper quantitative analysis method, but the analysis method is still insufficient. In this study, gas chromatography with flame ionization detector was used to simultaneously analyze 14 preservatives in cosmetics. As a result of method validation, the specificity was confirmed by the calibration curves of 14 preservatives showing good linearity correlation coefficient of above 0.9997 except dehydroacetic acid (0.9891). The limits of detection (LOD) and quantification (LOQ) of 14 preservatives were 0.0001 mg/mL ~ 0.0039 mg/mL and 0.0003 mg/mL ~ 0.0118 mg/mL, respectively, but they were 0.0204 mg/mL, 0.0617 mg/mL for dehydroacetic acid, respectively. The precision (Repeatability) of the values was less than 1.0%, but 7.1% for dehydroacetic acid. The Accuracy (% recovery) of 14 preservatives in cosmetics showed 96.9% ~ 109.2%. Finally, this method was applied to 50 cosmetics available in market. Results showed that the commonly used preservatives were chlorophene, phenoxyethanol, benzyl alcohol and parabens. However, the amount of the detected preservatives was within maximum allowed limits established by KFDA.

Monitoring of Hazardous Metals Migrated from Home-Cooking Utensils (홈베이킹 조리기구에서 용출되는 유해금속 실태조사)

  • Park, Sung-Hee;Kim, Myung-Gil;Son, Mi-Hui;Seo, Mi-Young;Jang, Mi-Kyung;Ku, Eun-Jung;Chae, Sun-Young;Park, Yong-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.3
    • /
    • pp.264-270
    • /
    • 2021
  • In this study we investigated the elution level of lead (Pb), cadmium (Cd), arsenic (As), zinc (Zn), nickel (Ni), antimony (Sb), germanium (Ge), aluminum (Al) and hexavalent chromium (Cr6+) from 69 home-cooking utensils into a food stimulants. The results of migration testing according to the Korea standards and specifications for utensils, containers and packages showed values the allowable migrantion limits. Al was detected in all 7 utensil materials with the average concentration ranging from 0.002-5.989 mg/L. According to the migration conditions for (180℃, 30 min), the average concentration of Al in paper was 7.2 times higher than 25℃, 10 min (P<0.05). The results of migration testing at 180℃, 30 min were also below the allowable migrantion limits. When comparing with the provisional tolerable weekly intake (PTWI) of Al, the estimated weekly intakes (EWI) accounted for 0.000-0.045% for Al.