• Title/Summary/Keyword: 건물에너지사용특성

Search Result 72, Processing Time 0.03 seconds

Multi-family Housing Complex Breakdown Structure for Decision Making on Rehabilitation (노후 공동주택 개선여부 의사결정을 위한 공동주택 분류체계 개발)

  • Hong, Tae-Hoon;Kim, Hyun-Joong;Koo, Choong-Wan;Park, Sung-Ki
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.6
    • /
    • pp.101-109
    • /
    • 2011
  • As climate change is becoming the main issue, various efforts are focused on saving building energy consumption both at home and abroad. In particular, it is very important to save energy by maintenance, repair and rehabilitation of existing multi-family housing complex, because energy consumption in residential buildings is not only forming a great part of gross energy consumption in Korea but the number of deteriorated complexes is also sharply increasing. However, energy saving is not considered as a main factor in decision making on rehabilitation project. Also, any supporting tool is not appropriately prepared in existing process. As the first step for development of decision support system on rehabilitation, this paper developed a breakdown structure, which makes clusters of multi-family housing complexes. Decision tree, one of data mining methods, was used to make clusters based on the characteristics and energy consumption data of multi-family housing complexes. Energy saving and CO2 reduction will be maximized by considering energy consumption during rehabilitation process of multi-family housing complex, based on these results and following research.

Energy Efficient Lighting Control Facilities Related to Daylight Levels (주광(晝光) 대등형 가변조명(可變照明) 제어설비의 적용 및 통합성능)

  • Kim, Jeong-Tai;Kim, Gon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.8-15
    • /
    • 2006
  • To reduce costs and address other practical concern related to architectural lighting, we have been involved in various aspects of advanced daylighting design and control. If we look toward future building trends, we see that the advanced has already successfully deployed such complex lighting control systems. This paper takes a broad view of what advanced manufacturers have done to develop energy efficient lighting control technologies such as sensors, lumen maintenance, time of day scheduling, peak demand reduction and so forth. First of all strategies, daylighting controls would also need to be commissioned to respond to the specific daylighting signature of the zone. To translate the daylight in term of the amount of energy savings, an electric lighting system is designed and automatic on-off control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. The lighting analysis program, Lumen-Micro predicts the optimal layout of conventional fluorescent and incandescent lighting fixtures to meet the designed lighting level and calculates unit power density, which translates the demanded amount of lighting energy.

Research on Earth Leakage Circuit Breaker for DC-Based Green Home (그린 스마트 홈의 직류배전용 누전 차단기에 관한 연구)

  • Kim, Hye-Jin;Baek, Jongbok;Seo, Gab-Su;Choi, Kyusik;Bae, Hyunsu;Cho, Bohyung
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.76-77
    • /
    • 2010
  • 최근 가정이나 산업용 건물에서 컴퓨터, TV, LED 조명 등 제품 내에서 직류를 사용하는 부하가 증가함에 따라 직류배전 도입에 대한 요구가 증가하고 있다. 직류배전을 통해 가전기기 내부의 전력변환단계를 줄임으로써 에너지 효율을 높일 수 있다. 또한, 직류기반의 태양광발전, 배터리 등의 배전 연계가 용이해진다. 하지만 직류배전의 도입을 위해서는 안전성을 위한 직류 배전용 누전차단기, 배전용 차단기의 개발이 필요하다. 본 논문에서는 상용 교류용 누전차단기의 직류배전 적용 가능성을 알아보고 직류배전에서의 누전차단기 동작특성을 분석한다.

  • PDF

The Study to Suggest a Methods to Evaluate Heating and Cooling Energy Performance based on Daily Life (실생활기반 냉난방에너지 성능평가 방법 제안 연구)

  • Jeon, Gangmin;Lee, Heangwoo;Kim, Yongseong
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.5 no.3
    • /
    • pp.291-299
    • /
    • 2015
  • With recent surge of attention to heating and air conditioning energy consumption, the need for evaluating performance of heating and air conditioning energy is also on the rise. This research aims to propose daily-life based evaluation method as an alternative to existing one, as well as to apply the method in real life to prove its validity. The results are as following. 1) I studied temperatures preferred by persons indoors and appropriate level of temperature, and the results show that properties of such persons such as age is directly linked with pleasantness of the room, but the issue lies with the fact that such properties are not considered in existing performance evaluation of heating and air conditioning. 2) Daily life based evaluation proposed herein reflects such properties of persons indoors. It controls heating / air conditioning devices installed in the test bed with the same size as a real life room to get quantitative and visual performances in our daily life as well as simple temperature information. 3) To verify validity of daily life based evaluation, I conducted different evaluation sessions with and without a blind and also based on ages of persons indoors. Results based on properties of persons showed difference of 77.6%, leading to effective analysis of energy consumption pattern by heating / air conditioning devices. This research takes significance in that it comes with a new performance evaluation method based on real life, and I gather that further studies are required to develop more multilateral performance evaluation in order to verify and improve technology for reduction of energy consumption.

An Analysis on Current Status of Certification for Green Building Revitalization in School - Focused on the School Located in Gyeonggi-do Province - (학교시설의 녹색건축 활성화를 위한 인증현황 분석 연구 - 경기도 학교시설을 중심으로 -)

  • Kim, Jang-Young;Kim, Sung-Joong;Lee, Seung-Min
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.14 no.3
    • /
    • pp.9-17
    • /
    • 2015
  • In this paper, there are several analysis on G-SEED, Building Energy Efficiency Rating System, Energy Performance Index, Energy Saving Plan about how they are applied by classification and planning standard. The analysis result found out that G-SEED has low select percentage by having difficulties to managing and additional cost when the each class is selected. And also, Building Energy Efficiency Rating System in school is planed in comparably simple design and similar size and also mostly uses high efficient machines, which was in high lever comparing to the system in facilities in other uses. In the case of EPI, there are differences on acquiring grades by each region. Especially, Gyung-gi region has a low grade on architecture part comparing to other parts, which seems to acquire more grades by strengthen insulation performance. By the result from the three standards, many facilities has only formal plan to pass the required standard without considering specialities of each buildings, which has a tendency to have a pattern to have a minimum criteria. However, School has a symbolic building which has a obligation to be the base of the aim for growing green energy buildings and green education for students. Therefore, planning with understanding of specialities of the facility, having various and rational evaluation standards from the planning of the building is necessary.

활동형 지진격리 시스템을 적용한 지진격리 교량의 비선형 유한요소해석(S/W:ABAQUS, H/W:CrayC94)

  • 음성우
    • Computational Structural Engineering
    • /
    • v.11 no.1
    • /
    • pp.38-45
    • /
    • 1998
  • 최근 국내외에서 활발히 개발되고 있는 지진격리 시스템은 원자력 발전소, 교량, 중요한 공공건물 등의 지진피해를 최소화하기 이하여 널리 적용되고 있다. 그리고 다른 방법에 비하여 경제성 및 효율성이 우수하기 때문에 관련 연구 및 응용이 활발히 진행되고 있다. 이에 따라 국내외에서 격리시스템의 비선형성과 구조물의 불연속성을 고려한 지진격리 구조물의 해석을 통한 거동을 규명하는 연구가 과거 수년간 활발히 진행되어 왔다. 당사(금호건설)는 상부하중 지지능력과 감쇠능력이 우수한 지진격리장치를 개발하였으며 지진격리장치를 설치한 교량의 지진해석을 수행하여 본 지진격리 시스템의 이론적 성능을 파악하였다. 본 수치해석은 CrayC94에 탑재된 비선형 해석에 뛰어난 것으로 알려진 ABAQU를 이용하였다. 본 지진격리 시스템은 적층고무받침(Laminated Rubber Bearing)과 PTFE 미끄럼받침으로 구성되어 있으며, 적층고무받침은 주로 복원력을 제공하며 PTFE 미끄럼받침은 상부하중을 지지하며 마찰감쇠를 제공하여 에너지를 소산하는 역할을 한다. 본 수치해석에서는 선형스프링과 마찰요소를 이용하여 각각을 모형화하였다. 개발된 지진격리 시스템이 주로 사용될 상판자중이 무거운 다경간 연속 PC Box Girder교를 모델교량으로 선택하여 해석을 수행하였으며 수치해석에 사용된 격리시스템의 사전에 수행된 동특성 실험결과를 활용하였다. 이러한 해석을 통하여 이론적 효율성을 파악할 수 있었다.

  • PDF

Applications and Impact of V2G Technology for Electric Vehicle and Charging Infrastructure (전기자동차와 충전기반시설의 V2G 기술 활용과 영향에 관한 연구)

  • Lee, Sunguk;Park, Byungjoo
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.2
    • /
    • pp.367-373
    • /
    • 2019
  • As the number of Battery Electric Vehicle (BEV) is increasing dramatically Vehicle-to-Grid (V2G) te chnology also has been spotlight from industry and academia recently. With help of V2G technology Battery of EV can play many important roles like as energy storage system (ESS) and electric energy resource in Smart Grid environment. This paper provides comprehensive review of Vehicle-to-Home(V2H), Vehicle-to-Building(V2B) and Vehicle-to-Grid(V2G) technologies. The economical analysis of these technologies is also discussed.

Energy Efficiency Evaluation of Heating and Cooling Systems as Space Program in Renovated Library (도서관의 공간사용 특성에 따른 냉난방설비 리모델링의 경제성 평가)

  • Park, Kang-Hyun;Cha, Jung-Hoon;Kim, Su-Min;Park, Kyung-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.3
    • /
    • pp.205-211
    • /
    • 2012
  • Unlike the previous approaches, we analyzed for economic efficiency of renewed heating and cooling systems as the characteristics of space. The purpose of this study is to analysis the energy consumption and economical efficiency of absorption chillers and EHP systems in renovated library. It is important that equipment selection should be considering energy cost as well as space program. In recently, many EHP systems were installed in the building for reducing the energy cost and for seeking the convenience of individual control. In contrast, though absorption chillers have the disadvantage of a central control, absorption chillers are appropriate for the conditions of the library that needs simultaneous operation. The results by payback period method, show that selection of heating and cooling systems should be consider for space program and the characteristics of space.

Study on safety performance evaluation of stationary SOFC stack (건물용 고체산화물연료전지 스택 안전성능평가 연구)

  • Park, Tae Seong;Lee, Eun Kyung;Lee, Seung Kuk
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.1-12
    • /
    • 2018
  • The code and standards related to fuel cells were analyzed to derive the SOFC(Solid Oxide Fuel Cell) stack safety performance evaluation items and evaluation methode. Safety performance evluation of the SOFC stack was tested by quoting derived test items. The stack used in the test is an anode-supported type 2 Cell stack (Active surface area : 220cm) manufactured by MICO Inc, and SOFC stack safety performance evaluation system used for the test is self-manufactured. We conducted a leakage test, current voltage characteristic test, rated output test, and power response characteristics test. In the safety performance evaluation test, the stack showed no gas leakage, the maximum output and rated output was recorded to 65.6 W(1.41 V, 46.5 A, $422mA/cm^2$), 62.3 W(1.57 V, 40 A, $363mA/cm^2$). In the power response characteristics test verified that the output is kept stable within two seconds. At the maximum load (40 A) and the minimum load (8 A), the output was recorded 62 W and 16W in $750^{\circ}C$. This study will contribute to the universalization and to provide much safe environment of operating the solid oxide fuel cell system.

Development of Summer Leaf Vegetable Crop Energy Model for Rooftop Greenhouse (옥상온실에서의 여름철 엽채류 작물에너지 교환 모델 개발)

  • Cho, Jeong-Hwa;Lee, In-Bok;Lee, Sang-Yeon;Kim, Jun-Gyu;Decano, Cristina;Choi, Young-Bae;Lee, Min-Hyung;Jeong, Hyo-Hyeog;Jeong, Deuk-Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.246-254
    • /
    • 2022
  • Domestic facility agriculture grows rapidly, such as modernization and large-scale. And the production scale increases significantly compared to the area, accounting for about 60% of the total agricultural production. Greenhouses require energy input to create an appropriate environment for stable mass production throughout the year, but the energy load per unit area is large because of low insulation properties. Through the rooftop greenhouse, one of the types of urban agriculture, energy that is not discarded or utilized in the building can be used in the rooftop greenhouse. And the cooling and heating load of the building can be reduced through optimal greenhouse operation. Dynamic energy analysis for various environmental conditions should be preceded for efficient operation of rooftop greenhouses, and about 40% of the solar energy introduced in the greenhouse is energy exchange for crops, so it should be considered essential. A major analysis is needed for each sensible heat and latent heat load by leaf surface temperature and evapotranspiration, dominant in energy flow. Therefore, an experiment was conducted in a rooftop greenhouse located at the Korea Institute of Machinery and Materials to analyze the energy exchange according to the growth stage of crops. A micro-meteorological and nutrient solution environment and growth survey were conducted around the crops. Finally, a regression model of leaf temperature and evapotranspiration according to the growth stage of leafy vegetables was developed, and using this, the dynamic energy model of the rooftop greenhouse considering heat transfer between crops and the surrounding air can be analyzed.