A Study on Metal Oxide based Humidity Sensor with Excellent Humidity Sensing Characteristics (감습특성이 우수한 금속산화물계 습도센서 연구)

  • You, Do-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1982-1988
    • /
    • 2009
  • $TiO_2$ films are fabricated using silk printing method. Heat treatment temperature of films is 600[$^{\circ}C$]. From the analysis of microstructure, grain size of $TiO_2$ films is about $0.2{\sim}0.3[{\mu}m]$. Thickness of films is 30.19[${\mu}m$] and surface uniformity of films is good. From the analysis of crystalline structure, $TiO_2$ films transform anatase phase to rutile phase. Capacitance of films increases according to increase relative humidity and decrease measuring frequency. Hysteresis characteristics of capacitance and impedance are best at 45[%RH] and 75[%RH] respectively. Impedance of films increases according to decrease measuring frequency.

Capacitive Polymer Humidity Sensor (정전용량형 고분자 습도센서)

  • Lim, Chang-Seob;Kwak, Kwang-Jong;Kang, Moon-Sik;Min, Nam-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1511-1513
    • /
    • 2003
  • 본 논문에서는 polyimide를 감습물질로 한 정전용량형 정밀습도센서를 개발하여 실용화한 결과를 보고한다. 유리기판에 제작된 습도센서는 상대습도 11%RH${\sim}$96%RH 범위에서 다음과 같은 특성을 나타내었다. 감도; 0.5689 pF/%RH, 비선형성; 1.5%RH 미만, 히스테리시스; 약 1.5%RH, 감도특성의 온도 의존성; 0.08pF/$^{\circ}C$, 주파수 특성; 10, 100kHz에서 직선적.

  • PDF

Humidity-Sensitive Properties of Vanadium Oxide Thin Films on Sputtering Conditions (스퍼터링 조건에 따른 바나듐 산화막의 감습 특성)

  • Lee, Seung-Chul;Choi, Bok-Gil;Choi, Chang-Gyu;Kwon, Gwang-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.448-451
    • /
    • 2004
  • Vanadium oxides have been widely used in a variety of technological applications such electrochromic devices as infrared detectors and are expected as a material suitable for gas sensing applications. Thin films of Vanadium oxide (VOx) have been deposited by r.f magnetron sputtering under different oxygen partial pressure ratios and substrate temperatures. Humidity-sensitive properties of resistive sensors having interdigitated electrode structure are characterized. Our sensors show good response to humidity over 20%RH to 80%RH. Vanadium oxide films deposited with 0% $O_2$ partial pressure at foot exhibit greater sensitivity to humidity change than others.

  • PDF

The Interdigitated-Type Capacitive Humidity Sensor Using the Thermoset Polyimide (열경화성 폴리이미드를 이용한 빗살전극형 정전용량형 습도센서)

  • Hong, Soung-Wook;Kim, Young-Min;Yoon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.604-609
    • /
    • 2019
  • In this study, we fabricated a capacitive humidity sensor with interdigitated (IDT) electrodes using a thermosetting polyimide as a humidifying material. First, the number of electrodes, thickness, and spacing of the polyimide film were optimized, and a mask was designed and fabricated. The sensor was fabricated on a silicon substrate using semiconductor processing equipment. The area of the sensor was $1.56{\times}1.66mm^2$, and the width of the electrode and the gap between the electrodes were each $3{\mu}m$. The number of electrodes was 166, and the length of an electrode was 1.294 mm for the sensitivity of the sensor. The sensor was then packaged on a PCB for measurement. The sensor was inserted into a chamber environment with a temperature of $25^{\circ}C$ and connected to an LCR meter to measure the change in capacitance at relative humidity (RH) of 20% to 90%, 1 V, and 20 kHz. The results showed a sensitivity of 26fF/%RH, linearity of < ${\pm}2%RH$, and hysteresis of < ${\pm}2.5%RH$.

Capacitive Humidity Sensor Using Reactive Methacrylate Copolymers (반응성이 있는 메타크릴레이트 공중합체를 이용한 정전용량형 습도센서)

  • 공명선;이임렬
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.4
    • /
    • pp.21-27
    • /
    • 2003
  • The copolymers with various composition of methyl methacrylate (MMA), ethyl methacrylate (EMA), methacrylic acid (MA) and hydroxyethyl methacrylate (HEMA) were synthesized for capacitive humidity sensitive materials. The capacitive humidity sensor consisted of a polymethacrylate film coated on both sides with gold electrode. Capacitance versus relative humidity increased with HEMA content in the copolymer. In the case of self-crosslinkable MMA/MA/HEHA= 40/10/10, the average capacitance at 30%RH, 60%RH and 90%RH are 102, 134 and 166 pF, respectively. And also, the hysteresis, temperature cycle and long-term stability were evaluated as a capacitance humidity sensor.

  • PDF

An Experimental Study on the Performance of Heat Pump Assisted Batch Dryer Using HFC134a (HFC134a를 사용한 열펌프 건조기의 성능에 관한 실험적 연구)

  • Kim, Y.J.;Yim, C.S.
    • Solar Energy
    • /
    • v.17 no.2
    • /
    • pp.3-11
    • /
    • 1997
  • In conventional heat and vent dryer, both sensible and latent heat could not be recovered from the exhaust air, but this problem could be solved by introducing a heat pump to a conventional dryer, having a connection with cooling, dehumidifying and heating of heat pump. In this work, HFC134a as a substitute refrigerant of CFC12 adopted in heat pump and a batch type is also introduced. The variables affected on the system performance are holding temperature of a drying chamber, bypass air ratio, degree of superheat and refrigerant flowrate, etc. The moisture contents were decreased curvilinearly in the range of $86{\sim}75%$ on the wet basis. Under the constant drying temperature, the face velocity plays an important role to the drying performance. The COPs are increased in accordance with the air velocity, on the other hand the SMERs are gradually decreased.

  • PDF

The Variation of Response on Humidity in CNT Thin Film by Silane Binders (실란 바인더에 의한 탄소나노튜브 박막의 감습 특성 변화)

  • Kim, Seong-Jeen
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.782-787
    • /
    • 2010
  • Recently the solution-based thin film technology has often been treated in the field of device fabrication owing to easy process and convenience for the development of various semiconductor devices and sensors. We deposited on glass substrate single-walled carbon nanotubes (SWNTs)/silane hybrid thin films by multiple spray-coating which is one of solution-based processes, and examined their electrical response for humidity. Generally silane binders which are often mixed in carbon nanotube (CNT) solution to adhere CNTs to substrate well form easily each own functionalized group on the surface of CNTs after they are hardened by way of the hydrolysis reaction. In this work, we investigated how silane binders (TEOS (tetraethoxy silane), MTMS (methyltrimethoxysilane) and VTMS (vinyltrimethoxysilane)) in CNT thin films make effect to their electrical response on humidity. As the result, we found that the resistance in the samples using TEOS was changed dramatically while it was almost invariant in the samples using MTMS and VTMS for increasing humidity.

Development of a hygroscopic polymer-coated QCM humidity sensor and its characteristics (감습 고분자막이 코팅된 수정미소저울 습도센서 제작 및 특성연구)

  • Kwon, Su-Yong;Kim, Jong-Chul;Choi, Byung-Il;Nham, Hyun-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.395-401
    • /
    • 2005
  • A highly stable quartz crystal microbalance (QCM) that showed a stability of frequencies and exhibited a very low noise level has been developed. The long-term drift was <0.05 Hz/h over a period of 10 h, and the short-term rms (root mean square) noise was <0.015 Hz. Our QCM sensor was used as a humidity sensor employing a poly(methyl methacrylate) (PMMA) polymer film as a hygroscopic layer, which showed good characteristics in the relative humidity (RH) range of $2{\sim}90%$ RH. Comparing the characteristics of the QCM sensor with those of other types of humidity sensors employing PMMA film as a hygroscopic layer, and with other QCM sensors employing other hygroscopic layers is represented.

Studies on the Impedance-Hymidity Characteristics of $TiO_2$-$V_2O_5$ Humidity Sensor ($TiO_2$-$V_2O_5$ 습도감지소자의 감습특성에 관한 연구)

  • 박재환;박순자
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.4
    • /
    • pp.529-535
    • /
    • 1990
  • This paper describes the factors which control the impedance-relative humidity characteristics of the TiO2-V2O5 humidity sensor. To obtain the quantitative relationships between impedance and many manufacturing parameters such as V2O5mol%, the sintering time and temperature, various sets of samples are preared and tested. With changing relative hymidity from 20% to 80%, it is measrued that the corresponding capacitance and impedance from the semicircles which complex impedance plots make. As a result we found that the impedance-relative humidity characteristics are mainly controlled by the doping amount of V2O5 total pore volume and bulk resistence of the elements. We can assume the equivalent circuits of each samples and finally control the sintering time to get a linear humidity impedance response curve which plays an important role in device making. 4mol% V2O5-TiO2 specimen sintered at 90$0^{\circ}C$ for 10min. show liear log(Z) vs. RH characteristics and 10mol% V2O5-TiO2 specimen sintered at the same temp. for 20min. show linear (Z) vs. RH.

  • PDF

Effect of $M_2CO_3$(M=Li, K) Addition on the Humidity Sensitivity of $V_2O_5$-doped $TiO_2$ ($V_2O_5$를 dopant로 한 $TiO_2$의 감습(感濕)에 미치는 $M_2CO_3$(M=Li, K)의 영향(影響))

  • Kang, Yi-Kug;Song, Chang-Yul;Shin, Yeong-Duck
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.427-429
    • /
    • 1995
  • In this paper, the effect of alkaline oxides on the humidity sensitivity of $V_2O_5$(2mol%)-doped $TiO_2$(98mol%) was investigated as functions of $Li_2CO_3$, $K_2CO_3$, additives (x= 0.0 mol%, 1mol%, 2mol%, 5mol%, 10mol%). 1. The porosity and total intrusion volume of sample containing 1, 2, 5mol% $K_2O$ was increased, and then those of 10mol% $K_2O$ was reduced again. 2. The humidity sensitivity of samples containing 1, 2, 5, 10mol% $K_2O$ were good generally. Especially the sample containing 5mol% $K_2O$ were the better. 3. the stability of the humidity sensitivity of samples containing $K_2O$ at low and high temperatures is very good.

  • PDF