• Title/Summary/Keyword: 감쇠 효과

Search Result 632, Processing Time 0.023 seconds

Identification of the Sectional Distribution of Sound Source in a Wide Duct (넓은 덕트 단면내의 음원 분포 규명)

  • Heo, Yong-Ho;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.2
    • /
    • pp.87-93
    • /
    • 2014
  • If one identifies the detailed distribution of pressure and axial velocity at a source plane, the position and strength of major noise sources can be known, and the propagation characteristics in axial direction can be well understood to be used for the low noise design. Conventional techniques are usually limited in considering the constant source characteristics specified on the whole source surface; then, the source activity cannot be known in detail. In this work, a method to estimate the pressure and velocity field distribution on the source surface with high spatial resolution is studied. The matrix formulation including the evanescent modes is given, and the nearfield measurement method is proposed. Validation experiment is conducted on a wide duct system, at which a part of the source plane is excited by an acoustic driver in the absence of airflow. Increasing the number of evanescent modes, the prediction of pressure spectrum becomes further precise, and it has less than -25 dB error with 26 converged evanescent modes within the Helmholtz number range of interest. By using the converged modal amplitudes, the source parameter distribution is restored, and the position of the driver is clearly identified at kR = 1. By applying the regularization technique to the restored result, the unphysical minor peaks at the source plane can be effectively suppressed with the filtering of the over-estimated pure radial modes.

A Study on Vibration Analysis and Estimation of Vibration Damping of Tricone-Bits Drilling Machine (Tricone-Bits 천공장비의 진동 분석 및 진동 거리감쇠 추정에 관한 연구)

  • Cho, Seongkyu;Seo, Sung Chul;Park, Hyung Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.493-499
    • /
    • 2023
  • Recently, with the development of construction machinery, low-vibration construction machine such as Tricone-Bits, which can drill both soil and rock layers and minimize vibration, is being used frequently. However, although many studies have been conducted on the prediction of vibration values for earth augers and pile drivers, the reality is that studies on the effects of vibration on low-vibration drilling equipment are lacking. In this paper, ground vibration values for Tricone-Bits were measured, and a vibration distance damping formula was proposed using this. In addition, after predicting the vibration of the earth auger and pile driver using the previously proposed vibration distance damping formula, the degree of vibration damping for the Tricone-Bits was evaluated by comparing and analyzing it. As a result, the Tricone-Bits showed a vibration reduction effect of 97% and 93% compared to these machine and It will help with management and prediction of the ground vibration effects evaluation on the low-vibration equipment such as Tricone-Bits.

A Shaking Table Test for Equipment Isolation in the NPP (I): Rubber Bearing (원전기기의 면진을 위한 진동대 실험 I : 고무베어링)

  • Kim, Min-Kyu;Choun, Young-Sun;Choi, In-Kil
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.5 s.39
    • /
    • pp.65-77
    • /
    • 2004
  • In this study, the base isolation systems for equipment in the NPP are presented and the responses of each isolation system are investigated. As for the base isolation systems, a natural rubber bearing (NRB) and a high damping rubber bearing (HDRB) are selected. As input motions, artificial time histories enveloping the US NRC RG 1.60 spectrum and the probability-based scenario earthquake spectra developed for the Korean nuclear power plant site as well as a typical near-fault earthquake record are used. Uniaxial, biaxial, and triaxial excitations are conducted with PGAs of 0.1, 0.2 and 0.25g. The reduction of the seismic forces transmitted to the equipment models are determined for different isolation systems and input motions.

A Parabolic Approximation Model for Wave Deformation Combined Refraction, Diffraction, and Breaking (파랑(波浪)의 굴절(屈折), 회절(回折) 및 쇄파변형(碎波變形)에 관한 포물형근사모형(抛物形近似模型))

  • Lee, Dong Soo;Lee, Jong Sup;Park, II Heum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.619-633
    • /
    • 1994
  • A wave deformation model for general purpose combined refraction, diffraction, and breaking is developed in the shallow water. A parabolic approximation equation considered a higher order diffraction term is derived from the previous mild slope equation. A wave energy dissipation term due to bottom friction and breaking is introduced from the turbulence model. The Crank-Nicoloson implicit scheme is used in the numerical calculation, then the solutions are compared with the various hydraulic experiment data in the circular, the elliptic shoal, and the surf zone. The wave height decay in the surf zone is sensitively affected by the incident wave steepness, and the wave height variation around the elliptic shoal is well explained by the non-linear dispersion relation and the wave energy dissipation term. The model is also applied to a field coastal area and reasonable results are obtained.

  • PDF

Development of Analysis Code for Evaluation of Acoustic Stability of Rocket Engine Combustor with Various Designs (로켓엔진 연소기 설계의 음향안정성 평가를 위한 해석코드 개발)

  • Kim, Seong-Ku;Kim, Hong-Jip;Sohn, Chae-Hoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.6
    • /
    • pp.110-116
    • /
    • 2004
  • In this study, a three-dimensional finite-element analysis code has been developed to predict acoustic behaviors in rocket combustion chambers and to quantitatively evaluate acoustic stability margins for various designs with passive stabilization devices such as baffle and acoustic resonators. As a validation case, computations are made for combustion chambers with/without a hub-and-six-blade baffle which are developed in the KSR-III Development Program. Compared with experimental results from ambient acoustic test, the numerical approach reasonably well predicts acoustic pressure responses to acoustic oscillation excitation for both unbaffled and baffled combustion chambers and yields quantitatively good agreement for acoustic damping effects of baffle installation in terms of damping factor ratio and resonant frequency shift.

A Dynamic Condensation for Tall Buildings with Active Tuned Mass Damper (능동 동조질량감쇠의 고층빌딩 해석을 위한 동적압축법)

  • Jung, Yang-Ki;Qu, Zu Qing
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.2 s.48
    • /
    • pp.21-29
    • /
    • 2006
  • It is impractical to install sensors on every floor of a tall building to measure the full state vector because of the large number of degrees of freedom. This makes it necessary to introduce reduced order control. A kind of system reduction scheme (dynamic condensation method) is proposed in this paper. This method is iterative and Guyan condensation is looked upon as an initial approximation of the iteration. Since the reduced order system is updated repeatedly until a desired one is obtained, the accuracy of the reduced order system resulting from the proposed method is much higher than that obtained from the Guyan condensation method. An eigenvalue shilling technique is applied to accelerate the convergence of Iteration. Two schemes to establish the reduced order system by using the proposed method are also presented and discussed in this paper. The results for a tail building with active tuned mass damper show that the proposed method is efficient for the reduced order modelling and the accuracy is very close to exact only after two iterations.

Application of Smart Base Isolation System for Seismic Response Control of an Arch Structure (아치구조물의 지진응답제어를 위한 스마트 면진시스템의 적용)

  • Kang, Joo-Won;Kim, Hyun-Su
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.2
    • /
    • pp.157-165
    • /
    • 2011
  • Base isolation system is widely used for reduction of dynamic responses of structures subjected to seismic load. Recently, research on a smart base isolation system that can effectively reduce dynamic responses of the isolated structure without accompanying increases in base drifts has been actively conducted. In this study, a smart base isolation system was applied to an arch structure subjected to seismic excitation and its control performance for reduction of seismic responses was evaluated. In order to make a smart base isolation system, 4kN MR dampers and low damping elastomeric bearings were used. Seismic response control performance of the proposed smart base isolation system was compared to that of the optimally designed lead-rubber bearing(LRB) isolation system. To this end, an artificial ground motion developed based on KBC2009 design response spectrum was used as a seismic excitation. Fuzzy control algorithm was used to control MR damper in the smart base isolation system and multi-objective genetic algorithm was employed to optimize the fuzzy controller. Based on numerical simulation results, it has been shown that the smart base isolation system can drastically reduce base drifts and seismic responses of the example arch structure in comparison with LRB isolation system.

Evaluation on the Lost Prestressing Force of an External Tendon Using the Combination of FEM and HGA: I. Theory (FEM과 HGA의 조합을 이용한 외부 긴장재의 손실 긴장력 평가: I. 이론)

  • Park, Taehyo;Jang, Hang-Teak;Noh, Myung-Hyun;Park, Kyu-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.5 s.57
    • /
    • pp.109-120
    • /
    • 2009
  • This paper introduces a new method to estimate the loss of prestressing force for the externally prestressing tendon. The proposed method that combines of HGA and FEM is able to identify the lost tensile force of a externally prestressed tendon. The identification variables of the proposed method is a exteranlly prestressed tendon of tension, effective nominal diameter, mass per unit length and Rayleigh damping coefficients. First of all, a finite element model system is constructed to consider the effect of damping, and these variables are identified using inverse analysis technique - updating algorithm. Finally, throughout total 3 cases of numerical tests, the numerical propriety of the proposed method is verified. Here, it is seen that the errors in the estimated variables by the proposed method are about 1% except in the case of Rayleigh damping coefficients.

Multibody Dynamics Simulation and Experimental Study on the Tagline Control of a Cargo Suspended by a Floating Crane (해상크레인으로 인양하는 중량물의 Tagline 제어를 위한 다물체계 동역학 시뮬레이션 및 실험)

  • Ku, Nam-Kug;Lee, Kyu-Yuel;Kwon, Jung-Han;Cha, Ju-Hwan;Ham, Seung-Ho;Ha, Sol;Park, Kwang-Phil
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.1
    • /
    • pp.13-22
    • /
    • 2010
  • This paper describes tagline PD control for reduction of motion for the heavy cargo(load) suspended by a floating crane. The equations of motion are set up considering the 6-degree-of-freedom floating crane and the 6-degree-of-freedom load based on multi-body system dynamics. The tagline mechanism is applied to floating crane to control motion of the heavy cargo(load). The winch, mounted on the deck of floating crane, is used to control the tension of tagline. To generate control force, PD control algorithm is applied. Numerical simulation and experiment is executed to verify the tagline control mechanism. The numerical simulation and experiment shows that the tagline control mechanism reduces the motion of the load suspended by a floating crane.

A Node Grouping Method for Transmission Power Saving in Underwater Acoustic Sensor Network (수중 센서 네트워크에서 노드 그룹화를 통한 전송전력 절약 방안)

  • Hwang, Sung-Ho;Cho, Ho-Shin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.774-780
    • /
    • 2009
  • This paper proposes a transmitted power saving method for underwater acoustic sensors considering the acoustic wave propagation characteristic that propagation loss increases more rapidly in higher frequency band. In the proposed scheme, sensor nodes are divided into a few groups based on the distance between sink node and the sensor node, and each group uses its own frequency band. The node group with longer distance uses lower frequency and the node group with shorter distance uses higher frequency. By means of such a distance-dependent frequency allocation, all sensor nodes are able to maintain a certain target signal-to-noise ratio (SNR), but also save transmitted power. In addition, the optimum size of node group is obtained, and also a frequency allocation algorithm is proposed accordingly. Numerical results show that the proposed scheme saves transmitted power by more 10 dB comparing non-grouping methods.