• Title/Summary/Keyword: 각가속도

Search Result 608, Processing Time 0.037 seconds

Dietary habits and nutrient intake status of university students according to obesity risk based on body mass index and percent body fat (BMI와 체지방률을 고려한 비만위험도 판정에 따른 대학생의 식생활 및 섭취 양상 연구)

  • Chae Hong Lee;Kyung A Lee
    • Journal of Nutrition and Health
    • /
    • v.56 no.6
    • /
    • pp.714-729
    • /
    • 2023
  • Purpose: Since the coronavirus pandemic, the number of obese people has increased, and accelerated aging has been reported, particularly among young population. Therefore, this study analyzed the dietary habits of university students according to their risk of obesity to provide data for improving their eating habits. Methods: Ninety students at Daegu Catholic University were surveyed for their eating habits and photo-enhanced meal intake. The obesity risk was categorized as normal if the body mass index (BMI) and percent body fat (PBF) were normal, at-risk if both indicated overweight or obese, obesity in BMI alone were analyzed as BMI group and those with obesity in percent body fat alone were analyzed as PBF group. Results: There were 23 (25.5%) in the normal group, 10 (11.1%) in the BMI group, 24 (26.7%) in the PBF group and 33 (36.7%) in the at-risk group. The dietary survey showed that the risk groups had lower consumption frequencies of vegetables (p < 0.05) than the normal group, had less sleep time (p < 0.05) and higher frequency of fast food consumption (p < 0.001). The intake of vegetables was significantly higher in the normal group than in the risk group (p < 0.05). In terms of the daily nutrient intake, there was no significant difference in energy intake according to the obesity risk, but the intakes of dietary fiber (p < 0.01), vitamin A (p < 0.01), vitamin C (p < 0.01) were higher in the normal group than in the risk groups. Conclusion: Therefore, it is important to consider the BMI and percent body fat together to diagnose obesity and provide nutrition education and counseling.

Effect of Fractionated X-ray Irradiation on Sprouted Barley Growth and Chlorophyll Concentration (X선의 분할조사가 새싹보리 생장과 클로로필 농도에 미치는 영향)

  • In Suck Park;Won-Jeong Lee;Sang-Bok Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1171-1178
    • /
    • 2023
  • In study, we investigated changes on growth and chlorophyll concentration on sprouted barley by fractionated X-ray irradiation (FXI). Group was divided into the control group (CG), 1-time irradiation group (30 Gy once), 2-time irradiation group (15 Gy 2 times), and 3-time irradiation group (10 Gy 3 times), and 20 grains were used per group. Experimental group (EG) was exposed by using linear accelerator (Clinac IS, VERIAN, USA), by 6 MV X-ray, SSD 100 cm, 18×10 cm2, 600 MU/min. Length was measured every day until 9th day, and chlorophyl was analyzed using spectrophotometer(uv-1800, shimadzu, japan) in 9th day. Data analysis was performed the One-way ANOVA using SPSS ver 26.0(Chicago, IL, USA). In the pre-germination irradiation group (Pre-GIG), the CG had greater length than the EG on all measurement days, and as the number of FXI increased, the length became shorter. In the post-germination irradiation group (Post-GIG), the length of the CG was statistically significantly greater than that of the EG on all measurement days, and as the number of FXI increased, the length also became longer. The chlorophyll concentration was higher in the Post-GIG than in the Pre-GIG, and chlorophyll concentrations of EG was higher in the Pre-GIG than in the CG, as well as and Post-GIG. In addition, the smaller the number of FXI, the higher the chlorophyll concentration in both groups. FXI was found to affect the growth and chlorophyll concentration of sprouted barley.

Investigation of Study Items for the Patterns of Care Study in the Radiotherapy of Laryngeal Cancer: Preliminary Results (후두암의 방사선치료 Patterns of Care Study를 위한 프로그램 항목 개발: 예비 결과)

  • Chung Woong-Ki;Kim I1-Han;Ahn Sung-Ja;Nam Taek-Keun;Oh Yoon-Kyeong;Song Ju-Young;Nah Byung-Sik;Chung Gyung-Ai;Kwon Hyoung-Cheol;Kim Jung-Soo;Kim Soo-Kon;Kang Jeong-Ku
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.299-305
    • /
    • 2003
  • Purpose: In order to develop the national guide-lines for the standardization of radiotherapy we are planning to establish a web-based, on-line data-base system for laryngeal cancer. As a first step this study was performed to accumulate the basic clinical information of laryngeal cancer and to determine the items needed for the data-base system. Materials and Methods: We analyzed the clinical data on patients who were treated under the diagnosis of laryngeal cancer from January 1998 through December 1999 In the South-west area of Korea. Eligiblity criteria of the patients are as follows: 18 years or older, currently diagnosed with primary epithelial carcinoma of larynx, and no history of previous treatments for another cancers and the other laryngeal diseases. The items were developed and filled out by radiation oncologlst who are members of forean Southwest Radiation Oncology Group. SPSS vl0.0 software was used for statistical analysis. Results: Data of forty-five patients were collected. Age distribution of patients ranged from 28 to 88 years(median, 61). Laryngeal cancer occurred predominantly In males (10 : 1 sex ratio). Twenty-eight patients (62$\%$) had primary cancers in the glottis and 17 (38$\%$) in the supraglottis. Most of them were diagnosed pathologically as squamous cell carcinoma (44/45, 98$\%$). Twenty-four of 28 glottic cancer patients (86$\%$) had AJCC (American Joint Committee on Cancer) stage I/II, but 50$\%$ (8/16) had In supraglottic cancer patients (p=0.02). Most patients(89$\%$) had the symptom of hoarseness. indirect laryngoscopy was done in all patients and direct laryngoscopy was peformed in 43 (98$\%$) patients. Twenty-one of 28 (75$\%$) glottic cancer cases and 6 of 17 (35$\%$) supraglottic cancer cases were treated with radiation alone, respectively. The combined treatment of surgery and radiation was used in 5 (18$\%$) glottic and 8 (47$\%$) supraglottic patients. Chemotherapy and radiation was used in 2 (7$\%$) glottic and 3 (18$\%$) supraglottic patients. There was no statistically significant difference in the use of combined modality treatments between glottic and supraglottic cancers (p=0.20). In all patients, 6 MV X-ray was used with conventional fractionation. The iraction size was 2 Gy In 80$\%$ of glottic cancer patients compared with 1.8 Gy in 59$\%$ of the patients with supraglottic cancers. The mean total dose delivered to primary lesions were 65.98 ey and 70.15 Gy in glottic and supraglottic patients treated, respectively, with radiation alone. Based on the collected data, 12 modules with 90 items were developed or the study of the patterns of care In laryngeal cancer. Conclusion: The study Items for laryngeal cancer were developed. In the near future, a web system will be established based on the Items Investigated, and then a nation-wide analysis on laryngeal cancer will be processed for the standardization and optimization of radlotherapy.

Dosimetric Effect on Selectable Optimization Parameters of Volumatric Modulated Arc Therapy (선택적 최적화 변수(Selectable Optimization Parameters)에 따른 부피적조절회전방사선치료(VMAT)의 선량학적 영향)

  • Jung, Jae-Yong;Shin, Yong-Joo;Sohn, Seung-Chang;Kim, Yeon-Rae;Min, Jung-Wan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.15-25
    • /
    • 2012
  • The aim of this study is to evaluate plan quality and dose accuracy for Volumetric Modulated Arc Therapy (VMAT) on the TG-119 and is to investigate the effects on variation of the selectable optimization parameters of VMAT. VMAT treatment planning was implemented on a Varian iX linear accelerator with ARIA record and verify system (Varian Mecical System Palo Alto, CA) and Oncentra MasterPlan treatment planning system (Nucletron BV, Veenendaal, Netherlands). Plan quality and dosimetric accuracy were evaluated by effect of varying a number of arc, gantry spacing and delivery time for the test geometries provided in TG-119. Plan quality for the target and OAR was evaluated by the mean value and the standard deviation of the Dose Volume Histograms (DVHs). The ionization chamber and $Delta^{4PT}$ bi-planar diode array were used for the dose evaluation. For treatment planning evaluation, all structure sets closed to the goals in the case of single arc, except for the C-shape (hard), and all structure sets achieved the goals in the case of dual arc, except for C-shape (hard). For the variation of a number of arc, the simple structure such as a prostate did not have the difference between single arc and dual arc, whereas the complex structure such as a head and neck showed a superior result in the case of dual arc. The dose distribution with gantry spacing of $4^{\circ}$ was shown better plan quality than the gantry spacing of $6^{\circ}$, but was similar results compared with gantry spacing of $2^{\circ}$. For the verification of dose accuracy with single arc and dual arc, the mean value of a relative error between measured and calculated value were within 3% and 4% for point dose and confidence limit values, respectively. For the verification on dose accuracy with the gantry intervals of $2^{\circ}$, $4^{\circ}$ and $6^{\circ}$, the mean values of relative error were within 3% and 5% for point dose and confidence limit values, respectively. In the verification of dose distribution with $Delta^{4PT}$ bi-planar diode array, gamma passing rate was $98.72{\pm}1.52%$ and $98.3{\pm}1.5%$ for single arc and dual arc, respectively. The confidence limit values were within 4%. The smaller the gantry spacing, the more accuracy results were shown. In this study, we performed the VMAT QA based on TG-119 procedure, and demonstrated that all structure sets were satisfied with acceptance criteria. And also, the results for the selective optimization variables informed the importance of selection for the suitable variables according to the clinical cases.

Correlation analysis of radiation therapy position and dose factors for left breast cancer (좌측 유방암의 방사선치료 자세와 선량인자의 상관관계 분석)

  • Jeon, Jaewan;Park, Cheolwoo;Hong, Jongsu;Jin, Seongjin;Kang, Junghun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.37-48
    • /
    • 2017
  • Purpose: The most basic conditions of radiation therapy is to prevent unnecessary exposure of normal tissue. The risk factors that are important o evaluate the dose emitted to the lung and heart from radiation therapy for breast cancer. Therefore, comparing the dose factors of a normal tissue according to the radion treatment position and Seeking an effective radiation treatment for breast cancer through the analysis of the correlation relationship. Materials and Methods: Computed tomography was conducted among 30 patients with left breast cancer in supine and prone position. Eclipse Treatment Planning System (Ver.11) was established by computerized treatment planning. Using the DVH compared the incident dose to normal tissue by position. Based on the result, Using the SPSS (ver.18) analyzed the dose in each normal tissue factors and Through the correlation analysis between variables, independent sample test examined the association. Finally The HI, CI value were compared Using the MIRADA RTx (ver. ad 1.6) in the supine, prone position Results: The results of computerized treatment planning of breast cancer in the supine position were V20, $16.5{\pm}2.6%$ and V30, $13.8{\pm}2.2%$ and Mean dose, $779.1{\pm}135.9cGy$ (absolute value). In the prone position it showed in the order $3.1{\pm}2.2%$, $1.8{\pm}1.7%$, $241.4{\pm}138.3cGy$. The prone position showed overall a lower dose. The average radiation dose 537.7 cGy less was exposured. In the case of heart, it showed that V30, $8.1{\pm}2.6%$ and $5.1{\pm}2.5%$, Mean dose, $594.9{\pm}225.3$ and $408{\pm}183.6cGy$ in the order supine, prone position. Results of statistical analysis, Cronbach's Alpha value of reliability analysis index is 0.563. The results of the correlation analysis between variables, position and dose factors of lung is about 0.89 or more, Which means a high correlation. For the heart, on the other hand it is less correlated to V30 (0.488), mean dose (0.418). Finally The results of independent samples t-test, position and dose factors of lung and heart were significantly higher in both the confidence level of 99 %. Conclusion: Radiation therapy is currently being developed state-of-the-art linear accelerator and a variety of treatment plan technology. The basic premise of the development think normal tissue protection around PTV. Of course, if you treat a breast cancer patient is in the prone position it take a lot of time and reproducibility of set-up problems. Nevertheless, As shown in the experiment results it is possible to reduce the dose to enter the lungs and the heart from the prone position. In conclusion, if a sufficient treatment time in the prone position and place correct confirmation will be more effective when the radiation treatment to patient.

  • PDF

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF

Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer (두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가)

  • Baek, Min Gyu;Kim, Min Woo;Ha, Se Min;Chae, Jong Pyo;Jo, Guang Sub;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: In modern radiotherapy technology, several methods of image guided radiation therapy (IGRT) are used to deliver accurate doses to tumor target locations and normal organs, including CBCT (Cone Beam Computed Tomography) and other devices, ExacTrac System, other than CBCT equipped with linear accelerators. In previous studies comparing the two systems, positional errors were analysed rearwards using Offline-view or evaluated only with a Yaw rotation with the X, Y, and Z axes. In this study, when using CBCT and ExacTrac to perform 6 Degree of the Freedom(DoF) Online IGRT in a treatment center with two equipment, the difference between the set-up calibration values seen in each system, the time taken for patient set-up, and the radiation usefulness of the imaging device is evaluated. Materials and Methods: In order to evaluate the difference between mobile calibrations and exposure radiation dose, the glass dosimetry and Rando Phantom were used for 11 cancer patients with head circumference from March to October 2017 in order to assess the difference between mobile calibrations and the time taken from Set-up to shortly before IGRT. CBCT and ExacTrac System were used for IGRT of all patients. An average of 10 CBCT and ExacTrac images were obtained per patient during the total treatment period, and the difference in 6D Online Automation values between the two systems was calculated within the ROI setting. In this case, the area of interest designation in the image obtained from CBCT was fixed to the same anatomical structure as the image obtained through ExacTrac. The difference in positional values for the six axes (SI, AP, LR; Rotation group: Pitch, Roll, Rtn) between the two systems, the total time taken from patient set-up to just before IGRT, and exposure dose were measured and compared respectively with the RandoPhantom. Results: the set-up error in the phantom and patient was less than 1mm in the translation group and less than 1.5° in the rotation group, and the RMS values of all axes except the Rtn value were less than 1mm and 1°. The time taken to correct the set-up error in each system was an average of 256±47.6sec for IGRT using CBCT and 84±3.5sec for ExacTrac, respectively. Radiation exposure dose by IGRT per treatment was measured at 37 times higher than ExacTrac in CBCT and ExacTrac at 2.468mGy and 0.066mGy at Oral Mucosa among the 7 measurement locations in the head and neck area. Conclusion: Through 6D online automatic positioning between the CBCT and ExacTrac systems, the set-up error was found to be less than 1mm, 1.02°, including the patient's movement (random error), as well as the systematic error of the two systems. This error range is considered to be reasonable when considering that the PTV Margin is 3mm during the head and neck IMRT treatment in the present study. However, considering the changes in target and risk organs due to changes in patient weight during the treatment period, it is considered to be appropriately used in combination with CBCT.

Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning (용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가)

  • Woo, Heon;Park, Jang Pil;Min, Jae Soon;Lee, Jae Hee;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.115-121
    • /
    • 2013
  • Purpose: Latest linear accelerator and the introduction of new measurement equipment to the agency that the introduction of this equipment in the future, by analyzing the process of confirming the usefulness of the preparation process for applying it in the clinical causes some problems, should be helpful. Materials and Methods: All measurements TrueBEAM STX (Varian, USA) was used, and a file specific to each energy, irradiation conditions, the dose distribution was calculated using a computerized treatment planning equipment (Eclipse ver 10.0.39, Varian, USA). Measuring performance and cause errors in MapCHECK 2 were analyzed and measured against. In order to verify the performance of the MapCHECK 2, 6X, 6X-FFF, 10X, 10X-FFF, 15X field size $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ direction was measured by the energy. IGRT couch of the CT values affect the measurements in order to confirm, CT number values : -800 (Carbon) & -950 (COUCH in the air), -100 & 6X-950 in the state for FFF, 15X of the energy field sizes $10{\times}10$, gantry $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ directionwas measured at, MapPHAN allocated to confirm the value of HU were compared, using the treatment planning computer for, Measurement error problem by the sharp edges MapPHAN Learn gantry direction MapPHAN of dependence was measured in three ways. GANTRY $90^{\circ}$, $270^{\circ}$ in the direction of the vertically erected settings 6X-FFF, 15X respectively, and Setting the state established as a horizontal field sizes $10{\times}10$, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$ of in the direction of the energy-6X-FFF, 15X, respectively, were measured. Without intensity modulated beam of the third open arc were investigated. Results: Of basic performance MapCHECK confirm the attenuation measured by Couch, measured from the measured HU values that are assigned to the MAP-PHAN, check for calculation accuracy for the angled edge of the MapPHAN all come in a range of valid measurement errors do not affect the could see. three ways for the Gantry direction dependence, the first of the meter built into the value of the Gantry $270^{\circ}$ (relative $0^{\circ}$), $90^{\circ}$ (relative $180^{\circ}$), 6X-FFF, 15X from each -1.51, 0.83% and -0.63, -0.22% was not affected by the AP/PA direction represented. Setting the meter horizontally Gantry $90^{\circ}$, $270^{\circ}$ from the couch, Energy 6X-FFF 4.37, 2.84%, 15X, -9.63, -13.32% the difference. By-side direction measurements MapPHAN in value is not within the valid range can not, because that could be confirmed as gamma pass rate 3% of the value is greater than the value shown. You can check the Open Arc 6X-FFF, 15X energy, field size $10{\times}10$ cm $360^{\circ}$ rotation of the dose distribution in the state to look at nearly 90% pass rate to emerge. Conclusion: Based on the above results, the MapPHAN gantry direction dependence by side in the direction of the beam relative dose distribution suitable for measuring the gamma value, but accurate measurement of the absolute dose can not be considered is. this paper, a more accurate treatment plan in order to confirm, Reduce the tolerance for VMAT, such as lateral rotation investigation in order to measure accurate absolute isodose using a combination of IMF (Isocentric Mounting Fixture) MapCHEK 2, will be able to minimize the impact due to the angular dependence.

  • PDF