• 제목/요약/키워드: 가열시험

검색결과 566건 처리시간 0.028초

Tensile Characteristics of A12024-T3 under Rapid Heating (급속가열환경에서 A12024-T3의 인장특성)

  • Kim, Jong-Hwan;Kim, Jae-Hoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • 제32권8호
    • /
    • pp.101-108
    • /
    • 2004
  • The thermomechanical tensile characteristics were evaluated for A12024-T3 under heating rates from $1^{\circ}C/sec\;to\;30^{\circ}C/sec$ by using an infrared heating equipment to simulate aerodynamic heating. The rapid heating test results were compared with tensile test results after 1/2 hour exposure in terms of yield stress to investigate the influence of heating condition. A heating rate-yield temperature parameter was suggested for rapid heating based on time-temperature parameters, and master yield stress curve was obtained by using these parameter. These test results can be used for margin of safety of supersonic vehicle structures subjected to aerodynamic heating.

원자로 RI 생산용 조사용기 제작 및 시험

  • 박울재;한현수;조운갑;홍순복;이철영
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(2)
    • /
    • pp.763-768
    • /
    • 1998
  • 방사성동위원소 생산용 표적을 중성자 조사하기 위해 하나로의 제반 특성을 고려하여 조사용기를 개발하였다 IP(Isotope Production), HTS(Hydraulic Transfer System) 조사공별로 내.외부용기를 제작하였으며 재료는 검증된 Al-1050을 사용하였다. 내부용기는 냉간용접(Cold Welding) 하고, 외부용기는 TIG(Tungsten Inert Gas) 또는 전자빔으로 용접한 후 He을 충진하고 밀봉하였다. 조사용기의 건전성을 입증하기 위해 기포누설시험, 내압시험, 가열시험, 침투탐상시험, He 누설시험을 수행하였다. 기포누설시험 결과 내부용기는 90% 이상이 3x$10^{-6}$atm.cc/sec 이하의 누설율을 보였고, 내압시험 결과 파단압력은 28kg/$\textrm{cm}^2$ 정도였다. 외부용기는 TIG 용접시 70%, 전자빔 용접시 90% 이상이 누설율 1x$10^{-8}$atm.cc/sec 이하였다. 개발된 조사용기를 사용하여 하나로에서 200여회 방사성동위원소를 생산하였으나 중성자 조사중 누출을 포함한 기타의 문제가 발생하지 않았다. 조사용기 개발에서 확립된 밀봉시험, 내압시험 및 가열시험 방법은 기체표적이나 내압이 발생하는 표적용기의 개발 및 시험에 응용할 수 있다.

  • PDF

Performance test of Vitiated Air Heater with High Temperature and High Pressure I (고온 고압 공기가열기 성능시험 I)

  • Lee, Jungmin;Na, Jaejeong;Hong, Yunky;Kang, Kyungtaik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.301-303
    • /
    • 2017
  • This study is the performance test of the vitiated air heater with high temperature and high pressure. The vitiated air heater to provide hot air about 2000 K was designed, and the performance test is carrying out. The designed vitiated air heater uses methane, oxygen, and mixing air by working gases, and uses mixing air for cooling of the bottom of a mixing head. By this reason, the vitiated ar heater has to be designed with heat-resistance from hot frame, and to be tested for its proof. In this paper the performance of he vitiated air heater is analyzed to some test results.

  • PDF

Development and Performance of Semi-Hot Foamed Recycling Asphalt Mixture (반 가열 재생 폼드 아스팔트 혼합물의 개발 및 성능시험 연구)

  • Park, Tae-Soon;Kim, Yong-Joo;Kim, Ki-Hyun
    • International Journal of Highway Engineering
    • /
    • 제4권1호
    • /
    • pp.135-147
    • /
    • 2002
  • Application of the foamed asphalt techniques in recycling the waste asphalt shows that large quantify of waste asphalt(60$\sim$70% of the total mix) can be used comparing with hot mix asphalt techniques and also is environmentally safe. However, the constant quality of the recycling foamed asphalt mixtures is not readily achieved and can not be applied to the heavy traffic road due to the characteristics of the conventional foamed asphalt mixtures. The semi-hot technique that the RAP and the aggregate is heated below $100^{\circ}C$ is adopted in this study and expected to solve the problems of conventional foamed asphalt mixtures. This study presents the viability of the semi-hot foamed asphalt mixtures when using the RAP. The semi-hot recycling foamed mixtures are tested and evaluated in the laboratory. The test results including coating rates, creep tests, resilient modulus tests, indirect tensile tests and the Marshall stability tests showed significant improvement.

  • PDF

조사핵연료 FP 방출 핵종분석 가열시험장치 개발

  • Kim, Dae-Ho;Kim, Dong-Ju;Kim, Jong-Heon;Bang, Je-Geon;Jeon, Tae-Hyeon;Kim, Seon-Gi;Yang, Jae-Ho
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 한국방사성폐기물학회 2016년도 춘계학술논문요약집
    • /
    • pp.77-78
    • /
    • 2016
  • 사용후핵연료 및 조사핵연료의 안전성평가를 위한 산화시험과 소둔시험을 다양한 핵연료 개발과제에서 준비하고 있다. 한국원자력연구원의 PIEF에서 수행될 본 시험장치는 핫셀의 제한된 특성을 반영하여 효과적인 핵분열생성물의 핵종분석시험이 가능하도록 설계.제작되었다. 가열로의 소형화와 조작의 편이성을 반영하였으며, 핫셀 내 가열로 상부캡위에 Gamma Counter를 설치하여 핵분열생성물의 방출량 측정이 가능하도록 하였다. 시험운용에 있어 일정한 온도범위에서의 가열조건과 급격한 온도변화를 모사할 수 있는 기능이 포함되었다. 아울러, 핵분열생성물의 핵종분석은 계측 외에 세라믹 흡착제에 고착된 방사선량의 측정을 통해 교차평가가 가능하다.

  • PDF

Design and Manufacture of Storage Air Heater (축열식 가열기의 설계 및 제작)

  • Lee, Yang-Ji;Kang, Sang-Hun;Park, Poo-Min;Yang, Soo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.43-46
    • /
    • 2006
  • Storage air heater(SAH) is a general purpose facility that is used to simulate the high altitude condition of supersonic ground test facility, thurst compensation test of rocket engine nozzle and gas turbine engine combustor test. SAH in KARI is built to simulate the total temperature of the supersonic ground test facility which has a wide flight envelope from altitude 0km, Mach 2 to altitude 25km, Mach 5 and operates up to 1300K, 3.5MPa. In this paper, we introduces the SAH in JAXA which is model of SAH in KARI and summarizes the design process and manufacture of ours.

  • PDF

Study of morphology on the Oxidation and the Annealing of High Burn-hp $UO_2$ Spent Fuel (고연소도 사용후 핵연료의 가열산화와 고온가열을 통한 미세조직 변화고찰)

  • Kim Dae Ho;Bang Jae Geun;Yang Yong Sik;Song Keun Woo;Lee Hyung Kwon;Kwon Hyung Moon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • 제3권4호
    • /
    • pp.301-307
    • /
    • 2005
  • The morphology of the high burnup $UO_2$ spent fuel, which was oxidized and annealed in a PIA (Post Irradiation Annealing) apparatus, has been observed. The high burnup fuel irradiated in Ulchin Unit 2, average rod burnup 57,000 MWd/tU, was transported to the KAERI's PIEF. The test specimen was used with about 200 mg of the spent $UO_2$ fuel fragment of the local burnup 65,000 MWd/tU. This specimen was annealed at $1400^{\circ}C$ for 4hrs after the oxidation for 3hrs to grain boundary using the PIA apparatus in a hot-cell. In order to oxidize the grain boundary, the oxidation temperature increased up to $500^{\circ}C$ and held for 3hrs in the mixed gas (60 ml He and 100 ml STD-air) atmosphere. The amount of 85Kr during the whole test process was measured to know the fission gas release behavior using the online system of a beta counter and a gamma counter. The detailed micro-structure was observed by a SEM to confirm the change of the fuel morphology after this test. As the annealing temperature increased, the fission products were observed to move to the grain surface and grain boundary of the $UO_2$ matrix. This specimen was re-structured through the reduction process, and the grain sizes were distributed from 5 to $10\;{\mu}m$.

  • PDF

Experimental Study on the Water Content Formula of Fresh Concrete by Microwave Oven Drying Test Method (고주파 가열건조 시험방법에 의한 굳지 않은 콘크리트의 단위수량 추정식에 관한 실험적 연구)

  • Park, Min-Yong;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • 제23권2호
    • /
    • pp.143-152
    • /
    • 2023
  • In this research, the microwave oven drying method was investigated as a potential accurate testing approach for determining the water content of fresh concrete. To do so, water content estimation formulas employed in three prominent oven drying test methods were selected, and the calculation principles for each equation, along with potential error factors arising during the actual testing process, were considered. Moreover, a concrete test was conducted to validate the possible error factors. Consequently, it was confirmed that estimation errors in the water content of fresh concrete can occur due to sample deviations arising during the wet screening process for creating mortar specimens or deviations in the coarse aggregate sampling quantity during the sample collection process.

Heating Apparatus Development and Tests for Cryogenic Gaseous Helium (극저온 헬륨가스 가열장치 개발 및 시험)

  • Chung, Yong-Gahp;Cho, Nam-Kyung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • 제15권1호
    • /
    • pp.63-68
    • /
    • 2011
  • For the liquid rocket propulsion system using liquid oxygen as oxidizer, helium for pressurizing LOX is usually stored in the LOX tank with cryogenic temperature. For that kind of pressurizing system, cryogenic helium is discharged from the immerged pressurant cylinder and passes through the heat exchanger downstream of gas generator. During the process, helium pressurant is heated from cryogenic temperature to high one and supplied to the ullage of propellant tank. To develop the pressurizing system, a cryogenic heating apparatus is needed to simulate the heat exchanger. In this paper, the cryogenic heating apparatus for development of the pressurization system is presented along with its heating test results with cryogenic helium.

Heating Apparatus Development for Cryogenic Gaseous Helium (극저온 헬륨가스 가열장치 개발)

  • Chung, Yong-Gahp;Kwon, Oh-Sung;Cho, Nam-Kyung;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.363-367
    • /
    • 2009
  • For the liquid rocket propulsion system using liquid oxygen as oxidizer, helium for pressurizing LOX is usually stored in the LOX tank with cryogenic temperature. For that kind of pressurizing system, cryogenic helium is discharged from the immerged pressurant cylinder and passes through the heat exchanger downstream of gas generator. During the process, helium pressurant is heated from cryogenic temperature to high one and supplied to the ullage of propellant tank. To develop the pressurizing system, a cryogenic heating apparatus is needed to simulate the heat exchanger. In this paper, the cryogenic heating apparatus for development of the pressurization system is presented along with its heating test results with cryogenic helium.

  • PDF