• Title/Summary/Keyword: 'room'

Search Result 15,343, Processing Time 0.042 seconds

A Study on the Planning of Children's Room (아동실의 실내계획방향에 관한 연구)

  • 황연숙;오찬옥
    • Korean Institute of Interior Design Journal
    • /
    • no.11
    • /
    • pp.64-69
    • /
    • 1997
  • The purpose of this study was to examine the current interior conditions of children's rooms and to suggest theplanning guidelines of children's rooms. Data were collected through questionnaire survey including measurements and observations. The sample consisted of 291 households with the 3-5 years old children in Pusav. Data were analyzed by using SPSS-PC. The major findings were as follows : 1) It was found that most of children lived in small rooms. Considering their furnitures and equipments, the size of children's rooms should be 10-13 $m^2$. 2) Children's rooms should be closed to their parent's room and living room to take care of children and far from kitchen, balcony, diming room to prevent hazards. 3) Interior finishings such as wall papers, floor coverings should be chosen to consider the children's tastes and their preferred styles. 4) The types of furniture arrangement were divided by 5 types: one wall type, parallel type, ㄱ type, ㄷ type, ㅁ type. 5) The local lighting such as task lighting for studying and playing night lamp for sleeping should be used.

  • PDF

A Study on the Planning of the Infirmary in Primary School for Integrated Education (통합교육을 위한 초등학교 보건실 기본 계획에 관한 연구)

  • Yoon, Soo-Jin;Chai, Choul-Gyun
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.5 s.58
    • /
    • pp.175-182
    • /
    • 2006
  • School's preservation of health aims at the promotion of efficiency for school education as it promotes students and all teaching staffs' health. In this study, 26 elementary schools in seoul were selected and analyzed, in order to make a basic plan of efficient public health room where students and all teaching staffs can be actively treated their physical and mental problems. The basic direction of school health was referred to promote school's preservation of health. A public health room should have each necessary field to do their own parts. Besides, its space plan has to be designed in detail so that the room can be convenient and comfortable. Unlike until now, we need to change our mind into planing a public health room apart from a school plan.

A Study on the Effect of Physical Environment of Childroom on Children's Personality (아동실의 물리적인 환경이 아동인성에 미치는 영향에 관한 연구)

  • 황연숙;이연숙
    • Journal of the Korean housing association
    • /
    • v.14 no.2
    • /
    • pp.51-61
    • /
    • 2003
  • The purpose of this research is to find out environmental characteristics of elementary school children's room, and determine the relationship between children's room environment and their personality. The finding showed that environmental characteristics of children's room has relationship with children's personality. Such environmental characteristics as convenience, order, originality, safety, and territoriality had a direct and high relationship with children's personality, while such environmental characteristics as accessibility, ability to express, comfortability, privacy, and social interaction had indirect relationship with children's personality through three intervening variables. The finding further said that achievement motivation and reflectiveness of children's personality were the most influenced by children's room environmental characteristics. The environmental characteristics that are the most influential to children's personality were found to be order.

A Study on the Yearly Thermal Environmental Characteristics in Underground Space (지하거주공간의 연간 열환경에 관한 연구)

  • Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.2 no.3
    • /
    • pp.27-33
    • /
    • 1998
  • The room temperature and air conditioning load in the underground space have been investigated numerically by the unsteady heat conduction equation. The model room has 3 m in height and 10 m in width, and it's position in the underground depth are 0.5 m to 5 m. When the room was located around surface, the room temperatures were strongly influenced by the atmosphere. But the underground depth is more than 2 m, the yearly temperature amplitude was small and the temperature phase was delayed. Up to 5 m of the depth, the cooling and heating load was decreased rapidly, but over 10 m of the depth, the air conditioning load was constant.

  • PDF

A Study on the Present Color Plan of Environment in the space the Hospitals (병원공간의 색채환경 실태에 관한 연구 -설계에 따른 마감재에 한해서-)

  • 최승희;윤갑근
    • Korean Institute of Interior Design Journal
    • /
    • no.19
    • /
    • pp.144-150
    • /
    • 1999
  • The color planning in the hospital could influence the patient's improvement and lead the users from room to room. This study shows the data of present colors used in the hospitals. In order to get the data, we surveyed and analyzed the current color usages of the present interior of hospitals by the individual data from the projectors. The color scheme is analyzed by the rooms which are the common room, the ward, and the examination room along the projectors. It is also analyzed by the finishes of the hospitals, and is addressed to the present color scheme by the means of the hue value, and chroma. The color scheme in the interior design of hospital is an important factor for the hospital users. It has to more sincerely considered to use colors effectively in the hospital interior since people use their organ of vision greatly when they sense things. According to the data, this study is proposed to the effective color plan which is considered psychologically and emotionally about the human activities, in the interior design of hospitals for the future.

  • PDF

The Numerical Study of the Effect of Car Front Opening Area on the mean Flow in Engine Room (차 개구형상이 엔진룸내 유동에 미치는 영향에 관한 수치연구)

  • 류명석;이은준;구영곤
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.2
    • /
    • pp.158-165
    • /
    • 1996
  • The knowledge of air flow in an engine room has become more and more important in recent car design. The fluid flow in the engine compartment was investigated by numerical analysis. Due to the complex geometry of the engine compartment, mesh generation is a time-consuming job. In this research, the "ICEM" code was used to generate meshes by the Cartesian mesh model. The Reynolds-averaged Navier Stokes equations, together with the porous flow model for radiator and condenser, were solved. Computation was performed for the steady, incompressible, and high speed viscous flow, adopting the standard K-ε turbulence model. The "STAR-CD" code was used as a solver. The effect of car front openning area on the flow in engine room was also investigated.

  • PDF

Development of drying apparatus using 2-way condensation for marine products (2방식 응축을 이용한 수산물 건조 장치 개발)

  • Hwang, Jea-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.42 no.4
    • /
    • pp.259-266
    • /
    • 2006
  • In this study, the 2-way condensation system was designed applying air-to-air heat pump to dry a marine product such as squid in the winter. And to be made the drying apparatuses by this system, there are two kinds of type, A type, was set a compressor outside of the drying apparatus, B type, was set a compressor in the drying room. And then the variations of temperature in drying room were measured to compare the heating performance of the drying apparatuses between A type and B type at $-6.5^{\circ}C$, outdoor temperature. The temperature of the drying room for B type was increased to $36^{\circ}C$ but the temperature of the drying room for A type was not increased to $36^{\circ}C$, to be increased to $20^{\circ}C$.

Measures to Reduce Medical Supplies in Stock through Improved Manageme (진료재료의 관리개선을 통한 운영재고 절감 방안)

  • Kim, Kyoung Mi;Park, Jee Hye
    • Quality Improvement in Health Care
    • /
    • v.19 no.1
    • /
    • pp.74-81
    • /
    • 2013
  • Research Problem: 45-65% of all medical supplies in hospital are used in operating rooms. Medical supplies in operating rooms are difficult to manage in general because many of them are frequently used and come in a variety of types. Purpose: Our aim was to strive for user-friendliness and reduce the inventory through efficient management of medical supplies stocked in operating rooms. Medical Facility: Korea University, Ansan Hospital Quality Improvement Activity: On the last day of each month, we checked the inventory of medical supplies in all operating rooms by identifying the amount of medical supplies in each room, warehouse, and OCS, identified problems, and presented the ways to improve. Improvement Outcome: We increased the number of post-processing medical supply items by 8%, and reduced the inventory cost by 15% through improved management of medical supplies.

  • PDF

The Effect of Flow Rate into Room by Natural Convection in Air Conditioner Duct (공조기 덕트 내의 자연대류가 실내 유입유량에 미치는 영향)

  • 공태우;정한식;정효민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.160-166
    • /
    • 2001
  • A numerical analysis has been performed for natural convection in an air conditioner duct system. The governing equations were solved a finite volume method using a SIMPLE algorithm. In the calculation mode of duct, the room temperature was preserved at $25.0^{\circ}C$ and duct wall temperature had a temperature of 15, 20.0, 22.5, 23.75, 26.25, 27.5 30 and $35^{\circ}C$. The results of velocity vectors and contours have been represented for various parameters. Based on the numerical data, the relationships between temperature difference and flow rate into room was represented. In the case of $T_\gamma>T_\omega$, the equation for temperature difference and flow rate was $Q=0.0285\triangleT^0.4005$, and in the case of $T_\gamma>T_\omega$, the equation was $Q=0.0099\triangleT^0.4752$. The duct system has an important relation to room temperature and duct wall temperature.

  • PDF

Numerical Analysis of Ventilation Effectiveness using Turbulent Airflow Modeling (난류유동해석을 통한 환기효율의 수치해석적 연구)

  • Han, H.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.4
    • /
    • pp.253-262
    • /
    • 1992
  • A numerical procedure is introduced to calculate local ventilation effectiveness using the definitions of local decay rate and local mean age. A low Reynolds number $k-{\varepsilon}$ model is implemented to calculate steady state turbulent velocity distributions, and a step-down method is used to calculate transient concentration distributions. Simulations are carried out for several different values of air change rates and several different diffuser angles in a two-dimensional model of a half scale office room. The results show that the local ventilation effectiveness within a room could vary significantly from one location to another. The nominal air change rate based on the assumption of complete mixing of room air does not provide the local ventilation effectiveness information. It is numerically proved that the local mean age distribution obtained from the transient calculation is equivalent to the steady state concentration distribution with homogeneously distributed contaminant sources.

  • PDF