Browse > Article
http://dx.doi.org/10.3796/KSFT.2006.42.4.259

Development of drying apparatus using 2-way condensation for marine products  

Hwang, Jea-Ho (Dept. of power system engineering, Gangwon Provincial College)
Publication Information
Journal of the Korean Society of Fisheries and Ocean Technology / v.42, no.4, 2006 , pp. 259-266 More about this Journal
Abstract
In this study, the 2-way condensation system was designed applying air-to-air heat pump to dry a marine product such as squid in the winter. And to be made the drying apparatuses by this system, there are two kinds of type, A type, was set a compressor outside of the drying apparatus, B type, was set a compressor in the drying room. And then the variations of temperature in drying room were measured to compare the heating performance of the drying apparatuses between A type and B type at $-6.5^{\circ}C$, outdoor temperature. The temperature of the drying room for B type was increased to $36^{\circ}C$ but the temperature of the drying room for A type was not increased to $36^{\circ}C$, to be increased to $20^{\circ}C$.
Keywords
Heat pump; Coefficient of performance(COP); Drying apparatus; 2-way condensation; Dehumidification weight;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Christian, J.E., 1977. Unitary air - to - air heat pumps. ICES technol. evaluations, Report ANL/CES/TE, Argonne national laboratory, pp. 126 - 134
2 Harry, J.S. and JR. Ronald, H.H., 1989. Heat pump systems. Wiley interscience, New york, pp. 131-135
3 Healy, J.H., 1962. The heat pump in a cold climate. 49th annual convention of the national warm air heating and air conditioning association, Jacksonville, Florida, pp. 41 - 44
4 Hong, H.G. and Y.T. Gang, 1992. Heat pump and air conditioning system. Sung an dang, Seoul, pp. 13-20
5 Kim, J.R. and K.C. Jeong, 2000. A study on the utilization of exhausted heat from subway for energy source of heat pump. Journal of the Korean Institute of Gas, 4(4), 13 - 21
6 Lim, H.J., Y.S. Song, H.J. Kong and S.K. Park, 2004. Performance evaluation and economic estimation of ground source heat pump cooling and heating system. Energy Engg. Journal, 13(4),296 - 300   과학기술학회마을
7 Park, Y.B., 1999. Development fisheries dryer using the refrigerator of idle energy. Report of small business innovation research of GWPU, pp. 127 - 141