• Title/Summary/Keyword: $f_{max}$

Search Result 557, Processing Time 0.036 seconds

A Development of Embankment Stability Evaluation Method on Soft Foundation (연약지반상의 흙쌓기 안정관리 기법 개발)

  • Kim, Jeong-Seon;Chang, Yong-Chai;Park, Sung-Su
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.9
    • /
    • pp.43-54
    • /
    • 2013
  • This study proposed a new embankment stability control method to analyze the measurement data on the slope activities of the soft ground, using the Stability Control Index (SCI) obtained from the p-q stress paths. In order to validate this new technique, the data from triaxial compression tests (CU) and field measurement were compared. SCI is calculated from the current path of the effective stress points ($p^{\prime}=p-{\Delta}u$) using the relative position between the Total Stress Path $p_{max}$ and the point of $k_f$ line $p_f$. From this result, the point of effective stress $p^{\prime}(=p-{\Delta}u)$ will have access to the point $p_f$ of $k_f$ line when the pore water pressure occurs or the point of total stress pass $p^{\prime}_{max}$ when the pore pressure dissipates. Thus, the Stability Control Index (SCI) can evaluate quantitatively the safety of embankment from the relative position of the effective stress path.

Modification of CPW Pad Design for High fmax InGaAs/InAlAs Metamorphic High Electron Mobility Transistors (높은 $f_{max}$ 를 갖는 InGaAs/InAlAs MHEMT 의 Pad 설계)

  • Choi, Seok-Gyu;Lee, Bok-Hyung;Lee, Mun-Kyo;Kim, Sam-Dong;Rhee, Jin-Koo
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.599-602
    • /
    • 2005
  • In this paper, we have performed a study that modifies the CPW Pad configurations to improve an $f_{max}$ characteristic of metamorphic HEMT. To analyze the CPW Pad structures of MHEMT, we use the ADS momentum simulator developed by $Agilent^{TM}$. Comparing the employed structure (G/W = 40/100 m), the optimized structure (G/W = 20/25 m) of CPW MHEMT shows the increased $S_{21}$ by 2.5 dB, which is one of the dominant parameters influencing the $f_{max}$ of MHEMT. To compare the performances of optimized MHEMT with the employed MHEMT, DC and RF characteristics of the fabricated MHEMT were measured. In the case of optimized CPW MHEMT, the measured saturated drain current density and transconductance $(g_m)$ were 693 mA/mm and 647 mS/mm, respectively. RF measurements were performed in a frequency range of $0.1{\sim}110$ GHz. A high $S_{21}$ gain of 5.5 dB is shown at a millimeter-wave frequency of 110 GHz. Two kinds of RF gains, $h_{21}$ and maximum available gain (MAG), versus the frequency, and a cut-off frequency ($f_t$) of ${\sim}154$ GHz and a maximum frequency of oscillation ($f_{max}$) of ${\sim}358$ GHz are obtained, respectively, from the extrapolation of the RF gains for a device biased at a peak transconductance. An optimized CPW MHEMT structure is one of the first reports among fabricated 0.1 m gate length MHEMTs.

  • PDF

ERROR BOUNDS FOR GAUSS-RADAU AND GAUSS-LOBATTO RULES OF ANALYTIC FUNCTIONS

  • Ko, Kwan-Pyo
    • Communications of the Korean Mathematical Society
    • /
    • v.12 no.3
    • /
    • pp.797-812
    • /
    • 1997
  • For analytic functions we give an expression for the kernel $K_n$ of the remainder terms for the Gauss-Radau and the Gauss-Lobatto rules with end points of multiplicity r and prove the convergence of the kernel we obtained. The error bound are obtained for the type $$\mid$R_n(f)$\mid$ \leq \frac{1}{\pi}l(\Gamma) max_{z \in \Gamma} $\mid$K_n(z)$\mid$ max_{z \in \Gamma} $\mid$f(z)$\mid$$, where $l(\Gamma)$ denotes the length of contour $\Gamma$.

  • PDF

Different $^{18}$F-FDG Uptake According to Tumor location and Morphology of Cholangiocarcinoma and Its Clinical Implication (담관암의 위치와 형태에 따른 $^{18}$F-FDG 섭취량의 차이와 임상적 의의)

  • Lee, Won-Seok;Lee, Yoon-Jae;Lim, Seok-Tae;Sohn, Myung-Hee;Lee, Seung-Ok
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.317-322
    • /
    • 2009
  • Purpose: $^{18}$F-flurodeoxyglucose (FDG) uptake on positron emission tomography (PET) scan has been found to reflect tumor aggressiveness and prognosis in various types of cancer. However, pattern of FDG uptake in biliary malignancies and its clinical significance have not been studied well. The purpose of this study was to assess the additional value of $^{18}$F-FDG PET in differential diagnosis and prognosis of cholangiocarcinoma (CC) according to the tumor location and tumor morphology. Materials and Methods: From April 2005 to May 2008, eighty two patients (M:F = 55:27, age 66.2$\pm$9.6 yrs) with CC underwent $^{18}$F-FDG PET. For semiquantitative analysis, the maximum standardized uptake value (SUV$_{max}$) was obtained from the primary tumor. The difference of SUV$_{max}$ according to the tumor location and tumor growth pattern, such as scirrhous type, nodular type, polypoid type were compared. Results: Overall sensitivity of PET scan was 81.7% in CC. SUV$_{max}$ on PET scan in intrahepatic CC was significantly higher compared to extrahepatic CC. In extrahepatic CC, polypoid type showed significantly higher SUV$_{max}$ compared to scirrhous type. Conclusion: $^{18}$F-FDG PET may have a significant impact on clinical decision-making and on the management of intrahepatic cholangiocarcinoma. And it is related to the shape of the tumor and the sensitivity of detection is higher in the mass-forming type than in the scirrhous type.

A 45GHz $f_{T}\;and\;50GHz\;f_{max}$ SiGe BiCMOS Technology Development for Wireless Communication ICs (무선통신소자제작을 위한 45GHz $f_{T}$ 및 50GHZz $f_{max}$ SiGe BiCMOS 개발)

  • Hwang Seok-Hee;Cho Dae-Hyung;Park Kang-Wook;Yi Sang-Don;Kim Nam-Ju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.9 s.339
    • /
    • pp.1-8
    • /
    • 2005
  • A $0.35\mu$m SiGe BiCMOS fabrication process has been timely developed, which is aiming at wireless RF ICs development and fast growing SiGe RF market. With non-selective SiGe epilayer, SiGe HBTs in this process used trapezoidal Ge base profile for the enhanced AC performance via Ge induced bandgap niuoin. The characteristics of hFE 100, $f_{T}\;45GHz,\;F_{max}\;50GHz,\;NF_{min}\;0.8dB$ have been obtained by optimizing not only SiGe base profile but also RTA condition after emitter polysilicon deposition, which enables the SiGe technology competition against the worldwide cutting edge SiGe BiCMOS technology. In addition, the process incorporates the CMOS logic, which is fully compatible with $0.35\mu$m pure logic technology. High Q passive elements are also provided for high precision analog circuit designs, and their quality factors of W(1pF) and inductor(2nH) are 80, 12.5, respectively.

Acoustic Analysis of Voice Change According to Extent of Thyroidectomy (갑상선 수술범위에 따른 음성의 음향적 분석)

  • Kang, Young Ae;Koo, Bon Seok
    • Phonetics and Speech Sciences
    • /
    • v.7 no.4
    • /
    • pp.77-83
    • /
    • 2015
  • Voice complication without the laryngeal nerve injury can occur after thyroidectomy. The purpose of this study is to investigate voice changes according to extent of thyroidectomy with acoustic analysis. Thirty-five female patients with papillary thyroid carcinoma took voice evaluation at before and 1 month, and 3 months after thyroidectomy. Acoustic analysis parameters were speaking fundamental frequency(SFF), min $F_0$, max $F_0$, dynamic range $F_0$, jitter, shimmer, noise-to-harmonic ratio(NHR), and Cepstral prominence peak(CPP). Repeated-measured analysis of variance was applied. Time-related voice changes showed significant differences in all parameters except NHR. At 1 month after surgery, voice quality was worse and pitch was decreasing, but voice quality and pitch were improving at 3-month follow-up. Voice changes according to the extent of surgery were in SFF, max $F_0$, and dynamic range $F_0$. Time by surgery-related voice change existed only in min $F_0$. The result showed that the severity of voice complication depended on the extend of thyroidectomy which had a negative impact on $F_0$-related parameters. The deterioration of voice quality at 1 month after thyroidectomy may be affected by the loss of thyroid hormone in the blood. The descent of $F_0$-related parameters may be impacted by laryngeal fixation of surgical site adhesion.

The Evaluation of Difference according to Image Scan Duration in PET Scan using Short Half-Lived Radionuclide (단 반감기 핵종을 이용한 PET 검사 시 영상 획득 시간에 따른 정량성 평가)

  • Hong, Gun-Chul;Cha, Eun-Sun;Kwak, In-Suk;Lee, Hyuk;Park, Hoon;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.102-107
    • /
    • 2012
  • Purpose : Because of the rapid physical decay of the short half-lived radionuclide, counting of event for image is very limited. In this reason, long scan duration is applied for more accurate quantitative analysis in the relatively low sensitive examination. The aim of this study was to evaluate the difference according to scan duration and investigate the resonable scan duration using the radionuclide of 11C and 18F in PET scan. Materials and Methods : 1994-NEMA Phantom was filled with 11C of $30.08{\pm}4.22MBq$ and 18F of $40.08{\pm}8.29MBq$ diluted with distilled water. Dynamic images were acquired 20frames/1minute and static image was acquired for 20minutes with 11C. And dynamic images were acquired 20frames/2.5minutes and static image was acquired for 50minutes with 18F. All of data were applied with same reconstruction method and time decay correction. Region of interest (ROI) was set on the image, maximum radioactivity concentration (maxRC, kBq/mL) was compared. We compared maxRC with acquired dynamic image which was summed one bye one to increase the total scan duration. Results : maxRC over time of 11C was $3.85{\pm}0.45{\sim}5.15{\pm}0.50kBq/mL$ in dynamic image, and static image was $2.15{\pm}0.26kBq/mL$. In case of 18F, the maxRC was $9.09{\pm}0.42{\sim}9.48{\pm}0.31kBq/mL$ in dynamic image and $7.24{\pm}0.14kBq/mL$ in static. In summed image of 11C, as total scan duration was increased to 5, 10, 15, 20minutes, the maxRC were $2.47{\pm}0.4$, $2.22{\pm}0.37$, $2.08{\pm}0.42$, $1.95{\pm}0.55kBq/mL$ respectively. In case of 18F, the total scan duration was increased to 12.5, 25, 37.5, and 50minutes, the maxRC were $7.89{\pm}0.27$, $7.61{\pm}0.23$, $7.36{\pm}0.21$, $7.31{\pm}0.23kBq/mL$. Conclusion : As elapsed time was increased after completion of injection, the maxRC was increased by 33% and 4% in dynamic study of 11C and 18F respectively. Also the total scan duration was increased, the maxRC was reduced by 50% and 20% in summed image of 11C and 18F respectively. The percentage difference of each result is more larger in study using relatively shorter half-lived radionuclide. It appears that the accuracy of decay correction declined not only increment of scan duration but also increment of elapsed time from a starting point of acquisition. In study using 18F, there was no big difference so it's not necessary to consider error of quantitative evaluation according to elapsed time. It's recommended to apply additional decay correction method considering decay correction the error concerning elapsed time or to set the scan duration of static image less than 5minutes corresponding 25% of half life in study using shorter half-lived radionuclide as 11C.

  • PDF

Analysis of characteristics of PHEMT's with gate recess etching method (게이트 리세스 식각 방법에 따른 PHEMT 특성 변화)

  • 이한신;임병옥;김성찬;신동훈;전영훈;이진구
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.249-252
    • /
    • 2002
  • we have studied the characteristics of PHEMT's with gate recess etching method. The DC characterization of PHTMT fabricated with the wide single recess methods is a maximum drain current density of 319.4 ㎃/mm and a peak transconductance of 336.7 ㎳/mm. The RF measurements were obtained in the frequency range of 1~50GHz. At 50GHz, 3.69dB of 521 gain were obtained and a current gain cut-off frequency(f$_{T}$) of 113 CH and a maximum frequency of oscillation(f$_{max}$) of 172 Ghz were achieved from this device. On the other hand, a maximum drain current of 367 mA/mm, a peak transconduclancc of 504.6 mS/mm, S$_{21}$ gain of 2.94 dB, a current gain cut-off frequency(f$_{T}$) of 101 CH and a maximum frequency of oscillation(f$_{max}$) of 113 fa were achieved from the PHEMT's fabricated by the .narrow single recess methods.methods.

  • PDF

Prognostic value of nodal SUVmax of 18F-FDG PET/CT in nasopharyngeal carcinoma treated with intensity-modulated radiotherapy

  • Lee, So Jung;Kay, Chul-Seoung;Kim, Yeon-Sil;Son, Seok Hyun;Kim, Myungsoo;Lee, Sea-Won;Kang, Hye Jin
    • Radiation Oncology Journal
    • /
    • v.35 no.4
    • /
    • pp.306-316
    • /
    • 2017
  • Purpose: To investigate the predictive role of maximum standardized uptake value ($SUV_{max}$) of 2-[$^{18}F$]fluoro-2-deoxy-D-glucose($^{18}F-FDG$) positron emission tomography/computed tomography (PET/CT) in nasopharyngeal cancer patients treated with intensity-modulated radiotherapy (IMRT). Materials and Methods: Between October 2006 and April 2016, 53 patients were treated with IMRT in two institutions and their PET/CT at the time of diagnosis was reviewed. The $SUV_{max}$ of their nasopharyngeal lesions and metastatic lymph nodes (LN) was recorded. IMRT was delivered using helical tomotherapy. All patients except for one were treated with concurrent chemoradiation therapy (CCRT). Correlations between $SUV_{max}$ and patients' survival and recurrence were analyzed. Results: At a median follow-up time of 31.5 months (range, 3.4 to 98.7 months), the 3-year overall survival (OS) and disease-free survival (DFS) rates were 83.2% and 77.5%, respectively. In univariate analysis, patients with a higher nodal pre-treatment $SUV_{max}$ (${\geq}13.4$) demonstrated significantly lower 3-year OS (93.1% vs. 55.5%; p = 0.003), DFS (92.7% vs. 38.5%; p < 0.001), locoregional recurrence-free survival (100% vs. 50.5%; p < 0.001), and distant metastasis-free survival (100% vs. 69.2%; p = 0.004), respectively. In multivariate analysis, high pre-treatment nodal $SUV_{max}$ (${\geq}13.4$) was a negative prognostic factor for OS (hazard ratio [HR], 7.799; 95% confidence interval [CI], 1.506-40.397; p = 0.014) and DFS (HR, 9.392; 95% CI, 1.989-44.339; p = 0.005). Conclusions: High pre-treatment nodal $SUV_{max}$ was an independent prognosticator of survival and disease progression in nasopharyngeal carcinoma patients treated with IMRT in our cohort. Therefore, nodal $SUV_{max}$ may provide important information for identifying patients who require more aggressive treatment.