• Title/Summary/Keyword: $SF_6$ Recovery

Search Result 43, Processing Time 0.022 seconds

Study on the Separation of N2/SF6 Mixture Gas Using Polyimide Hollow Fiber Membrane (폴리이미드 중공사 막을 이용한 N2/SF6 혼합기체 분리에 관한 연구)

  • Kim, Dae-Hoon;Kim, Guang-Lim;Jo, Hang-Dae;Park, Jong-Soo;Lee, Hyung-Keun
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.660-667
    • /
    • 2010
  • In this research polyimide, Matrimid 5218, hollow fiber membrane was used to recover sulfur hexafluoride($SF_6$) which is one of the six greenhouse gases from $N_2/SF_6$ mixture gas. Fibers were spun from using dry-wet phase inversion method. The module was manufactured by fabricating fibers after surface coating with silicone elastomer. The scanning electron microscopy(SEM) studies showed that the produced fibers typically had an asymmetric structure; a dense top layer supported by a sponge-like substructure. The developed module had a permeance of 0.78-1.36 GPU for $N_2$ with $N_2/SF_6$ selectivity of 2.44-5.08 at various pressure and temperature. For recovery of $SF_6$, a membrane module and 10 vol.% $SF_6$ from $N_2/SF_6$ mixture gas was used. The effects of various operating condition such as pressure, temperature, and retentate side flow rate were tested. When pressure and temperature were increased and retentate flow rate was decreased, the $SF_6$ purity in recovered gas was increased up to 37.5 vol.% with decreasing recovery ratio. When retentate flow rate was increased pressure and temperature was decreased, the $SF_6$ recovery ratio in retentate side was increased up to 89% with decreasing the $SF_6$ purity in retentate side.

Recovery of $SF_6$ gas from Gaseous Mixture ($SF_6/N_2/O_2/CF_4$) through Polymeric Membranes (고분자 분리막을 이용한 혼합가스($SF_6/N_2/O_2/CF_4$)로부터 $SF_6$의 회수)

  • Lee, Hyun-Jung;Lee, Min-Woo;Lee, Hyun-Kyung;Choi, Ho-Sang;Lee, Sang-Hyup
    • Membrane Journal
    • /
    • v.21 no.1
    • /
    • pp.22-29
    • /
    • 2011
  • During the maintenance, repair and replacement process of circuit breaker, $SF_6$ reacted with input air in arc discharge, which led to the production of by-product gases (eg, $N_2$, $O_2$, $CF_4$, $SO_2$, $H_2O$, HF, $SOF_2$, $CuF_2$, $WO_3$). Among these various by-product gases, $N_2$, $O_2$, $CF_4$ is major component. Therefore, the effective separation process is necessary to recycle the $SF_6$ gas from the mixture gas containing $N_2$, $O_2$, $CF_4$. In this study, the membrane separation process was applied to recycle the $SF_6$ gas from the mixture gas containing $N_2$, $O_2$, $CF_4$. The concentration of $SF_6$ gas in gas produced from the electric power industry is over than 90 vol%. Therefore, we made the simulated gas containing $N_2$, $O_2$, $CF_4$, $SF_6$ which the concentration of $SF_6$ gas is minimum 90 vol%. From the results of membrane separation process of $SF_6$ gas from $N_2$, $O_2$, $CF_4$ $SF_6$ mixture gases, PSF membrane shown the highest recovery efficiency 92.7%, in $25^{\circ}C$ and 150 cc/min of retentate flow rate. On the other hand, PC membrane shown the highest recovery efficiency 74.8%, in $45^{\circ}C$ and 150 cc/min of retentate flow rate. Also, the highest rejection rate of $N_2$, $O_2$, $CF_4$ is 80, 74 and 58.9% seperately in the same operation condition of highest recovery efficiency. From the results, we supposed the membrane separation process as the effective $SF_6$ separation and recycle process from the mixture gas containing $N_2$, $O_2$, $CF_4$, $SF_6$.

Application of single-well push-drift-pull tests using dual tracers (SF6 and salt) for designing CO2 leakage monitoring network at the environmental impact test site in Korea

  • Kim, Hong-Hyun;Lee, Seong-Sun;Ha, Seung-Wook;Lee, Kang-Kun
    • Geosciences Journal
    • /
    • v.22 no.6
    • /
    • pp.1041-1052
    • /
    • 2018
  • A single-well push-drift-pull tracer test using two different tracers ($SF_6$ and salt) was performed at the Environmental Impact Test (EIT) site to determine suitable locations for monitoring wells and arrange them prior to artificial $CO_2$ injection and leak tests. Local-scale estimates of hydraulic properties (linear groundwater velocity and effective porosity) were obtained at the study site by the tracer test with two tracers. The mass recovery percentage of the volatile tracer ($SF_6$) was lower than that of the non-volatile tracer (salt) and increased drift time may make degassing of $SF_6$ intensified. The $CO_2$ leakage monitoring results for both unsaturated and saturated zones suggest that the $CO_2$ monitoring points should be located near points at which a high concentration gradient is expected. Based on the estimated hydraulic properties and tracer mass recovery rates, an optimal $CO_2$ monitoring network including boreholes for monitoring the unsaturated zone was constructed at the study site.

Development on the Methodology of CDM Projects in the SF6 Recovery and Recycling of Electrical Equipment (전력설비에서의 SF6 회수 및 재활용 CDM 방법론 개발)

  • Pyo, Jeong-Gwan;Sa, Jae-Hwan;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.2 no.3
    • /
    • pp.143-159
    • /
    • 2011
  • Projects applying the CDM methodology AM0035 of the $SF_6$ Emission Reductions in Electrical Grids should provide direct monitoring of all the key parameters that are related to estimation of baseline and project emissions including detailed explanations of key operating conditions and procedures, and an explanation addressing uncertainty as the result of EB meeting 41. Through this study, recovery ratio during maintenance, purity of $SF_6$ before and after disposal, replacing, loss rate of $SF_6$ before and after reclamation, leakage emission from electricity consumption and fossil fuel combustion, considered conservatively the key parameter of various monitoring. Consequently, confirmed the reduction in the amount of reduction due to the baseline emission decrease, project emission increase.

Evaluation Method II of the Small Current Breaking Performance of SF$_6$-Blown High-Voltage Gas Circuit Breakers (초고압 $SF_6$가스차단기의 소전류 차단성능 해석기술 II)

  • 송기동;이병윤;박경엽;박정후
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.8
    • /
    • pp.384-391
    • /
    • 2001
  • The insulation strength between contacts after current interruption to the transient recovery voltage i.e., the dielectric recovery strength should be estimated for the evaluation of the small capacitive current interruption capability. Many authors have used theoretical and semi-experimental approaches to evaluate the transient breakdown voltage after the current interruption. Moreover, an empirical equation, which is obtained from a series of tests, has been used to estimated the dielectric recovery strength. Un this paper, the theoretical method which is generated from the streamer theory has been applied to real circuit breakers in order to evaluated the interruption capability. The results of analysis have been compared with the test results and the reliability has been investigated.

  • PDF

Relationship between Radiosensitivity and Repair Capacity in Human Epithelial Cancer Cell Lines (인체 상피암 세포주에서 방사선감수성과 손상회복의 상관관계에 관한 연구)

  • Koh, Kyoung-Hwan;Ha, Sung-Whan;Park, Charn-Il
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.17-27
    • /
    • 1993
  • To investigate the relationship between radiosensitivity and postirradiation recovery in human cancer cells, a study was performed using human cancer cell lines-A549, CaSki, SNU-C5 and PCI-13. For the study of radiosensitivity, single doses of 2, 4, 6, 8, 10, 12, and 14 Gy were given and for postirradiation recovery, two fractions of 4 Gy were separated with a time interval of 0, 0.5, 1, 1.5, 2, 2.5, 3, 4, 5, or 6 hours. Surviving fraction was estimated using colony forming ability. Surviving fractions at 2 Gy (SF2) were 0.496 (0.570-0.412) for A549, 0.496 (0.660-0.332) for CaSki, 0.386 (0.576-0.216) for SNU-C5, and 0.185 (0.247-0.123) for PCI-13. By statistical analysis the SF2 of PCI-13 was lower significantly than those of others (p<0.05). This difference was also observed at 4, 6 and 8 Gy dose levels. At 6 and 8 Gy the surviving fractions of SNU-C5 were also lower significantly than A549 and CaSki (p<0.05). By the analysis with linear quadratic model, the values of ${\alpha}$ for A549, CaSki, SNU-C5 and PCI-13 were 0.3016, 0.3212, 0.4327 and 0.8423, respectively, and those of ${\beta}$ were 0.02429, 0.02009, 0.03349 and 0.00059, respectively. So, the value of ${\alpha}$ showed increasing tendency with decreasing SF2. By the multitarget single hit model the values of Do for A549, CaSki, SUN-C5 and PCI-13 were 1.97, 1.97, 1.46 and 0.81, respectively, and those of n were 1.53, 1.50, 1.56 and 2.28, respectively. So, the value of Do decreased with decreasing SF2. Post-irradiation recovery reached plateau at around 2 hours. Recovery ratio at plateau phase ranged from 1.2 to 4.2; the value were 1.2 for PCI-13, 3.2 for CaSki, 3.3 for SNU-C5, and 4.2 for A549. Recovery rate well correlated with SF2, and increased with increasing Do and decreasing ${\alpha}$. According to above results, the intrinsic radiosensitivity was quite different among the tested cell lines; PCI-13 was the most sensitive and A549 and CaSki was similar. This difference of radiosensitivity is thought to be partly due to the difference in amount of postirradiation recovery. By linear quadratic model the difference of ${\alpha}$ values was very high, and by multitarget single hit model the difference of Do value was significantly high among four cell lines.

  • PDF

Preparation and Characterization of Mixed-matrix Membranes Containing MIL-100(Fe) for Gas Separation (MIL-100(Fe)를 함유한 혼합기질막(mixed-matrix membranes, MMMs)의 제조 및 기체 투과 특성 연구)

  • Song, Hye Rim;Nam, Seung Eun;Hwang, Young Kyu;Chang, Jong San;Lee, U Hwang;Park, You In
    • Membrane Journal
    • /
    • v.23 no.6
    • /
    • pp.432-438
    • /
    • 2013
  • Mixed-matrix membranes (MMMs) containing MIL-100(Fe), a MOF type, were fabricated in this study. MMMs up to 30 wt% MOF loading were prepared, and their gas permeabilities were tested. $H_2$, $CO_2$, $O_2$, $N_2$, and $CH_4$ gas permeabilities increased with the MOF loading, while $SF_6$, the largest kinetic diameter in this study, exhibited reduction of gas permeability with the loading. Ideal gas selectivity of $N_2/SF_6$ improved by 40% as compared with pure polyimide membrane, suggesting the proposed MMMs were suitable for $N_2/SF_6$ separation.

Evaluation of Small Current Breaking Performance for 245kV GCB with or without Shield (쉴드 유무에 따른 245kV GCB의 소전류차단성능 평가)

  • Song T. H.;Lee H. G.;Kim Y. P.;Yoon J. H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.824-826
    • /
    • 2004
  • 상용 CFD(Computational Fluid Dynamics) 프로그램인 PHOENICS를 이용하여 245kV $SF_6$ 가스 차단기의 진상소전류 차단성능을 평가하였다. 소전류 차단시에는 아크가 발생 즉시 소호되므로 $SF_6$ 가스를 전리가 일어나지 않은 냉가스로 취급할 수 있다. 그러므로 PHOENICS를 이용하여 극간의 $SF_6$ 가스밀도 및 전계의 변화를 계산하였으며 이것으로부터 극간 $SF_6$ 가스의 절연내력(Dielectric Strength)을 계산하였다. 계산된 $SF_6$ 가스의 절연내력과 아크 소호 후 극간에 인가되는 회복전압(Recovery Voltage)을 비교하여 차단기의 진상소전류 차단성능을 평가하였다. 245kV 차단기에는 전계를 완화하기 위한 목적으로 차단부에 쉴드가 설치되어 있으며 이 쉴드에 의한 소전류차단성능의 변화를 해석하였다.

  • PDF

Study on the Gas Separation of Carbon Molecular Sieve (CMS) Membrane for Recovering the Perfluorocompound Gases from the Electronics Industry (전자산업 배출 불화가스 회수를 위한 탄소분자체 분리막의 기체분리 연구)

  • Jeong, Su Jung;Lim, Joo Hwan;Han, Sang Hoon;Koh, Hyung Chul;Ha, Seong Yong
    • Membrane Journal
    • /
    • v.26 no.3
    • /
    • pp.220-228
    • /
    • 2016
  • Carbon molecular sieve (CMS) hollow fiber membranes were prepared by carbonizing a polyimide precursor manufactured by non-solvent induced phase separation process. Gas separation performance of CMS hollow fiber membrane was investigated on the effect of three carbonization conditions. CMS membrane with the highest gas separation performance was obtained at the pyrolysis temperature of $250-450^{\circ}C$: $N_2$, $SF_6$, and $CF_4$ permeance were 20, 0.32, 0.48 GPU, respectively, and $N_2/SF_6$ and $N_2/CF_4$ selectivities were 62 and 42, respectively. In the $SF_6/CF_4/N_2$ mixture gas test, when the stage cut was 0.2, the recovery ratio of $SF_6$ and $CF_4$ was over 99% and 98%. $SF_6$ concentration ratio was 4.5 times higher than the $SF_6$ concentration at the feed side. From the results, it was concluded that CMS membrane was one of the promising membranes for recovery Perfluorocompound gases process.

Evaluation Method I of the Small Current Breaking Performance for SF(sub)6-Blown High-Voltage Gas Circuit Breakers (초고압 $SF_6$ 가스차단기의 소전류 차단성능 해석기술 I)

  • 송기동;이병운;박경엽;박정후
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.7
    • /
    • pp.331-337
    • /
    • 2001
  • With the increasing reliability of analysis schemes and the dramatically increased calculating speed, the computer simulation has become and indispensable process to predict the interruption capacity of circuit breakers. Generally, circuit breakers have to possess both the small current and large current interruption abilities and the circuit breaker designers need to evaluate its capacities to save the time and the expense. The analysis of small current and the large current interruption performances have been considered separately because the phenomena occurring in a interrupter are quite different. To analyze the dielectric recovery after large current interruption many physical phenomena such as heat transfer, convection and arc radiation, the nozzle ablation, the ionization of high temperature SF(sub)6 gas, the electric and themagnetic forces and so forth mush be considered. However, in the analysis of small current interruption performance only the cold gas flow analysis needs to be carried out because the capacitive current is to small that the influence from the current can be neglected. In this paper, an empirical equation which is obtained from a series of tests to estimate the dielectric recovery strength has been applied to a real circuit breaker. The results of analysis have been compared with the test results and the reliability has been investigated.

  • PDF