• 제목/요약/키워드: $R_max$

검색결과 925건 처리시간 0.027초

Wireless TDD Time Synchronization Technique Considering the Propagation Delay Between Mobile Vehicles (이동체간 전파지연을 고려한 무선 TDD 시각 동기화 기법)

  • Boo, Jung-il;Ha, Jeong-wan;Kim, Kang-san;Kim, Bokki
    • Journal of Advanced Navigation Technology
    • /
    • 제23권5호
    • /
    • pp.392-399
    • /
    • 2019
  • In this paper, we have studied wireless time division duplex(TDD) time synchronization technique considering the propagation delay between mobile vehicles. The existing IEEE 1588 precision time protocol(IEEE 1588 PTP) algorithm was applied and the time synchronization between the two nodes was achieved through the propagation delay and clock offset time correction calculated between master slave nodes during wireless TDD communication. The time synchronization process and procedure of IEEE 1588 PTP algorithm were optimized, thereby reducing the propagation delay error sensitivity for real-time moving vehicles. The sync flag signal generated through the time correction has a time synchronization accuracy of max +252.5 ns within 1-symbol(1.74 M symbol/sec, ${\pm}287.35ns$) through test and measurement, and it was confirmed that the time synchronization between master slave nodes can be achieved through sync flag signal generated during GPS disturbance.

The Effect of Volume Reduction on Computed Treatment Planning during Head and Neck IMRT and VMAT (두경부 IMRT 및 VMAT 시 체적 감소가 전산화치료계획에 미치는 영향)

  • Ki-Cheon Um;Gha-Jung Kim;Geum-Mun Back
    • Journal of radiological science and technology
    • /
    • 제46권3호
    • /
    • pp.239-246
    • /
    • 2023
  • In this study, we assessed the effect of reduction of tumor volume in the head and neck cancer by using RANDO phantom in Static Intensity-Modulated Radiation Therapy (S-IMRT) and Volumetric-Modulated Arc Therapy (VMAT) planning. RANDO phantom's body and protruding volumes were delineated by using Contour menu of Eclipse™ (Varian Medical System, Inc., Version 15.6, USA) treatment planning system. Inner margins of 2 mm to 10 mm from protruding volumes of the reference were applied to generate the parameters of reduced volume. In addition, target volume and Organ at Risk (OAR) volumes were delineated. S-IMRT plan and VMAT plan were designed in reference. These plans were assigned in the reduced volumes and dose was calculated in reduced volumes using preset Monitor unit (MU). Dose Volume Histogram (DVH) was generated to evaluate treatment planning. Conformity Index (CI) and R2 in reference S-IMRT were 0.983 and 0.015, respectively. There was no significant relationship between CI and the reduced volume. Homogeneity Index (HI) and R2 were 0.092 and 0.960, respectively. The HI increased when volume reduced. In reference VMAT, CI and R2 were 0.992 and 0.259, respectively. There was no relationship between the volume reduction and CI. On the other hand, HI and R2 were 0.078 and 0.895, respectively. The value of HI increased when the volume reduced. There was significant difference (p<0.05) between parameters (Dmean and Dmax) of normal organs of S-IMRT and VMAT except brain stem. Volume reduction affected the CI, HI and OAR dose. In the future, additional studies are necessary to incorporate the reduction of the volume in the clinical setting.

Analysis of Apparatus Variables for Deformation Strength Test of Asphalt Concrete Based on Correlation with Rutting and Prediction Model for Rutting (소성변형과의 상관성 및 추정모델을 통한 변형강도 시험장치 변수 분석)

  • Kim, Kwang-Woo;Lee, Moon-Sup;Kim, Sung-Tae;Lee, Soon-Jae
    • International Journal of Highway Engineering
    • /
    • 제4권4호
    • /
    • pp.41-52
    • /
    • 2002
  • This study dealt with analysis of size effect of testing apparatus for Kim test which measures rut resistance characteristics of asphalt mixture under static loading. Two columns in different diameter with each column having different radios of round cut (Curvature) at the bottom were used for testing asphalt mixture. Deformation load ($P_{max}$) and deformation strength ($K_D$) were found to have relatively high correlation with rut depth and dynamic stability of asphalt concrete. Diameter of specimen was not a significant factor in this test. From the statistical correlation analysis with rutting properties, the radius of curvature and diameter of loading column were found to be important factor affecting the results of the test. Among the radios (r) of curvatures, r=0.5cm and 1.0cm showed much higher correlation than the column without curvature, and r=1.0cm being better between the two. The column with diameter of 4cm showed better correlation than diameter of 3cm. Therefore, the column of 4cm diameter with r=1.0cm was found to be the best among various apparatus sizes. Prediction models for rut depth and dynamic stability were developed for each aggregate mixture based on Kim test variables using SAS STEPWISE procedure. Therefore, if this test method is validated through further study, Kim test can be used for selecting asphalt mixture with the highest resistance against permanent deformation.

  • PDF

Dielectric and Piezoelectric Properties of Microwave Sintered BNT-ST Ceramics (마이크로파 소성법으로 제조한 BNT-ST 세라믹스의 유전 및 압전 특성)

  • Lee, Sang-Hun;Kim, Seong-Hyun;Erkinov, Farrukh;Nguyen, Hoang Thien Khoi;Duong, Trang An;Han, Hyoung-Su;Lee, Jae-Shin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제33권1호
    • /
    • pp.37-44
    • /
    • 2020
  • This study investigated the microstructure and piezoelectric properties of lead-free 0.74(Bi1/2Na1/2)TiO3-0.26SrTiO3 (BNST26) piezoelectric ceramics sintered using a microwave furnace. For comparison, specimens were also prepared using a conventional furnace sintering (CFS). Average grain sizes of 2.4 ㎛ and 3.2 ㎛ were obtained in the sample sintered at 1,100℃ for 5 min using microwave sintering (MWS) and at 1,175℃ for 2 h using CFS, respectively. To quantify the changes in the microstructures and electrical properties according to the sintering conditions, the polarization hysteresis, bipolar and unipolar strain curves, and temperature dependence of permittivity were evaluated. As a result, it was determined that the Pmax (maximum polarization), Pr (remanent polarization) and Smax (maximum strain) values tend to increase with the average grain size. Based on these results, it is concluded that the MWS method can produce lead-free ceramics with superior performance in a relatively short time compared to the conventional CFS method.

A Study on the Fabrication for High Quality Ferrite Plastic Magnets (고품위 페라이트 본드자석 제조에 관한 연구)

  • 신용진;문형욱;진성빈;정왕일
    • Electrical & Electronic Materials
    • /
    • 제10권5호
    • /
    • pp.440-446
    • /
    • 1997
  • This research has been performed for the fabrication of high quality ferrite plastic magnet. The magnetic properties of S $r_{5.9}$F $e_2$ $O_3$ ferrite bonded magnets by injection moulding with a variety of applied magnetic field were investigated. 0.3wt% CaCO3, 0.2wt% $SiO_2$, 0.5wt% $Al_2$ $O_3$and 0.5wt% N $a_2$ $SiO_3$are added in order to improve the magnetic properties of Sr-ferrite plastic magnets during the powder fabrication. For carbon coating on chemical compound specimen, 5wt% polyvinyl alcohol is added, and then calcinated under $N_2$ environment of 12$25^{\circ}C$. The particle size is distributed from 0.9~1.2${\mu}{\textrm}{m}$ which approximates to the single domain. The obtained Sr ferrite powder is well mixed with silane coupling and calcium stearate of 1wt%. Nest, the specimen is pelleted after kneading each of them with polyamidel2 as a binder. When the temperature of injection and mould were 25$0^{\circ}C$ and 8$0^{\circ}C$ respectively at injection pressure of 200kgf/$\textrm{cm}^2$, the degree of orientation was 85.3% under the applied magnetic field of 12kOe. As the results, when the packing density of Sr ferrite powder was 90wt%, the magnetic properties of Sr ferrite bonded magnet were follows : $_{B}$ $H_{c}$=2.41kOe, Br=3.1kG, (BH)$_{max}$=2.21MgOe. Especially, the Sr-ferrite bonded magnet with 10wt% N $d_2$F $e_{14}$B additive were as follows : $_{B}$ $H_{c}$=2.57kOe, Br=3.14kG and (BH)$_{max}$=2.39MGOe.GOe.GOe.GOe.e.

  • PDF

DC and RF Characteristics of AlGaN/InGaN HEMTs Grown by Plasma-Assisted MBE (AlGaN/InGaN HEMTs의 고성능 초고주파 전류 특성)

  • 이종욱
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제15권8호
    • /
    • pp.752-758
    • /
    • 2004
  • This paper reports on the DC and RF characteristics of AlGaN/InGaN/GaN high electron-mobility transistors (HEMTs) grown by molecular beau epitaxy(MBE) on sapphire substrates. The devices with a 0.5 ${\mu}$m gate-length exhibited relatively flat transconductance(g$\_$m/), which results from the enhanced carrier confinement of the InGaN channel. The maximum drain current was 880 mA/mm with a peak g$\_$m/ of 156 mS/mm, an f$\_$T/ of 17.3 GHz, and an f$\_$MAX/ or 28.7 GHz. In addition to promising DC and RF results, pulsed I-V and current-switching measurements showed little dispersion in the unpassivated AlGaN/InGaN HEMTs. These results suggest that the addition of In to the GaN channel improves the electron transport characteristics as well as suppressing current collapse that is related to the surface trap states.

Effects of Baseline Selection on Magnetocardiography: P-Q and T-P Intervals (심자도의 P-Q 구간과 T-P 구간에서 설정한 베이스 라인의 효과에 대한 연구)

  • Lim, Hyun-Kyoon;Kwon, Hyuk-Chan;Kim, Tae-En;Lee, Yong-Ho;Kim, Jin-Mok;Kim, In-Seon;Kim, Ki-Woong;Park, Yong-Ki
    • Progress in Superconductivity
    • /
    • 제9권1호
    • /
    • pp.29-34
    • /
    • 2007
  • The baseline selection is the first and important step to analyze magnetocardiography (MCG) parameters. There are no difficulties to select the baseline between P- and Q-wave peak (P-Q interval) of MCG wave recorded from healthy subjects because the P-Q intervals of the healthy subjects do not much vary. However, patients with ischemic heart disease often show an unstable P-Q interval which does not seem to be appropriate for the baseline. In this case, T-P interval is alternatively recommended for the baseline. However, there has been no study on the difference made by the baseline selection. In this study, we studied the effect of the different baseline selection. MCG data were analyzed from twenty healthy subjects and twenty one patients whose baselines were alternatively selected in the T-P interval for their inappropriate P-Q interval. Paired T-test was used to compare two set of data. Fifteen parameters derived from the R-wave peak, the T-wave peak, and the period, $T_{max/3}{\sim}T_{max}$ were compared for the different baseline selection. As a result, most parameters did not show significant differences (p>0.05) except few parameters. Therefore, there will be no significant differences if anyone of two intervals were selected for the MCG baseline. However, for the consistent analysis, P-Q interval is strongly recommended for the baseline correction.

  • PDF

A Study on the Development of the Seeder for Soybean and Corn (콩.옥수수 육묘용 파종기 개발에 관한 연구)

  • Kim, Dong-Eok;Kim, Hyun-Hwan;Kim, Jong-Goo;Lee, Gong-In;Kim, Sung-Ki;Chang, Yu-Seob
    • Journal of Biosystems Engineering
    • /
    • 제35권5호
    • /
    • pp.330-335
    • /
    • 2010
  • Soybean (Glycine max Merr.) and corn (Zea mays L.) transplanting has increased because soybean and corn crops cultivated by the direct seeding method were often damaged by wild birds. The purpose of this study is to develop a seeder to sow soybean (Glycine max Merr.) and corn (Zea mays L.) in a plug tray. In order to find out design factors for a metering device of the seeder, metering characteristics on metering hole size and roller speed were experimentally investigated. Soybean (cv. 'Daewon') and corn (cv. 'Mibaekchal') were used as a materials for testing the seeder in this experiment. The metering hole size of roller suitable for Daewonkong and Mibaekchal was determined. Daewonkong was suitable for hole diameter of 10 mm and hole depth of 5.5 mm, and Mibaekcal was suitable for hole diameter of 9 mm and hole depth of 5.5 mm. At a brush length of 4 mm, one grain seeding rates of Daewonkong and Mibaekchal was 99% and 93% respectively. By inducing Mibaekchal to the hole by swing, one grain seeding rate of that increased from 91.9% to 97.7%. When roller speed is 4 m per minut, seeding efficiency of prototype was 110 sheets per hour.

Bioavailability Test of TestoTM Tablets (Methyltestosterone, 25 mg) in Male Healthy Volunteers by a Gas-chromatography/Mass Selective Detector

  • Kwon, Oh-Seung;Kim, Hye-Jung;Pyo, Hee-Soo;Kim, Dae-Duk;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권5호
    • /
    • pp.383-388
    • /
    • 2005
  • A simple and specific method for determination of methyltestosterone (MT) has been established by a gas chromatography/mass selective detector and applied in plasma of healthy male volunteers received a single oral dose of 50 mg MT $(Testo^{TM}\;tablets,\;25\;mg)$ for bioavailability test. This method involves using liquid-liquid extraction of the sample with diethyl ether and derivatization with MSTFA. MT showed good resolution in this condition. The detection limit of quantitation was 5 ng/ml. A good linearity (r>0.996) was obtained at the range of 5-250 ng/ml of MT. Intra-day precision and accuracy were 2.76-12.56% and 0.39-8.01 %, and inter-day precision and accuracy were 2.29-17.69% and 0.42-7.99%, respectively. The established method was applied on bioavailability test of MT in human volunteers. The value of $AUC_{0\;to\;last}$ to last was $264.5{\pm}123.9\;ng{\cdot}hr/ml$ and that of $AUC_{0\;to\;inf}$ was determined to be $275.2{\pm}126.5\;ng{\cdot}hr/ml$. The values of $C_{max}$ and $T_{max}$ were $95.9{\pm}67.1\;ng/ml$ and $1.13{\pm}0.9\;hr$, respectively. The mean elimination half-life $(t_{1/2})$ was $4.4{\pm}0.9\;hr$. This analytical method is suitable and useful for the pharmacokinetics and bioequivalence studies of MT.

Development of Controlled Release Oral Drug Delivery System by Membrane-Coating Method-II-Correlation Between Acetaminophen Concentrations in Plasma and Sativa Samples of Man- (피막법에 의한 경구투여용 제어방출 제제의 개발-II-사람에 있어서 아세트아미노겐 혈장 중 농도와 타액 중 농도와의 상관성-)

  • Shim, Chang-Koo;Kim, Mi-Ae;Lee, Min-Hwa;Kim, Shin-Keun
    • Journal of Pharmaceutical Investigation
    • /
    • 제20권1호
    • /
    • pp.29-33
    • /
    • 1990
  • Plasma and saliva concentrations of acetaminophen (AAP) were determined at various time points by HPLC after oral administration of AAP tablets (AAP 500 mg) to four healthy male Korean subjects. Saliva concentrations (S) of AAP were significantly correlated with plasma AAP concentrations (P). The S/P ratio of AAP was calculated to be 1.05 (r =0.944, $p<10^{-6}$) for all the data points from the subjects. It showed a little intersubject variation and ranged from 0.89 to 1.46 in each subject. Bioavailability parameters such as AUC, $C_{max}$ and $T_{max}$ which are usually obtained from the plasma concentration data will be predictable approximately by saliva concentration data. Saliva seems to be very convinient and useful samples for the preliminary studies of bioavailability and bioequivalence of AAP preparations, since it can be collected frequently without any painful venipuncture to the subjects, that is inevitable in plasma sampling. Evaluation of the bioavailability of a preparation by saliva samples will reduce the cost, time and safety risk greatly in developing a new drug delivery system for AAP.

  • PDF