• 제목/요약/키워드: $PM_{10}$ in Korea

검색결과 6,502건 처리시간 6.085초

Chronic Renal Failure in Children: A Nationwide Survey in Korea (소아 만성 신부전증의 전국적인 조사연구)

  • Kim, KyoSun;Jeon, Jeong-Sik;Lee, Ik-Jun;Go, Dae-Gyun;Lee, Gyeong-Il;Yun, Hui-Sang;Gu, Ja-Hun;Go, Cheol-U;Jo, Byeong-Su;Kim, Jun-Sik;Son, Chang-Seong;Yu, Gi-Hwan;An, Yeong-Ho
    • Childhood Kidney Diseases
    • /
    • 제4권2호
    • /
    • pp.92-101
    • /
    • 2000
  • Purpose : We analyzed the demogaphic data md clinical course of Korean children with chronic renal failure (CRF) observed between 1990 and 1999. Patients and Methods : Questionnaires were mailed to all children's hospitals ail through the country. We asked for primary renal disease age and serum creatinine levels at first presentation with CRF and end-stage renal disease (ESRD), and modes of renal replacement therapy (RRT). Results : 401 children (254 boys, 147 girls) with CRF, defined as a permanent increase of serum creatinine above 1.2 mg/dl for at least 3 months or until death, were identified. This represents an incidence of 3.68 per million child population per year. Of these patients, 22$\%$ on younger than 5 years, 28$\%$ 5 to 10 years and 50$\%$ 10 to 15 year. Eight five $\%$ of the patients could be classified with a primary renal disease. The most frequent cause is glomerulonephritis (36$\%$), followed by chronic pyelonephritis (21$\%$), renal hrpo/dylplasia (9$\%$), and hereditary nephropathies (7$\%$). Reflux nephropathy (16$\%$) was the most common single cause of CRF. ESRD was reached in 70$\%$ of all patient. 99.3$\%$ of these started RRT. Hemodialysis (HD, 42$\%$), peritoneal dialysis (PD, 35$\%$) and transplantation (TP, 23$\%$) were performed as the initial mode of RRT. A total of 161 TPs were performed (159 first grafts, 2 second grafts). A total of 32 patients died. The main causes of death were dialysis related complication in HD patients and infections in PD patients. Survival rate on any form of RRT was 88.7$\%$ during the mean follow-up period of 37 months. Conclusion Major efforts should be directed toward earlier diagnosis and treatment of reflux nephropathy to prevent occurrence of Of. Dialysis and TP have now become well accepted forms of treatment in Korean children with ESRD.

  • PDF

Effect of Diet Containing Whole Wheat Bread with Capsosiphon fulvescens and Lindera obtusiloba Ethanol Extracts on Plasma Glucose and Lipid Levels in Rats (매생이와 생강나무잎 에탄올 추출물이 첨가된 통밀빵을 섭취한 랫트의 혈당과 지질수준에 미치는 영향)

  • Han, Ah-Ram;Kim, Se-Wook;Chun, Su-Hyun;Nam, Mi-Hyun;Hong, Chung-Oui;Kim, Bok Hee;Kim, Tae Cheol;Lee, Kwang-Won
    • Korean Journal of Food Science and Technology
    • /
    • 제48권2호
    • /
    • pp.178-186
    • /
    • 2016
  • The present study was conducted to investigate the effect of whole wheat bread with added Lindera obtusiloba (LO) and Capsosiphon fulvescens (CF) ethanol extracts on serum glucose and lipid levels in Sprague Dawley rats. Rats were divided into five groups depending on the diet administered: normal bread (NC), whole wheat bread (W), whole wheat bread with LO leaves extract (WL), whole wheat bread with CF extract (WC), and whole wheat bread with freeze-drying CF (WDC). After 4 weeks of consuming the experimental diet, the blood glucose level and hemoglobin A1c contents were found to be significantly lower in the W, WL, WC, and WDC groups than in the NC group. The high-density lipoprotein-cholesterol levels increased in the WL group when compared to those in the NC group and triglycerides levels decreased in all wheat groups compared to those in the NC group. These results suggest that wheat breads containing LO and CF extracts are effective for preventing hypercholesterolemia and obesity.

Effect of Water Temperature on Ammonia Excretion of Juvenile Pacific Cod Gadus macrocephalus (대구 Gadus macrocephalus 치어의 암모니아 배설에 미치는 수온의 영향)

  • Oh, Sung-Yong;Park, Heung-Sik;Noh, Choong-Hwan
    • Korean Journal of Ichthyology
    • /
    • 제22권3호
    • /
    • pp.147-153
    • /
    • 2010
  • A study was carried out to examine the effect of water temperature on daily pattern and rate of total ammonia nitrogen (TAN) excretion in juvenile Pacific cod Gadus macrocephalus (mean body weight: $36.5{\pm}0.8\;g$) under fasting and feeding conditions. Fish were acclimated over 10 days under three different water temperatures (9, 11 and $13^{\circ}C$), and transferred to TAN measuring system under each water-temperature condition. After 72 hours of starving, fasting TAN excretion was measured at each temperature. To investigate post-prandial TAN excretion, fish were hand-fed with a commercial diet containing 40.6% crude protein for 7 days, two times daily at 08:00 and 16:00 h. Water was sampled from both the inlet and outlet of the fish chamber every 2 h over a 24-h period. Both fasting and post-prandial TAN excretion increased with increased water temperatures (p<0.05). Mean fasting TAN excretion rates at 9, 11 and $13^{\circ}C$ were 9.3, 11.0 and $11.9\;mg\;TAN\;kg\;fish^{-1}\;h^{-1}$, respectively. The value of $9^{\circ}C$ was lower than those of 11 and $13^{\circ}C$ (p<0.05), but there was no significant difference between $11^{\circ}C$ and $13^{\circ}C$. Mean post-prandial TAN excretion rates at 9, 11 and $13^{\circ}C$ were 23.0, 31.6 and $45.4\;mg\;TAN\;kg\;fish^{-1}\;h^{-1}$, respectively. A peak value of post-prandial TAN excretion rate occurred after 2 h from each feeding, and the second value is always higher than the first value. Maximum post-prandial TAN excretion rate occurred after 10 h from the first feeding at $9^{\circ}C$ (mean $38.0\;mg\;TAN\;kg\;fish^{-1}\;h^{-1}$), $11^{\circ}C$ ($52.9\;mg\;TAN\;kg\;fish^{-1}\;h^{-1}$) and $13^{\circ}C$ ($77.5\;mg\;TAN\;kg\;fish^{-1}\;h^{-1}$), respectively. The TAN loss for ingested nitrogen at $9^{\circ}C$ (43.9%) was lower than those of $11^{\circ}C$ (46.4%) and $13^{\circ}C$ (48.4%). The overall results indicate that water temperature exhibits a significant effect on the nitrogen excretion of juvenile Pacific cod.

A Multicenter Study of Pertussis Infection in Adults with Coughing in Korea: PCR-Based Study

  • Park, Sunghoon;Lee, Myung-Gu;Lee, Kwan Ho;Park, Yong Bum;Yoo, Kwang Ha;Park, Jeong-Woong;Kim, Changhwan;Lee, Yong Chul;Park, Jae Seuk;Kwon, Yong Soo;Seo, Ki-Hyun;Kim, Hui Jung;Kwak, Seung Min;Kim, Ju-Ock;Lim, Seong Yong;Sung, Hwa-Young;Jung, Sang-Oun;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • 제73권5호
    • /
    • pp.266-272
    • /
    • 2012
  • Background: Limited data on the incidence and clinical characteristics of adult pertussis infections are available in Korea. Methods: Thirty-one hospitals and the Korean Centers for Disease Control and Prevention collaborated to investigate the incidence and clinical characteristics of pertussis infections among adults with a bothersome cough in non-outbreak, ordinary outpatient settings. Nasopharyngeal aspirates or nasopharyngeal swabs were collected for polymerase chain reaction (PCR) and culture tests. Results: The study enrolled 934 patients between September 2009 and April 2011. Five patients were diagnosed as confirmed cases, satisfying both clinical and laboratory criteria (five positive PCR and one concurrent positive culture). Among 607 patients with cough duration of at least 2 weeks, 504 satisfied the clinical criteria of the US Centers for Disease Control and Prevention (i.e., probable case). The clinical pertussis cases (i.e., both probable and confirmed cases) had a wide age distribution ($45.7{\pm}15.5$ years) and cough duration (median, 30 days; interquartile range, 18.0~50.0 days). In addition, sputum, rhinorrhea, and myalgia were less common and dyspnea was more common in the clinical cases, compared to the others (p=0.037, p=0.006, p=0.005, and p=0.030, respectively). Conclusion: The positive rate of pertussis infection may be low in non-outbreak, ordinary clinical settings if a PCR-based method is used. However, further prospective, well-designed, multicenter studies are needed.

Analysis on the Causes of the Oil Leakage Phenomenon for Complex Waterproofing Methods of Asphalt Mastic and Modified Asphalt Sheet (콘크리트 구조물에 사용되는 개량아스팔트 시트와 아스팔트 매스틱을 복합화한 방수공법의 누유현상 원인 분석)

  • Park, Jin-Sang;Kim, Dong-Bum;Park, Wan-Goo;Oh, Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • 제18권4호
    • /
    • pp.337-345
    • /
    • 2018
  • In this study, observations of oil leakage samples taken from the actual site were performed to identify the causes of the oil leakage phenomenon. As a result, the separation of the material components was determined as the main cause of the oil leakage phenomenon based on the changes in the surface conditions, and verification of this was conducted. The evaluation results confirmed that the filler component of the asphalt mastic subsided with the lapse of the settling time, and that the difference ratio of the filler contents of the upper and lower specimens was up to 23.8% after day 28. Based on these results, a hypothesis on the oil leakage mechanism of asphalt mastic was established, and then modeling of the entire process of oil leakage was performed.

Sanitary Quality Characterization of Commercial Salted Semi-dried Brown Croaker (시판 반염건 민어의 위생학적 품질 특성)

  • Heu, Min Soo;Park, Kwon Hyun;Kim, Ki Hyun;Kang, Sang In;Choi, Jong-Duck;Kim, Jin-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • 제43권4호
    • /
    • pp.584-591
    • /
    • 2014
  • Salted semi-dried brown croaker, Miichthys miiuy, has been proposed as a palatable seafood in Korea due to its specific texture, taste, and nutritional content. This study was conducted to characterize the sanitary quality of commercial salted semi-dried brown croaker for the development of high quality salted semi-dried products. The chemical properties ranged from 64.2 to 77.1% (mean $74.7{\pm}3.5%$) for moisture content, from 2.1 to 9.5% for salinity, from 14.1 to 58.1 mg/100 g for volatile basic nitrogen, and from 19.1 to 107.2 meq/kg for peroxide values. The viable cell counts and Escherichia coli were 4.2~8.3 log(CFU/g) [mean: 6.2 log(CFU/g)] and 18>~4.6 log(MPN/100 g), respectively. The chemical and microbial results of commercial salted semi-dried brown croaker suggest that provisions should be established for development of high quality salted semi-dried products.

The effects of face velocity and path length on the uptake rates of volatile organic compounds measured by diffusive samplers (확산포집기로 공기중 ppb 농도수준의 휘발성유기물질 포집시 확산길이와 기류변화가 시료포집속도에 미치는 영향)

  • Byeon, Sang-Hoon;Stock, Thomas H.;Morandi, Maria T.;Afshar, Masoud;Cross, Jay
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • 제11권1호
    • /
    • pp.34-41
    • /
    • 2001
  • Passive samplers have been used for personal, indoor, and outdoor air monitoring of VOCs at ppb concentrations in community and office environments. The path length of modified passive sampler was shortened, so it was intended to increase an uptake rate. The performance of the modified 3M 3500 organic vapor monitor(OVM) as a tool for assessing exposures to toxic air pollutants in nonoccupational community environments was evaluated using combined controlled test atmospheres of six selected target volatile organic compounds(VOCs): benzene, methyl tert-butyl ether(MTBE), chloroform, 1,4-dichlorobenzene, tetrachloroethylene, and toluene. The experiments were conducted by exposing the dosimeters to concentrations of $50{\sim}100{\mu}g/m^3$ on six face velocity(0.00, 0.02, 0.06, 0.12, 0.20, 0.30 m/sec) for 24 hours. If the uptake rate was increased, that means that we could use the passive sampler more effectively. The uptake rates were increased linearly according to reduce the path length. Although the diffusion path length was shortened, the change of uptake rate was within ${\pm}25%$ of theoretical value, indicating that the modified passive sampler(TM) can be effectively used over the range of concentrations and environmental conditions tested with a 24-h sampling period if the face velocities were over 0.12 m/s for 6 components of VOCs. But when the face velocities were less than 0.12 m/s, uptake rates were reduced more than expected values. So, the passive sampler with the shortened path length should be used at indoor or outdoor environment where the face velocity should be over about 0.10 m/s. If the path length was shortened more, the uptake rate was more effected by starvation.

  • PDF

Research and Policy Directions against Ambient Fine Particles (초미세먼지 문제 해결을 위한 연구 및 정책 방향)

  • Kim, Yong Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제33권3호
    • /
    • pp.191-204
    • /
    • 2017
  • Concerns on the air pollution problem caused by ambient fine particles have become a big social issue in Korea. Important factors that should be addressed to develop effective and efficient air quality management policy, especially, against fine particles are discussed and research and policy directions to address these factors are suggested. It is suggested that two factors are in high priority; one is scientific understanding of the major formation mechanisms of fine particles and the other is the process of policy decision and implementation. For the scientific understanding, smog chamber measurement, intensive field study, and chemical transport model development that can simulate the characteristics of Northeast Asia are considered to be important. For the policy directions, priority setting of the proposed policies and development and implement of effective communication sytem are considered to be important.

Bioequivalence of Cepirin Capsule to Suprax Capsule (Cefixime 100 mg) (슈프락스 캅셀 (세픽심 100 mg)에 대한 세피린 캅셀의 생물학적 동등성)

  • Jeong, Eun-Ju;Kang, Won-Ku;Kwon, Kwang-Il
    • Journal of Pharmaceutical Investigation
    • /
    • 제29권2호
    • /
    • pp.145-149
    • /
    • 1999
  • Bioequivalence of two cefixime capsules, test drug ($Cepirin^R$ capsule: Cheiljedang Corp.) and reference drug ($Suprax^R$ capsule: Dong A Pharm. Com.), was evaluated according to the guidelines of Korea Food and Drug Administration (KFDA). Sixteen healthy volunteers were divided randomly into two groups and administered the drug orally at the dose of 400 mg as cefixime in a $2{\times}2$ crossover study. There was a 1-week washout period between the administrations. Blood samples were taken at predetermined time intervals for 12 hour and the plasma concentration of cefixime was determined with a HPLC method. $AUC_{0-12hr}$ (area under the plasma concentration-time curve form time zero to 12 hour), $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were estimated from the plasma drug concentrationtime data. Analysis of variance (ANOVA) revealed no difference in $AUC_{0-12hr}$, $C_{max}$ and $T_{max}$ between the formulations. The apparent differences of these parameters between the formulations were less than 20% (i.e., 8.62, 11.10 and 0.00% for $AUC_{0-12hr}$, $C_{max}$ and $T_{max}$,respectively). The powers $(1-{\beta})$ for $AUC_{0-12hr}$ $C_{max}$ and $T_{max}$ were over 0.9. Minimal detectable difference $({\Delta})$ at ${\alpha}=0.05$, $1-{\beta}=0.8$ were less than 20% (i.e., 12.84, 11.05 and 17.99% for $AUC_{0-12hr}$, $C_{max}$ and $T_{max}$, respectively). The 90% confidence intervals $({\delta})$ for these parameters were also within ${\pm}20%$ (i.e., $-0.53{\le}{\delta}{\le}17.76$, $3.23{\le}{\delta}{\le}18.97$ and $-12.81{\le}{\delta}{\le}12.81$ for $AUC_{0-12hr}$, $C_{max}$ and $T_{max}$, respectively). These results satisfied the criteria of KFDA guideline for bioequivalence, indicating the two formulations of cefixime were bioequivlent.

  • PDF

Evaluation of Validity of Edentulous Digital Model for Complete Denture Fabrication (총의치 제작을 위한 무치악 디지털 모형의 정확도 평가)

  • Kim, Won-Soo;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • 제15권4호
    • /
    • pp.393-398
    • /
    • 2015
  • One of the most critical causes in determining the clinical outcomes of dental prostheses is the validity of models. However, studies that evaluated validity of digital models are few. The objectives of this study were to evaluate validity of edentulous digital models for full denture fabrication. Twenty stone models (edentulous model) were manufactured and scanned by dental blue light emitting diode scanner. Twenty digital models were manufactured. Six linear distances (inter-canine distance, inter-molar distance, two dental arch lengths (right, left), two diagonal of dental arch lengths (right, left) were measured for validity evaluation. The measurements of distances of stone models were used by digital vernier caliper and digital models were used by computer program. The mean${\pm}$deviations values of six distances were calculated. The means were compared by the Mann Whitney U test (${\alpha}=0.05$). All statistical analysis were performed using IBM SPSS Statistics ver. 20.0. Although digital models were smaller than stone models in six distances, there were no significant differences (p>0.05) and non exceeded the clinical acceptable range. The edentulous digital models for full denture fabrication can be considered clinically acceptable.