• Title/Summary/Keyword: $H\infty$ control

Search Result 704, Processing Time 0.028 seconds

[ $H_{\infty}$ ] Pressure Control of Pneumatic Valve Driven by Piezoactuators (압전 작동기로 구동 되는 공압 밸브의 $H_{\infty}$ 압력제어)

  • Yoo, J.K.;Cho, M.S.;Choi, S.B.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.673-678
    • /
    • 2001
  • This paper proposes a new type of piezoactuator-driven valve system. The piezoceramic actuator bonded to both sides of a flexible beam surface makes a movement required to control the pressure at the flapper-nozzle of a pneumatic valve system. After establishing a dynamic model, an appropriate size of the valve system is designed and manufactured. Subsequently, a robust $H_{\infty}$ control algorithm is formulated in order to achieve accurate tracking control of the desired pressure. The controller is experimentally realized and control performance for the sinusoidal pressure trajectory is presented in time domain. The control bandwidth of the valve system, which directly represents the fastness, is also evaluated in the frequency domain.

  • PDF

Output Feedback Fuzzy H(sup)$\infty$ Control of Nonlinear Systems with Time-Varying Delayed State

  • Lee, Kap-Rai
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.2 no.4
    • /
    • pp.248-254
    • /
    • 2000
  • This paper presents and output feedback fuzzy H(sup)$\infty$ control problem for a class of nonlinear systems with time-varying delayed state. The Takagi-Sugeno fuzzy model is employed to represent a nonlinear systems with time-varying delayed state. Using a single quadratic Lyapunov function, the globally exponential stability and disturance attenuation of the closed-loop fuzzy control system are discussed. Sufficient conditions for the existence of fuzzy H(sup)$\infty$ controllers are given in terms of matrix inequalities. Constructive algorithm for design of fuzzy H(sup)$\infty$ controller is also developed. A simulation example is given to illustrate the performance of the proposed design method.

  • PDF

Design of Robust Load Frequency Controller using Mixed Sensitivity based $H_{\infty}$ norm (혼합강도 $H_{\infty}$ 제어기법을 이용한 강인한 부하주파수 제어기 설계)

  • 정형환;김상효;이정필;한길만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.3
    • /
    • pp.88-98
    • /
    • 2000
  • In this paper, a robust controller using $H_{\infty}$ control theory has been designed for the load frequency control of interconnected 2-area power system. The main advantage of the proposed $H_{\infty}$ controller is that uncertainties of power system can be included at the stage of controller design. Representation of uncertainties is modeled by multiplicative uncertainly. In the mixed sensitivity problems, disturbance attenuation and uncertainty of the system is treated simultaneously. The robust stability and the performance of model uncertainties are represented by frequency weighted transfer function. The design of load frequency controller for each area was based on state-space approach. The comparative computer simulation results for the proposed controller and the conventional techniques such as the optimal control and the PID one were analyzed at the additions of various disturbances. Their deviation magnitude of frequency and tie line power flow at each area were mainly evaluated. Also the testing results of robustness for the cases that the perturbations of the all parameters of power system were amounted to about 20% were introduced. It was approved that the resultant performances of the proposed $H_{\infty}$ controller with mixed sensitivity were more robust and stable than the one of conventional controllers.

  • PDF

$H_{\infty}$ Composite Control for Singularly Perturbed Nonlinear Systems via Successive Galerkin Approximation

  • Kim, Young-Joong;Kim, Beom-Soo;Shin, Eun-Chul;Yoo, Ji-Yoon;Lim, Myo-Taeg
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.407-412
    • /
    • 2004
  • This paper presents a new algorithm for the closed-loop $H_{\infty}$ composite control of singularly perturbed nonlinear systems with a exogenous disturbance, using the successive Galerkin approximation(SGA). The singularly perturbed nonlinear system is decomposed into two subsystems of a slow-time scale and a fast-time scale via singular perturbation theory, and two $H_{\infty}$ control laws are obtained to each subsystem by using the SGA method. The composite control law that consists of two $H_{\infty}$ control laws of each subsystem is designed. One of the purposes of this paper is to design the closed-loop $H_{\infty}$ composite control law for the singularly perturbed nonlinear systems via the SGA method. The other is to reduce the computational complexity when the SGA method is applied to the high order systems.

  • PDF

Robust Control System Design for an AMB by $H_{\infty}$ Controller ($H_{\infty}$ 제어기에 의한 능동 자기 베어링 시스템의 강인한 제어계 설계)

  • Chang, Y.;Yang, J.H.
    • Journal of Power System Engineering
    • /
    • v.7 no.3
    • /
    • pp.48-53
    • /
    • 2003
  • This paper deals with the control of a horizontally placed flexible rotor levitated by electromagnets in a multi-input/multi-output (MIMO) active magnetic bearing(AMB) system. AMB is a kind of novel high performance bearing which can suspend the rotor by magnetic force. Its contact-free manner between the rotor and stator results in it being able to operate under much higher speed than conventional rolling bearings with relatively low power losses, as well as being environmental-friendly technology for AMB system having no wear and no lubrication requirements. In this MIMO AMB system, the rotor is a complex mechanical system, it not only has rigid body characteristics such as translational and slope motion but also bends as a flexible body. Reduced order nominal model is computed by consideration of the first 3 mode shapes of rotor dynamics. Then, the $H_{\infty}$ control strategy is applied to get robust controller. Such robustness of the control system as the ability of disturbance rejection and modeling error is guaranteed by using $H_{\infty}$ control strategy. Simulation results show the validation of the designed control system and the modeling method to the rotor.

  • PDF

Robust Positioning Control of a Flexible beam using $H_2/H_{\infty}$ and $\mu$-theory ($H_2$/H$\infty$$\mu$이론을 이용한 유연 빔의 위치제어)

  • 최연욱
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.1
    • /
    • pp.101-107
    • /
    • 2001
  • The objective of this paper is to present a method for designing robust positioning control systems of a flexible arm using mixed $H_2/H_{\infty}$ and $\mu$ theory. We begin with a description of the flexible arm based on the model identification method and discuss the derivation of the model uncertainty. The validity of the obtained model is confirmed experimentally. Next, a robust controller is designed based on the mixed $H_2/H_{\infty}$ and $\mu$ theory by which we can improve robustness of the entire system. On this occasion, we also propose a general plant formation suitable to mixed $H_2/H_{\infty}$ control and $\mu$-theory. Finally, the effectiveness of the proposed design method is verified through experimentation.

  • PDF

Control of Active Suspension System by Using H$\infty$ Theory

  • Nguyen, Tan-Tien;Nguyen, Van-Giap;Kim, Sang-Bong
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • This paper presents a control of active suspension for quarter car model with two degree of freedom by using H$\infty$ method. Absolute velocity of car body is measured for feedback. The system parameter variations are treated with multiplicative uncertainty model. Simulation results show that the H$\infty$ control provides good trade-off between ride quality, suspension packaging and road holding constraints. The experiment with a front wheel suspension system was done to verify the simulation results.

  • PDF

Robust $H_{\infty}$ Control of Uncertain Descriptor Systems With Time-Varying Delays

  • Kim, Jong-Hae
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.3
    • /
    • pp.199-204
    • /
    • 2002
  • This paper is concerned with H$_{\infty}$ controller design methods for descriptor systems with and without time-varying delays in state and control input. The sufficient condition for the existence of an H$_{\infty}$ controller and the controller design method are presented by linear matrix inequality (LMI), singular value decomposition, Schur complements, and changes of variables. Since the obtained sufficient condition can be changed to an LMI form by proper manipulations, all solutions including controller gain can be obtained at the same time. Moreover, it is shown that robust H$_{\infty}$ controller design problem for parameter uncertain descriptor systems with time-varying delays in state and control input can be solvable using the proposed method.

Decentralized $H_{\infty}$ Control with Performance for Discrete LTI Interconnected Systems with Time Delay (시간지연을 갖는 이산 선형 시불변 연결 시스템의 분산 $H_{\infty}$ 제어)

  • Shim, Duk-Sun;Kim, Youngjae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.9
    • /
    • pp.752-757
    • /
    • 2000
  • This paper considers a decentralized control problem of dicrete LTI systems which have time delay between interconnections. This paper provides sufficient conditions for the decentralized controller to exist as a H$\infty$ disturbance attenuation ${\gamma}$ of a scaled system and shows that the controller can be designed by using the discrete standard $H_{\infty}$ control theory.

  • PDF

$H_\infty$Control Synthesis for Robust Control of a Turbo-Generator (터-빈 발전기의 견실성 제어를 위한$H_\infty$제어 시스템 설계)

  • Chung, Dae-Won;Kim, Kern-Joong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.622-628
    • /
    • 1999
  • This paper presented to design a robust turbo-generator control system using {{{{ { H}_{$\infty$ } }}}} control synthesis for improving small-signal stability. Application study of{{{{ { H}_{$\infty$ } }}}} control synthesis is more appropriate in this system since a turbo-generator system is usually operated under circumstance of unmeasurable modelling uncertainty and external disturbance. The{{{{ { H}_{$\infty$ } }}}} control theory was briefly reviewed for good understanding and the reasonable approach. The design results are simulated for a case study and to check the system performance in comparison with currently operating Lead/Lag filtered PSS performance.

  • PDF