• Title/Summary/Keyword: $Cl^-$

Search Result 13,613, Processing Time 0.043 seconds

Feasibility of MatriXX for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료의 품질관리를 위한 이온전리함 매트릭스의 유용성 고찰)

  • Kang, Min-Young;Kim, Yoen-Lae;Park, Byung-Moon;Bae, Yong-Ki;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.91-97
    • /
    • 2007
  • Purpose: To evaluate the feasibility of a commercial ion chamber array for intensity modulated radiation therapy (IMRT) quality assurance (QA) was performed IMRT patient-specific QA Materials and Methods: A use of IMRT patient-specific QA was examined for nasopharyngeal patient by using 6MV photon beams. The MatriXX (Wellhofer Dosimetrie, Germany) was used for IMRT QA. The case of nasopharyngeal cancer was performed inverse treatment planning. A hybrid dose distribution made on the CT data of MatriXX and solid phantom all of the same gantry angle (0$^\circ$). The measurement was acquired with geometrical condition that equal to hybrid treatment planning. The $\gamma$-index (dose difference 3%, DTA 3 mm) histogram was used for quantitative analysis of dose discrepancies. An absolute dose was compared at the high dose low gradient region. Results: The dose distribution was shown a good agreement by gamma evaluation. A proportion of acceptance criteria was 95.8%, 97.52%, 96.28%, 98.20%, 97.78%, 96.64% and 92.70% for gantry angles were 0$^\circ$, 55$^\circ$, 110$^\circ$, 140$^\circ$, 220$^\circ$, 250$^\circ$ and 305$^\circ$, respectively. The absolute dose in high dose low gradient region was shown reasonable agreement with the RTP calculation within $\pm$3%. Conclusion: The MatriXX offers the dosimetric characteristics required for performing both relative and absolute measurements. If MatriXX use in the clinic, it could be simplified and reduced the IMRT patient-specific QA workload. Therefore, the MatriXX is evaluated as a reliable and convenient dosimeter for IMRT patient-specific QA.

  • PDF

Toxin Produced by Pathogenic Vibrios Isolated from Sea Food (수산물에서 분리된 병원성 비브리오균의 용혈성독소)

  • CHANG Dong-Suck;SHINODA Sumio
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.2
    • /
    • pp.107-113
    • /
    • 1994
  • Among the currently recognized pathogenic vibrios, V. vulnificus and V. cholerae non O1 are the most serious bacteria from the point of view of sea food hygiene in Korea. In this paper, the authors compared the hemolytic activities of the crude hemolysin produced by V. vulnificus and V. cholerae non O1 isolated from shellfish collected in Chungmoo, Korea. The authors also attempted to improve the purification method of V. vulnificus hemolysin(VVH) and tried to make antiserum with the purified hemolysin. VVH was produced in abundance in heart infusion broth containing $2\%$ NaCl in a shaking cultivation process(140rpm) at $37^{\circ}C$ for 15 hours. While hemolysin production patterns of V. cholerae non O1 were quite different by the strain during the culture times compared with the V. vulnificus. Hemolytic activity of the VVH on sheep erythrocytes was stronger than those of rabbit, but hemolytic activities of the hemolysin produced by V. cholerae non O1 on rabbit erythrocytes were as much as twice as strong as on those of sheep and horse. VVH was purified by two steps of hydrophobic column chromatography on Phenyl-Sepharose HP with Fast Protein Liquid Chromatography(FPLC). Purification fold and yield of VVH was much improved by changing the elution buffer's pH from 6.0 to 9.8 and adding $1\%$ CHAPS(a zwitter ionic detergent) and $50\%$ ethylene glycol to the 10mM glycine buffer during the repeated hydrophobic column chromatography. Homogeneity of the purified hemolysin was shown by polyacrylamide gel electrophoresis. According to the five times repeated purification results, the specific activity was increased 27500 times and the yield was improved by $23.4\%$ on average. About $250{\mu}g$ of purified hemolysin was harvested from the 2400ml of culture supernatant of V. vulnificus. Molecular weight of VVH was estimated to be 50KDa by the SDS-PAGE and the neutralization scores of the obtained antiserum acting against VVH were $2000{\sim}8500$.

  • PDF

Feasibility Study on Double Path Capacitive Deionization Process for Advanced Wastewater Treatment (이단유로 축전식 탈염공정의 하수고도처리 적용가능성 평가)

  • Cha, Jaehwan;Shin, Kyung-Sook;Lee, Jung-Chul;Park, Seung-Kook;Park, Nam-Su;Song, Eui-Yeol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.295-302
    • /
    • 2014
  • This study demonstrates a double-path CDI as an alternative of advanced wastewater treatment process. While the CDI typically consists of many pairs of electrodes connected in parallel, the new double-path CDI is designed to have series flow path by dividing the module into two stages. The CFD model showed that the double-path had uniform flow distribution with higher velocity and less dead zone compared with the single-path. However, the double-path was predicted to have higher pressure drop(0.7 bar) compared the single-path (0.4 bar). From the unit cell test, the highest TDS removal efficiencies of single- and double-path were up to 88% and 91%, respectively. The rate of increase in pressure drop with an increase of flow rate was higher in double-path than single-path. At 70 mL/min of flow rate, the pressure drop of double-path was 1.67 bar, which was two times higher than single-path. When the electrode spacing was increased from 100 to $200{\mu}m$, the pressure drop of double-path decreased from 1.67 to 0.87 bar, while there was little difference in TDS removal. When proto type double-path CDI was operated using sewage water, TDS, $NH_4{^+}$-N, $NO_3{^-}$-N and $PO_4{^{3-}}$-P removal efficiencies were up to 78%, 50%, 93% and 50%, respectively.

Relevance of Vitamin D and Dyslipidemia Among Korean Adults - Using Data from the Sixth Korea National Health and Nutrition Examination Survey, 2013~2014 (한국 성인의 비타민 D 수준과 이상지질혈증과의 관련성 - 제 6기(2013년, 2014년) 국민건강영양조사 자료를 이용하여)

  • kim, han-soo;Han, Yeo-Jung;Kim, Byung-Cheol;Ryu, So-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.647-656
    • /
    • 2017
  • Purpose: This study investigated the relationship between vitamin D level and dyslipidemia in Korean adults aged 19 years and older. The data for analysis were obtained from the sixth Korea National Health Nutrition Examination Survey 2013 and 2014. Result: This study showed that 74.4% of the specified adult population had vitamin D deficiency. Moreover, the prevalence of dyslipidemia was found to be 39.6% in the same population. Dyslipidemia differed significantly according to gender (p<0.001), age (p<0.001), smoking status (p<0.001), subjective health status (p<0.001), BMI (p<0.001), blood pressure (p<0.001), FBS (p<0.001), physical activity (p<0.001), and vitamin D level (p<0.001). When vitamin D deficiency was less than 20.0 ng/mL, there was a significant risk of dyslipidemia with an odds ratio of 1.29 (95% Cl, 1.11-1.51). The relationship between vitamin D level and a diagnosis index of dyslipidemia with controlled status of physical activity was statistically significant; in Korean adults, the odds ratio for total cholesterol was 1.41 (95% CI, 1.04-1.81) and for triglyceride was 1.36 (95% CI, 1.11-1.66). Conclusion: Our results showed the relationship between vitamin D level and dyslipidemia was significant in Korean adults, and total cholesterol and triglycerides, which are indicators of dyslipidemia, was significant. Future studies, such as a more systematic cohort study investigating the relationship between vitamin D level and dyslipidemia may be helpful in confirming the causal relationship between vitamin D and dyslipidemia.

Competition of Adlay and Dominant Weeds, and Weed Control (율무와 우점잡초의 경합 및 방제효과)

  • Yoon, Seong-Tak;Yi, Eun-Sub;Kim, Ki-Jung;Yoon, Seung-Gil
    • Korean Journal of Medicinal Crop Science
    • /
    • v.7 no.2
    • /
    • pp.121-128
    • /
    • 1999
  • This experiment was carried out to establish effective weed control system in the cultivation of Coix lachryma-jobi L. The effect of annual weeds artificially transplanted on the growth of Coix lachryma-jobi L. were that the higher the density of weeds, the lower the yield considerably by reducing number of grains and tillers per plant. Among four weeds of Echinochloa crusgalli galli P. BEAUV., Digitaria sanguinalis $S_{COPOL}$., Chenopodium album L., and Portulaca oleracea L., weed of Portulaca oleracea L. reduced adlay yield most by 182.6kg/10a and it was judged to be the most injurious weed to adlay production. Among four weed control systems, which are one herbicide treatment, one herbicide treatment + one cultivating work with cultivator, two times cultivating work with cultivator and two times hand-weeding, the control system of 'one herbicide treatment + one cultivating work with cultivator' showed the lowest amount of weed growth by 7.34 weeds per $m^2$ in comparison with control plot of 35.00 weeds per $m^2$. Among four weed control systems, the system of 'two times hand-weeding' had much more amount of light penetration in adlay canopy with 791.9 mol than any other systems.

  • PDF

Isolation and characterization of sigH from Corynebacterium glutamicum (Corynebacterium glutamicum의 sigH 유전자의 분리 및 기능분석)

  • Kim Tae-Hyun;Kim Hyung-Joon;Park Joon-Sung;Kim Younhee;Lee Heung-Shick
    • Korean Journal of Microbiology
    • /
    • v.41 no.2
    • /
    • pp.99-104
    • /
    • 2005
  • Corynebacterial clones which exert regulatory effects on the expression of the glyoxylate bypass genes were isolated using a reporter plasmid carrying the enteric lacZ fused to the aceB promoter of Corynebacterium glutamicum. Some clones carried common fragments as turned out by DNA mapping technique. Subcloning analysis followed by the measurement of $\beta-galactosidase$ activity in Escherichia coli identified the region responsible for the aceB-repressing activity. Sequence analysis of the DNA fragment identified two independent ORFs of ORF1 and ORF2. Among them, ORF2 was turned out to be responsible for the aceB-repressing activity. ORF1 encoded a 23,216 Da protein composed of 206 amino acids. Sequence similarity search indicated that the ORF may encode a ECF-type $\sigma$ factor and designated sigH. To identify the function of sigH, C. glutamicum sigH mutant was constructed by gene disruption technique and the sigH mutant showed growth retardation as compared to the wild type strain. In addition, the mutant strain showed sensitivity to oxidative-stress generating agent plumbagin. This result imply that sigH is probably involved in the stress response occurring during normal cell growth.

Development of Phantom and Comparison Analysis for Performance Characteristics of MOSFET Dosimeter (MOSFET 선량계 특성분석을 위한 팬톰 개발 및 특성 비교)

  • Chung, Jin-Beom;Lee, Jeong-Woo;Kim, Yon-Lae;Lee, Doo-Hyun;Choi, Kyoung-Sik;Kim, Jae-Sung;Kim, In-Ah;Hong, Se-Mie;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.48-54
    • /
    • 2007
  • This study is to develope a phantom for MOSFET (Metal Oxide Semiconductors Field Effect Transistors) dosimetry and compare the dosimetric properties of standard MOSFET and microMOSFET with the phantom. In this study, the developed phantom have two shape: one is the shape of semi-sphere with 10cm diameters and the other one is the flat slab of $30{\times}30cm$with 1 cm thickness. The slab phantom was used for calibration and characterization measurements of reproducibility, linearity and dose rate dependency. The semi-sphere phantom was used for angular and directional dependence on the types of MOSFETs. The measurements were conducted under $10{\times}10cm^2$ fields at 100cm SSD with 6MV photon of Clinac (21EX, Varian, USA). For calibration and reproducibility, five standard MOSFETS and microMOSFETs were repeatedly Irradiated by 200cGy five times. The average calibration factor was a range of $1.09{\pm}0.01{\sim}1.12{\pm}0.02mV/cGy$ for standard MOSFETS and $2.81{\pm}0.03{\sim}2.85{\pm}0.04 mV/cGy$ for microMOSFETs. The response of reproducibility in the two types of MOSFETS was found to be maximum 2% variation. Dose linearity was evaluated In the range of 5 to 600 cGy and showed good linear response with $R^2$ value of 0.997 and 0.999. The dose rate dependence of standard MOSFET and microMOSFET was within 1% for 200 cGy from 100 to 500MU/min. For linearity, reproducibility and calibration factor, two types of MOSFETS showed similar results. On the other hand, the standard MOSFET and microMOSFET were found to be remarkable difference in angular and directional dependence. The measured angular dependence of standard MOSFET and microMOSFET was also found to be the variation of 13%, 10% and standard deviation of ${\pm}4.4%,\;{\pm}2.1%$. The directional dependence was found to be the variation of 5%, 2% and standard deviation of ${\pm}2.1%,\;{\pm}1.5%$. Therefore, dose verification of radiation therapy used multidirectional X-ray beam treatments allows for better the use of microMOSFET which has a reduced angular and directional dependence than that of standard MOSFET.

  • PDF

Evaluation of the Giggenbach Bottle Method with Artificial Fumarolic Gases (인공 분기공 가스를 이용한 Giggenbach bottle 법의 평가)

  • Lee, Sangchul;Kang, Jungchun;Yun, Sung Hyo;Jeong, Hoon Young
    • Journal of the Korean earth science society
    • /
    • v.34 no.7
    • /
    • pp.681-692
    • /
    • 2013
  • We aimed to evaluate the effectiveness of the Giggenbach bottle method and develop the related pretreatment and analytical methods using artificial fumarolic gases. The artificial fumarolic gases were generated by mixing $CO_2$, CO, $H_2S$, $SO_2$, $H_2$, and $CH_4$ gas streams with a $N_2$ stream sparged through an acidic medium containing HCl and HF, with their compositions varied by adjusting the gas flow rates. The resultant fumarolic gases were collected into an evacuated bottle partially filled with a NaOH absorption solution. While non-condensible gases such as CO, $H_2S$, and $CH_4$ accumulated in the headspace of the bottle, acidic components including $CO_2$, $SO_2$, HCl, and HF that were dissolved into the alkaline solution. Like other acidic components, $H_2S$ also dissolved into the solution, but it reacted with dissolved $Cd^{2+}$ to precipitate as CdS when $Cd(CH_3COO)_2$ was added. The non-condensible gases were analyzed on a gas chromatography. Then, CdS precipitates were separated from the alkaline solution by filtration, and they were pretreated with $H_2O_2$ to oxidize CdS-bound sulfide into sulfate. In addition, a portion of the solution was also pretreated with $H_2O_2$ to oxidize sulfite to sulfate. Following the pretreatment, the resultant samples were analyzed for $SO_4^{2-}$, $Cl^-$ and $F^-$ on an ion chromatography. In the meanwhile, dissolved $CO_2$ was analyzed on a total organic carbon-inorganic carbon analyzer without such pretreatment. According to our experimental results, the measured concentrations of the fumarolic gases were shown to be proportional to the gas flow rates, indicating that the Giggenbach bottle method is adequate for monitoring volcanic gas. The pretreatment and analytical methods employed in this study may also enhance the accuracy and reproducibility of the Giggenbach bottle method.

A STUDY ON SKELETAL RELAPSE PATTERNS FOLLOWING ORTHOGNATHIC SURGERY OF CLASS III PATIENTS : COMPARISON BETWEEN SSRO AND IVRO (제 III급 부정교합자의 악교정 수술후 골격적 재발 양상에 관한 연구 : 구내 시상 분할 골절단술과 구내 상행지 수직 골절단술의 비교)

  • Lee, Jang-Yeol;Yu, Hyung-Seog;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.28 no.3 s.68
    • /
    • pp.461-477
    • /
    • 1998
  • To evaluate the relapse pattern and long-term stabilities depanding on surgical methods following orthognathic surgery of Cl III patients, the author selected 24 subjects(10 male, 14 female) operated by SSRO and 26 subjects(10 male,16 female) operated by IVRO. Each subject took four lateral cephalograms : just before surgery(T1), within 48hrs after surgery(T2), 4-8 wks after surgery(T3), 6 month or more after surgery(T4), and the landmarks were digitized. The differences of relapse patterns in each interval between two groups were compared and the significance of correlation among the variables of each group was tested. The obtained results are as follows ; 1. Horizontal early relapse was forward movement of mandible in SSRO group, as compared to the backward movement in IVRO group, and there was a statistical significance between the two groups. 2. Vertical early and late relapses were decreases in anterior facial height in both groups and there was no statistical significance between the two groups. 3. There was a statistical significance in negative correlation between mandibular horizontal late relapse and surgical change of articular angle in SSRO group. 4. There was a statistical significance in negative correlation between amount of mandibular set-back and mandibular horizontal early relapse in both groups.

  • PDF

Formulation of a reference coordinate system of three-dimensional head & neck images: Part II. Reproducibility of the horizontal reference plane and midsagittal plane (3차원 두부영상의 기준좌표계 설정을 위한 연구: II부 수평기준면과 정중시상면의 재현성)

  • Park, Jae-Woo;Kim, Nam-Kug;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.475-484
    • /
    • 2005
  • This study was performed to investigate the reproducibility of the horizontal and midsagittal planes, and to suggest a stable coordinate system for three-dimensional (3D) cephalometric analysis. Eighteen CT scans were taken and the coordinate system was established using 7 reference points marked by a volume model, with no more than 4 points on the same plane. The 3D landmarks were selected on V works (Cybermed Inc., Seoul, Korea), then exported to V surgery (Cybermed Inc., Seoul, Korea) to calculate the coordinate values. All the landmarks were taken twice with a lapse of 2 weeks. The horizontal and midsagittal planes were constructed and its reproducibility was evaluated. There was no significant difference in the reproducibility of the horizontal reference planes, But, FH planes were more reproducible than other horizontal planes. FH planes showed no difference between the planes constructed with 3 out of 4 points. The angle of intersection made by 2 FH planes, composed of both Po and one Or showed less than $1^{\circ}$ difference. This was identical when 2 FH planes were composed of both Or and one Po. But, the latter cases showed a significantly smaller error. The reproducibility of the midsagittal plane was reliable with an error range of 0.61 to $1.93^{\circ}$ except for 5 establishments (FMS-Nc, Na-Rh, Na-ANS, Rh-ANS, and FR-PNS). The 3D coordinate system may be constructed with 3 planes; the horizontal plane constructed by both Po and right Or; the midsagittal plane perpendicular to the horizontal plane, including the midpoint of the Foramen Spinosum and Nc; and the coronal plane perpendicular to the horizontal and midsagittal planes, including point clinoidale, or sella, or PNS.