• Title/Summary/Keyword: $CO_2$ leakage

Search Result 381, Processing Time 0.029 seconds

Manufacture and Characteristics of the Planar Transformer using low power loss magnetic materials (저손실 자심재료를 이용한 평면변압기 제조 및 동작특성)

  • Lee, Hae-Yon;Heo, Jeong-Seob;Kim, Hyun-Sik;Park, Hye-Young;Ustinov, Evgeniy
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.19-22
    • /
    • 2004
  • The resonant planar transformer, which had power capacity of 300 W, input voltage of 220 V, output voltage of 15 V, and switching frequency of 500 kHz, was designed and manufactured by using the planar core with large effective area and the flat copper lead frames for miniaturization and high efficiency of the switching mode power supply (SMPS). As well as, a resonant converter equipped with the above mentioned planar transformer was manufactured and electromagnetic characteristics were investigated. The numerical value of turns for 1st and 2nd winding were 12 and 2 respectively. The self inductance of 1st winding was 33.2 ${\mu}H$, very low leakage inductance of 1.27 ${\mu}H$, and the coupling factor of 0.98 were obtained at switching frequency of 300 kHz. The high efficiency of 88.21 % for the SMPS equipped with planar transformer was obtained at power capacity of 300 W.

  • PDF

Surface and Electrical Properties of Sr Based Thin Film with Annealing Temperature (열처리 온도에 따른 Sr계 박막의 표면 및 전기적인 특성)

  • Choi, Woon-Sik;Jo, Choon-Nam;Kim, Jin-Sa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.2
    • /
    • pp.132-135
    • /
    • 2014
  • The Sr based ceramic thin films were deposited on Si substrate by RF magnetron sputtering method. And Sr based thin films were annealed at $500{\sim}700^{\circ}C$ using RTA. The surface roughness showed about 2.4 nm in annealed thin film at $600^{\circ}C$. The capacitance density of Sr based thin films were increased with the increase of annealing temperature. The maximum capacitance density of $0.6{\mu}F/cm^2$ was obtained by annealing temperature at $700^{\circ}C$. The voltage dependence of dielectric loss showed about 0.02 in voltage ranges of -10~+10 V. The leakage current density of annealing temperature of $600^{\circ}C$ was the $4.0{\times}10^{-6}\;A/cm^2$ at applied voltage of -5~+5 V.

Genotoxicity (DNA damage) on Blood Cells of Parrot Fish (Oplegnathus fasciatus) Exposed to Acidified Seawater Making of CO2 (이산화탄소로 산성화된 해수에 노출된 돌돔(Oplegnathus fasciatus) 혈구세포에 대한 유전독성(DNA 손상))

  • Choi, Tae Seob;Lee, Ji-Hye;Sung, Chan-Gyoung;Lee, Jung-Suk;Park, Young-Gyu;Kang, Seong-Gil
    • Journal of Environmental Science International
    • /
    • v.23 no.3
    • /
    • pp.483-492
    • /
    • 2014
  • DNA damage such as genotoxicity was identified with comet assay, which blood cell of a marine parrot fish (Oplegnathus fasciatus) was exposed to an acidified seawater, lowered pH gradient making of $CO_2$ gas. The gradient of pH were 8.22, 8.03, 7.81, 7.55 with control as HBSS solution with pH 7.4. DNA tail moment of fish blood cell was $0.548{\pm}0.071$ exposed seawater of pH 8.22 condition, on the other hand, DNA tail moment $1.601{\pm}0.197$ exposed acidified seawater of pH 7.55 lowest condition. The approximate difference with level of DNA damage was 2.9 times between highest and lowest of pH. DNA damage with decreasing pH was significantly increased with DNA tail moment on blood cell of marine fish (ANOVA, p < 0.001). Ocean acidification, especially inducing the leakage of sequestered $CO_2$ in geological structure is a consequence from the burning of fossil fuels, and long term effects on marine habitats and organisms are not fully investigated. The physiological effects on adult fish species are even less known. This result shown that the potential of dissolved $CO_2$ in seawater was revealed to induce the toxic effect on genotoxicity such as DNA breakage.

Variation of the Physical-microstructural Properties of Sandstone and Shale Caused by CO2 Reaction in High Pressure Condition (고압 이산화탄소 반응에 의한 사암과 셰일의 물리적-미세구조적 변화)

  • Park, Jihwan;Son, Jin;Park, Hyeong-Dong
    • Tunnel and Underground Space
    • /
    • v.26 no.4
    • /
    • pp.293-303
    • /
    • 2016
  • Underground $CO_2$ storage technology is one of the most effective methods to reduce atmospheric $CO_2$. In this study, $CO_2$ storage condition was simulated in the laboratory. Sandstone and shale specimens were saturated in 1M NaCl and were reacted at $45^{\circ}C$, 10 atm for 4 weeks. The physical and microstructural properties of rock specimens were measured. Variations on physical properties of shale specimens were bigger than those of sandstone specimens, such as volume, density, elastic wave velocity, Poisson's ratio and Young's modulus. Microstructure were analyzed using X-ray computed tomography. Total number of pores were decreased, and average volume, average area and average equivalent diameter of each pore were changed after $CO_2$ reaction. Swelling and leakage of clay mineral caused by $CO_2$-mineral reaction were the reason of changes. The results of this study can be applied to predict the physical and microstructural changes in underground $CO_2$ storage condition.

Method for Measuring pH and Alkalinity of High-Pressure Fluid Samples : Evaluation through Artificial Samples (고압 유체 시료의 pH 및 알칼리도 측정 방법 : 가상 시료를 활용한 실용성 평가)

  • Minseok Song;Soohyeon, Moon;Gitak Chae;Jun-Hwan Bang
    • Journal of Soil and Groundwater Environment
    • /
    • v.29 no.1
    • /
    • pp.1-9
    • /
    • 2024
  • As part of monitoring technology aimed at verifying the stability of CO2 geologic storage and mitigating concerns about leakage, a method for measuring the pH and alkalinity of high-pressure fluid samples was established to obtain practical technology. pH measurement for high-pressure samples utilized a high-pressure pH electrode, and alkalinity was measured using the Gran titration method for samples collected with a piston cylinder sampler (PCS). Experimental samples, referencing CO2-rich water and CO2 geologic storage studies, were prepared in the laboratory. The PCS controls the piston, preventing CO2 degassing and maintaining fluid pressure, allowing mixing with KOH to fix dissolved CO2. Results showed a 6.1% average error in high-pressure pH measurement. PCS use for sample collection maintained pressure, preventing CO2 degassing. However, PCS-collected sample alkalinity measurements had larger errors than non-PCS measurements, limiting PCS practicality in monitoring field settings. Nevertheless, PCS could find utility in preprocessing for carbon isotope analysis and other applications. This research not only contributes to the field of CCS monitoring but also suggests potential applications in studies related to natural analogs of CCS, CO2-rock interaction experiments, core flooding experiments, and beyond.

High performance 3D pin-by-pin neutron diffusion calculation based on 2D/1D decoupling method for accurate pin power estimation

  • Yoon, Jooil;Lee, Hyun Chul;Joo, Han Gyu;Kim, Hyeong Seog
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3543-3562
    • /
    • 2021
  • The methods and performance of a 3D pin-by-pin neutronics code based on the 2D/1D decoupling method are presented. The code was newly developed as an effort to achieve enhanced accuracy and high calculation performance that are sufficient for the use in practical nuclear design analyses. From the 3D diffusion-based finite difference method (FDM) formulation, decoupled planar formulations are established by treating pre-determined axial leakage as a source term. The decoupled axial problems are formulated with the radial leakage source term. To accelerate the pin-by-pin calculation, the two-level coarse mesh finite difference (CMFD) formulation, which consists of the multigroup node-wise CMFD and the two-group assembly-wise CMFD is implemented. To enhance the accuracy, both the discontinuity factor method and the super-homogenization (SPH) factor method are examined for pin-wise cross-section homogenization. The parallelization is achieved with the OpenMP package. The accuracy and performance of the pin-by-pin calculations are assessed with the VERA and APR1400 benchmark problems. It is demonstrated that pin-by-pin 2D/1D alternating calculations within the two-level 3D CMFD framework yield accurate solutions in about 30 s for the typical commercial core problems, on a parallel platform employing 32 threads.

DA-7911, $^{188}Rhenium-tin$ Colloid, as a New Therapeutic Agent of Rheumatoid Arthritis

  • Shin, Chang-Yell;Son, Miwon;Ko, Jun-Il;Jung, Mi-Young;Lee, In-Ki;Kim, Soon-Hoe;Kim, Won-Bae;Jeong, Jae-Min;Song, Yeong-Wook
    • Archives of Pharmacal Research
    • /
    • v.26 no.2
    • /
    • pp.168-172
    • /
    • 2003
  • Radiation synovectomy is one of the most useful methods for treating patients with refractory synovitis because of its convenience, long-term effects, repeatability and the avoidance of surgery. In this study, we investigated the toxicity, stability and biodistribution of a rhenium-188 ($^{188}$Re)-tin colloid to evaluate its suitability as a synovectomy agent. Twenty four hours after injecting the $^{188}$Re-tin colloids (74 KBq/0.1 mL) into the tail vein of ICR mice, most of the $^{188}$Retin colloidal particles was found in the lungs. In addition, there were no particle size changes at either room temperature or at $37^{\circ}C$ after injecting the $^{188}$Re-tin colloids in human plasma and synovial fluid. In vitro stability tests showed that the $^{188}$Re-tin colloid remained in a colloidal form without a critical size variation over a 2-day period. We investigated the leakage of $^{188}$Retin colloids from the intraarticular injection site with gamma counting in New Zealand white rabbits. The $^{188}$Re-tin colloids (55.5 MBq/0.15 mL) were injected at the cavum articular and the mean retention percentage of the $^{188}$Re-tin colloid was 98.7% for 1 day at the injection site, which suggests that there was neither change in the particle size nor leakage at the injection sites. In the biodistribution study with the SD rats, the liver showed the highest radioactivity (0.0427% ID/organ) except for the injected knees (99.49%). In the SD rats, mild toxicities including the skin or a synovium inflammation were observed as a result of a radioactivity of 15 mCi/kg at the intraarticular injection site. However, there was no systemic toxicity. In the Ovalbumin (OVA)-induced arthritic rabbits, the $^{188}$Re-tin colloid improved the macroscopic, the histological score and reduced the knee joint diameter when compared to the arthritic control. In conclusion, a $^{188}$Re-tin-colloid is considered as a strong candidate for radiation synovectomy with a superior efficacy and safety.

Effect of Sintering Temperature on Electrical Properties of $Pr_{6}O_{11}$-Based ZnO Varistors ($Pr_{6}O_{11}$계 ZnO 바리스터의 전기적 성질에 소결온도의 영향)

  • 남춘우;류정선
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.7
    • /
    • pp.572-577
    • /
    • 2001
  • The electrical properties of Pr$_{6}$ O$_{11}$ -based ZnO varistors consisting of ZnO-Pr$_{6}$ O$_{11}$ -CoO-Cr$_2$O$_3$-Er$_2$O$_3$ ceramics were investigated with sintering temperature in the range of 1325~f1345$^{\circ}C$. As sintering temperature is raised., the nonlinear exponent was increased up to 1335$^{\circ}C$, reaching a maximum 70.53, whereas raising sintering temperature further caused it to decrease, reaching a minimum 50.18 and the leakage current was in the range of 1.92~4.12 $\mu$A. The best electrical properties was obtained from the varistors sintered at 1335$^{\circ}C$, exhibiting a maximum (70.53) in the nonlinear exponent and a minimum (1.92 $\mu$A) in the leakage current, and a minimum (0.035) in the dissipation factor. On the other hand, the donor concentration was in the range of (0.90~1.14)x10$^{18}$ cm$^{-3}$ , the density of interface states was in the range of (2.69~3.60)x10$^{12}$ cm$^{-2}$ , and the barrier height was in the range of 0.77~1.21 eV with sintering temperature. With raising sintering temperature, the variation of C-V characteristic parameters exhibited a mountain type, reaching maximum at 134$0^{\circ}C$. Conclusively, it was found that the V-I, C-V, and dielectric characteristics of Pr$_{6}$ O$_{11}$ -based ZnO varistors are affected greatly by sintering temperature.

  • PDF

Formation of the Diamond Thin Film as the SOD Sturcture (SOD 구조 형성에 따른 다이아몬드 박막 형성)

  • Ko, Jeong-Dae;Lee, You-Seong;Kang, Min-Sung;Lee, Kwang-Man;Lee, Kae-Myoung;Kim, Duk-Soo;Choi, Chi-Kyu
    • Korean Journal of Materials Research
    • /
    • v.8 no.11
    • /
    • pp.1067-1073
    • /
    • 1998
  • High quality diamond films of the silicon on diamond (SOD) structure are deposited using CO and $H_2$ gas mixture in microwave plasma chemical vapor deposition (CVD), a SOD structure is fabricated using low pressure CVD polysilicon on diamond/ Si(100) substrate. The crystalline structure of the diamond films which composed of { 111} and {100} planes. were changed from octahedral one to cubo-octahedron one as the CO/$H_2$ ratios are increased. The high quality diamond films without amorphous carbon and non-diamond elements were deposited at the CO/$H_2$ flow rate of 0.18. and the main phase of the diamond films shows (111) plane. The diamond/Si(lOO) structure shows that the interface is flat without voids. The measured dielectric constant. leakage current and breakdown field were $5.31\times10^{-9}A/cm^2$ and $9\times{10^7}{\Omega}cm$ respectively.

  • PDF

Measurement of R-134a Leakage from Vehicle Equipped Mobile Air Conditioning(MAC) System (실차를 이용한 자동차 에어컨 냉매 누출량 평가)

  • Kim, Ji Young;Seo, Chungyoul;Lee, Sangeun;Kim, Jeongsoo
    • Journal of Climate Change Research
    • /
    • v.3 no.2
    • /
    • pp.153-159
    • /
    • 2012
  • CFC-12 used in mobile air conditioning(MAC) system has been replaced by R-134a, a type of HFC refrigerant, from 1991 to 1994. R-134a has since been widely used as a refrigerant of a mobile air conditioner. However, it is one of the six main green house gases listed in Kyoto Protocol, which makes it imperative to regulate its emission and develop alternative refrigerants. In this study, the concentration of leaked R-134a was measured using VT(Variable Temperature) shed and Running loss test shed to analyze the level of air conditioner refrigerant leaked in a vehicle. According to the analysis of the concentration of R-134a leaked from a vehicle parked, annual leakage amount of R-134a was in the range of 6.46~13.28 g/yr. The figure was similar with the leakage from the mobile air conditioning system currently used. In a study using the same vehicle model, a vehicle equipped with dual evaporation system had a higher leakage rate of refrigerant than a vehicle with a single evaporation system. It appears that the added fittings and joints of the dual evaporator system led to higher leakage rate. Besides, the analysis of the change in R-134a concentration under various car speed found that more refrigerant leaked under high speed(100km/hr) and but the volume of the wind did not affect to the variation of refrigerant leakage.