• 제목/요약/키워드: $0.18{\mu}m$ Technology

검색결과 874건 처리시간 0.035초

A Study on the Eutectic Pb/Sn Solder Filip Chip Bump and Its Under Bump metallurgy(UBM)

  • Paik, Kyung-Wook
    • 마이크로전자및패키징학회지
    • /
    • 제5권1호
    • /
    • pp.7-18
    • /
    • 1998
  • In the flip chip interconnection on organic substrates using eutectic Pb/Sn solder bumps highly reliable Under Bump Metallurgy (UBM) is required to maintain adhesion and solder wettability. Various UBM systems such as 1$\mu$m Al/0.2$\mu$m Pd/1$\mu$m Cu, laid under eutectic Pb/Sn solder were investigated with regard to their interfacial reactions and adhesion proper-ties. The effects of numbers of solder reflow and aging time on the growth of intermetallic compounds (IMCs) and on the solder ball shear strength were investigated. Good ball shear strength was obtained with 1$\mu$m Al/0.2$\mu$m Ti/5$\mu$m Cu and 1$\mu$m Al/0.2$\mu$m ni/1$\mu$m Cu even after 4 solder reflows or 7 day aging at 15$0^{\circ}C$. In contrast 1$\mu$m Al/0.2$\mu$m Ti/1$\mu$m Cu and 1$\mu$mAl/0.2$\mu$m Pd/1$\mu$m 쳐 show poor ball shear strength. The decrease of the shear strength was mainly due to the direct contact between solder and nonwettable metal such as Ti and Al resulting in a delamination. In this case thin 1$\mu$m Cu and 0.2$\mu$m Pd diffusion barrier layer were completely consumed by Cu-Sn and pd-Sn reaction.

수원415호 유색미의 이화학적 특성 (Physicochemical Properties of Pigmented Rice (Suwon-415))

  • 이유석;조지미;이종욱
    • 한국식품과학회지
    • /
    • 제34권5호
    • /
    • pp.842-845
    • /
    • 2002
  • 현미 쌀가루의 평균입경과 중심입경은 각각 $33.41\;{\mu}m$$11.46\;{\mu}m$, 유색미 쌀가루는 각각 $38.53{\mu}\;m$$15.18\;{\mu}m$로 유색미의 입경이 현미보다 더 컸다. 유색미와 현미의 물결합능력은 각각 133.19%, 112.08%로 유색미의 물결합능력이 더 높았으며 X-선 회절도에 의한 결정형은 전형적인 A형을 보였으며 상대결정도는 유색미 쌀가루와 현미 쌀가루는 각각 0.35, 0.36으로 큰 차이를 보이지 않았다. 유색미와 현미를 $20{\sim}25^{\circ}C$의 온도에서 60분 동안 침지하면서 조사한 수분흡수속도는 수침온도와 시간이 증가할수록 수분흡수량이 더 크게 나타났으며, $50^{\circ}C$에서 유색미와 현미의 수분흡수속도상수는 각각 $0.0388\;min^{-1/2}$, $0.0273\;min^{-1/2}$으로 유색미가 더 높았다.

화장품 중 수용성 고분자인 Xanthan gum 분석연구 (Sturdy of analysis of Xanthan gum as watersoluble-polymer in cosmetics)

  • 이용화;양재찬
    • 한국응용과학기술학회지
    • /
    • 제30권4호
    • /
    • pp.664-671
    • /
    • 2013
  • 역상 HPLC 에 의한 화장품에 사용하는 수용성 고분자인 Xanthan gum의 간편하고 정확한 정량분석 방법을 개발하였다. 분석조건은 $C_{18}$분리관과 ELSD 검출기를 사용하였으며, 25mM ammonium acetate/acetonitrile의 기울기 용리에 의해 분리 되었다. 이때 검량선의 상관계수(correlation coefficient) $r^2=0.9993$, 정량범위 $50.3{\sim}604.1{\mu}g/ml$, 검출한계 $12.0{\mu}g/ml$ 및 정확성이 우수하였다. 이 방법은 화장품 중 Xanthan gum를 정확하고 간편하게 정량분석 가능함을 보여 주었다.

LC - MS/MS를 이용한 혈장과 뇨중에서 Vancomycin의 빠른정량분석 (Rapid Quantitative Analysis of Vancomycin in Human Plasma and Urine Using LC-MS/MS)

  • 김호현;노형진;한상범
    • 분석과학
    • /
    • 제15권5호
    • /
    • pp.410-416
    • /
    • 2002
  • 본 연구에서는 LC - MS/MS를 이용해 혈장과 뇨중에서 반코마이신을 신속하게 정량분석하는 방법을 개발하였다. 크로마토그래피는 $C_{18}$ XTerra MS 컬럼 ($2.1{\times}30mm$, $3.5{\mu}m$)을 사용하여 분석하였다. 이동상으로는 0.25% 초산이 섞인 10% 아세토니트릴 용액을 사용하였으며, 유속은 $250{\mu}L/min$이다. 반코마이신과 카페인 (내부표준물질)은 multiple reaction monitoring (MRM) 방법을 사용하여 검출하였으며 반코마이신은 precursor ion m/z 725.0 ( $[M+2H]^{2+}$)와 product ion m/z 100.0을 사용하였다. 혈장에서 반코마이신의 검출한계는 1 nM이며 좋은 정확성과 정밀성을 보여주었다. 또한 혈장중에서 반코마이신의 정량범위는 $0.01{\mu}M$ - $100{\mu}M$이다. 혈장과 뇨중에서 반코마이신을 정량하는 이 분석방법은 약물동력학연구 및 관련연구에 성공적으로 적용되었다.

주요산공재(主要散孔材) 구성요소(構成要素)의 방사방향(放射方向) 변동(變動)에 관한 연구(硏究) (Study on the Radial Variation of Structural Element in the Diffuse-Porous Woods)

  • 한철수
    • Journal of the Korean Wood Science and Technology
    • /
    • 제15권2호
    • /
    • pp.26-52
    • /
    • 1987
  • 우리나라에 분포도(分布度)가 높은 산공재(散孔材) 중에서 구조용재(構造用材)로서 뿐만 아니라 각종 특수용재(特殊用材)로서 이용도(利用度)가 높은 자작나무과(科) 3속(屬) 7수종(樹種)을 비롯한 6속(屬) 10수종(樹種)의 주요(主要) 구성요소(構成要素)의 방사방향(放射方向)에 따른 변동(變動)을 조사(調査)하였던 바 얻어진 결과(結果)를 요약(要約)하면 다음과 같다. 주요(王要) 구성요소(構成要素)의 치수는 수에 가까운 부위(部位)에서 일정(一定) 년륜(年輪)까지 급격히 증가(增加)한 후 거의 안정(安定)되는 직선형(直線型)(Type I), 완만하게 계속 증가(增加)하는 곡선형(曲線型)(Type II) 및 서서히 감소(減少)하는 포물선형(抛物線形)(Type III)으로 구분(區分)되며 동일수종내(同一樹種內)에서도 요소별(要素別)로 서로 다른 형(型) 공존(共存)하였다. 2. 목섬유(木織維)길이의 변이형(變異型)과 크기는 Type I은 자작나무 $1.35{\pm}0.10mm$, 거제수나무 $1.20{\pm}0.13mm$, 박달나무 $1.03{\pm}0.10mm$, 서어나무 $1.18{\pm}0.37mm$, 오리나무 $1.06{\pm}0.01mm$, 산벚나무 $0.81{\pm}0.16mm$였고, Type II는 사스래나무 $1.34{\pm}0.19mm$, 물박달나무 $1.20{\pm}0.29mm$였으며 Type III은 감나무 $0.95{\pm}0.13mm$였다. 목섬유(木纖維)의 폭(幅)의 변이형(變異型)과 크기는 Type I은 서어나무 $18.7{\pm}1.8{\mu}m$, 오리나무 $18.5{\pm}1.1{\mu}m$, 고로쇠나무 $14.5{\pm}2.4{\mu}m$였고, Type II는 사스래나무 $19.3{\pm}1.4{\mu}m$, 박달나무 $17.5{\pm}1.9{\mu}m$, 산벚나무 $14.8{\pm}5.4{\mu}m$였으며, Type III은 자작나무 $19.1{\pm}1.1{\mu}m$, 물박달나무 $20.3{\pm}3.4{\mu}m$, 거제수나무 $18.6{\pm}2.8{\mu}m$, 감나무 $18.9{\pm}4.3{\mu}m$였다. 3. 도관요소(導管要素) 길이의 변이형(變異型)과 크기는 Type I이 자작나무 $0.62{\pm}0.02mm$, 사스래나무 $0.90{\pm}0.09mm$, 박달나무 $0.64{\pm}0.08mm$, 산벚나무 $0.43{\pm}0.05mm$, 고로쇠나무 $0.31{\pm}0.03mm$였고 Type II는 물박달나무 $0.72{\pm}0.22mm$, 오리나무 $0.63{\pm}0.01mm$, 감나무 $0.17{\pm}0.06mm$였으며, Type III은 거제수나무 $0.75{\pm}0.10mm$, 서어나무 $0.66{\pm}0.16mm$였다. 도관요소(導管要素) 방사방향(放射方向) 직경(直徑)의 변이형(變異型)과 크기는 Type I이 자작나무 $58.7{\pm}11.3{\mu}m$, 서어나무 $67.1{\pm}10.1{\mu}m$, 오리나무 $60.0{\pm}10.3{\mu}m$ 였고, Type II가 사스래나무 $100.7{\pm}10.7{\mu}m$, 거제수 나무 $108.9{\pm}16.6{\mu}m$, 박달나무 $79.1{\pm}17.3{\mu}m$, 산벚나무 $47.5{\pm}21.3{\mu}m$, 감나무 $141.2{\pm}59.5{\mu}m$였으며, Type III은 물박달나무 $115.0{\pm}17.4{\mu}m$, 고로쇠나무 $57.1{\pm}11.4{\mu}m$였다. 도관요소(導管要素) 접선방향(接線方向) 직경(直徑)이 변이형(變異型)과 크기는 Type I이 자작나무 $54.8{\pm}13.5{\mu}m$, 서어나무 $57.1{\pm}11.7{\mu}m$, 오리나무 $44.9{\pm}13.0{\mu}m$였고, Type II는 사스래나무 $76.5{\pm}16.9{\mu}m$, 거제수나무 $87.1{\pm}17.3{\mu}m$, 박달나무 $65.6{\pm}9.2{\mu}m$, 산벚나무 $44.9{\pm}13.0{\mu}m$, 고로쇠나무 $34.8{\pm}10.4{\mu}m$였으며, Type III은 물박달나무 $86.0{\pm}13.6{\mu}m$, 감나무 $129.3{\pm}34.5{\mu}m$였다. 단위면적당(單位面積當) 관공(管孔)의 분포(分布)는 자작나무 $54.4{\pm}3.5$개, 사스래나무 $23.0{\pm}2.8 $개, 물박달나무 $19.5{\pm}2.5$개, 거제수나무 $20.8{\pm}2.6$개 박달나무 $17.6{\pm}2.7$, 서어나무 $87.5{\pm}14.7$개, 오리나무 $79.9{\pm}11.6$개, 산벚나무 $223.1{\pm}33.2$개, 고로쇠나무 $40.6{\pm}2.4$개, 감나무 $6.6{\pm}1.5$개였다. 4. 계단상(階段狀) 천공판(穿孔板)을 갖는 수종(樹種)의 천공판(穿孔板) 길이의 변이형(變異型)과 크기는 Type I은 자작나무 $143.5{\pm}16.4{\mu}m$, 거제수나무 $139.6{\pm}16.6{\mu}m$, 오리나무 $123.3{\pm}20.6{\mu}m$였고, Type II는 사스래나무 $144.9{\pm}17.9{\mu}m$, 물박달나무 $140.4{\pm}23.4{\mu}m$였으며, Type III은 박달나무 $108.7{\pm}19.7{\mu}m$였다. 판공판상(穿孔板上) bar수(數)의 변이형(變異型)과 수(數)는 Type I은 거제수나무 13.8{\pm}2.3개, 박달나무 $11.6{\pm}2.3$개였고, Type II은 물박달나무 $15.l{\pm}6.2$개였으며, Type III은 자작나무 $16.6{\pm}8.3$개, 사스래나무 $10.1{\pm}1.7$개, 오리나무 $17.1{\pm}7.9$ 개였다. 5. 방사조직(放射組織) 높이의 변이형(變異型)과 크기는 Type I이 사스래나무 $187.3{\pm}46.5{\mu}m$, 거제수나무 $209.9{\pm}48.4{\mu}m$였고, Type II는 자작나무 346.3{\pm}, $83.4{\mu}m$, 서어나무 $297.0{\pm}87.0{\mu}m$, 오리나무 $387.3{\pm}84.7{\mu}m$, 고로쇠나무 $244.8{\pm}74.0{\mu}m$였으며, Type III은 물박달나무 $233.7{\pm}66.1{\mu}m$, 박달나무 $172.9{\pm}47.9{\mu}m$, 산벚나무 $361.8{\pm}88.8{\mu}m$, 감나무 $304.8{\pm}87.3{\mu}m$였다. 방사조직(放射組織) 폭(幅)의 변이형(變異型)과 크기는 Type I이 거제수나무 $25.5{\pm}5.3{\mu}m$, 서어나무 $44.9{\pm}16.1{\mu}m$, 오리나무 $27.3{\pm}8.3{\mu}m$였고, Type II는 자작나무 $29.8{\pm}6.3{\mu}m$, 사스래나무 $23.6{\pm}5.0{\mu}m$, 물박달나무 $33.3{\pm}8.9{\mu}m$, 박달나무 $21.9{\pm}9.3{\mu}m$, 산벚나무 $39.2{\pm}10.1{\mu}m$, 고로쇠나무 $35.2{\pm}8.9{\mu}m$였으며, Type III은 감나무 $44.2{\pm}7.6{\mu}m$였다. 6. 목섬유(木纖維), 도관요소(導管要素), 방사조직(放射組織)의 치수의 변동(變動)을 고려(考慮)하여 미성숙재(未成熟材)와 성숙재(成熟材)를 구분(區分)하면 자작나무 45년륜(年輪), 사스래나무 43년륜(年輪), 물박달나무 34년륜(年輪), 거제수나무 53년륜(年輪), 박달나무 38년륜(年輪), 서어나무 44년륜(年輪), 오리나무 31년륜(年輪), 산벚나무 24년륜(年輪), 고로쇠나무 47년륜(年輪), 감나무 30년륜(年輪)이었다.

  • PDF

$0.18{\mu}m$ CMOS공정을 이용한UWB LNA (A Design on UWB LNA for Using $0.18{\mu}m$ CMOS)

  • 황인용;정하용;박찬형
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.567-568
    • /
    • 2008
  • 본 논문에서는 CMOS $0.18\;{\mu}m$ 공정을 이용하여 UWB LNA를 설계하였다. UWB LNA $3{\sim}5GHz$의 대역 에서 전력이득은 12-15 dB, 잡음지수는 5 dB이하, 그리고 입력과 출력의 반사손실은 10 dB 이하의 특성을 보이도록 하였다. 캐스코드 구조를 이용하여 잡음을 억제하고 이득을 향상시켰으며, 입력매칭에 공통 게이트 증폭기를 이용하여 대역폭을 증가시켰다.

  • PDF

PET검사 작업환경에 있어서 APRON의 방어에 대한 고찰 (A Consideration of Apron's Shielding in Nuclear Medicine Working Environment)

  • 이성욱;김승현;지봉근;이동욱;김정수;김경목;장영도;방찬석;백종훈;이인수
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.110-114
    • /
    • 2014
  • PET/CT기기의 발달로 인한 검사시간의 단축과 대중화로 인해 검사건수도 꾸준히 증가하고 있다. 이는 방사선 작업종사자의 피폭선량도 함께 증가시키는 결과를 초래한다. 본 연구는 PET/CT 검사에 있어서 에너지가 강한 $^{18}F-FDG$를 apron을 착용 시 방사선 차폐율을 측정하고 차폐효과를 알아보고자 하였다. 또한 $^{99m}TC$과의 차폐율을 비교하여 방사선 작업종사자의 피폭선량을 최소화하는 것에 목적을 두고 진행하였다. 실험방법은 2013년 5월 2일부터 5월 10일까지 8일간 PET/CT 검사를 위해 본원을 방문한 10명의 환자를 대상으로 하였고 PET/CT 주요 작업공간인 $^{18}F-FDG$ 분배실, 환자 안정실($^{18F}$주사 후 환자 대기장소), PET/CT 검사실 모두 3곳을 선정하여 Apron장착 전과 apron장착 후로 나누어 선량율 변화를 측정하였다. 정확한 측정을 위해서 환자 또는 Source부터의 거리는 1 m로 고정하였다. 또한 Apron의 선량감소율을 비교하고자 $^{99m}TC$의 source에도 같은 방법을 적용하여 측정하였다. 측정결과 $^{18F}FDG$ 분배실에서 L-BLOCK만 있는 경우 평균 $0.32{\mu}Sv$였고 L-block+apron의 경우 $0.23{\mu}Sv$이였으며 두 경우의 선량과 선량율의 차이는 각각 $0.09{\mu}Sv$, 26%로 나타났다. 안정실에서 apron이 없는 경우 평균 $33.1{\mu}Sv$였고 apron이 있는 경우 평균 $22.3{\mu}Sv$였다. 두 경우의 선량과 선량율의 차이는 각각 $10.8{\mu}Sv$, 33%로 나타났다. PET/CT실에서의 apron이 없는 경우 평균 $6.9{\mu}Sv$였고 apron이 있는 경우 평균 $5.5{\mu}Sv$였다. 두 경우의 선량과 선량율의 차이는 각각 $1.4{\mu}Sv$, 25%로 나타났다. $^{99m}TC$은 apron이 없는 경우 평균 $23.7{\mu}Sv$였고 apron이 있는 경우 평균 $5.5{\mu}Sv$였다. 두 경우의 선량과 선량율의 차이는 각각 $18.2{\mu}Sv$, 77%나타났다. 실험결과 환자에게 투여한 후의 $^{99m}TC$의 경우 평균 77%의 차폐율을 나타내었고 $^{18}F-FDG$의 경우 평균 27%의 비교적 낮은 차폐율을 보였다. source 자체만을 비교하였을 때에 $^{18}F-FDG$는 17%의 차폐율을 보였고 $^{99m}TC$은 77%의 차폐율을 보였다. $^{99m}TC$에 비해 낮은 차폐효과이지만 $^{18}F-FDG$ 역시 apron에 대한 차폐효과가 있음을 알 수 있었다. 그러므로 PET/CT 검사에 있어서 $^{18}F-FDG$과 같은 고에너지에 맞는 apron을 착용한다면 방사선 작업종사자의 피폭선량을 최소화 할 수 있을 것으로 사료된다.

  • PDF

Electrospray-Mass Spectrometric Analysis of Plasma Pyrophosphates Separated on a Multi-Modal Liquid Chromatographic Column

  • Lee, Su-Hyeon;Lee, Jeong-Ae;Lee, Won-Yong;Chung, Bong-Chul;Choi, Man-Ho
    • Mass Spectrometry Letters
    • /
    • 제2권4호
    • /
    • pp.92-95
    • /
    • 2011
  • Pyrophosphates are the key intermediates in the biosynthesis of isoprenoids, and their concentrations could reveal the benefits of statins in cardiovascular diseases. Quantitative analysis of five pyrophosphates, including isopentenyl pyrophosphate (IPP), dimethylallyl pyrophosphate (DMAPP), geranyl pyrophosphate (GPP), farnesyl pyrophosphate (FPP), and geranylgeranyl pyrophosphate (GGPP), was performed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in negative ionization mode. After dilution with methanol, samples were separated on a 3 ${\mu}m$ particle multi-modal $C_{18}$ column ($50{\times}2$ mm) and quantified within 10 min. The gradient elution consists of 10 mM ammonium bicarbonate and 0.5% triethylamine (TEA) in water and 0.1% TEA in 80% acetonitrile was used at the flow rate of 0.4 mL/min. Overall recoveries were 51.4-106.6%, while the limit of quantification was 0.05 ${\mu}g$/mL for GPP and FPP and 0.1 ${\mu}g$/mL for IPP, DMAPP, and GGPP. The precision (% CV) and accuracy (% bias) of the assay were 1.9-12.3% and 89.6-111.8%, respectively, in 0.05-10 ${\mu}g$/mL calibration ranges ($R^2$ > 0.993). The devised LC-MS/MS technique with the multi-modal $C_{18}$ column can be used to estimate the biological activity of pyrophosphates in plasma and may be applicable to cardiovascular events with cholesterol metabolism as well as the drug efficacy of statins.

HPLC-MS에 의한 Tri-Octyl Amine(TOA)의 방사선 분해산물 정량 (Determination of radiolysis products in Tri-Octyl Amine by high performance liquid chromatography-mass spectrometer)

  • 양한범;이일희;문형실
    • 분석과학
    • /
    • 제18권3호
    • /
    • pp.201-205
    • /
    • 2005
  • TOA의 방사선 분해산물중 TOA, DOA 및 MOA 함량을 액체크로마토그래피-질량분석기로 정량 분석하였다. Phenomenex LUNA-$C_{18}$ 분리관에서 $CH_3OH$$H_2O$(50 mmol $CH_3COONH_4$) 혼합용액을 이동상으로 하여 TOA, DOA 및 MOA의 머무름 거동을 살펴보았으며, 이동상의 부피비가 85 : 15일 때 방사선 분해산물의 분리가 가장 효율적이었다. MOA, DOA 및 TOA의 분리봉우리는 각각 2.7분, 4.3분, 그리고 16.6분에서 나타났으며, 측정 농도범위는 $30{\sim}160{\mu}g/mL$가 적합하였다. 이 범위에서 검량곡선은 $r2=0.999$의 좋은 상관관계를 보여주었으며, 시료량 $20{\mu}L$를 취할 경우에 SCAN mode에서 TOA, DOA 의 검출한계는 각각 $0.1{\mu}g/mL$, $1{\mu}g/mL$이었고, SIM mode에서 MOA의 검출한계는 $0.1{\mu}g/mL$이었다.

0.18-㎛ CMOS 공정을 이용한 6~18 GHz 8-비트 실시간 지연 회로 설계 (Design of a 6~18 GHz 8-Bit True Time Delay Using 0.18-㎛ CMOS)

  • 이상훈;나윤식;이성호;이성철;서문교
    • 한국전자파학회논문지
    • /
    • 제28권11호
    • /
    • pp.924-927
    • /
    • 2017
  • 본 논문에서는 6~18 GHz 대역 8-비트 true time delay(TTD) 회로의 설계 및 측정결과에 대하여 기술하였다. 단위 지연 회로는 상대적으로 시간 지연 변화율이 일정한 m-유도 필터(m-derived filter)를 이용하였다. 설계한 8-비트 TTD는 2개의 single-pole double-throw(SPDT)와 7개의 double-pole double-throw(DPDT) 스위치로 구현하였으며, 인덕터를 이용하여 반사 특성을 개선하였다. 설계된 8-비트 TTD는 $0.18{\mu}m$ CMOS 공정을 이용하여 제작하였다. 측정된 TTD 회로의 시간 가변 범위는 250 ps이고, 시간 지연 해상도는 약 1 ps이다. 6~18 GHz의 동작 주파수에서 RMS 시간 지연 오차는 11 ps 미만이며, 입출력 반사 손실은 10 dB 이상이다. 공급 전압은 1.8 V이며, 소비 전력은 0.0 mW이다. 칩 면적은 $2.36{\times}1.04mm^2$이다.