• 제목/요약/키워드: ${\gamma}electron$

검색결과 590건 처리시간 0.029초

An overview of new oxidation methods for polyacrylonitrile-based carbon fibers

  • Shin, Hye Kyoung;Park, Mira;Kim, Hak-Yong;Park, Soo-Jin
    • Carbon letters
    • /
    • 제16권1호
    • /
    • pp.11-18
    • /
    • 2015
  • The process of oxidizing polyacrylonitrile (PAN)-based carbon fibers converts them into an infusible and non-flammable state prior to carbonization. This represents one of the most important stages in determining the mechanical properties of the final carbon fibers, but the most commonly used methods, such as thermal treatment ($200^{\circ}C$ to $300^{\circ}C$), tend to waste a great deal of process time, money, and energy. There is therefore a need to develop more advanced oxidation methods for PAN precursor fibers. In this review, we assess the viability of electron beam, gamma-ray, ultra-violet, and plasma treatments with a view to advancing these areas of research and their industrial application.

감마선을 이용한 녹즙의 위생화 (Sanitizing Effect of $\gamma$-Irradiation on Fresh Vegetable-extract Juices)

  • 변명우;김미정;김재훈;육홍선;이경행
    • 한국식품영양과학회지
    • /
    • 제28권2호
    • /
    • pp.378-382
    • /
    • 1999
  • The sanitizing effect of irradiation on the fresh vegetable extract juices was investigated. Total bacteria, coliform bacteria and total ascorbic acid were determined during the storage periods at 4oC. Chlorophyll, carotenoid, tannin, electron donating ability and peroxidase activity were determined immediately after irradiation. Results showed that the viable cells were detected below the level of 105 CFU/ml during 12 days with doses of 3 and 5 kGy. Total ascorbic acid and tannin contents increased immediately after irradiation. However, irradiation didn't affect chlorophyll and car otenoid contents, electron donating ability, and peroxidase activity. It was considered that irradiation was effective in sanitizing fresh vegetable extract juices.

  • PDF

낮은 에너지 감마선과 베타선 모니터링을 위한 Gas Electron Multiplier 검출기의 효율성에 대한 연구 (Research of Efficiency for Gas Electron Multiplier Detector to Monitor Low Energy Gamma-Ray and Beta-Ray)

  • 이순혁;정재훈;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제25권2호
    • /
    • pp.95-99
    • /
    • 2014
  • 병원을 포함해서서 방사선 물질을 사용하는 모든 사업장에서 방사선 물질의 모니터링은 방사선 안전에 가장 중요한 요소의 하나이다. 본 연구는 방사선 모니터링 시스템에 있어서 GEM 검출기의 활용 가능성을 알아보기 위한 선행 연구로서, GEM 검출기를 제작하고 CdTe 검출기와의 상대적 효율을 구한 결과, 베타와 감마선에 대한 평균 상대 효율이 각각 72%와 4%로서 매우 우수한 성능을 나타냄을 보였다.

Investigation of Different Factors Affecting the Electron Spin Resomance-based Characterization of Gamma-irradiated Fresh, White, and Red Ginseng

  • Ahn, Jae-Jun;Akram, Kashif;Jo, Deok-Jo;Kwon, Joong-Ho
    • Journal of Ginseng Research
    • /
    • 제36권3호
    • /
    • pp.308-313
    • /
    • 2012
  • Fresh (raw roots), white (dried), and red (steamed-drid) ginseng samples were gamma-irradiated at 0 to 7 kGy. Electron spin resonance (ESR) technique was used to characterize the irradiation status of the samples, targeting the radiation-induced cellulose radicals after different sample pretreatments. All non-irradiated samples exhibited a single central signal (g=2.006), whose intensity showed significant increase upon irradiation. The ESR spectra from the radiation-induced cellulose radicals, with two side peaks (g=2.0201 and g=1.9851) equally spaced (${\pm}3mT$) from the central signal, were also observed in the irradiated samples. The core sample analyzed after alcoholic-extraction produced the best results for irradiated fresh ginseng samples. In the case of irradiated white and red ginseng samples, the central (natural) and radiation-induced (two-side peaks corresponding to cellulose radical) signal intensities showed little improvement on alcoholic-extraction. The water-washing step minimized the effect of $Mn^{2+}$, but reduced the intensity of side peaks making them difficult to indentify. The effect of different origins was negligible, however harvesting year showed a clear effect on radiation-induced ESR signals.

X-ray 컨테이너 화물검색시스템의 전자선형가속기 주변 콘크리트 차폐벽 내 방사화생성물에 대한 몬테카를로법 평가 (Monte carlo estimation of activation products induced in concrete shielding around electron linac used in an X-ray container inspection system)

  • 조영호
    • 한국산학기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.1035-1039
    • /
    • 2010
  • 고에너지 X-ray를 투시 방사선원으로 사용한 컨테이너 화물검색시스템에서 생성되는 광중성자에 의해 주변 콘크리트 차폐벽에서 발생되는 방사화생성물을 평가하였다. 몬테카를로 전산해석 코드인 MCNPX2.5.0을 사용하였으며, 참조시스템은 국내 주요 항만에 설치된 9MeV X-ray 고정식 양방향 컨테이너 화물검색시스템이다. 9MeV X-ray 조사에 따라 생성되는 광중성자의 (n,$\gamma$) 반응에 의한 방사화생성물 재고량을 계산하고 이에 따라 야기되는 방사선 피폭선량을 계산하였다.

FTIR study of gamma and electron irradiated high-density polyethylene for high dose measurements

  • Al-Ghamdi, Hanan;Farah, Khaled;Almuqrin, Aljawharah;Hosni, Faouzi
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.255-261
    • /
    • 2022
  • A reliable and well-characterized dosimetry system which is traceable to the international measurement system, is the key element to quality assurance in radiation processing with cobalt-60 gamma rays, X-rays, and electron beam. This is specifically the case for health-regulated processes, such as the radiation sterilization of single use medical devices and food irradiation for preservation and disinfestation. Polyethylene is considered to possess a lot of interesting dosimetric characteristics. In this work, a detailed study has been performed to determine the dosimetric characteristics of a commercialized high-density polyethylene (HDPE) film using Fourier transformed infrared spectrometry (FTIR). Correlations have been established between the absorbed dose and radiation induced infrared absorption in polyethylene having a maximum at 965 cm-1 (transvinylene band) and 1716 cm-1 (ketone-carbonyl band). We have found that polyethylene dose-response is linear with dose for both bands up to1000 kGy. For transvinylene band, the dose-response is more sensitive if irradiations are made in helium. While, for ketone-carbonyl band, the dose-response is more sensitive when irradiations are carried out in air. The dose-rate effect has been found to be negligible when polyethylene samples are irradiated with electron beam high dose rates. The irradiated polyethylene is relatively stable for several weeks after irradiation.

Preparation of cross-linked silk fibroin film by γ-irradiation and their application as supports for human cell culture

  • Park, Hyean-Yeol;Kim, Yoon-Seob;Choi, Seong-Ho
    • 분석과학
    • /
    • 제27권1호
    • /
    • pp.27-33
    • /
    • 2014
  • This study described about preparation of the cross-linked silk fibroin (SF) film by ${\gamma}$-irradiation of the casted SF film, which is fabricated from aqueous solution regenerated via fibers of cocoons and their application as supports for human cell culture. The properties of cross-linked SF film were evaluated by FT-IR spectroscopy, contact angle, solubility to water, thermal analysis, surface area analyzer, and morphology via scanning electron microscopy (SEM). The cross-linked SF films were not dissolved in water and exhibited the rough surface morphology, large surface area, and good thermal properties. The human fibroblast cell (CCD-986sk) and embryo kidney-ft cell were well growed on the surface of cross-linked SF film supports prepared by ${\gamma}$-irradiation. The cross-linked SF film prepared by ${\gamma}$-irradiation can be used as biomaterials for human cell culture.

APPLICATION OF ALANINE/ESR SPECTRUM SHAPE CHANGE IN GAMMA DOSIMETRY

  • Choi, Hoon;Kim, Jeong-In;Lee, Byung-Ill;Lim, Young-Ki
    • Nuclear Engineering and Technology
    • /
    • 제42권3호
    • /
    • pp.313-318
    • /
    • 2010
  • Alnine pellets were installed in a nuclear power plant for one or two operation cycles and measured by electron spin resonance (ESR) spectrometers for dosimetry. Dose and "x/y ratio", i.e., satellite peak over main center peak ratio, were measured for the returned alanine dosimeters from the nuclear power plant and compared to the values of reference alanine dosimeters exposed only to gamma rays. The variation of the x/y ratio change depended on the population of radicals from each radiation component with different LET. The gamma dose in a mixed radiation field was estimated by an additive gamma ray irradiation experiment and the measured dose rate at specified locations in the containment building.