• Title/Summary/Keyword: ${\gamma}-ray$

Search Result 1,793, Processing Time 0.028 seconds

Development of $^{192}Ir$ Small-Focal Source for Non-Destructive Testing Application by Using Enriched Target Material (고농축 표적을 이용한 비파괴검사용 $^{192}Ir$ 미세초점선원 개발)

  • Son, K.J;Hong, S.B.;Jang, K.D.;Han, H.S.;Park, U.J.;Lee, J.S.;Kim, D.H.;Han, K.D.;Park, C.D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.1
    • /
    • pp.31-37
    • /
    • 2007
  • A $^{192}Ir$ small-focal source has been developed by using the HANARO reactor and the radioisotope production facility at the Korea Atomic Energy Research Institute (KAERI). The small-focal source with the dimension of 0.5 mm in diameter and 0.5 mm in length was fabricated as an aluminum-encapsulated form by a specially designed pressing equipment. For the estimation of the radioactivity, neutron self-shielding and ${\gamma}-ray$ self-absorption effects on the measured activity was considered. From this estimation, it is realized that $^{192}Ir$ small-focal sources over 3 Ci activities can be produced from the HANARO. Field performance tests were performed by using a conventional source and the developed source to take images of a computer CPU and a piece of a carbon steel. The small-focal source showed better penetration sensitivity and geometrical sharpness than the conventional source does. It is concluded from the tests that the focal dimension of this source is small enough to maximize geometrical sharpness in the image taking for the close proximity shots, pipeline crawler applications and contact radiography.

A Study on the Provenance of the Stones and the Surface Cracks in the Suljeongri East Three-story Stone Pagoda, Changnyeong, Korea (창녕 술정리 동삼층석탑 석재의 원산지 해석 및 표면균열에 관한 연구)

  • Kim, Jae-Hwan;Jwa, Yong-Joo
    • The Journal of the Petrological Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.283-292
    • /
    • 2010
  • The Suljeongri east three-story stone pagoda in Changnyeong (National Treasure No. 34) has been damaged mainly by lots of cracks. The stones used for this pagoda are medium-granied equigranular pinkish biotite granite. Measured magnetic susceptibility values are of from 2 to 9 (${\times}10^{-3}$ SI unit). From the ${\gamma}$-ray spectrometer mesurement K, eU, and eTh contents of the stones are 3 to 7%, 8 to 19 ppm, and 11 to 35 ppm, respectively. Comparing the petrographical and chemical characteristics between the stones of the pagoda and the country rocks near Suljeongri, it is suggested that the most similar rock could be equigranular biotite granite in the western slope of the Mt. Hwawangsan. Vertical, horizontal and diagonal cracks are intensely developed at the lower part of the stone pagoda. Biotite granite has intrinsic microcracks defined as rift and grain rock cleavages. Both rock cleavages are assumed to have led to the crack growth and consequent mechanical damage of the pagoda. It seems that vertical cracks have been grown parallel to the principal compressional stress, and that horizontal cracks to the reacting tensional stress. Diagonal cracks seems likely to have been resulted from conjugate rift and grain rock cleavages.

Photocurrent Study on the Splitting of the Valence Band and Growth of CuAlSe2 Single Crystal Thin Film by Hot Wall Epitaxy (Hot Wall Epitaxy(HWE)법에 의한 CuAlSe2 단결정 박막의 성장과 가전자대 갈라짐에 대한 광전류 연구)

  • Park, Chang-Sun;Hong, Kwang-Joon;Park, Jin-Sun;Lee, Bong-Ju;Jeong, Jun-Woo;Bang, Jin-Ju;Kim, Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.157-167
    • /
    • 2004
  • A stoichiometric mixture of evaporating materials for $CuAlSe_{2}$ single crystal thin films was prepared from horizontal electric furnace. To obtain the single crystal thin films, $CuAlSe_{2}$ mixed crystal was deposited on thoroughly etched semi-insulating GaAs(100) substrate by the hot wall epitaxy (HWE) system. The source and substrate temperatures were $680^{\circ}C$ and $410^{\circ}C$, respectively. The crystalline structure of the single crystal thin films was investigated by the photoluminescence and double crystal X-ray diffraction (DCXD). The carrier density and mobility of $CuAlSe_{2}$ single crystal thin films measured with Hall effect by van der Pauw method are $9.24{\times}10^{16}cm^{-3}$ and $295cm^{2}/V{\codt}s$ at 293 K, respectively. The temperature dependence of the energy band gap of the $CuAlSe_{2}$ obtained from the absorption spectra was well described by the Varshni's relation, $E_{g}(T)$ = 2.8382 eV - ($8.68{\circ}10^{-4}$ eV/K)$T^{2}$/(T + 155 K). The crystal field and the spin-orbit splitting energies for the valence band of the $CuAlSe_{2}$ have been estimated to be 0.2026 eV and 0.2165 eV at 10 K, respectively, by means of the photocurrent spectra and the Hopfield quasicubic model. These results indicate that the splitting of the ${\Delta}so$ definitely exists in the ${\Gamma}_{5}$ states of the valence band of the $CuAlSe_{2}$. The three photocurrent peaks observed at 10 K are ascribed to the $A_{1-}$, $B_{1-}$, and $C_{1-}$ exciton peaks for n = 1.

Improvement of Inspection Methods using Lighting Signals and Guidebook for Non-English speaking Foreign Visitors (For chest X-ray Screening Examinees) (비영어권 외국인 내원객의 조명 신호와 안내서를 이용한 검사방법 개선 효과(흉부 방사선 검사자를 대상으로))

  • Kwak, Jong Hyeok;Choi, Min Gyeong;Kim, Neung Kyun;Kim, A Yeon;Kim, Gyeong Rip
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.577-584
    • /
    • 2020
  • In this study, the number of non-English speaking visitors is increasing day by day, and accordingly, there was a limitation in language communication and communication during radiographic examination. To this end, after distributing the handbook produced for inspection, the improvement effect of before and after explanation was examined. The score scale was not statistically significant as to whether it was the test site or not, and the degree of discomfort of the test, the degree of understanding of the breathing guidelines, and the satisfaction of the test description were improved and the score scale was improved before and after the description of the guide. Non-English-speaking foreign visitors were more satisfied with explanations in their own text than in English or Korean, and the method was also able to conduct effective inspections by informing the foreign guests when to control their breathing by using the lighting signals in the laboratory. In the future, the quality of medical services and imaging medical examinations can be improved only when communication methods are implemented from various perspectives, such as developing various language interpretation programs, developing guides for various test sites, and developing tools and improving foreign language skills of radiologists and medical staff. There will be. In the future, it may be used as a basic resource to prepare a manual that can be used to examine non-English speaking foreigners who do not understand English or Korean in other radiology labs.

Calculation of the Correction Factors related to the Diameter and Density of the Concrete Core Samples using a Monte Carlo Simulation (몬테카를로 전산해석을 이용한 콘크리트 코어시료의 직경과 밀도에 따른 보정인자 계산)

  • Lee, Kyu-Young;Kang, Bo Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.503-510
    • /
    • 2020
  • Concrete is one of the most widely used materials as the shielding structures of a nuclear facilities. It is also the most generated radioactive waste in quantity while dismantling facilities. Since the concrete captures neutrons and generates various radionuclides, radiation measurement and analysis of the sample was fulfilled prior to dismantle facilities. An HPGe detector is used in general for the radiation measurement, and effective correction factors such as geometrical correction factor, self-absorption correction, and absolute detector efficiency have to be applied to the measured data to decide exact radioactivity of the sample. Correction factors are obtained by measuring data using a standard source with the same geometry and chemical states as the sample under the same measurement conditions. However, it is very difficult to prepare standard concrete sources because concrete is limited in pretreatment due to various constituent materials and high density. In addition, the concrete sample obtained by core drill is a volumetric source, which requires geometric correction for sample diameter and self absorption correction for sample density. Therefore in recent years, many researchers are working on the calculation of effective correction factors using Monte carlo simulation instead of measuring them using a standard source. In this study we calculated, using Geant4, one of the Monte carlo codes, the correction factors for the various diameter and density of the concrete core sample at the gamma ray energy emitted from the nuclides 152Eu and 60Co, which are the most generated in radioactive concrete.

Evaluation of protective effect of peach kernel extracts on radiation-induced DNA damage in human blood lymphocytes in the single cell gel electrophoresis assay (단세포 겔 전기영동법을 이용한 사람 림프구 DNA 손상에 대한 복숭아씨 추출물의 방사선 방어효과 평가)

  • Kim, Jin-Kyu;Park, Tae-Won;Lee, Chang-Joo;Chai, Young-Gyu
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.2
    • /
    • pp.93-99
    • /
    • 1999
  • The alkaline single-cell gel electrophoresis (SCGE) assay, called the comet assay, has been applied to the detection of DNA damage from a number of chemical and biological factors in vivo and in vitro. The comet assay is a novel method to assess DNA single-strand breaks, alkali-labile sites in individual cells. The effect of peach kernel extracts on radiation-induced DNA damage in human blood lymphocytes was evaluated by the SCGE assay. The lymphocytes, with or without pretreatment of the extracts, were exposed to 0, 0.1, 0.3, 0.5, 1.0 and 2.0 Gy of $^{60}Co$ gamma ray. Significantly increased tail moment, which was a marker of DNA strand breaks in the comet assay, showed an excellent dose-response relationship. The treatment of the peach kernel extracts reduced the DNA damage by 30 % in irradiated groups as compared to that in non-treated control groups. The result indicates that the extracts shows radioprotective effect on lymphocyte DNA when assessed by the comet assay.

  • PDF

Combined Effects of Ionizing Radiation and Ultrasound on Malformation in ICR Mice at Organogenesis stage

  • Gu, Yeun-Hwa;Hasegawa, Takeo;Mori, Takehiko;Yamamoto, Youichi;Kusama, Tomoko
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.1
    • /
    • pp.23-30
    • /
    • 1999
  • Pregnant ICR mice were treated with 137Cs gamma-ray / ultrasound on day 8 of gestation. In combined treatments, pregnant mice were treated with both 1.5 Gy of radiation and $1.0W/cm^2$ ultrasound at time intervals of -1, 0, 1, 3 and 6 hours. The mortalities and external malformations were investigated on day 18 of gestation. The threshold dose of mortality induced by radiation on day 8 of gestation was between 0.5 and 1.0 Gy, and that which was induced by ultrasound was between 1.0 and $1.5W/cm^2$. The mortalities in the late-stage of gestation induced by combined treatment with radiation and ultrasound increased synergistically. The threshold dose of exencephaly and anophthalmia induced by radiation were between 0.5 and 1.0 Gy and between 1.0 and 1.5 Gy, respectively. Those of exencephaly and anophthalmia induced by ultrasound were between 1.0 and $1.5W/cm^2$ and more than $1.5W/cm^2$, respectively. In combined treatments, the incidence of exencephaly and anophthalmia were found to increase synergistically. In the mice treated with both agents at a time interval of one hour, the incidence of exencephaly and anophthalmia reached maximum levels.

  • PDF

A Study on the Validation of Effective Angle of Particle Deposition according to the Detection Efficiency of High-purity Germanium Gamma-ray Detector (고순도 저마늄 감마선 검출기의 검출효율에 따른 유효입체각 검증에 관한 연구)

  • Chang, Boseok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.487-494
    • /
    • 2020
  • The distance between the source and the detector, the diameter of the detector, and the volume effect of the radiation source result in a change in solid angle at the detector entrance, which affects the determination of detection efficiency by causing a difference in path length within the detector. A typical analysis method for calculating solid angles was useful only for a source (60Co) with a simple geometric structure, so in this experiment, the distance between the detector and the source was measured by switching on for up to 25 cm with the reference point of window cap 0.5 cm. In addition, 450 and 1000 ㎖ Marinelli beaker of standard volumetric sources were closely adhered to the detector. For circular point sources co-axial with the detector, the change in the solid angle to the distance from the detector window is equal to half the square radius of the source versus the square radius of the detector, if the resulting relationship of the calculation analysis results in the detector being less than the radius of the source. Since the solid angular difference is 0.5 the result of Monte Carlo is acceptable. The relationship between detector and source distance is shown. Solid angles have been verified to decrease rapidly with distance. Measurement and simulation results for a volumetric source show a difference of ±1.01% from a distance of 0 cm and less than 4 % when the distance is reduced to 5 and 10 cm. It can be seen that the longer distance, the smaller efficiency angle, and the exponential increase in attenuation as the energy decreases, is reflected in the calculation of efficiency. Thus, the detection efficiency has proved sufficient for the use of solid angle and Monte Carlo codes.

Incidence of Micronuclei in Lymphocytes of Cattle in the High Background Radiation Area (자연방사선 고준위 지역 사육 소의 림프구 미소핵 발생 평가)

  • Lee, Hae-June;Kang, Chang-Mo;Kim, Se-Ra;Moon, Chang-Jong;Kim, Jong-Choon;Kim, Ill-Hwa;Jo, Sung-Kee;Jang, Jong-Sik;Kim, Sung-Ho
    • Toxicological Research
    • /
    • v.22 no.4
    • /
    • pp.417-422
    • /
    • 2006
  • Cytogenetic and hematological analysis was performed in peripheral blood obtained from cattle bred in the high background radiation areas (HBRA, Goesan-gun, Cheongwon-gun, Boeun-gun) and a control area. The frequencies of gamma-ray induced micronuclei (MN) in the cytokinesis-blocked (CB) lymphocytes at several doses were measured in 3 cattle. An estimated dose of radiation was calculated by a best fitting linear-quadratic model based on the radiation-induced MN formation from the bovine lymphocytes exposed in vitro to radiation over the range from 0 mGy to 1,969 mGy. The measurements performed after irradiation showed dose-related increases in the MN frequency in each donors. The results were analyzed using a linear-quadratic model with a line of best fit of $y=(0.0583{\pm}0.0137)D+(0.0366{\pm}0.0081)D^2+(0.0093{\pm}0.0015)$ (y=number of MN/CB cells and D=irradiation dose in Gy). MN rates per 1,000 CB lymphocytes of cattle from the Goesan-gun, Cheongwon-gun, Boeun-gun and the control area were $6.50{\pm}2.72,\;9.00{\pm}4.50,\;10.89{\pm}4.23\;and\;9.60{\pm}4.70$, respectively. The MN frequencies of CB lymphocytes from cattle bred in 4 areas mean that the values are within the background variation in this experiment. The MN frequencies and hematological values were similar regardless of whether the cattle were bred in the HBRA or the control area.

Selection and Agronomic Traits of Radiation-induced Variants in Rice (방사선 이용 벼 돌연변이 계통 선발 및 농경 형질조사)

  • Lee, In-Sok;Kim, Dong-Sub;Lee, Sang-Jae;Song, Hi-Sub;Lim, Yong-Pyo;Lee, Young-Il
    • Journal of Plant Biotechnology
    • /
    • v.30 no.1
    • /
    • pp.19-25
    • /
    • 2003
  • Radiation technique in agriculture was initiated to develop mutant rice. Seeds of Daechungbyeo rice were irradiated with 250 Gy gamma ray for the purpose of inducing and selecting rice variants. Some quantitative traits of the variants in M$_{8}$ generation were evaluated and RAPD analysis was carried out. Variants showed a wider range of agronomic characteristics in both a positive and a negative direction compared with their original variety. The new mutants were characterized by an increased or decreased in plant height, lodging resistance and shorter panicle. RAPD analysis showed that polymorphic bands were presented in most of the primers. In comparison with the original variety, variants were classified into four groups through UPGMA analysis. Among mutants no. 91, 139, 140 and 141 was ranked as salt tolerance and the proline content of these mutants was more increased than that of original variety. The lines of 139, 140 and 141 had the highest genetic distance as compared to original variety in the dendrogram. It is expected that such variants will be useful not only for studying molecular genetics but also for breeding research and genetic analysis.s.