Concrete is one of the most widely used materials as the shielding structures of a nuclear facilities. It is also the most generated radioactive waste in quantity while dismantling facilities. Since the concrete captures neutrons and generates various radionuclides, radiation measurement and analysis of the sample was fulfilled prior to dismantle facilities. An HPGe detector is used in general for the radiation measurement, and effective correction factors such as geometrical correction factor, self-absorption correction, and absolute detector efficiency have to be applied to the measured data to decide exact radioactivity of the sample. Correction factors are obtained by measuring data using a standard source with the same geometry and chemical states as the sample under the same measurement conditions. However, it is very difficult to prepare standard concrete sources because concrete is limited in pretreatment due to various constituent materials and high density. In addition, the concrete sample obtained by core drill is a volumetric source, which requires geometric correction for sample diameter and self absorption correction for sample density. Therefore in recent years, many researchers are working on the calculation of effective correction factors using Monte carlo simulation instead of measuring them using a standard source. In this study we calculated, using Geant4, one of the Monte carlo codes, the correction factors for the various diameter and density of the concrete core sample at the gamma ray energy emitted from the nuclides 152Eu and 60Co, which are the most generated in radioactive concrete.
Keywords
Monte Carlo Simulation; Geant4; HPGe detector; Geometrical correction; Self-absorption correction;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 K. Masumoto, A. Toyoda, K. Eda, Y. Izumi, T. Shibata, "Evaluation of radioactivity induced in the accelerator building and its application to decontamination work", Journal of Radioanalytical and Nuclear Chemistry, Vol. 255, No.3, pp. 465-469, 2003. http://dx.doi.org/10.1023/A:1022511811356   DOI
2 Q. B. Wang, K. Masumoto, K. Bessho, H. Matsumura, T. Miura, T. Shibata, "Evaluation of the radioactivity in concrete from acclerator facilities", Journal of Radioanalytical and Nuclear Chemistry, Vol. 273, No. 1, pp. 55-58, 2007. http://dx.doi.org/10.1007/s10967-007-0710-3   DOI
3 Sharshar T., Elnimr T., El-Husseiny F. A, El-Abd A., "Efficiency Calibration of HPGe Detectors for Volume-source Geometries", Applied Radiation and Isotopes, Vol. 48, No. 5, pp. 695-697, 1997. http://dx.doi.org/10.1016/S0969-8043(97)00004-3   DOI
4 M. Mostajaboddavati, S. Hassanzadeh, H. Faghihian, M. R. Abdi, M. Kamali, "Efficiency calibration and measurement of self-absorption correction for environmental gamma-spectroscopy of soil samples using Marinelli beaker", Journal of Radioanalytical and Nuclear Chemistry, Vol. 268, No. 3, pp. 539-544, 2006. http://dx.doi.org/10.1007/s10967-006-0202-x   DOI
5 E. ROBU, C. GIOVANI, "Gamma-ray self-attenuation corrections in environmental samples", Romanian Reports in Physics, Vol. 61, No. 2, pp. 295-300, 2009.
6 Octavian Sima, Dirk Arnold, "On the Monte carlo simulation of HPGe gamma-spectrometry systems", Applied Radiation and Isotopes, Vol. 67, No. 5, pp. 701-705, 2009. http://dx.doi.org/10.1016/j.apradiso.2009.01.014   DOI
7 Gleun F. Knoll, Radiation Detection and Measurement, 4th Ed., Hamilton Printing Company, United States of America, pp. 121, 2010.
8 R. Britton, J. Burnett, A. Davies, P. H. Regan, "Determining the efficiency of a broad-energy HPGe detector using Monte Carlo simulations", Journal of Radioanalytical and Nuclear Chemistry, Vol. 295, No. 3, pp. 2035-2041, 2013. http://dx.doi.org/10.1007/s10967-012-2203-2   DOI
9 J. D. Nikolic, D. Jokovic, D. Todorovic, M. Rajacic, "Application of GEANT4 simulation on calibration of HPGe detectors for cylinderical environmental samples", Journal of Radiological Protection, Vol. 34, No. 2, pp. 47-55, 2014. http://dx.doi.org/10.1088/0952-4746/34/2/N47
10 M. J. Vargas, A. F. Timon, N. C. Diaz, D. P. Sanchez, "Influence of the geometrical characteristics of an HpGe detector on its efficiency", Journal of Radioanalytical and Nuclear Chemistry, Vol. 253, No. 3, pp. 439-443, 2002. http://dx.doi.org/10.1023/A:1020425704745   DOI
11 https://physics.nist.gov/
12 S. B. Hong, B. K. Seo, D. K. Cho, G. H. Jeong, J. K. Moon, "A Study on the Inventory Estimation for the Activated Bioshield Concrete of KRR-2", Journal of Radiation Protection and Research, Vol. 37, No. 4, pp. 202-207, 2012. https://doi.org/10.14407/jrp.2012.37.4.202   DOI