• Title/Summary/Keyword: ${\gamma}-ray$

Search Result 1,812, Processing Time 0.026 seconds

Radiation-induced DNA strand breaks in EL4 cells and mouse spleen lymphocytes (방사선에 의한 EL4 마우스 백혈병세포 및 정상 마우스 비장 임파구 DNA strand breaks의 측정)

  • Kim, Sung-ho;Kim, Tae-hwan;Chung, In-yong;Yoo, Seong-yul;Cho, Chul-koo;Chin, Soo-yil
    • Korean Journal of Veterinary Research
    • /
    • v.31 no.3
    • /
    • pp.329-335
    • /
    • 1991
  • The filter elution technique was used to assay $^{60}Co$ $\gamma$ ray-induced DNA strand breaks(SB) in EL4 mouse leukemia cell and mouse spleen lymphocyte. The lymphocytes were stimulated with lipopolysaccharide (LPS, $20{\mu}g/ml$) to label $[^3H]$ thymidine. EL4 cells and lymphocytes in suspension were exposed at $0^{\circ}C$ to 0Gy, 1Gy, 5Gy, 10Gy or l5Gy for DNA single strand breaks(SSB) assay and 0Gy, 25Gy, 50Gy, 75Gy or 100Gy for DNA double strand breaks(DSB) assay of $^{60}Co$ radiation and elution procedure was performed at pH12.1 and 9.6. The number of DNA strand breaks increased with increasing doses of r rays. The strand scission factor(SSF) was estimated in each experiment (eluted volume 21ml). The slope of SSB EL4 cells was $0.01301{\pm}0.00096Gy^{-1}$ (n=5), the slope of SSB for lymphocytes was $0.01097{\pm}0.00091Gy^{-1}$ (n=5) and the slope of DSB for lymphocytes was $0.001707{\pm}0.0000573Gy^{-1}$ (n=5). Thus EL4 cells were more sensitive to induction of DNA SSB by ionizing radiation than lymphocytes (p<0.005). The ratio of slope of dose-response relationship (SSF versus dose) of lymphocytes DNA SSB as compared with the slope of DNA DSB was 6.4.

  • PDF

Protective Effects of a Herb, Menthae Herba, against Radiation-induced Oxidative DNA Damage

  • Jo, Sung-Kee;H, Heon-O;Uhee Jung;Kim, Sung-Ho;Byun, Myung-Woo
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.10a
    • /
    • pp.152-152
    • /
    • 2003
  • As utilization of radiation in medicine, industry and biochemical research increases, the protection against radiation damage has become an important issue. Natural products such as herbal medicines are beginning to receive attention as modifiers on the radiation response. In the present study, the protective effect of a herb, Menthae Herba, against radiation-induced DNA damage was evaluated using alkaline single-cell gel electrophoresis (SCGE; comet assay) in the mouse peripheral blood Iymphocytes and the micronucleus formation test in the Chinese hamster ovary (CHO) cells. The tail moment, which was a marker of DNA damage in the SCGE, and the frequency of micronuclei was decreased in groups treated with Mentae Herba extract before exposure to 200 cGy of gamma-ray. We also confirmed its activities to scavenge DPPH and hydroxyl radicals. These experiments demonstrated that Menthae Herba was effective at reducing the radiation-induced damage of DNA and scavenging free radicals. It is plausible that scavenging of free radicals by Menthae Herba may have played an important role in providing the protection against the radiation-induced damage to the DNA. These results indicated that Menthae Herba might be a useful radioprotector and that radical scavenging appears to be one of the mechanisms of radiation protection.

  • PDF

A Simultaneous Determination of Chromium, Iron, Lanthanum, Scandium and Zinc in River Water by Neutron Activation (중성자 방사화에 의한 시료중의 크롬, 철, 란탄, 스칸듐 및 아연의 동시정량)

  • Lee Ihn Chong;Kim Si-Joong;Lee Chul
    • Journal of the Korean Chemical Society
    • /
    • v.21 no.6
    • /
    • pp.427-433
    • /
    • 1977
  • A neutron activation method has been developed for the simultaneous determination of chromium, iron, lanthanum, scandium and zinc in river-water samples. The sample is sealed in the silica ampoule without pretreatment and irradiated for a week at a thermal neutron flux of $1{\times}10^{13}n{\cdot}cm^{-2}{\cdot}sec^{-1}$. After cooling for about two days, the elements in the sample are sequentially extracted at different pH by 0.1M oxine-chloroform solution. The organic layers are checked by Gamma-ray spectrometry with $″3\;{\times}\;3″$ NaI (T1) detector connected to a 800-channel pulse hight analyzer. The ppb concentration of the elements in most of river-water samples could be determined by this method. The tracer study for the quantitative separation of the elements was also carried out.

  • PDF

Crystal Structures of the Two Isomorphous A-DNA Decamers d(GTACGCGTAC) and d(GGCCGCGGCC)

  • Kim, Tae-gyun;Kwon, Taek-Hun;Jung, Hye-sun;Ku, Ja-Kang;Sundaralingam, Muttaiya;Ban, Chang-ill
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.4
    • /
    • pp.568-572
    • /
    • 2006
  • To study the effect of sequence on DNA structure, the two decamer crystal structures one alternating,d(GTACGCGTAC), and the other non-alternating, d(GGCCGCGGCC), were solved. Crystals of both decamers belong to the hexagonal space group $P6_122$, with one strand in the asymmetric unit. The unit cell constants of the alternating decamer are a = b = 39.26 $\AA$, c = 77.70 $\AA$. The structure was refined with 1,828 reflections from 8.0 to 2.0 Aresolution to an R value of 21.3% with all DNA atoms and 63 water molecules. The isomorphous non-alternating decamer had unit cell dimensions of a = b = 39.05 $\AA$, c = 82.15 $\AA$. The structure was refined with 2,423 reflections from 8.0 to 2.0 $\AA$ resolution to a final R value of 22.2% for all DNA atoms and 65 water molecules. Although the average helical parameters of the decamers are typical of A-DNAs, there are some minor differences between them. The helical twist, rise, x-displacement, inclination and roll alternate in the alternating decamer, but do not in the non-alternating decamer. The backbone conformations in both structures show some differences; the residue G(7) of the alternating decamer is trans for $\alpha$ and $\gamma$ while the trans conformations are observed at the residue G(8) of the non-alternating decamer.

Evaluation of the Efficacy of Zoledronic Acid and Amifostine on Radiation-induced Bone Loss in Mice

  • Kim, Jinwook;Lee, Sueun;Kang, Sohi;Moon, Changjong;Kim, Jong-Choon;Jung, Uhee;Jo, Sung-Kee;Jang, Jong-Sik;Kim, Sung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.253-259
    • /
    • 2016
  • Background: This study investigated the effects of zoledronic acid (ZA) on radiation-induced bone loss in C3H/HeN mice. Materials and Methods: C3H/HeN mice were divided into sham control and three irradiated groups (3 Gy, gamma ray). The irradiated mice were treated for 12 weeks with vehicle, amifostine (intraperitoneal injection), or ZA (subcutaneous injection). Grip strength, uterus weight, and serum alkaline phosphatase (ALP), and tartrate-resistant acid phosphatase (TRAP) levels were measured. Tibiae were analyzed using micro-computed tomography. Results and Discussion: Treatment of ZA ($100{\mu}g{\cdot}kg^{-1}{\cdot}week^{-1}$) significantly preserved trabecular bone volume, trabecular thickness, trabecular number, trabecular separation, bone mineral density of proximal tibia metaphysic, and cortical bone volume, but did not alter the uterus weight of the mice. The administration of ZA for 12 weeks lowered serum ALP and TRAP levels in irradiated mice, suggesting that ZA can reduce the bone turnover rate in mice. No differences were apparent between the amifostine-treated group and the irradiation control group. Conclusion: The results indicate that ZA can prevent radiation-induced bone loss in mice.

Ultra Fast Flash Observatory to observe the prompt photons from Gamma Ray Bursts

  • Nam, Ji-Woo;Boggs, Steven;Ripov, G.;Grossan, Bruce;Jeon, Jin-A;Jin, Joo-Young;Jung, Ae-Ra;Kim, Ji-Eun;Kim, Min-Soo;Kim, Yong-Kweon;Klimov, P.;Khrenov, B.;Lee, Chang-Hwan;Lee, Jik;Na, Go-Woon;Nam, Shin-Woo;Park, Il-Heung;Park, Jae-Hyoung;Park, Yong-Sun;Smoot, S.F.;Suh, Jung-Eun;Yoo, Byoung-Wook
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.34 no.1
    • /
    • pp.120.1-120.1
    • /
    • 2009
  • PDF

The Study for the Fast Detection of the Stereo Radiation Detector using the Image Processing (영상처리기반 스테레오 감마선 탐지장치의 고속탐지에 관한 연구)

  • Hwang, Young-gwan;Lee, Nam-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1103-1105
    • /
    • 2015
  • Leaked Radioactive source in nuclear power station, radiation related facilities and the aging nuclear power plant for the dismantling must need to detect and remove early to prevent major accidents. In this paper, we implemented a single sensor-based gamma-ray detectors stereo which can provide the distance to the radiation source, a direction and doserate information for fast and efficient decontamination work the radiation source. And we have carried out an algorithm development for high-speed detection of the detection equipment. Two detectors are required for stereo structure for obtaining the distance information of the radioactive source, but we designed the only sensor-based detection device for the weight reduction. We have extracted the region of interest and obtained the distance calculation result and distribution of radiation source in order to minimize a stereo image acquisition time. Detection time of the algorithm showed a shorter time of about 41%.

  • PDF

Post Annealing Effects on Iron Oxide Nanoparticles Synthesized by Novel Hydrothermal Process

  • Kim, Ki-Chul;Kim, Young-Sung
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.179-184
    • /
    • 2010
  • We have investigated the effects of post annealing on iron oxide nanoparticles synthesized by the novel hydrothermal synthesis method with the $FeSO_4{\cdot}7H_2O$. To investigate the post annealing effect, the as-synthesized iron oxide nanoparticles were annealed at different temperatures in a vacuum chamber. The morphological, structural and magnetic properties of the iron oxide nanoparticles were investigated with high resolution X-ray powder diffraction (XRD), high resolution transmission electron microscopy (HRTEM), Mossbauer spectroscopy, and vibrating sample magnetometer analysis. According to the XRD and HRTEM analysis results, as-synthesized iron oxide nanoparticles were only magnetite ($Fe_3O_4$) phase with face-centered cubic structure but post annealed iron oxide nanoparticles at $700^{\circ}C$ were mainly magnetite phase with trivial maghemite ($\gamma-Fe_2O_3$) phase which was induced in the post annealing treatment. The crystallinity of the iron oxide nanoparticles is enhanced by the post annealing treatment. The particle size of the as-synthesized iron oxide nanoparticles was about 5 nm and the particle shape was almost spherical. But the particle size of the post annealed iron oxide nanoparticles at $700^{\circ}C$ was around 25 nm and the particle shape was spherical and irregular. The as-synthesized iron oxide nanoparticles showed superparamagnetic behavior, but post annealed iron oxide nanoparticles at $700^{\circ}C$ did not show superparamagnetic behavior due to the increase of particle size by post annealing treatment. The saturation of magnetization of the as-synthesized nanoparticles, post annealed nanoparticles at $500^{\circ}C$, and post annealed nanoparticles at $700^{\circ}C$ was found to be 3.7 emu/g, 6.1 emu/g, and 7.5 emu/g, respectively. The much smaller saturation magnetization value than one of bulk magnetite can be attributed to spin disorder and/or spin canting, spin pinning at the nanoparticle surface.

A Numerical Study of Different Types of Collimators for a High-Resolution Preclinical CdTe Pixelated Semiconductor SPECT System

  • Jeong, Hyun-Woo;Kim, Jong Seok;Bae, Se Young;Seo, Kanghyen;Kim, Seung Hun;Kang, Seong Hyeon;Shin, Dong Jin;Lee, Chang-Lae;Kim, Kyuseok;Lee, Youngjin
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.663-668
    • /
    • 2016
  • In single-photon-emission computed tomography (SPECT) with a pixelated semiconductor detector (PSD), not only pinhole collimators but also parallel-hole collimators are often used in preclinical nuclear-medicine imaging systems. The purpose of this study was to evaluate and compare pinhole and parallel-hole collimators in a PSD. For that purpose, we paired a PID 350 (Ajat Oy Ltd., Finland) CdTe PSD with each of the four collimators most frequently used in preclinical nuclear medicine: (1) a pinhole collimator, and (2) low-energy high-resolution (LEHR), (3) low-energy general-purpose (LEGP), and (4) low-energy high-sensitivity (LEHS) parallel-hole collimators. The sensitivity and spatial resolution of each collimator was evaluated using a point source and a hot-rod phantom. The highest sensitivity was achieved using LEHS, followed by LEGP, LEHR, and pinhole. Also, at a source-to-collimator distance of 2 cm, the spatial resolution was 1.63, 2.05, 2.79, and 3.45 mm using pinhole, LEHR, LEGP, and LEHS, respectively. The reconstructed hot-rod phantom images showed that the pinhole collimator and the LEHR parallel-hole collimator give a fine spatial resolution for preclinical SPECT with PSD. In conclusion, we successfully compared different types of collimators for a preclinical pixelated semiconductor SPECT system.

Development of distinction methods for male-sterile and dwarfism herbicide tolerant Zoysia japonica Steud (웅성불임 및 왜성형질의 제초제저항성 들잔디(zoysia japonica Steud.)의 판별기술 개발)

  • Lee, Bum Kyu;Kang, Hong-Gyu;Ra, Nu Ri;Sun, Hyeon-Jin;Kwon, Yong-Ik;Song, In-Ja;Kim, Chang-Gi;Ryu, Tae-Hun;Park, Kee Woong;Lee, Hyo-Yeon
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.3
    • /
    • pp.187-191
    • /
    • 2014
  • The cultivation area and use of genetically modified (GM) crops have been increased continuously over the world. Concerns about the potential risks of GM crops are also increasing. Safe management for the development and production of GM crops is required according to Living Modified Organism Act in Korea. Planning about the methods, duration, and frequency of environmental monitoring is also required for commercial use of GM crops. GM Zoysia japonica Steud. (event name: JG21) expressing resistance to glufosinate-ammonium has been generated previously. By using gamma ray treatment to JG21 we also developed male sterility and dwarf Z. japonica (event name: JG21-MS). The objective of this study was to establish the monitoring system for environment release of JG21-MS. In this study we extracted RNA from JG21 and JG21-MS and conducted RAPD (random amplified polymorphic DNA) method to distinguish JG21 and JG21-MS.