Reports of constitutional ring chromosome 22, r(22) are rare. Individuals with r(22) present similar features as those with the 22q13 deletion syndrome. The instability in the ring chromosome contributes to the development of variable phenotypes. Central nervous system (CNS) atypical teratoid rhabdoid tumors (ATRTs) are rare, highly malignant tumors, primarily occurring in young children below 3 years of age. The majority of ATRT cases display genetic alterations of SMARCB1 (INI1/hSNF5 ), a tumor suppressor gene located on 22q11.2. The coexistence of a CNS ATRT in a child with a r(22) is rare. We present a case of a 4-month-old boy with 46,XY,r(22)(p13q13.3), generalized hypotonia and delayed development. High-resolution microarray analysis revealed a 3.5-Mb deletion at 22q13.31q13.33. At 11 months, the patient had an ATRT ($5.6cm{\times}5.0cm{\times}7.6cm$) in the cerebellar vermis, which was detected in the brain via magnetic resonance imaging.
An accurate preoperative localization in patients with primary hyperparathyroidism is important for successful surgical intervention. There are many methods for the localization of the primary hyperparathyroidism such as ultrasonography, computerized tomography(CT), magnetic resonance imaging(MRI), angiography and $^{201}T1/^{99m}Tc$ subtraction scan. Among them $^{201}T1/^{99m}Tc$ subtraction scan is known as the most accurate tool for preoperative localization. Recently $^{99m}Tc$-Sestamibi has been used for parathyroid gland imaging. We experienced 19 primary hyperparathyroidisms accurately localized with $^{201}T1/^{99m}Tc$ subtraction imaging and $^{99m}Tc$-Sestamibi. The sensitivities of the $^{99m}Tc$-Sestanibi, $^{201}T1/^{99m}Tc$ subtraction imaging, CT and US were 100%(5/5), 89.5%(17/19) and 61.7(12/19) respectively. With the combination of $^{99m}Tc$-Sestamibi and $^{201}T1/^{99m}Tc$ subtraction imaging we could localize with 100% accuracy. Although the case number is small, this study suggests that the $^{99m}Tc$-Sestamibi parathyroid scan is very useful and easy to use for preoperative localization in primary hyperparathyroidism.
Yeon Soo Kim;Su Hyun Lee;Soo-Yeon Kim;Eun Sil Kim;Ah Reum Park;Jung Min Chang;Vivian Youngjean Park;Jung Hyun Yoon;Bong Joo Kang;Bo La Yun;Tae Hee Kim;Eun Sook Ko;A Jung Chu;Jin You Kim;Inyoung Youn;Eun Young Chae;Woo Jung Choi;Hee Jeong Kim;Soo Hee Kang;Su Min Ha;Woo Kyung Moon
Korean Journal of Radiology
/
v.25
no.1
/
pp.11-23
/
2024
Objective: To investigate whether reader training improves the performance and agreement of radiologists in interpreting unenhanced breast magnetic resonance imaging (MRI) scans using diffusion-weighted imaging (DWI). Materials and Methods: A study of 96 breasts (35 cancers, 24 benign, and 37 negative) in 48 asymptomatic women was performed between June 2019 and October 2020. High-resolution DWI with b-values of 0, 800, and 1200 sec/mm2 was performed using a 3.0-T system. Sixteen breast radiologists independently reviewed the DWI, apparent diffusion coefficient maps, and T1-weighted MRI scans and recorded the Breast Imaging Reporting and Data System (BI-RADS) category for each breast. After a 2-h training session and a 5-month washout period, they re-evaluated the BI-RADS categories. A BI-RADS category of 4 (lesions with at least two suspicious criteria) or 5 (more than two suspicious criteria) was considered positive. The per-breast diagnostic performance of each reader was compared between the first and second reviews. Inter-reader agreement was evaluated using a multi-rater κ analysis and intraclass correlation coefficient (ICC). Results: Before training, the mean sensitivity, specificity, and accuracy of the 16 readers were 70.7% (95% confidence interval [CI]: 59.4-79.9), 90.8% (95% CI: 85.6-94.2), and 83.5% (95% CI: 78.6-87.4), respectively. After training, significant improvements in specificity (95.2%; 95% CI: 90.8-97.5; P = 0.001) and accuracy (85.9%; 95% CI: 80.9-89.8; P = 0.01) were observed, but no difference in sensitivity (69.8%; 95% CI: 58.1-79.4; P = 0.58) was observed. Regarding inter-reader agreement, the κ values were 0.57 (95% CI: 0.52-0.63) before training and 0.68 (95% CI: 0.62-0.74) after training, with a difference of 0.11 (95% CI: 0.02-0.18; P = 0.01). The ICC was 0.73 (95% CI: 0.69-0.74) before training and 0.79 (95% CI: 0.76-0.80) after training (P = 0.002). Conclusion: Brief reader training improved the performance and agreement of interpretations by breast radiologists using unenhanced MRI with DWI.
Purpose: We Investigated to achieve high resolution magnetic resonance (MR) Imaging and spectra of human skin in vitro with using a 14.1 T MRI/MRS system, and to evaluate the hydration effect of a moisturizer by measuring the skin's water concentration. Materials and Methods: We used the Brukrer 14.1 T MRI/MRS system with a vertical standard bore that was equipped with a DMX spectrometer gradient system (200 G/cm at a maximum 40 A), RF resonators (2, 5 and 10 mm) and Para Vision software. Spin echo and fast spin echo pulse sequences were employed for obtaining the high resolution MR images. The 3D-localized point resolved spectroscopy (PRESS) method was used to acquire the MR spectra. Results: The high resolution MR images and spectra of human skin in vitro were successfully obtained on a 14.IT system. The water concentration of human skin after applying a moisturizer was higher than that before applying a moisturizer. Conclusions: The present study demonstrated that the high-resolution MR images and spectra of human skin from a high field MRS instrument could be applicable to evaluating the hydration state of the stratum corneum.
1차 년도 G-7 개발 과제로 수행된 자기 공명 진단 장치 (Magnetic Resonance Imaging System)의 개발 내용을 간략히 소개하였다. 성공적인 IT Compact 자기 공명 진단 장치의 완성을 위해 일차적으로 (1)RF (고주파), Gradient(경사 자계), Spectrometer 등의 Hard-ware 관련 MRI 핵심부분, (2) RF, Gradient, Spectrometer, Magnet 등의 각 Sub-system을 연결, 조합, 조정하여 하나의 체계적인 시스템으로 통합하고 운영하는 과정(System Integration), (3)사용자와 시스템을 연결하는 User Interface, Data Base Management, Real time 운영 SW 등과 (4)임상에 적용하여 구체적인 성능과 효용성을 확인하는 기술 등에 대하여 집중 연구하였다. 개발 방법은 (1)지난 16년간 국내에 축적 된 연구 개발 인력들을 최대한 활용하고 (2)연구 개발을 국제화 시켜 필요한 경우 부분별로 개발 인력을 해외에서 보완하고 (3)소수 정예 전문 인력 주의와 요소 기술 또는 중요 부품을 경쟁성 검토 후 필요 시 Out-sourcing 활용으로 최저의 비용으로 개발 기간을 최소화 하는 데 두었다. 개발된 1.0Tesla자기 공명 영상 장치는 미국 물리 학회에서 규격화한 Phantom및 임상 적용을 통하여 서울대 의대 연구 팀과 지속적으로 성능을 평가해 왔다. 개발된 시스템의 해상도는 $256{\times}256$ head 영상에서 1mm 이 하의 해상도를 가짐을 resolution phantom 을 통하여 확인할 수 있었고, $512{\times}512$ 영상에서 는 약 0.5 mm 의 물체를 분리 해냄으로써 외제 시스템들 보다 우수하게 평가 되었다. 차폐 경사코일의 Eddy current영향은2%이내로 촬영 시 영향은 거의 무시할 수 있었다. 또한, 개발된 영상 기법들, 즉 Multislice/Multi Echo, Oblique angle imaging, 64 Echo train을 갖는 고속 촬영 기술들이 자기 공명 장치에 장착되어 임상 적용에 문제가 없도록 하였다. 또한 20mT/m/Amp의 강력한 능동 차폐 경사 자계 코일(Active Shield Gradient Coil)을 기본 사양으로 하고, 수신단을 최대 6개로 확장토록 하여 2차년도의 초고속 촬영 기법(EPI) 및 Phased Array 코일 촬영이 가능토록 하였다. 1차 년도 개발 과제 수행 결과와 향후 개발 과제를 바탕으로 최종 목표인 국제 경쟁력이 있는 자기 공명 진단 장치 즉 기능과 영상의 질은 선진국 제품과 동일하거나 우수하되, 저가격을 구현한 상용화 제품이 완성되어, 첨단 의료기기로서 산업 구조 고도화에 기여하고 수입대체 뿐만 아니 라 수출을 통한 국익 창출과 국가의 기술을 통한 위상 제고에 기여되길 기대한다.
Purpose : Information about electrical activity inside the brain during fMRl scans is very useful in monitoring physiological function of the patient or locating the spatial position of the activated region in the brain. However, many additional noises appear in the EEG signal acquired during the MRI scan. Gradient induced noise is the biggest one among the noises. In this work, we propose a gradient noise reduction method using the independent component analysis (ICA) method. Materials and Methods : We used a 29-channel MR-compatible EEG measurement system and a 3.0 Tesla MRI system. We measured EEG signals on a subject lying inside the magnet during EPI scans. We selectively removed the gradient noise from the measured EEG signal using the ICA method. We compared the results with the ones obtained with conventional averaging method and PCA method. Results : All the noise reduction methods including the averaging and PCA methods were effective in removing the noise in some extent. However, the proposed ICA method was found to be superior to the other methods. Conclusion : Gradient noise in EEG signals acquired during fMRI scans can be effectively reduced by the ICA method. The noise-reduced EEG signal can be used in fMRI studies of epileptic patients or combinatory studies of fMRI and EEG.
Superparamagnetic iron oxide nanoparticles (SPIONs) are approved by the Food and Drug Administration (FDA) in the United States. SPIONs are used in magnetic resonance imaging (MRI) as contrast agents and targeted delivery in nanomedicine using external magnet sources. SPIONs act as an artificial peroxidase (i.e., nanozyme), and these reactions were highly stable in various pH conditions and temperatures. In this study, we report a nanozyme ability of the clustered SPIONs (CSPIONs) synthesized by the oil-in-water (O/W) method and coated with biocompatible poly(lactic-co-glycolic acid) (PLGA). We hypothesize that the CSPIONs can have high sensitivity toward H2O2 derived from the reaction between a fixed amount of glucose and glucose oxidase (GOX). As a result, CSPIONs oxidized a 2,2'-azino-bis(3-ethylbenzthiazoline-6-sulfonic acid) diammonium salt (ABTS) commonly used as a substrate for hydrogen peroxidase in the presence of H2O2, leading to a change in the color of the substrate. We also utilized a colorimetric assay at 417 nm using various glucose concentrations from 5 mM to 1.25 μM to validate β-D-glucose detection. This study demonstrated that the absorbance value increases along with increasing the glucose level. The results were highly repeated at concentrations below 5 mM (all standard deviations < 0.03). Moreover, the sensitivity and limit of detection were 1.50 and 5.44 μM, respectively, in which CSPIONs are more responsive to glucose than SPIONs. In conclusion, this study suggests that CSPIONs have the potential to be used for glucose detection in diabetic patients using a physiological fluid such as ocular, saliva, and urine.
Caffeic acid phenethyl ester (CAPE) is an active component of propolis obtained from honeybee hives. CAPE possesses anti-mitogenic, anti-carcinogenic, anti-inflammatory, and immunomodulatory activities in diverse systems, which know as displays antioxidant activity and inhibits lipoxygenase activities, protein tyrosine kinase, and nuclear factor kappa B (NF-κB) activation. This study aimed to investigate the effect of CAPE on lipopolysaccharide (LPS)-induced human neutrophil phagocytosis. Human neutrophils were cultured with various concentrations of CAPE (1, 10, and 100 µM) with or without LPS. The pro-inflammatory proteins (tumor necrosis factor-alpha [TNF-α], interleukin [IL]-6 and IL-8) levels were measured after 4 h incubation. To investigate the intracellular signaling pathway, we measured the levels of mitogen-activated protein kinases (MAPK), including phosphorylation of p38, extracellular signal-regulated protein kinases 1 and 2 (ERK1/2) and c-Jun N-terminal kinase (JNK). Next, to evaluate the potential phagocytosis, neutrophils were labeled with iron particles of superparamagnetic iron oxide nanoparticles (SPIONs, 40 nm) for 1 h in culture medium containing 5 mg/mL of iron. The labeling efficiency was determined by Prussian blue staining for intracellular iron and 3T-wighted magnetic resonance imaging. CAPE decreased the activation of intracellular signaling pathways, including ERK1/2 and c-Jun, and expression of pro-inflammatory cytokines, including TNF-α and IL-6, but had no effect on the signaling pathways of p38 and cytokine IL-8. Furthermore, images obtained after mannan-coated SPION treatment suggested that CAPE induced significantly higher signal intensities than the control or LPS group. Together, these results suggest that CAPE regulates LPS-mediated activation of human neutrophils to reduce phagocytosis.
Jeon Yong Sun;Cho Soon Gu;Choi Sun Keun;Kim Won Hong;Kim Mi Young;Suh Chang Hae
Investigative Magnetic Resonance Imaging
/
v.8
no.1
/
pp.24-31
/
2004
Purpose : To know the differences of proton MR spectroscopic features between recurrent rectal cancer and fibrosis in post-operative period, and to evaluate the possibility to discriminate recurrent rectal cancer from post-operative fibrosis by analysis of proton MR spectra. Materials and Methods : We evaluated the proton MR spectra from 25 soft tissue masses in perirectal area that developed in post-operative period after operation for the resection of rectal cancer. Our series included 11 cases of recurrent rectal cancer and 14 of fibrotic mass. All cases of recurrent rectal cancer and post-operative fibrosis were confirmed by biopsy. We evaluated the spectra with an attention to the differences of pattern of the curves between recurrent rectal cancer and post-operative fibrosis. The ratio of peak area of all peaks at 1.6-4.1ppm to lipid (0.9-1.6ppm) [P (1.6-4.1ppm/P (0.9-1.6ppm)] was calculated in recurrent rectal cancer and post-operative fibrosis groups, and compared the results between these groups. We also evaluated the sensitivity and specificity for discriminating recurrent rectal cancer from post-operative fibrosis by analysis of $^1H-MRS$. Results : Proton MR spectra of post-operative fibrosis showed significantly diminished amount of lipids compared with that of recurrent rectal cancer. The ratio of P (1.6-4.1ppm)/P (0.9-1.6ppm) in post-operative fibrosis was much higher than that of recurrent rectal cancer with statistical significance (p < .05) due to decreased peak area of lipids. Mean (standard deviations of P (1.6-4.1ppm)/P (0.9-1.6ppm) in post-operative fibrosis and recurrent rectal cancer group were $2.71{\pm}1.48\;and\;0.29{\pm}0.11$, respectively. With a cut-off value of 0.6 for discriminating recurrent rectal cancer from post-operative fibrosis, both the sensitivity and specificity were $100\%$ (11/11, and 14/14). Conclusion : Recurrent rectal cancer and post-operative fibrosis can be distinguished from each other by analysis of proton MR spectroscopic features, and $^1H-MRS$ can be a new method for differential diagnosis between recurrent rectal cancer and post-operative fibrosis.
Kang Young Hye;Lee Yoon Mi;Park Sun Won;Suh Chang Hae;Lim Myung Kwan
Investigative Magnetic Resonance Imaging
/
v.8
no.2
/
pp.79-85
/
2004
Purpose : To evaluate the usefulness and reproducibility of $^1H$ MRS in different 1.5 T MR machines with different coils to compare the SNR, scan time and the spectral patterns in different brain regions in normal volunteers. Materials and Methods : Localized $^1H$ MR spectroscopy ($^1H$ MRS) was performed in a total of 10 normal volunteers (age; 20-45 years) with spectral parameters adjusted by the autoprescan routine (PROBE package). In all volunteers, MRS was performed in a three times using conventional MRS (Signa Horizon) with 1 channel coil and upgraded MRS (Echospeed plus with EXCITE) with both 1 channel and 8 channel coil. Using these three different machines and coils, SNRs of the spectra in both phantom and volunteers and (pre)scan time of MRS were compared. Two regions of the human brain (basal ganglia and deep white matter) were examined and relative metabolite ratios (NAA/Cr, Cho/Cr, and mI/Cr ratios) were measured in all volunteers. For all spectra, a STEAM localization sequence with three-pulse CHESS $H_2O$ suppression was used, with the following acquisition parameters: TR=3.0/2.0 sec, TE=30 msec, TM=13.7 msec, SW=2500 Hz, SI=2048 pts, AVG : 64/128, and NEX=2/8 (Signa/Echospeed). Results : The SNR was about over $30\%$ higher in Echospeed machine and time for prescan and scan was almost same in different machines and coils. Reliable spectra were obtained on both MRS systems and there were no significant differences in spectral patterns and relative metabolite ratios in two brain regions (p>0.05). Conclusion : Both conventional and new MRI systems are highly reliable and reproducible for $^1H$ MR spectroscopic examinations in human brains and there are no significant differences in applications for $^1H$ MRS between two different MRI systems.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.