The Usefulness of $^{99m}Tc$-Sestamibi Scan in Preoperative Localization in Primary Hyperparathyroidism

원발성 부갑상선 기능 항진증의 수술전 병소확인에서 $^{99m}Tc$-Sestamibi 스캔의 유용성

  • Baik, S.H. (Department of Internal Medicine, Korea University College of Medicine) ;
  • Kim, S.M. (Department of Internal Medicine, Korea University College of Medicine) ;
  • Choi, K.M. (Department of Internal Medicine, Korea University College of Medicine) ;
  • Choi, Y.S. (Department of Internal Medicine, Korea University College of Medicine) ;
  • Kim, S.J. (Department of Internal Medicine, Korea University College of Medicine) ;
  • Yu, J.M. (Department of Internal Medicine, Korea University College of Medicine) ;
  • Choi, D.S. (Department of Internal Medicine, Korea University College of Medicine) ;
  • Choe, J.C. (Department of Radiology, Korea University College of Medicine)
  • 백세현 (고려대학교 의과대학 내과학교실) ;
  • 김수미 (고려대학교 의과대학 내과학교실) ;
  • 최경묵 (고려대학교 의과대학 내과학교실) ;
  • 최윤상 (고려대학교 의과대학 내과학교실) ;
  • 김상진 (고려대학교 의과대학 내과학교실) ;
  • 유재명 (고려대학교 의과대학 내과학교실) ;
  • 최동섭 (고려대학교 의과대학 내과학교실) ;
  • 최재걸 (고려대학교 의과대학 방사선과학교실)
  • Published : 1995.12.25

Abstract

An accurate preoperative localization in patients with primary hyperparathyroidism is important for successful surgical intervention. There are many methods for the localization of the primary hyperparathyroidism such as ultrasonography, computerized tomography(CT), magnetic resonance imaging(MRI), angiography and $^{201}T1/^{99m}Tc$ subtraction scan. Among them $^{201}T1/^{99m}Tc$ subtraction scan is known as the most accurate tool for preoperative localization. Recently $^{99m}Tc$-Sestamibi has been used for parathyroid gland imaging. We experienced 19 primary hyperparathyroidisms accurately localized with $^{201}T1/^{99m}Tc$ subtraction imaging and $^{99m}Tc$-Sestamibi. The sensitivities of the $^{99m}Tc$-Sestanibi, $^{201}T1/^{99m}Tc$ subtraction imaging, CT and US were 100%(5/5), 89.5%(17/19) and 61.7(12/19) respectively. With the combination of $^{99m}Tc$-Sestamibi and $^{201}T1/^{99m}Tc$ subtraction imaging we could localize with 100% accuracy. Although the case number is small, this study suggests that the $^{99m}Tc$-Sestamibi parathyroid scan is very useful and easy to use for preoperative localization in primary hyperparathyroidism.

목적 : 원발성 부갑상선기능 항진증의 대부분의 원인인 부갑상선 선종의 유일한 완치는 수술이며 수술의 성패에 가장 중요한 것은 수술전의 정확한 ??소의 확인이다. 다양한 영상검사들이 동원되고있으나 각가 결점이 있고 가장 특이도가 높은 $^{201}T1-^{99m}Tc$감영 촬영방법도 검사방법등에 문제점이 있다. 이에 원발성 부갑상선기능 항진증 환자에게 최근에 사용되고있는 $^{99m}Tc$-Sestamibi 부갑상선 스캔의 유용성을 알아보고자 하였다. 대상 및 방법 : 19명의 부갑상선기능 항진증환자에서 모든 환자에게 초음파 검사, CT, $^{201}T1-^{99m}Tc$감영 촬영을 시행하고 그중 5명은 $^{99m}Tc$-Sestamibi 부갑상선 스캔을 시행하여 수술후 확진결과와 함께 비교하였다. 결과 : 초음파 검사와 CT 및 $^{201}T1-^{99m}Tc$감영 스캔은 19예중 각가 12예(67.1%), 14예(78.9%) 그리고 17예(89.5%)에서 병소확인이 가능하였고 $^{99m}Tc$-Sestamibi 부갑상선 스캔은 시행한 5예(100%) 모두에서 병소 확인이 가능하였다. 결론 : 이상의 결과로 $^{99m}Tc$-Sestamibi 부갑상선 스캔은 원발성 부갑상선기능 항진증의 수술전 병소확인에서 유용한 검사법으로 이용될 수 있으리라 사료된다.

Keywords